VALIDASI METODE ANALISIS AKTIVASI NEUTRON INSTRUMENTAL UNTUK UNSUR-UNSUR ESENSIAL DALAM CUPLIKAN HAYATI MENGGUNAKAN SRM NIST 1573a RAMZY DEPARTEMEN KIMIA FAKULTAS MATEMATIKA DAN ILMU PENGETAHUAN ALAM INSTITUT PERTANIAN BOGOR BOGOR 2008
ABSTRAK RAMZY. Validasi Metode Analisis Aktivasi Neutron Instrumental untuk Unsur-Unsur Esensial Dalam Cuplikan Hayati Menggunakan SRM NIST 1573a. Dibimbing oleh ETI ROHAETI dan SAEFUL WSUF. Mineral merupakan faktor esensial dalam tubuh yang memiliki peranan berbeda-beda dalam sistem metabolisme, antara lain sebagai kofaktor enzim dalam berbagai reaksi biokimia dan sintesis hormon. Kelebihan ataupun kekurangan unsur-unsur mineral dalam tubuh dapat menyebabkan berbagai penyakit. Oleh karena itu, penentuan unsur-unsur mineral menjadi penting untuk dilakukan. Analisis aktivasi neutron instrumental (AANI) adalah teknik analisis dengan limit deteksi rendah dan termasuk analisis multi unsur. Validasi diperlukan untuk mengkaji presisi dan akurasi hasil pengujian metode AANI ini. Validasi dalam penelitian ini dilakukan menggunakan SRM NIST (Standard Reference Materials National Institute of Standard Technology) 1573a (tomato leaves). Unsur-unsur yang tervalidasi ialah Se, Cr, dan Co. Metode AANI menghasilkan data untuk ketiga unsur ini dengan mutu data yang baik; penyimpangan relatif berkisar 20%, hasil uji U lebih kecil dari 1,95, nilai uji Z dari data yang dihasilkan dapat diterima pada tingkat kepercayaan 95%, dan memenuhi syarat uji presisi dan akurasi. Validasi ditentukan menggunakan persamaan statistika dari International Atomic Energy Agency. Untuk ketiga unsur tersebut, telah ditentukan limit deteksi sebagai berikut: Se 0,165 ppm, Cr 0,426 ppm, dan Co 0,076 ppm. Metode ini dapat diaplikasikan untuk penentuan unsur Se, Cr, dan Co dalam cuplikan hayati lain seperti darah. ABSTRACT RAMZY. Validation of INAA Method for Essential Elements on Biological Samples Using SRMNlST 1573a. Supervised by ETI ROHAETI and SAEFUL WSUF. Minerals are essential factor on body that show various roles in metabolism system, such as enzyme cofactor in biochemical reaction and hormone synthesis. An excess or deficiency of minerals cause diseases. Therefore, determination of minerals become important to be done. Instrumental Neutron Activation Analysis (INAA) is an analysis technique with low limit of detection and a multi-element analysis. Validation is needed to observe the accuration and precision of the result of this INAA method. This validation used Standard Reference Material National Institute of Standard Technology (SRM NIST) 1573a (tomato leaves). Validated elements were Se, Cr, and Co. INAA method produced good quality data for these; relative-bias less than about 20%, U-test score less than 1,95,Z-score data acceptable for confidence interval of 95%, and also acceptable on precision and accuracy test. Validation was determined by using statistical equation according to International Atomic Energy Agency. For these three elements the limit of detection were 0,165 ppm for Se, 0,426 ppm for Cr, and 0,076 ppm for Co. This method is possible to be used to determine Se, Cr, and Co on biological sample such as blood.
VALIDASI METODE ANALISIS AKTIVASI NEUTRON INSTRUMENTAL UNTUK UNSUR-UNSUR ESENSIAL DALAM CUPLIKAN HAYATI MENGGUNAKAN SRM NIST 1573a RAMZY Skripsi sebagai salah satu syarat memperoleh gelar Sarjana Sains pada Departemen Kimia DEPARTEMEN KIMIA FAKULTAS MATEMATIKA DAN ILMU PENGETAHUAN ALAM INSTITUT PERTANIAN BOGOR BOGOR 2008
Judul : Validasi Metode Analisis Aktivasi Neutron Instrumental Untuk Unsur- Unsur Esensial Dalam Cuplikan Hayati Menggunakan SRM NIST 1573a Nama : Ramzy HIM : G44204020 Menyetujui, Pembimbing I, Pembimbing 11, Dr. Eti Rohaeti, MS NIP 131 663 015 Drs. Saeful Yusuf, MT NIP 330 003 600 Dek getahuan Alam