ENERGY IS OUR BUSINESS. Aspek Design Thermal Pada Power Transformer. Himawan Samodra Pauwels Trafo Asia

Ukuran: px
Mulai penontonan dengan halaman:

Download "ENERGY IS OUR BUSINESS. Aspek Design Thermal Pada Power Transformer. Himawan Samodra Pauwels Trafo Asia"

Transkripsi

1 ENERGY IS OUR BUSINESS Aspek Design Thermal Pada Power Transformer Himawan Samodra Pauwels Trafo Asia 1

2 Terminology Top Oil Rise: Top oil temperature Ambient temperature Average Winding Rise: Mean winding temperature Ambient temperature Hot Spot Rise: Temperature titik terpanas Ambient temperature Winding Gradient: Mean winding temperature - Mean oil temperature Hot Spot Factor: Hot spot gradient / Average winding gradient IEC merekomendasikan hot spot temperature mutlak = 98 deg C 2

3 Gambar Identifikasi Temperature Rise core winding cooler Gradient H f x gradient Bottom oil Mean oil Top oil Hot spot factor umumnya berkisar 1.1 sampai 1.5 tergantung kostruksi winding. Mean winding Hot spot 3

4 Code Code dengan empat huruf digunakan untuk mendeskripsikan mode cooling system seperti yang dijelaskan pada standard IEC : Huruf pertama menjelaskan: O Menyatakan oil, atau medium lain dengan titik bakar kurang dari 300 C. K Menyatakan cooling liquid dengan titik bakar lebih dari 300 deg C (FR3, Ester based oil, silicon oil). L Menyatakan cooling liquid dengan titik bakar yang tak dapat diukur (dry type transformer). Huruf kedua menjelaskan bagaimana internal cooling medium bersirkulasi: N Natural convection di dalam winding dan pada external cooling system F Internal cooling medium disirkulasi secara paksa menggunakan pump. D Internal cooling medium diarahkan melalui cooling chamber di bawah winding. Pada system ini cooling medium disirkulasi secapa paksa dengan menggunakan pump. Huruf ketiga menyatakan type dari external cooling medium: A Air (udara) WWater (air) Huruf keempat mejelaskan bagaimana external cooling medium bersirkulasi: N Dengan natural convection F Dengan forced convection 4

5 Cooling Method 1 Oil circulation External cooling IEC ANSI C57 BS 171 Natural flow Air Natural flow ONAN OA ON Natural flow Air Forced flow ONAF FA OB Forced (pump) Air Natural flow OFAN - - Forced (pump) Air Forced flow OFAF FOA OFB Forced & Directed Air Forced flow ODAF FOA OFB Forced & Directed Water Forced flow ODWF FOW OFW 5

6 Cooling Method - 2 ONAN Adalah sistem pendinginan yang paling sederhana. Pendinginan ini hanya menggunakan radiator, tanpa memerlukan fans atau pump serta rangkaian sistem controlnya. Ini merupakan sistem pendinginan yang paling handal diantara yang lain, namum memerlukan permukaan cooling yang paling luas. Keuntungan lain dari type cooling ini adalah noise level yang ditimbulkan sangat rendah. Kerugiannya adalah rendahnya efisiensi cooling sehinggan hanya efektif untuk pendingin trafo-trafo kecil. ONAF Adalah sistem pendingin ONAN yang dilengkapi dengan fans untuk mendorong udara ke dalam radiator. Fans digunakan untuk mendorong udara dari bawah ke atas (counterflow) atau ke arah samping (cross-flow). Penambahan cooling fans pada radiator akan sangat meningkatkan efisiensi system pendingin. Kebanyakan dari sistem cooling dikombinasi dengan ONAN cooling untuk mengurangi auxiliary losses pada rating MVA rendah. Kerugian dari sistem pendingian ini adalah noise level yang tinggi yang ditimbulkan oleh cooling fans. 6

7 Cooling Method - 3 ODAN Serupa dengan sistem pendinginan ONAN, kecuali adanya pump yang digunakan untuk mensirkulasi oil ke dalam winding. Dibandingkan dengan ONAN design, the top-to-bottom oil temperature rise lebih rendah karena volume oil yang masuk ke dalam winding lebih banyak. Ini akan menurunkan top oil rise dan hot spot temperature rise, sehingga memungkinkan design cooler yang lebih compact. Winding gradient yang lebih rendah pada tingkat losses yang sama merupakan keuntungan tambahan dari type pendinginan ini. Sistem pendinginan ini sangat jarang digunakan. Option ini akan dipilih bila transformer dengan cooling ONAN dirasa terlalu besar dan mahal, sedangkan ONAF dirasa terlalu menimbulkan noise (bising). ODAF Fans digunakan untuk mensirkulasi udara dan pump untuk mensirkulasi oil ke dalam winding. Baik radiator bank ataupun heat exchangers dapat digunakan pada sistem ini. Dengan menggunakan radiator, sistem cooling ini dapat dikombinasi dengan ONAN dan ONAF sedangkan dengan heat exchanger tidak. Sistem cooling ini menpunyai efisiensi yang sangat tinggi dan sangat efektif untuk sistem pendinginan trafo-trafo besar di atas 100 MVA. Kerugian dari sistem cooling ini adalah noise level yang tinggi dan sistem control yang lebih kompleks. Tingkat kompleksitas design dari sistem ODAF juga lebih tinggi. 7

8 Cooling Method - 4 ODWF Pada sistem ini, oil/water heat exchangers digunakan untuk mendinginkan trafo. Type cooling ini sangat efisien dan compact. Kelemahan dari sistem ini adalah diperlukannya supplai air untuk external cooling medium. Banyak digunakan pada Generator Trafo pada Hydro Power Plant dimana supplai air tidak menjadi kendala. Berikut adalah contoh Heat Exchanger type Plate. 8

9 Standard Temperature Rise Limit Menurut standard IEC , standard temperature rise limit adalah sebagai berikut: Top oil temperature rise 60K Winding temperature rise 65K untuk ON cooling dan 70K untuk OD cooling Winding hot spot temperature rise 78K Core interior hot spot temperature rise 115K Tank surface temperature rise 80K Standard temperature rise di atas berlaku jika rata-rata tahunan ambient temperature adalah 20 deg C dan rata-rata ambient temperatur pada bulan terpanas adalah 30 degc. Range ambient temperature normal adalah antara -25 deg C sampai 40 deg C. Jika range ambient temperature melampai range di atas, maka diperlukan design khusus. Mengingat rata-rata tahunan ambient temperatur di Indonesia adalah 30 deg C, maka batas temperature rise di atas disarankan untuk diturunkan 10 deg C untuk mendapatkan tingkat temperatur mutlak yang sama. Top oil rise limit = 50K Average winding rise limit = 55K Hot spot rise limit = 68K 9

10 Ambient Temperature Average Yearly Temperature : misalnya 30 deg C Rata-rata ambient temperature dalam satu tahun Digunakan sebagai acuan untuk perhitungan life time dari transformer Sebagai acuan untuk menentukan nilai temperature rise IEC recommendation Average Temp + Hot Spot Rise < 98 deg C Design dengan upgraded insulation paper untuk hot spot temperature lebih tinggi dari 98 deg C. Average Temperature at the Hottest Month : misalnya 35 deg C Rata-rata temperature di bulan terpanas. Digunakan sebagai acuan untuk menghitung hot spot temperature pada saat overload emergency loading. Hottest Temperature at any one day : misalnya 40 deg C Temperature terpanas dalam satu tahun Digunakan sebagai acuan untuk mengitung winding temperature pada saat terjadi short circuit. 10

11 Factor Yang Mempengaruhi Thermal Design Ambient Temperature Ketinggian Pemasangan Trafo Semakin tinggi suatu lokasi, semakin rendah kerapatan udara, sehingga efisiensi sistem pendingin menurun. Standard ketinggian untuk thermal design adalah kurang dari 1000m. Termperature rise limit harus diturunkan 1K untuk setiap kenaikan 400m di atas 1000m untuk ONAN cooling dan 250m untuk ONAF cooling. Solar Radiation Transformers installed in direct sunlight are subject to additional heating owing to solar radiation (solar gain). This additional heating can be taken into account by considering it to be an additional loss, which must be dissipated to the surroundings. Solar radiation is most intense in tropical regions (where the sun is highest in the sky and least radiation is absorbed by the atmosphere), at high altitudes (where there is less atmosphere between the transformer and the sun) and in desert regions (where there is little natural shade). Jika tidak ada data tentang solar radiation, nilai tersebut dapat kita asumsikan 1200 W/m2 untuk daerah tropis. Tingkat Kebisingan dari Transformator 11

12 Oil Flow Type Axial oil flow: Penggunaan cooling axial kanal (clack band) dalam winding. Gradient winding umumnya lebih tinggi dibanding zigzag oil flow. Filling factor winding menjadi jelek karena space yang dipakai untuk axial kanal. Zigzag oil flow: Penggunaan oil flow washer untuk mengarahkan oil dalam winding. Pendingin dalam winding lebih effective karena oil dipaksa masuk ke celahcelah winding. Natural oil flow: Sirkulasi oil secara alami di dalam winding karena pebedaan temperature (thermosiphon effect). Forced oil flow: Penggunaan oil pump untuk sirkulasi oil paksa. Gradient Winding ditentukan oleh kecepatan oil di dalam winding. Metode cooling ini sangat efficient untuk trafo-trafo berukuran besar (di atas 100MVA) dimana cooling sudah menjadi kendala dalam design. 12

13 Arrangement Oil Flow di Dalam Winding Gambar axial oil flow Gambar zigzag oil flow 13

14 Pemasangan Oil flow Washer Tipe sumbatan luar Tipe sumbatan dalam Gambar zigzag oil flow 14

15 Cooling Exponent Gradient Exponent Adalah nilai exponent untuk mengekstrapolasi nilai gadient sebagai fungsi dari current density. ON dengan axial oil flow = 1.60 ON dengan zig zag oil flow = 1.20 OD = 2.0 Oil Temperature Exponent Adalah nilai exponent untuk mengekstrapolasi nilai oil temperature sebagai fungsi dari total losses. ON = 0.80 FA = 0.90 OD =

16 Hot Spot Factor Nilai hot spot factor berkisar antara 1.1 sampai 1.5 tergantung pada konstruksi winding. Pada medium power transformer (20-150MVA), nilai hot spot factor yang dipakai adalah 1.3 (menurut standard IEC). Terjadi pada daerah Top Winding karena intensitas eddy current losses yang lebih tinggi akibat dari efek radial flux bending, masuk ke arah sisi lebar konduktor. Tergantung pada ukuran wire di daerah top winding. Semakin lebar ukuran wire, semakin besar hot spot factor. Penggunaan axial twin conductor atau CTC dapat menurunkan hot spot factor pada trafo-trafo besar. Tergantung pada impedansi dan rating trafo. Semakin besar impedansi semakin besar hot spot factor, karena efek stray flux semakin besar sehingga intensitas eddy current losses di daerah top winding meningkat tajam. 16

17 Efek Bending Stray Flux pada bagian atas Winding 17

18 Laju Penuaan Isolasi (Insulation Aging Rate) Hot Spot Temperature ( o C) Aging Rate

19 Thermal Aging Contoh Kasus 19

20 Winding Temperature Indicator 20

21 Korelasi antara Arus dan Winding Gradient 21

22 Cooling Medium Internal Cooling Medium Mineral oil untuk class A insulation. Maximum oil temperature adalah 115 deg C. Applicable untuk kraft paper insulation ataupun thermally upgraded paper insulation class A. Silicon oil untuk class K insulation. Titik bakar silicon oil mencapai 300 deg C. Biasanya digunakan pada hybrid design transformer atau high temperature rise transformer dengan NOMEX insulation pada slim design transformer. Ester based oil (FR3 - Envirotemp) untuk ramah lingkungan. Voscositas tinggi pada suhu rendah, sehingga sirkulasi kurang baik. Pada suhu tinggi, sirkulasi oil lebih baik. External Cooling Medium Udara (radiator atau air cooler). Air (water cooler). Water cooling system adalah sistem pendinginan yang sangat effektif, tidak memerlukan banyak ruang. 22

23 Degree of Polimerization DP > <200 Estimasi Sisa Umur Trafo (%) 100% 90% 60-66% 30% 0% 23

24 Panduan Emergency Over Load Long Time Emergency Rating: 120% dari nominal rating Maximum top oil temperature tidak melebihi 100 deg C Maximum hot spot temperature tidak melebihi 115 deg C Durasi pembebanan antara 2 sampai 4 jam, tergantung pada time constant transformer Berdampak pada pengurangan life time dari trafo Short Time Emergency Rating: 150% dari nominal rating Maximum top oil temperature tidak melebihi 115 deg C Maximum hot spot temperature tidak melebihi 130 deg C Durasi pembebanan antara 0.5 sampai 1.0 jam, tergantung pada time constant dari transformer. Berdampak pada pengurangan life time dari trafo 24

25 Long Time Emergency Overload 120% 60 MVA 150/20kV PLN Standard Transformer Ambient 30 deg C Loading Time Top Oil Temp Hot Spot Temp Winding Gradient (minute) (deg C) (deg C) (deg C)

26 Short Time Emergency Overload 150% 60 MVA 150/20kV PLN Standard Transformer Ambient 30 deg C Loading Time Top Oil Temp Hot Spot Temp Winding Gradient (minute) (deg C) (deg C) (deg C)

27 Pemasangan Fibre Optic 27

28 Pemasangan Fibre Optic 28

29 Fibre Optic Monitoring 29

30 END 30

Core and Winding Design

Core and Winding Design ENERGY IS OUR BUSINESS Core and Winding Design Himawan Samodra Pauwels Trafo Asia 1 Core Cutting Type BLOO But lap cutting type BLOO: Higher no load losses and higher noise generated Without V notch cutting

Lebih terperinci

ENERGY IS OUR BUSINESS. Transformer Test. Himawan Samodra Pauwels Trafo Asia Temperature Rise TRANSFORMING YOUR NEEDS INTO SOLUTIONS

ENERGY IS OUR BUSINESS. Transformer Test. Himawan Samodra Pauwels Trafo Asia Temperature Rise TRANSFORMING YOUR NEEDS INTO SOLUTIONS ENERGY IS OUR BUSINESS Transformer Test Himawan Samodra Pauwels Trafo Asia 1 General Tujuan Transformer Test : Untuk memverifikasi seberapa jauh transformer memenuhi requirement tertentu (loading capability,

Lebih terperinci

Sofyan 1, Afriyastuti Herawati 1*

Sofyan 1, Afriyastuti Herawati 1* engaruh embebanan Terhadap Efisiensi dan Usia Transformator (Studi Kasus Transformator IV Gardu Induk Sukamerindu Bengkulu) Berdasarkan Standar IEC 60076-7 Sofyan 1, Afriyastuti Herawati 1* 1 rogram Studi

Lebih terperinci

STUDI SUSUT UMUR TRANSFORMATOR DISTRIBUSI 20 kv AKIBAT PEMBEBANAN LEBIH DI PT.PLN (PERSERO) KOTA PONTIANAK

STUDI SUSUT UMUR TRANSFORMATOR DISTRIBUSI 20 kv AKIBAT PEMBEBANAN LEBIH DI PT.PLN (PERSERO) KOTA PONTIANAK STUDI SUSUT UMUR TRANSFORMATOR DISTRIBUSI 20 kv AKIBAT PEMBEBANAN LEBIH DI PT.PLN (PERSERO) KOTA PONTIANAK Parlindungan Gultom 1), Ir. Danial, MT. 2), Managam Rajagukguk, ST, MT. 3) 1,2,3) Program Studi

Lebih terperinci

UNIVERSITAS INDONESIA ANALISIS PENGARUH TEMPERATUR TERHADAP MASA GUNA DAN PEMBEBANAN DARURAT TRANSFORMATOR DAYA TESIS

UNIVERSITAS INDONESIA ANALISIS PENGARUH TEMPERATUR TERHADAP MASA GUNA DAN PEMBEBANAN DARURAT TRANSFORMATOR DAYA TESIS UNIVERSITAS INDONESIA ANALISIS PENGARUH TEMPERATUR TERHADAP MASA GUNA DAN PEMBEBANAN DARURAT TRANSFORMATOR DAYA TESIS DEWANTO INDRA KRISNADI 09 06 57 77 66 FAKULTAS TEKNIK PROGRAM MAGISTER TEKNIK ELEKTRO

Lebih terperinci

BAB II PRINSIP DASAR TRANSFORMATOR

BAB II PRINSIP DASAR TRANSFORMATOR BAB II PRINSIP DASAR TRANSFORMATOR 2.1 UMUM Transformator (trafo ) merupakan piranti yang mengubah energi listrik dari suatu level tegangan AC lain melalui gandengan magnet berdasarkan prinsip induksi

Lebih terperinci

ABSTRAK. Universitas Kristen Maranatha

ABSTRAK. Universitas Kristen Maranatha ABSTRAK Sebuah transformator dapat dibebani secara terus menerus sesuai dengan kemampuan nominalnya. Pada prakteknya sangat jarang terjadi pembebanan sebuah transformator secara terus menerus pada nominalnya.

Lebih terperinci

STUDI PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR DAYA (APLIKASI PADA GARDU INDUK PEMATANGSIANTAR)

STUDI PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR DAYA (APLIKASI PADA GARDU INDUK PEMATANGSIANTAR) STUDI PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR DAYA (APLIKASI PADA GARDU INDUK PEMATANGSIANTAR) Junedy Pandapotan Eddy Warman Konsentrasi Teknik Energi Listrik Departemen Teknik Elektro Fakultas

Lebih terperinci

JENIS-JENIS TRANSFORMATOR

JENIS-JENIS TRANSFORMATOR JENIS-JENIS TRANSFORMATOR OUTLINE Jenis-jenis transformator dapat dibagi menjadi beberapa macam, tergantung dari: A. Letak kumparan terhadap inti B. Perbandingan transformator C. Konstruksi inti transformator

Lebih terperinci

BAB II TINJAUAN PUSTAKA

BAB II TINJAUAN PUSTAKA BAB II TINJAUAN PUSTAKA 2.1 Umum Transformator adalah suatu alat listrik yang dapat memindahkan dan mengubah energi dari satu atau lebih rangkaian listrik ke rangkaian listrik yang lain, melalui suatu

Lebih terperinci

MINGGU IX Transformer tank and cooling system Transformer Tank Requirements Tank Construction Transformer Cooling 6 Tangki Trafo dan sistim pendingin

MINGGU IX Transformer tank and cooling system Transformer Tank Requirements Tank Construction Transformer Cooling 6 Tangki Trafo dan sistim pendingin MINGGU IX Transformer tank and cooling system Transformer Tank Requirements Tank Construction Transformer Cooling 6 Tangki Trafo dan sistim pendingin 6.1 Kebutuhan Tangki Trafo Tangki dibuat dengan membentuk

Lebih terperinci

BAB III FORMULASI PENENTUAN SUSUT UMUR TRANSFORMATOR DISTRIBUSI

BAB III FORMULASI PENENTUAN SUSUT UMUR TRANSFORMATOR DISTRIBUSI BAB III FORMULASI PENENTUAN SUSUT UMUR TRANSFORMATOR DISTRIBUSI 3.1 Pendahuluan Pada bab ini akan diformulasikan hubungan antara kenaikan suhu yang melebihi batas - batas kemampuan isolasi dengan susutnya

Lebih terperinci

Studi Analisa Pengaruh Pembebanan Dan Temperatur Lingkungan Terhadap Susut Umur Tranformator Daya Pada Gardu Induk Garuda Sakti

Studi Analisa Pengaruh Pembebanan Dan Temperatur Lingkungan Terhadap Susut Umur Tranformator Daya Pada Gardu Induk Garuda Sakti Studi Analisa Pengaruh Pembebanan Dan Temperatur Lingkungan Terhadap Susut Umur Tranformator Daya Pada Gardu Induk Garuda Sakti Kurniawan*, Firdaus** Jurusan Teknik Elektro Fakultas Teknik Universitas

Lebih terperinci

LAPORAN TUGAS AKHIR PEMBUATAN SISTEM SIRKULASI AIR PENDINGIN KONDENSOR PERALATAN PIROLISIS SAMPAH PLASTIK

LAPORAN TUGAS AKHIR PEMBUATAN SISTEM SIRKULASI AIR PENDINGIN KONDENSOR PERALATAN PIROLISIS SAMPAH PLASTIK LAPORAN TUGAS AKHIR PEMBUATAN SISTEM SIRKULASI AIR PENDINGIN KONDENSOR PERALATAN PIROLISIS SAMPAH PLASTIK Disusun oleh: SEFI YUDA YURI YUAN DANA I 8310055 SENO PRASETYO I 8310058 TANGGUH PERWIRA NEGARA

Lebih terperinci

Pratama Akbar Jurusan Teknik Sistem Perkapalan FTK ITS

Pratama Akbar Jurusan Teknik Sistem Perkapalan FTK ITS Pratama Akbar 4206 100 001 Jurusan Teknik Sistem Perkapalan FTK ITS PT. Indonesia Power sebagai salah satu pembangkit listrik di Indonesia Rencana untuk membangun PLTD Tenaga Power Plant: MAN 3 x 18.900

Lebih terperinci

PENGARUH PEMBEBANAN TERHADAP KENAIKAN SUHU PADA BELITAN TRANSFORMATOR DAYA JENISTERENDAM MINYAK

PENGARUH PEMBEBANAN TERHADAP KENAIKAN SUHU PADA BELITAN TRANSFORMATOR DAYA JENISTERENDAM MINYAK PENGARUH PEMBEBANAN TERHADAP KENAIKAN SUHU PADA BELITAN TRANSFORMATOR DAYA JENISTERENDAM MINYAK Janny Olny Wuwung Abstrak: Penelitian ini bertujuan (1) Menghitung kenaikan ; (2) Menghitung kenaikan titik-panas;

Lebih terperinci

ABSTRAK. Kata Kunci : Transformator, Susut Umur

ABSTRAK. Kata Kunci : Transformator, Susut Umur ABSTRAK Susut umur pada transformator dipengaruhi oleh isolasi belitan transformator dan minyak transformator. Salah satu kerusakan atau kegagalan isolasi dari minyak transformator diakibatkan dari perubahan

Lebih terperinci

DAFTAR ISI HALAMAN JUDUL... KATA PENGANTAR... HALAMAN PENGESAHAN PEMBIMBING... HALAMAN PENGESAHAN PENGUJI... DAFTAR ISI... DAFTAR GAMBAR...

DAFTAR ISI HALAMAN JUDUL... KATA PENGANTAR... HALAMAN PENGESAHAN PEMBIMBING... HALAMAN PENGESAHAN PENGUJI... DAFTAR ISI... DAFTAR GAMBAR... DAFTAR ISI HALAMAN JUDUL... KATA PENGANTAR... HALAMAN PENGESAHAN PEMBIMBING... HALAMAN PENGESAHAN PENGUJI... DAFTAR ISI... DAFTAR GAMBAR... DAFTAR TABEL... ABSTRAK... i ii iii iv v vii ix x I. PENDAHULUAN...

Lebih terperinci

DAFTAR ISI. HALAMAN JUDUL... ii HALAMAN PENGESAHAN DOSEN PEMBIMBING...iii HALAMAN PENGESAHAN DOSEN PENGUJI...iv

DAFTAR ISI. HALAMAN JUDUL... ii HALAMAN PENGESAHAN DOSEN PEMBIMBING...iii HALAMAN PENGESAHAN DOSEN PENGUJI...iv DAFTAR ISI Halaman HALAMAN JUDUL...... ii HALAMAN PENGESAHAN DOSEN PEMBIMBING...iii HALAMAN PENGESAHAN DOSEN PENGUJI...iv MOTTO...v KATA PENGANTAR...vi PERSEMBAHAN...vii DAFTAR ISI...viii DAFTAR GAMBAR...

Lebih terperinci

ABSTRAK Kata Kunci :

ABSTRAK Kata Kunci : ABSTRAK Transformator 3 pada GI Pesanggaran mendapat penambahan 4 blok pembangkit dengan daya maksimum sebesar 60 MW daya dari keempat blok pembangkit tersebut digunakan untuk mensuplai beban penyulang

Lebih terperinci

Analisis Unjuk Kerja Tiga Unit Inter Bus Transformers 500 MVA 500/150/66 kv di GITET Kediri

Analisis Unjuk Kerja Tiga Unit Inter Bus Transformers 500 MVA 500/150/66 kv di GITET Kediri ELPOSYS Jurnal Sistem Kelistrikan Vol. 03 No.1, ISSN: 2355 9195, E-ISSN: 2356-0533 Analisis Unjuk Kerja Tiga Unit Inter Bus Transformers 500 MVA 500/150/66 kv di GITET Kediri Aan M. Ilham *a), Rachmat

Lebih terperinci

ANALISIS PENGARUH KENAIKAN TEMPERATUR TERHADAP TEGANGAN TEMBUS DAN NILAI HARAPAN HIDUP ISOLASIPADAT DAN CAIR TRANSFORMATOR

ANALISIS PENGARUH KENAIKAN TEMPERATUR TERHADAP TEGANGAN TEMBUS DAN NILAI HARAPAN HIDUP ISOLASIPADAT DAN CAIR TRANSFORMATOR ANALISIS PENGARUH KENAIKAN TEMPERATUR TERHADAP TEGANGAN TEMBUS DAN NILAI HARAPAN HIDUP ISOLASIPADAT DAN CAIR TRANSFORMATOR Ahmad Yanuar Hidayat, Iwa Garniwa M.K Teknik Elektro,Fakultas Teknik Universitas

Lebih terperinci

ANALISA BEBAN LEBIH PADA TRANSFORMATOR DAYA 70/20 KV DI GI BUNGARAN DENGAN MENGGUNAKAN PROGRAM ETAP 11 LAPORAN AKHIR

ANALISA BEBAN LEBIH PADA TRANSFORMATOR DAYA 70/20 KV DI GI BUNGARAN DENGAN MENGGUNAKAN PROGRAM ETAP 11 LAPORAN AKHIR ANALISA BEBAN LEBIH PADA TRANSFORMATOR DAYA 70/20 KV DI GI BUNGARAN DENGAN MENGGUNAKAN PROGRAM ETAP 11 LAPORAN AKHIR Disusun Untuk Memenuhi Syarat Menyelesaikan Pendidikan Diploma III Pada Jurusan Teknik

Lebih terperinci

JURNAL TEKNIK POMITS Vol. 3, No. 2, (2014) ISSN: B-169

JURNAL TEKNIK POMITS Vol. 3, No. 2, (2014) ISSN: B-169 JURNAL TEKNIK POMITS Vol. 3, No. 2, (2014) ISSN: 2301-9271 B-169 Studi Numerik Peningkatan Cooling Performance pada Lube Oil Cooler Gas Turbine yang Disusun Secara Seri dan Paralel dengan Variasi Kapasitas

Lebih terperinci

ANALISA COOLING SISTEM GE FRAME 9 PLTG SICANANG 120MW

ANALISA COOLING SISTEM GE FRAME 9 PLTG SICANANG 120MW ANALISA COOLING SISTEM GE FRAME 9 PLTG SICANANG 120MW oleh Yogi Sirodz Gaos 1 dan Candra Damis Widiawati 2 1Engineering and Devices for Energy Conversion Research Lab., Fakultas Teknik Universitas Ibn

Lebih terperinci

Prinsip kerja PLTG dapat dijelaskan melalui gambar dibawah ini : Gambar 1.1. Skema PLTG

Prinsip kerja PLTG dapat dijelaskan melalui gambar dibawah ini : Gambar 1.1. Skema PLTG 1. SIKLUS PLTGU 1.1. Siklus PLTG Prinsip kerja PLTG dapat dijelaskan melalui gambar dibawah ini : Gambar 1.1. Skema PLTG Proses yang terjadi pada PLTG adalah sebagai berikut : Pertama, turbin gas berfungsi

Lebih terperinci

BAB II DASAR TEORI. gesekan antara moekul-molekul cairan satu dengan yang lain. Suatu cairan yang

BAB II DASAR TEORI. gesekan antara moekul-molekul cairan satu dengan yang lain. Suatu cairan yang BAB II DASAR TEORI 2.1. Definisi Viskositas Viskositas dapat dinyatakan sebagai tahanan aliran fluida yang merupakan gesekan antara moekul-molekul cairan satu dengan yang lain. Suatu cairan yang mudah

Lebih terperinci

TRANSFORMATOR DAYA. Dikumpulkan dalam rangka mengerjakan tugas kelompok, mata kuliah Sistem Transmisi dan Gardu Induk.

TRANSFORMATOR DAYA. Dikumpulkan dalam rangka mengerjakan tugas kelompok, mata kuliah Sistem Transmisi dan Gardu Induk. TRANSFORMATOR DAYA Dikumpulkan dalam rangka mengerjakan tugas kelompok, mata kuliah Sistem Transmisi dan Gardu Induk. Disusun Oleh: 1. Arief Nurrahman (02964) 2. R. Maulana S.H (04156 ) 3. Sandi Sulaiman

Lebih terperinci

ANALISA SISTEM PENDINGIN KAPASITAS GPM PADA MESIN DIESEL DI PLTD TITI KUNING

ANALISA SISTEM PENDINGIN KAPASITAS GPM PADA MESIN DIESEL DI PLTD TITI KUNING ANALISA SISTEM PENDINGIN KAPASITAS 1.200 GPM PADA MESIN DIESEL DI PLTD TITI KUNING LAPORAN TUGAS AKHIR Diajukan untuk Memenuhi Sebagian Persyaratan dalam Menyelesaikan Program Pendidikan Diploma III PROGRAM

Lebih terperinci

(Studi Kasus PT. EMP Unit Bisnis Malacca Strait) Dosen Pembimbing Bambang Arip Dwiyantoro, ST. M.Sc. Ph.D. Oleh : Annis Khoiri Wibowo

(Studi Kasus PT. EMP Unit Bisnis Malacca Strait) Dosen Pembimbing Bambang Arip Dwiyantoro, ST. M.Sc. Ph.D. Oleh : Annis Khoiri Wibowo Studi Numerik Peningkatan Cooling Performance pada Lube Oil Cooler Gas Turbine Disusun Secara Seri dan Paralel dengan Variasi Kapasitas Aliran Lube Oil (Studi Kasus PT. EMP Unit Bisnis Malacca Strait)

Lebih terperinci

BAB III TEORI DASAR DAN DATA

BAB III TEORI DASAR DAN DATA BAB III TEORI DASAR DAN DATA 3.1. MENENTUKAN JARAK ARRESTER Analisis data merupakan bagian penting dalam penelitian, karena dengan analisis data yang diperoleh mampu memberikan arti dan makna untuk memecahkan

Lebih terperinci

BAB IV PERHITUNGAN SUSUT UMUR EKONOMIS TRANSFORMATOR DISTRIBUSI

BAB IV PERHITUNGAN SUSUT UMUR EKONOMIS TRANSFORMATOR DISTRIBUSI BAB IV PERHITUNGAN SUSUT UMUR EKONOMIS TRANSFORMATOR DISTRIBUSI 4.1 Ambient Temperature pada Gardu Beton Tanpa Exhaust Fan Dalam studi mengenai analisis pengkondisian ambient temperature pada gardu beton

Lebih terperinci

HEAT INSULATION THERMAL COMFORT DESIGN CONSULTATION. Canisius College Sport Hall

HEAT INSULATION THERMAL COMFORT DESIGN CONSULTATION. Canisius College Sport Hall HEAT INSULATION THERMAL COMFORT DESIGN CONSULTATION Canisius College Sport Hall OUTLINE Pendahuluan Teori Hasil Pengukuran Hipotesa Permasalahan & Solusi Rekomendasi Disain & Simulasi Kesimpulan & Saran

Lebih terperinci

III. METODE PENELITIAN. Agar efisiensi operasi AC maximum, masing-masing komponen AC harus

III. METODE PENELITIAN. Agar efisiensi operasi AC maximum, masing-masing komponen AC harus III. METODE PENELITIAN A. Metode Penelitian Agar efisiensi operasi AC maximum, masing-masing komponen AC harus beroperasi pada tingkat efisiensi optimalnya. Untuk mempertahankan agar kinerja operasi selalu

Lebih terperinci

ANALISA PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR TENAGA (STUDI KASUS TRAFO GTG 1.3 PLTGU TAMBAK LOROK SEMARANG)

ANALISA PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR TENAGA (STUDI KASUS TRAFO GTG 1.3 PLTGU TAMBAK LOROK SEMARANG) ANALISA PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR TENAGA (STUDI KASUS TRAFO GTG 1.3 PLTGU TAMBAK LOROK SEMARANG) oleh: Nama : Purnama Sigid NIM : LF306046 Abstrak - Transformator Tenaga didesain

Lebih terperinci

ANALISIS PERPINDAHAN PANAS PADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGER DI SEKTOR PEMBANGKITAN PLTGU CILEGON

ANALISIS PERPINDAHAN PANAS PADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGER DI SEKTOR PEMBANGKITAN PLTGU CILEGON EKSERGI Jurnal Teknik Energi Vol 10 No. 3 September 2014; 78-83 ANALISIS PERPINDAHAN PANAS PADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGER DI SEKTOR PEMBANGKITAN PLTGU CILEGON F. Gatot Sumarno, Slamet

Lebih terperinci

Laporan Evaluasi Kelayakan Capacitor Bank Untuk Pemasangan ESP. Oleh : Saiful Adib

Laporan Evaluasi Kelayakan Capacitor Bank Untuk Pemasangan ESP. Oleh : Saiful Adib aporan Evaluasi Kelayakan apacitor Bank Untuk Pemasangan EP Oleh : aiful Adib UNIT BINI PT. PERTAMINA-EP (UBEP) ANGAANGA & TARAKAN FIED ANGAANGA 009 Evaluasi Kelayakan apacitor Bank Untuk Pemasangan EP

Lebih terperinci

Analisa Perancangan Gardu Induk Sistem Outdoor 150 kv di Tallasa, Kabupaten Takalar, Sulawesi Selatan

Analisa Perancangan Gardu Induk Sistem Outdoor 150 kv di Tallasa, Kabupaten Takalar, Sulawesi Selatan JURNAL DIMENSI TEKNIK ELEKTRO Vol. 1, No. 1, (2013) 37-42 37 Analisa Perancangan Gardu Induk Sistem Outdoor 150 kv di Tallasa, Kabupaten Takalar, Sulawesi Selatan Samuel Marco Gunawan, Julius Santosa Jurusan

Lebih terperinci

BAB 10. Proteksi relay / peralatan yang digunakan tergantung pada ukuran, kepentingan dan konstruksi (tekan changer jenis) dari trafo.

BAB 10. Proteksi relay / peralatan yang digunakan tergantung pada ukuran, kepentingan dan konstruksi (tekan changer jenis) dari trafo. MINGGU XII Transformer protection Types of protection Thermal Overload protection Over-flux protection BAB 10 10.1 Proteksi Transformator Transformator daya yang paling mahal yaitu elemen tunggal sistem

Lebih terperinci

BAB II LANDASAN TEORI

BAB II LANDASAN TEORI BAB II LANDASAN TEORI 2.1 Definisi Transformator Transformator atau transformer atau trafo adalah suatu peralatan listrik elektromagnetik statis yang berfungsi untuk memindah dan mengubah energi listrik

Lebih terperinci

PERPINDAHAN PANASPADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGERDI SEKTOR PEMBANGKITAN PLTGU CILEGON

PERPINDAHAN PANASPADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGERDI SEKTOR PEMBANGKITAN PLTGU CILEGON EKSERGI Jurnal Teknik Energi Vol 11 No. 3 September 2015; 85-90 PERPINDAHAN PANASPADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGERDI SEKTOR PEMBANGKITAN PLTGU CILEGON F. Gatot Sumarno, Slamet Priyoatmojo

Lebih terperinci

MODUL V-B PEMBANGKIT LISTRIK TENAGA GAS

MODUL V-B PEMBANGKIT LISTRIK TENAGA GAS 1 MODUL V-B PEMBANGKIT LISTRIK TENAGA GAS 2 DEFINISI PLTG Pembangkit Listrik Tenaga Gas (PLTG) merupakan sebuah pembangkit energi listrik yang menggunakan peralatan/mesin turbin gas sebagai penggerak generatornya.

Lebih terperinci

STUDI PERKIRAAN UMUR TRANSFORMATOR DISTRIBUSI 160 kva MENGGUNAKAN METODE TINGKAT TAHUNAN PADA PT.PLN (PERSERO) APJ CIREBON

STUDI PERKIRAAN UMUR TRANSFORMATOR DISTRIBUSI 160 kva MENGGUNAKAN METODE TINGKAT TAHUNAN PADA PT.PLN (PERSERO) APJ CIREBON STUDI PERKIRAAN UMUR TRANSFORMATOR DISTRIBUSI 160 kva MENGGUNAKAN METODE TINGKAT TAHUNAN PADA PT.PLN (PERSERO) APJ CIREBON Anggi Adipriyatna Mahasiswa Jurusan Teknik Elektro Universitas 17 Agustus 1945

Lebih terperinci

LAPORAN KERJA PRAKTEK 1 JURUSAN TEKNIK KIMIA FAKULTAS TEKNOLOGI INDUSTRI INSTITUT TEKNOLOGI SEPULUH NOPEMBER SURABAYA

LAPORAN KERJA PRAKTEK 1 JURUSAN TEKNIK KIMIA FAKULTAS TEKNOLOGI INDUSTRI INSTITUT TEKNOLOGI SEPULUH NOPEMBER SURABAYA BAB I PENDAHULUAN I.1. Latar Belakang Alat penukar kalor (Heat Exchanger) merupakan suatu peralatan yang digunakan untuk menukarkan energi dalam bentuk panas antara fluida yang berbeda temperatur yang

Lebih terperinci

ABSTRAK. Kata kunci : Kondisi tanpa Harmonisa, Kondisi dengan Harmonisa, Harmonic Analysis Load Flow, Rugi Daya, Sistem Tegangan Rendah.

ABSTRAK. Kata kunci : Kondisi tanpa Harmonisa, Kondisi dengan Harmonisa, Harmonic Analysis Load Flow, Rugi Daya, Sistem Tegangan Rendah. ABSTRAK Penyulang Menjangan merupakan sistem jaringan tegangan menengah 20 kv yang melayani daerah Gilimanuk dan sebagian Buleleng. Penyulang Menjangan memiliki total gardu terpasang sebanyak 69 Gardu,

Lebih terperinci

ANALISA PERFORMANSI COOLER LUBE OIL DENGAN KAPASITAS 300 TON/JAM PADA UNIT 2 DI PLTU LABUHAN ANGIN LAPORAN TUGAS AKHIR

ANALISA PERFORMANSI COOLER LUBE OIL DENGAN KAPASITAS 300 TON/JAM PADA UNIT 2 DI PLTU LABUHAN ANGIN LAPORAN TUGAS AKHIR ANALISA PERFORMANSI COOLER LUBE OIL DENGAN KAPASITAS 300 TON/JAM PADA UNIT 2 DI PLTU LABUHAN ANGIN LAPORAN TUGAS AKHIR Diajukan untuk Memenuhi Sebagian Persyaratan dalam Menyelesaikan Program Pendidikan

Lebih terperinci

KATA PENGANTAR Analisis Penggunaan Bahan Bakar dengan Fluktuasi Beban pada Mesin Gas Rolls Royce Kapasitas 8,5 MW di PLTMG Panaran-Batam

KATA PENGANTAR Analisis Penggunaan Bahan Bakar dengan Fluktuasi Beban pada Mesin Gas Rolls Royce Kapasitas 8,5 MW di PLTMG Panaran-Batam KATA PENGANTAR Puji dan syukur penulis ucapkan kepada Tuhan Yang Maha Esa atas rahmat dan karunia yang diberikan-nya kepada penulis sehingga dapat menyelesaikan Tugas Akhir ini, mulai dari awal penyusunan

Lebih terperinci

MAKALAH SEMINAR TUGAS AKHIR PERANCANGAN TRANSFORMATOR DAYA SATU FASA CORE TYPE DENGAN BANTUAN PC

MAKALAH SEMINAR TUGAS AKHIR PERANCANGAN TRANSFORMATOR DAYA SATU FASA CORE TYPE DENGAN BANTUAN PC MAKALAH SEMINAR TUGAS AKHIR PERANCANGAN TRANSFORMATOR DAYA SATU FASA CORE TYPE DENGAN BANTUAN PC CATUR WIDIATMOKO L2F301431 Jurusan Teknik Elektro Fakultas Teknik Universitas Diponegoro Semarang 2004 ABSTRAK

Lebih terperinci

PENGUJIAN ISOLASI MINYAK TROFO TEGANGAN TINGGI TERHADAP PERUBAHAN SUHU.

PENGUJIAN ISOLASI MINYAK TROFO TEGANGAN TINGGI TERHADAP PERUBAHAN SUHU. PENGUJIAN ISOLASI MINYAK TROFO TEGANGAN TINGGI TERHADAP PERUBAHAN SUHU Slamet Hani 1 1 Jurusan Teknik Elektro Institut Sains & Teknologi AKPRIND Yogyakarta, e-mail : shani.akprind.@yahoo.com ABSTRACT Transformer

Lebih terperinci

BAB I PENDAHULUAN. Pembangkit Listrik Tenaga Air Panglima Besar Soedirman. mempunyai tiga unit turbin air tipe Francis poros vertikal, yang

BAB I PENDAHULUAN. Pembangkit Listrik Tenaga Air Panglima Besar Soedirman. mempunyai tiga unit turbin air tipe Francis poros vertikal, yang BAB I PENDAHULUAN 1.1. Latar Belakang Pembangkit Listrik Tenaga Air Panglima Besar Soedirman mempunyai tiga unit turbin air tipe Francis poros vertikal, yang digunakan sebagai penggerak mula dari generator

Lebih terperinci

Bab III Penilaian Kondisi

Bab III Penilaian Kondisi Bab III Penilaian Kondisi 3.1. Latar Belakang Penggunaan Penilaian Kondisi 3.1.1. Pengertian Penilaian Kondisi Penilaian Kondisi merupakan suatu metode penilaian terhadap suatu obyek yang berdasarkan pada

Lebih terperinci

COOLING SYSTEM ( Sistim Pendinginan )

COOLING SYSTEM ( Sistim Pendinginan ) COOLING SYSTEM ( Sistim Pendinginan ) Adalah sistim dalam engine diesel yang berfungsi: 1. Mendinginkan engine untuk mencegah Over Heating.. 2. Memelihara suhu kerja engine. 3. Mempercepat dan meratakan

Lebih terperinci

Informasi Data Pokok Kota Surabaya Tahun 2012 BAB I GEOGRAFIS CHAPTER I GEOGRAPHICAL CONDITIONS

Informasi Data Pokok Kota Surabaya Tahun 2012 BAB I GEOGRAFIS CHAPTER I GEOGRAPHICAL CONDITIONS BAB I GEOGRAFIS CHAPTER I GEOGRAPHICAL CONDITIONS Indonesia sebagai negara tropis, oleh karena itu kelembaban udara nya sangat tinggi yaitu sekitar 70 90% (tergantung lokasi - lokasi nya). Sedangkan, menurut

Lebih terperinci

Evaluasi Performa Lube Oil Cooler pada Turbin Gas dengan Variasi Surface Designation dan Reynolds Number

Evaluasi Performa Lube Oil Cooler pada Turbin Gas dengan Variasi Surface Designation dan Reynolds Number Evaluasi Performa Lube Oil Cooler pada Turbin Gas dengan Variasi Surface Designation dan Reynolds Number Siti Duratun Nasiqiati Rosady 1), Bambang Arip Dwiyantoro 2) 1) Program Studi Pascasarjana Teknik

Lebih terperinci

PENGUJIAN THERMOELECTRIC GENERATOR (TEG) DENGAN SUMBER KALOR ELECTRIC HEATER 60 VOLT MENGGUNAKAN AIR PENDINGIN PADA TEMPERATUR LINGKUNGAN

PENGUJIAN THERMOELECTRIC GENERATOR (TEG) DENGAN SUMBER KALOR ELECTRIC HEATER 60 VOLT MENGGUNAKAN AIR PENDINGIN PADA TEMPERATUR LINGKUNGAN PENGUJIAN THERMOELECTRIC GENERATOR (TEG) DENGAN SUMBER KALOR ELECTRIC HEATER 6 VOLT MENGGUNAKAN AIR PENDINGIN PADA TEMPERATUR LINGKUNGAN Nugrah Suryanto 1, Azridjal Aziz 2, Rahmat Iman Mainil 3 Laboratorium

Lebih terperinci

BAB II TRANSFORMATOR DISTRIBUSI DAN SISTEM PENGAMANNYA

BAB II TRANSFORMATOR DISTRIBUSI DAN SISTEM PENGAMANNYA BAB II TRANSFORMATOR DISTRIBUSI DAN SISTEM PENGAMANNYA BAB II TRANSFORMATOR DISTRIBUSI DAN SISTEM PENGAMANNYA 2.1 Umum Transformator merupakan suatu perangkat listrik yang berfungsi untuk mentransformasikan

Lebih terperinci

BAB III 1 METODE PENELITIAN

BAB III 1 METODE PENELITIAN 17 BAB III 1 METODE PENELITIAN 1.1 Prosedur Penelitian Prosedur yang dilakukan dalam penelitian ini terdiri dari beberapa langkah. Langkah pertama, yaitu melakukan studi literatur dari berbagi sumber terkait.

Lebih terperinci

BAB II TRANSFORMATOR DISTRIBUSI DAN SISTEM PENGAMANNYA

BAB II TRANSFORMATOR DISTRIBUSI DAN SISTEM PENGAMANNYA BAB II TRANSFORMATOR DISTRIBUSI DAN SISTEM PENGAMANNYA 2.1 Umum Transformator merupakan suatu perangkat listrik yang berfungsi untuk mentransformasikan tegangan dan arus dari sisi primer ke sisi sekunder

Lebih terperinci

BAB III SPESIFIKASI TRANSFORMATOR DAN SWITCH GEAR

BAB III SPESIFIKASI TRANSFORMATOR DAN SWITCH GEAR 38 BAB III SPESIFIKASI TRANSFORMATOR DAN SWITCH GEAR 3.1 Unit Station Transformator (UST) Sistem PLTU memerlukan sejumlah peralatan bantu seperti pompa, fan dan sebagainya untuk dapat membangkitkan tenaga

Lebih terperinci

CURRENT TRANSFORMER DAN POTENSIAL TRANSFORMER

CURRENT TRANSFORMER DAN POTENSIAL TRANSFORMER CURRENT TRANSFORMER DAN POTENSIAL TRANSFORMER Apa yang dilakukan oleh Trafo Pengukuran? - Mengukur Arus dan Tegangan di Transmisi Tegangan Tinggi dan Switchgears dalam keadaan normal maupun gangguan -

Lebih terperinci

BAB I PENDAHULUAN A. Latar Belakang Masalah

BAB I PENDAHULUAN A. Latar Belakang Masalah BAB I PENDAHULUAN A. Latar Belakang Masalah Isolasi memiliki peranan penting pada sistem tenaga listrik. Isolasi melindungi sistem tenaga listrik dari gangguan seperti lompatan listrik atau percikan, isolasi

Lebih terperinci

STUDI EKSPERIMENTAL UNJUK KERJA RADIATOR PADA SUMBER ENERGI PANAS PADA RANCANG BANGUN SIMULASI ALAT PENGERING

STUDI EKSPERIMENTAL UNJUK KERJA RADIATOR PADA SUMBER ENERGI PANAS PADA RANCANG BANGUN SIMULASI ALAT PENGERING JURNAL LOGIC. VOL. 17. NO. 2. JULI 2017 104 STUDI EKSPERIMENTAL UNJUK KERJA RADIATOR PADA SUMBER ENERGI PANAS PADA RANCANG BANGUN SIMULASI ALAT PENGERING I Kadek Ervan Hadi Wiryanta Jurusan Teknik Mesin

Lebih terperinci

Sela Batang Sela batang merupakan alat pelindung surja yang paling sederhana tetapi paling kuat dan kokoh. Sela batang ini jarang digunakan pad

Sela Batang Sela batang merupakan alat pelindung surja yang paling sederhana tetapi paling kuat dan kokoh. Sela batang ini jarang digunakan pad 23 BAB III PERALATAN PROTEKSI TERHADAP TEGANGAN LEBIH 3.1 Pendahuluan Gangguan tegangan lebih yang mungkin terjadi pada Gardu Induk dapat disebabkan oleh beberapa sumber gangguan tegangan lebih. Perlindunga

Lebih terperinci

ANALISA PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR TENAGA (STUDI KASUS TRAFO GTG 1.3 PLTGU TAMBAK LOROK SEMARANG) Purnama Sigid L2F

ANALISA PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR TENAGA (STUDI KASUS TRAFO GTG 1.3 PLTGU TAMBAK LOROK SEMARANG) Purnama Sigid L2F ANALISA PENGARUH PEMBEBANAN TERHADAP SUSUT UMUR TRANSFORMATOR TENAGA (STUDI KASUS TRAFO GTG.3 PLTGU TAMBAK LOROK SEMARANG) Tugas Akhir Untuk memenuhi sebagian persyaratan mencapai derajat Sarjana Teknik

Lebih terperinci

BAB IV ANALISA DAN PEMBAHASAN. 1.1 Studi Kasus. PT Mayora Tbk merupakan salah satu pelanggan PT PLN

BAB IV ANALISA DAN PEMBAHASAN. 1.1 Studi Kasus. PT Mayora Tbk merupakan salah satu pelanggan PT PLN 1 BAB IV ANALISA DAN PEMBAHASAN 1.1 Studi Kasus PT Mayora Tbk merupakan salah satu pelanggan PT PLN (Persero) Distribusi Banten Area Cikokol. Yang dilayani oleh gardu distribusi TG 175 penyulang Canon

Lebih terperinci

BAB II TINJAUAN PUSTAKA

BAB II TINJAUAN PUSTAKA BAB II TINJAUAN PUSTAKA 2.1 TRANSFORMATOR 2.1.1 UMUM Transformator (trafo) merupakan peralatan mesin listrik stasis yang bekerja berdasarkan prinsip induksi elektromagnetik, yang dapat mentransformasikan

Lebih terperinci

KAJIAN PROTEKSI MOTOR 200 KW,6000 V, 50 HZ DENGAN SEPAM SERI M41

KAJIAN PROTEKSI MOTOR 200 KW,6000 V, 50 HZ DENGAN SEPAM SERI M41 Jurnal ELTEK, Vol 12 Nomor 01, April 2014 ISSN 1693-4024 KAJIAN PROTEKSI MOTOR 200 KW,6000 V, 50 HZ DENGAN SEPAM 1000+ SERI M41 Heri Sungkowo 1 Abstrak SEPAM (System Electronic Protection Automation Measurement)1000+

Lebih terperinci

VOLTAGE REGULATION. PENGATURAN TEGANGAN Oleh: Dian Retno Sawitri

VOLTAGE REGULATION. PENGATURAN TEGANGAN Oleh: Dian Retno Sawitri VOLTAGE REGULATION PENGATURAN TEGANGAN Oleh: Dian Retno Sawitri PENDAHULUAN Tegangan yang dikirim ke pelanggan harus memiliki rentang tertentu sehingga perlu dilakukan pengaturan. Dalam saluran distribusi,

Lebih terperinci

BAB III. CIRCUIT BREAKER DAN FUSE (SEKERING)

BAB III. CIRCUIT BREAKER DAN FUSE (SEKERING) BAB III. CIRCUIT BREAKER DAN FUSE (SEKERING) 3.1. Circuit Breaker Circuit breaker seperti halnya sekering adalah merupakan alat proteksi, walaupun circuit breaker dilengkapi dengan fasilitas untuk switching.

Lebih terperinci

Session 4. Diesel Power Plant. 1. Siklus Otto dan Diesel 2. Prinsip PLTD 3. Proses PLTD 4. Komponen PLTD 5. Kelebihan dan Kekurangan PLTD

Session 4. Diesel Power Plant. 1. Siklus Otto dan Diesel 2. Prinsip PLTD 3. Proses PLTD 4. Komponen PLTD 5. Kelebihan dan Kekurangan PLTD Session 4 Diesel Power Plant 1. Siklus Otto dan Diesel 2. Prinsip PLTD 3. Proses PLTD 4. Komponen PLTD 5. Kelebihan dan Kekurangan PLTD Siklus Otto Four-stroke Spark Ignition Engine. Siklus Otto 4 langkah

Lebih terperinci

Pengujian Performa Sistem Pendingin Absorpsi dengan Energi Panas Matahari di Universitas Indonesia Depok

Pengujian Performa Sistem Pendingin Absorpsi dengan Energi Panas Matahari di Universitas Indonesia Depok Pengujian Performa Sistem Pendingin Absorpsi dengan Energi Panas Matahari di Universitas Indonesia Depok M.I.Alhamid1,a, Harinaldi1,b, Nasruddin1,c, Budihardjo1,d, Arnas Lubis1,f, Yusvardi Yusuf2,e* 1.

Lebih terperinci

Heat Energy Harvesting untuk Sumber Listrik DC Skala Kecil

Heat Energy Harvesting untuk Sumber Listrik DC Skala Kecil Jurnal Integrasi Vol. 9 No. 1, April 2017, 80-83 e-issn: 2548-9828 Article History Received March, 2017 Accepted April, 2017 Heat Energy Harvesting untuk Sumber Listrik DC Skala Kecil Arif Febriansyah

Lebih terperinci

Session 9. Generator, Motor, and Transformator. 1.Generator 2.Motor 3.Transformator

Session 9. Generator, Motor, and Transformator. 1.Generator 2.Motor 3.Transformator Session 9 Generator, Motor, and Transformator 1.Generator 2.Motor 3.Transformator 1. Generator Konsep Dasar Klasifikasi Generator Power Generator menghasilkan tenaga listrik (arus besar) untuk didistribusikan

Lebih terperinci

SOLUSI SUPLAI AIR PENDINGIN UNTUK KOMPLEK INDUSTRI PADAT DI TEPI PANTAI Oleh: Muchlis Nugroho Pasaman&Soeparman Chemical Engineer, PT

SOLUSI SUPLAI AIR PENDINGIN UNTUK KOMPLEK INDUSTRI PADAT DI TEPI PANTAI Oleh: Muchlis Nugroho Pasaman&Soeparman Chemical Engineer, PT SOLUSI SUPLAI AIR PENDINGIN UNTUK KOMPLEK INDUSTRI PADAT DI TEPI PANTAI Oleh: Muchlis Nugroho Pasaman&Soeparman Chemical Engineer, PT Latar Belakang Lokasi pabrik PT. Kaltim Parna Industri (produsen ammonia)

Lebih terperinci

BAB IV HASIL DAN PEMBAHASAN

BAB IV HASIL DAN PEMBAHASAN 44 BAB IV HASIL DAN PEMBAHASAN 4.1 PENDAHULUAN Pada bab ini akan dilakukan perhitungan beban pendinginan (cooling load) dari hasil pengumpulan data di lapangan untuk mengetahui parameter yang dibutuhkan

Lebih terperinci

BAB III SISTEM KELISTRIKAN DAN PROTEKSI

BAB III SISTEM KELISTRIKAN DAN PROTEKSI BAB III SISTEM KELISTRIKAN DAN PROTEKSI 3.1 Generator dan Transformator Unit Generator Suatu alat listrik yang merubah energi gerak berupa putaran dari turbin yang dipasang seporos dengan generator, kemudian

Lebih terperinci

ANALISIS DETEKSI KEADAAN MINYAK TRANSFORMATOR DENGAN METODE GAS TERLARUT MENGGUNAKAN PERALATAN DISSOLVE GAS ANALISYS ( DGA)

ANALISIS DETEKSI KEADAAN MINYAK TRANSFORMATOR DENGAN METODE GAS TERLARUT MENGGUNAKAN PERALATAN DISSOLVE GAS ANALISYS ( DGA) ANALISIS DETEKSI KEADAAN MINYAK TRANSFORMATOR DENGAN METODE GAS TERLARUT MENGGUNAKAN PERALATAN DISSOLVE GAS ANALISYS ( DGA) SURYA DARMA Dosen Tetap Yayasan Pada Program Studi Teknik Elektro Fakultas Teknik

Lebih terperinci

Modul Pelatihan etap 6.0.0 Jurusan Teknik Elektro Universitas Muhamadiyah Yogyakarta. by Lukita Wahyu P, Reza Bakhtiar

Modul Pelatihan etap 6.0.0 Jurusan Teknik Elektro Universitas Muhamadiyah Yogyakarta. by Lukita Wahyu P, Reza Bakhtiar Modul Pelatihan etap 6.0.0 Jurusan Teknik Elektro Universitas Muhamadiyah Yogyakarta by Lukita Wahyu P, Reza Bakhtiar UNIT 1 PENGENALAN ETAP 1. TUJUAN PRAKTIKUM a. Mengetahui fungsi software ETAP 6.0.0

Lebih terperinci

PENGERINGAN KACANG TANAH DENGAN PENERAPAN DCS PADA ROTARY DRYER

PENGERINGAN KACANG TANAH DENGAN PENERAPAN DCS PADA ROTARY DRYER LAPORAN TUGAS AKHIR PENGERINGAN KACANG TANAH DENGAN PENERAPAN DCS PADA ROTARY DRYER (PEANUT DRYING WITH THE IMPLEMENTATION OF DCS IN THE ROTARY DRYER) Diajukan sebagai salah satu syarat untuk menyelesaikan

Lebih terperinci

Kampus Bina Widya Jl. HR. Soebrantas Km 12,5 Pekanbaru, Kode Pos Abstract

Kampus Bina Widya Jl. HR. Soebrantas Km 12,5 Pekanbaru, Kode Pos Abstract ANALISIS EVAPORATIVE AIR COOLER DENGAN TEMPERATUR MEDIA PENDINGIN YANG BERBEDA Hendra Listiono 1, Azridjal Aziz 2, Rahmat Iman Mainil 3 1 Mahasiswa Jurusan Teknik Mesin, Fakultas Teknik, Universitas Riau

Lebih terperinci

BAB III SISTEM PLTGU UBP TANJUNG PRIOK

BAB III SISTEM PLTGU UBP TANJUNG PRIOK BAB III SISTEM PLTGU UBP TANJUNG PRIOK 3.1 Konfigurasi PLTGU UBP Tanjung Priok Secara sederhana BLOK PLTGU UBP Tanjung Priok dapat digambarkan sebagai berikut: deaerator LP Header Low pressure HP header

Lebih terperinci

ANALISIS GANGGUAN HUBUNG SINGKAT TRAFO TENAGA 60 MVA SHORT CIRCUIT ANALYSIS OF POWER TRANSFORMER 60 MVA

ANALISIS GANGGUAN HUBUNG SINGKAT TRAFO TENAGA 60 MVA SHORT CIRCUIT ANALYSIS OF POWER TRANSFORMER 60 MVA Techno, ISSN 1410-8607 Volume 16 No. 2, Oktober 2015 Hal. 125 130 ANALISIS GANGGUAN HUBUNG SINGKAT TRAFO TENAGA 60 MVA SHORT CIRCUIT ANALYSIS OF POWER TRANSFORMER 60 MVA Eka Purwito dan Fitrizawati* Program

Lebih terperinci

Makalah Seminar Kerja Praktek PEMELIHARAAN TRANSFORMATOR BAGIAN RAT PLTU UNIT 3 PT. INDONESIA POWER UP SEMARANG

Makalah Seminar Kerja Praktek PEMELIHARAAN TRANSFORMATOR BAGIAN RAT PLTU UNIT 3 PT. INDONESIA POWER UP SEMARANG Makalah Seminar Kerja Praktek PEMELIHARAAN TRANSFORMATOR BAGIAN RAT PLTU UNIT 3 PT. INDONESIA POWER UP SEMARANG Akbar Rama Dhanara. 1, Ir. Tejo Sumakdi, MT. 2 1 Mahasiswa dan 2 Dosen Jurusan Teknik Elektro,

Lebih terperinci

BAB IV PERHITUNGAN DAN PERANCANGAN BEBAN PENDINGIN 4.1 PERHITUNGAN SECARA MANUAL DAN TEORISTIS

BAB IV PERHITUNGAN DAN PERANCANGAN BEBAN PENDINGIN 4.1 PERHITUNGAN SECARA MANUAL DAN TEORISTIS 56 BAB IV PERHITUNGAN DAN PERANCANGAN BEBAN PENDINGIN 4.1 PERHITUNGAN SECARA MANUAL DAN TEORISTIS Perhitungan beban thermal secara manual dan teoristis merupakan prinsip dasar. Beban termal pada sebuah

Lebih terperinci

Bab I Pendahuluan Latar Belakang

Bab I Pendahuluan Latar Belakang Bab I Pendahuluan 1.1. Latar Belakang Sistem pemanas dengan prinsip perpindahan panas konveksi, konduksi dan radiasi adalah teknologi yang umum kita jumpai dalam kehidupan seharihari, baik alat pemanas

Lebih terperinci

BAB V KESIMPULAN DAN SARAN. Sebagai strategi passive cooling dengan prinsip ventilasi, strategi night

BAB V KESIMPULAN DAN SARAN. Sebagai strategi passive cooling dengan prinsip ventilasi, strategi night BAB V KESIMPULAN DAN SARAN 5.1. Kesimpulan Sebagai strategi passive cooling dengan prinsip ventilasi, strategi night ventilative cooling masih kurang dikenal di Indonesia. Dalam riset-riset terdahulu,

Lebih terperinci

BAB III PENGAMBILAN DATA

BAB III PENGAMBILAN DATA BAB III PENGAMBILAN DATA Didalam pengambilan data pada skripsi ini harus di perhatikan beberapa hal sebagai berikut : 3.1 PEMILIHAN TRANSFORMATOR Pemilihan transformator kapasitas trafo distribusi berdasarkan

Lebih terperinci

ANALISIS KETIDAKSEIMBANGAN BEBAN TRAFO 1 GI SRONDOL TERHADAP RUGI-RUGI AKIBAT ARUS NETRAL DAN SUHU TRAFO MENGGUNAKAN ETAP

ANALISIS KETIDAKSEIMBANGAN BEBAN TRAFO 1 GI SRONDOL TERHADAP RUGI-RUGI AKIBAT ARUS NETRAL DAN SUHU TRAFO MENGGUNAKAN ETAP ANALISIS KETIDAKSEIMBANGAN BEBAN TRAFO 1 GI SRONDOL TERHADAP RUGI-RUGI AKIBAT ARUS NETRAL DAN SUHU TRAFO MENGGUNAKAN ETAP 12.6.0 Dennis Satria Wahyu Jayabadi *), Bambang Winardi, and Mochammad Facta Departemen

Lebih terperinci

2.10 Caesar II. 5.10Pipe Strees Analysis

2.10 Caesar II. 5.10Pipe Strees Analysis 2.8 Pipe Support Karena pipa dipengaruhi oleh ekspansi termal. Mendukung dalam sebuah langkah sistem perpipaan termal dalam arah yang berbeda. Pipe support oleh dua jenis support-kaku (rigid support) dan

Lebih terperinci

Rifgy Said Bamatraf Dosen Pembimbing Dr. Ir. Margo Pujiantara, MT Dr. Dedet Chandra Riawan, ST., M.Eng.

Rifgy Said Bamatraf Dosen Pembimbing Dr. Ir. Margo Pujiantara, MT Dr. Dedet Chandra Riawan, ST., M.Eng. Rifgy Said Bamatraf 2207100182 Dosen Pembimbing Dr. Ir. Margo Pujiantara, MT Dr. Dedet Chandra Riawan, ST., M.Eng. Latar Belakang Masalah Batasan Masalah Sistem Kelistrikan PLTU dan PLTG Unit Pembangkit

Lebih terperinci

PERANCANGAN HEAT EXCHANGER

PERANCANGAN HEAT EXCHANGER One Shell Pass and One Tube Pass PERANCANGAN HEAT EXCHANGER Abdul Wahid Surhim Pengertian HE adalah alat yang berfungsi sebagai alat penukar panas (kalor) Dilihat dari fungsinya dapat dinamakan : Pemanas

Lebih terperinci

PEMAKAIAN DAN PEMELIHARAAN TRANSFORMATOR ARUS (CURRENT TRANSFORMER / CT)

PEMAKAIAN DAN PEMELIHARAAN TRANSFORMATOR ARUS (CURRENT TRANSFORMER / CT) PEMAKAIAN DAN PEMELIHARAAN TRANSFORMATOR ARUS (CURRENT TRANSFORMER / CT) Oleh : Agus Sugiharto Abstrak Seiring dengan berkembangnya dunia industri di Indonesia serta bertambah padatnya aktivitas masyarakat,

Lebih terperinci

SATUAN ACARA PERKULIAHAN TEKNIK ELEKTRO ( IB ) MATA KULIAH / SEMESTER : TRANSFORMATOR / 8 KODE / SKS / SIFAT : AK041437/ 4 SKS / PILIHAN

SATUAN ACARA PERKULIAHAN TEKNIK ELEKTRO ( IB ) MATA KULIAH / SEMESTER : TRANSFORMATOR / 8 KODE / SKS / SIFAT : AK041437/ 4 SKS / PILIHAN SATUAN ACARA PERKULIAHAN TEKNIK ELEKTRO ( IB ) MATA KULIAH / SEMESTER : TRANSFORMATOR / 8 KODE / SKS / SIFAT : AK041437/ 4 SKS / PILIHAN Pertemuan Pokok Bahasan & ke TIU 1 Review teori elektro maknit mekanik

Lebih terperinci

BAB IV ANALISA DATA. 4.1 ETAP (Electrical Transient Analyzer Program) Vista, 7, dan 8. ETAP merupakan alat analisa yang komprehensif untuk

BAB IV ANALISA DATA. 4.1 ETAP (Electrical Transient Analyzer Program) Vista, 7, dan 8. ETAP merupakan alat analisa yang komprehensif untuk BAB IV ANALISA DATA 4.1 ETAP (Electrical Transient Analyzer Program) ETAP merupakan program analisa grafik transient kelistrikan yang dapat dijalankan dengan menggunakan program Microsoft Windows 2000,

Lebih terperinci

VOLTAGE REGULATION. PENGATURAN TEGANGAN Oleh: Dian Retno Sawitri

VOLTAGE REGULATION. PENGATURAN TEGANGAN Oleh: Dian Retno Sawitri VOLTAGE REGULATION PENGATURAN TEGANGAN Oleh: Dian Retno Sawitri PENDAHULUAN Tegangan yang dikirim ke pelanggan harus memiliki rentang tertentu sehingga perlu dilakukan pengaturan. Dalam saluran distribusi,

Lebih terperinci

BAB I PENDAHULUAN. pendukung di dalamnya masih tetap diperlukan suplai listrik sendiri-sendiri.

BAB I PENDAHULUAN. pendukung di dalamnya masih tetap diperlukan suplai listrik sendiri-sendiri. BAB I PENDAHULUAN 1.1 Latar Belakang PLTU (Pusat Listrik Tenaga Uap) Suralaya mampu membangkitkan listrik berkapasitas 3400 MW dengan menggunakan tenaga uap. Tetapi perlu diketahui bahwa di dalam proses

Lebih terperinci

ANALISIS EFEKTIFITAS ALAT PENUKAR KALOR SHELL & TUBE DENGAN MEDIUM AIR SEBAGAI FLUIDA PANAS DAN METHANOL SEBAGAI FLUIDA DINGIN

ANALISIS EFEKTIFITAS ALAT PENUKAR KALOR SHELL & TUBE DENGAN MEDIUM AIR SEBAGAI FLUIDA PANAS DAN METHANOL SEBAGAI FLUIDA DINGIN ANALISIS EFEKTIFITAS ALAT PENUKAR KALOR SHELL & TUBE DENGAN MEDIUM AIR SEBAGAI FLUIDA PANAS DAN METHANOL SEBAGAI FLUIDA DINGIN SKRIPSI Skripsi Yang Diajukan Untuk Melengkapi Syarat Memperoleh Gelar Sarjana

Lebih terperinci

WIKA HEAT PUMP WATER HEATER FOR SWIMMING POOL / JACUZZI

WIKA HEAT PUMP WATER HEATER FOR SWIMMING POOL / JACUZZI WIKA HEAT PUMP WATER HEATER FOR SWIMMING POOL / JACUZZI ISO 9001 PT. WIJAYA KARYA INDUSTRI ENERGI JAKARTA INDONESIA DISTRIBUTED By CV. LINGGOJATI UTAMA Jl.Pulomas III No.5A Jakarta Timur, Telp : 4788.4444.

Lebih terperinci

BAB III PERALATAN LISTRIK PADA MOTOR CONTROL CENTER (MCC) WATER TREATMENT PLANT (WTP) 3

BAB III PERALATAN LISTRIK PADA MOTOR CONTROL CENTER (MCC) WATER TREATMENT PLANT (WTP) 3 BAB III PERALATAN LISTRIK PADA MOTOR CONTROL CENTER (MCC) WATER TREATMENT PLANT (WTP) 3 3.1 Sistem Proteksi Kelistrikan pada Motor Control Center (MCC) Sistem proteksi kelistrikan pada motor control center

Lebih terperinci

BAB II TINJAUAN PUSTAKA

BAB II TINJAUAN PUSTAKA BAB II TINJAUAN PUSTAKA 2.1 Perpindahan Panas Panas atau kalor merupakan salah satu bentuk energi. Panas dapat berpindah dari suatu zat ke zat lain. Panas dapat berpndah melalui tiga cara yaitu : 2.1.1

Lebih terperinci