VALIDASI METODA XRF (X-RAY FLUORESCENCE) SECARA TUNGGAL DAN SIMULTAN. UNTUK ANALISIS UNSUR Mg, Mn DAN Fe DALAM PADUAN ALUMINUM

dokumen-dokumen yang mirip
PENGARUH KEVAKUMAN TERHADAP ANALISIS UNSUR TI DAN SI DALAM AlMg 2 MENGGUNAKAN XRF (X-RAY FLUORESCENCE)

PENENTUAN UNSUR PEMADU DALAM BAHAN ZIRCALOY-2 DENGAN METODE SPEKTROMETRI EMISI DAN XRF

PENGUJIAN KEMAMPUAN XRF UNTUK ANALISIS KOMPOSISI UNSUR PADUAN Zr-Sn-Cr-Fe-Ni

KONTROL KURVA KALIBRASI SPEKTROMETER EMISI DENGAN STANDAR ALUMINIUM CERTIFIED REFERENCE MATERIALS (CRM)

PERBANDINGAN METODA OTOMATIS DAN MANUAL DALAM PENENTUAN ISOTOP Cs-137 MENGGUNAKAN SPEKTROMETER GAMMA

PENENTUAN KANDUNGAN Sn, Fe, Cr, Ni DAN PENGOTOR ZIRCALOY-2 SEBAGAI BAHAN KELONGSONG DAN TUTUP UJUNG ELEMEN BAKAR REAKTOR DAYA

VALIDASI METODA PENGUKURAN ISOTOP 137 Cs MENGGUNAKAN SPEKTROMETER GAMMA

PENENTUAN KESTABILAN SPARKING SPEKTROMETER EMISI MENGGUNAKAN BAHAN PADUAN ALUMINIUM

KOMPARASI ANALISIS KOMPOSISI PADUAN AlMgSI1 DENGAN MENGGUNAKAN TEKNIK X RAY FLUOROCENCY (XRF) DAN EMISSION SPECTROSCOPY (

PENGGUNAAN METODE INTENSITAS SINAR-X KARAKTERISTIK RELATIF Cr, Mn DAN Ni TERHADAP Fe PADA ANALISIS KANDUNGAN Cr, Mn DAN Ni, DALAM PADUAN BESI

PENGARUH APLIKASI METODA STANDAR INTERNAL PADA PENENTUAN UNSUR Cr DAN Ni DALAM ZIRKALOY 2 DENGAN METODA SPEKTROMETRI EMISI

APLIKASI SPEKTROMETER EMISI PADA ANALISIS UNSUR-UNSUR BAHAN PADUAN ALUMINIUM AlMgSi-1

ANALISIS NEODIMIUM MENGGUNAKAN METODA SPEKTROFOTOMETRI UV-VIS

VALIDASI METODA ANALISIS ISOTOP U-233 DALAM STANDAR CRM MENGGUNAKAN SPEKTROMETER ALFA

ANALISIS KERUSAKAN X-RAY FLUORESENCE (XRF)

PENENTUAN KADAR URANIUM DALAM SAMPEL YELLOW CAKE MENGGUNAKAN SPEKTROMETER GAMMA

METODE ANALISIS UNTUK PENENTUAN UNSUR AS DAN SB MENGGUNAKAN ICP AES PLASMA 40

ANALISIS THORIUM MENGGUNAKAN SPEKTROFOTO METER UV-VIS

PENGUKURAN AKTIVITAS ISOTOP 152 Eu DALAM SAMPEL UJI PROFISIENSI MENGGUNAKAN SPEKTROMETER GAMMA

VALIDASI METODE ANALISIS UNSUR TANAH JARANG (Ce, Eu, Tb) DENGAN ALAT ICP-AES PLASMA 40

PENGARUH WAKTU PENGAMBILAN SAMPLING PADA ANALISIS UNSUR RADIOAKTIF DI UDARA DENGAN MENGGUNAKAN SPEKTROMETER GAMMA

OPTIMASI PENGUKURAN KEAKTIVAN RADIOISOTOP Cs-137 MENGGUNAKAN SPEKTROMETER GAMMA

UNJUK KERJA METODE FLAME ATOMIC ABSORPTION SPECTROMETRY (F-AAS) PASCA AKREDITASI

EVALUASI PENERAPAN ENERGI DISPERSIVE X-RAY FLUORESCENCE (ED-XRF) UNTUK ANALISIS COAL FLY ASH

ANALISIS UNSUR PENGOTOR Fe, Cr, DAN Ni DALAM LARUTAN URANIL NITRAT MENGGUNAKAN SPEKTROFOTOMETER SERAPAN ATOM

PENENTUAN UNSUR IMPURITAS DALAM SERBUK U 3 SI 2 DENGAN MENGGUNAKAN ALAT ICPS

VALIDASI METODA PENENTUAN UNSUR RADIOAKTIF Pb-212, Cs-137, K-40 DENGAN SPEKTROMETER GAMMA

PENCEMBANCAN METODE ANALISIS MENCCUNAKAN" ALAT ICP AES PLASMA 40 UNTUK PENENTUAN UNSUR AS DAN Sb

VERIFIKASI METODE STEP DAN KONTINYU UNTUK PENENTUAN KAPASITAS PANAS MENGGUNAKAN THERMAL ANALYZER

PENGARUH KONSENTRASI PELARUT UNTUK MENENTUKAN KADAR ZIRKONIUM DALAM PADUAN U-Zr DENGAN MENGGUNAKAN METODE SPEKTROFOTOMETRI UV-VIS

PENENTUAN ISOTOP 137 Cs DAN UNSUR Cs DALAM LARUTAN AKTIF CsNO 3

PENGUKURAN SIFAT TERMAL ALLOY ALUMINIUM FERO NIKEL MENGGUNAKAN ALAT DIFFERENTIAL THERMAL ANALYZER

KUALIFIKASI AIR TANGKI REAKTOR (ATR) KARTINI BERDASARKAN DATA DUKUNG METODA NYALA SPEKTROMETRI SERAPAN ATOM (SSA) DAN ION SELECTIVE ELECTRODE (ISE)

KUALIFIKASI AIR TANGKI REAKTOR (ATR) KARTINI BERDASARKAN DATA DUKUNG METODA NYALA SPEKTROMETRI SERAPAN ATOM (SSA) DAN ION SELECTIVE ELECTRODE (ISE)

PENENTUAN KADAR ZIRKONIUM DALAM PADUAN U-ZR MENGGUNAKAN SPEKTROFOTOMETER UV-VIS DENGAN PENGOMPLEKS ARSENAZO III

PROGRAM JAMINAN KUALITAS PADA PENGUKURAN. RADIONUKLIDA PEMANCAR GAMMA ENERGI RENDAH:RADIONUKLIDA Pb-210

VALIDASI PENGUJIAN Cr, Cu DAN Pb DENGAN METODE SPEKTROMETRI SERAPAN ATOM

PEMISAHAN RADIONUKLIDA 137 CS DENGAN METODA PENGENDAPAN CSCLO 4

BAB V HASIL DAN PEMBAHASAN

BAB IV HASIL DAN PEMBAHASAN

DAFTAR ISI.. ABSTRAK.. KATA PENGANTAR UCAPAN TERIMA KASIH. DAFTAR TABEL.. DAFTAR GAMBAR. DAFTAR LAMPIRAN..

Djoko Prakoso Dwi Atmodjo, Dadang Suryana, Hengki Wibowo. ABSTRAK

BAB 6 RINGKASAN PENELITIAN

IDENTIFIKASI LOGAM-LOGAM BERAT Fe, Cr, Mn, Mg, Ca, DAN Na DALAM AIR TANGKI REAKTOR DENGAN METODE NYALA SPEKTROMETRI SERAPAN ATOM (SAA)

ANALISIS UNSUR RADIOAKTIVITAS UDARA BUANG PADA CEROBONG IRM MENGGUNAKAN SPEKTROMETER GAMMA

EVALUASI KINERJA SPEKTROMETER GAMMA YANG MENGGUNAKAN NITROGEN CAIR SEBAGAI PENDINGIN DETEKTOR

BAB IV HASIL DAN PEMBAHASAN. 4.1 Spektrum Derivatif Metil Paraben dan Propil Paraben

PROGRAM EKSTENSI SARJANA FARMASI FAKULTAS FARMASI UNIVERSITAS SUMATERA UTARA MEDAN 2016

ANALISIS UNSUR-UNSUR PENGOTOR DALAM YELLOW CAKE DARI LIMBAH PUPUK FOSFAT SECARA SPEKTROMETRI SERAPAN ATOM

VALIDASI METODE ANALISIS AKTIVASI NEUTRON UNTUK UNSUR-UNSUR DI DALAM STANDARD REFERENCE MATERIAL. NIST 1577b BOVINE LIVER INDRIA KURNIATI PRATASIS

MAKALAH XRF (X-ray fluorescence spectrometry)

PENGARUH URANIUM TERHADAP ANALISIS THORIUM MENGGUNAKAN SPEKTROFOTOMETER UV-VIS

VALIDASI METODA SPEKTROMETRI PENDAR SINAR-X

KARAKTERISASI DIFRAKSI SINAR X DAN APLIKASINYA PADA DEFECT KRISTAL OLEH: MARIA OKTAFIANI JURUSAN FISIKA

PENGGUNAAN SINAR-X KARAKTERISTIK U-Ka2 DAN Th-Ka1 PADA ANALISIS KOMPOSISI ISOTOPIK URANIUM SECARA TIDAK MERUSAK

PENINGKATAN AKURASI DATA HRSANS DENGAN MODIFIKASI PERANGKAT LUNAK KENDALI PADA BAGIAN SAMPLE CHANGER

ANALISIS Fe, Ti DALAM PASIR BESI SECARA FLUORESENSI SINAR-X

ANALISIS KESALAHAN DALAM SPEKTROMETRI SERAPAN ATOM (SSA)

VALIDASI METODE F-AAS UNTUK MEMPEROLEH JAMINAN MUTU PADA ANALISIS UNSUR Cd, Cu, Cr, Pb, DAN Ni DALAM CONTOH UJI LIMBAH CAIR

KOMPARASI HASIL ANALISIS KOMPOSISI KIMIA DI DALAM PADUAN U-Zr-Nb DENGAN MENGGUNAKAN TEKNIK XRF DAN AAS

ANALISIS KANDVNGAN PENGOTOR DALAM PELET VOz SINTER

KALIBRASI TENAGA DAN STANDAR MENGGUNAKAN ALAT X-RAY FLUORESENCE (XRF) UNTUK ANALISIS UNSUR ZIRKONIUM DALAM MINERAL

VALIDASI METODE UNTUK ANALISIS KANDUNGAN URANIUM MENGGUNAKAN POTENSIOMETER T-90

BAB I PENDAHULUAN 1.1 Latar Belakang

UNIVERSITAS INDONESIA. X-Ray Fluoresence TULISAN ILMIAH. Muhammad Arfiadi Pratama ( ) Giri Yudho Prakoso ( )

KUALIFIKASI ALAT SPEKTROMETER UV-Vis UNTUK PENENTUAN URANIUM DAN BESI DALAM -U30S --

METODE RAPID TEST PREPARATION

PENGENDALIAN MUTU METODE NYALA SPEKTROMETRI SERAPAN ATOM (SSA) DENGAN UJI

PERBANDINGAN HASIL ANALISIS BAHAN BAKAR U-Zr DENGAN MENGGUNAKAN TEKNIK XRF DAN SSA

DISTRIBUSI LOGAM Fe, Ca, Ti, Ba, Sr, Zr dan Ce DALAM BATUBARA DAN LIMBAH PEMBAKARANNYA PLTU CILACAP MENGGUNAKAN XRF

UJIAN AKHIR SEMESTER GANJIL MATA KULIAH SPEKTOSKOPI 1. ANALISA UJI XRF (X-ray fluorescence spectrometry) PADA SAMPEL BAHAN AIR METAL (59)

KARAKTERISASI PADUAN AlFeNiMg HASIL PELEBURAN DENGAN ARC FURNACE TERHADAP KEKERASAN

EVALUASI FLUKS NEUTRON THERMAL DAN EPITHERMAL DI FASILITAS SISTEM RABBIT RSG GAS TERAS 89. Elisabeth Ratnawati, Jaka Iman, Hanapi Ali

4 Hasil dan Pembahasan

PROGRAM STUDI SARJANA FARMASI FAKULTAS FARMASI UNIVERSITAS SUMATERA UTARA MEDAN 2014

PENGARUH PENGOTOR PADA PENENTUAN BORON DALAM U 3 O 8 MENGGUNAKAN SPEKTROFLUOROMETRI LUMINESEN. Giyatmi*, Noviarty**, Sigit**

Ind. J. Chem. Res., 2016, 3(2), VALIDATION OF X-RAY FLUORECENCE METHOD FOR ION Fe ANALYSIS IN ACTIVATED METHYL DIETHANOL AMINE (amdea)

BAB IV HASIL DAN PEMBAHASAN. a. Pemilihan komposisi fase gerak untuk analisis levofloksasin secara KCKT

Jurnal Radioisotop dan Radiofarmaka ISSN Journal of Radioisotope and Radiopharmaceuticals Vol 10, Oktober 2007

ANALISIS RADIONUKLIDA 137 CS DALAM PELAT ELEMEN BAKAR (PEB) U 3 SI 2 -AL DENSITAS 2,96 G/CM 3 PASCA IRADIASI

PENAFSIRAN NILAI KETIDAKPASTIAN ANALISIS Fe, Ca, Zr, Ba, La, Ti DAN Ce DALAM CUPLIKAN SEDIMEN DENGAN METODA XRF

ANALISIS SIFAT TERMAL PADUAN AlFeNi SEBAGAI KELONGSONG BAHAN BAKAR REAKTOR RISET

PENETAPAN KADAR CAMPURAN PARASETAMOL DAN IBUPROFEN PADA SEDIAAN TABLET SECARA SPEKTROFOTOMETRI DERIVATIF DENGAN ZERO CROSSING SKRIPSI

BAB I PENDAHULUAN 1.1 Latar Belakang

III. METODOLOGI PENELITIAN

BAB IV HASIL DAN PEMBAHASAN. Linieritas metode analisis kalsium dalam tanah dengan AAS ditentukan

OPTIMISASI APLIKASI AIR FILTER UNTUK PENGUKURAN UNSUR Co, Cr, DAN Ni PADA SPEKTROMETER ENERGY DISPERSIVE X-RAY FLUORESCENCE (EDXRF) EPSILON 5

X-Ray Fluorescence Spectrometer (XRF)

SIMULASI KURVA EFISIENSI DETEKTOR GERMANIUM UNTUK SINAR GAMMA ENERGI RENDAH DENGAN METODE MONTE CARLO MCNP5

PENENTUAN NILAI LIMIT DETEKSI DAN KUANTISASI ALAT TITRASI POTENSIOMETER UNTUK ANALISIS URANIUM

BAB IV HASIL DAN PEMBAHASAN. Pengembangan metode dapat dilakukan dalam semua tahapan ataupun

PENGARUH PROSES QUENCHING TERHADAP LAJU KOROSI BAHAN BAKAR PADUAN UZr

KETIDAKPASTIAN PENGUKURAN KEKASARAN PERMUKAAN KELONGSONG BAHAN BAKAR NUKLIR DENGAN ROUGHNESS TESTER SURTRONIC-25

UNJUK KERJA METODE AANC PADA ANALISIS UNSUR Fe, Al, Zr DAN Si DALAM CUPLIKAN ZrOCl 2 HASIL OLAH PASIR ZIRKON

PEMANFAATAN GAMMA SPEKTROMETRI UNTUK PENGAMATAN DISTRIBUSI PEMBELAHAN DALAM PELAT ELEMEN BAKAR NUKLIR

KARAKTERISASI KOMPOSISI KIMIA, LUAS PERMUKAAN PORI DAN SIFAT TERMAL DARI ZEOLIT BAYAH, TASIKMALAYA, DAN LAMPUNG

KETIDAKPASTIAN PENGUKURAN ISOTOP CS-137 DALAM BAHAN BAKAR U3Sh PASCA IRRADIASI

PENGARUH PENAMBAHAN URANIUM PADA ANALISIS THORIUM SECARA SPEKTROFOTOMETRI UV-VIS DENGAN PENGOMPLEKS ARSENAZO(III)

PERHITUNGAN BURN UP BAHAN BAKAR REAKTOR RSG-GAS MENGGUNAKAN PAKET PROGRAM BATAN-FUEL. Mochamad Imron, Ariyawan Sunardi

TEKNIK VOLTAMETRI PELUCUTAN ANODIK UNTUK PENENTUAN KADAR LOGAM Pb, Cd, DAN Cu PADA AIR LAUT PELABUHAN BENOA

Transkripsi:

VALIDASI METODA XRF (X-RAY FLUORESCENCE) SECARA TUNGGAL DAN SIMULTAN UNTUK ANALISIS UNSUR Mg, Mn DAN Fe DALAM PADUAN ALUMINUM Rosika Kriswarini, Dian Anggraini, Agus Djamaludin Pusat Teknologi Bahan Bakar Nuklir (PTBN), BATAN, Gedung 20, Kawasan PUSPIPTEK Serpong, Tangerang 15313, Banten Abstrak VALIDASI METODA XRF (X-RAY FLUORESCENCE) SECARA TUNGGAL DAN SIMULTAN UNTUK ANALISIS UNSUR Mg, Mn DAN Fe DALAM PADUAN ALUMINUM. Analisis unsur Mg, Mn dan Fe dalam paduan Aluminum secara tunggal dan simultan telah dilakukan menggunakan alat Spektrometer XRF. Alat XRF di PTBN-BATAN dilengkapi dengan sample holder yang mampu untuk pengukuran 10 sampel dengan ukuran 3 cm secara simultan. Untuk mengetahui unjuk kerja secara tunggal maupun simultan dilakukan pengukuran bahan standar paduan Aluminum dengan ukuran 5 cm dan 3 cm masing-masing sebanyak 10 buah dengan konsentrasi yang bervariasi. Analisis dilakukan pada tekanan vakum 200 mtorr dan tegangan kerja 14 kvolt serta arus 90 µampere. Pengukuran secara tunggal dilakukan 7 kali pengulangan dan pengukuran secara simultan dilakukan 5 kali pengulangan. Berdasarkan perhitungan validasi metoda diperoleh bahwa akurasi penentuan unsur Mg, Mn dan Fe secara simultan lebih baik dibandingkan dengan cara tunggal, sedangkan presisi penentuan unsur Mn dan Fe lebih baik dibanding unsur Mg secara tunggal maupun simultan. Meskipun demikian berdasarkan hasil perhitungan statistik melalui uji F dan uji t kedua cara tersebut dapat digunakan untuk penentuan unsur Mg, Mn dan Fe dalam paduan Aluminum. Kata Kunci : Unsur Mg, Mn, Fe, Paduan Aluminum, XRF, Pengukuran Tunggal dan Simultan Abstract Analysis of Mg, Mn and Fe in Aluminum alloy singly and simultaneously has been performed using XRF Spectrometer. XRF instrument in PTBN-BATAN is equipped with a sample holder that is able to measure 10 samples of size 3 cm simultaneously. To determine the performance in single or simultaneous measurement Aluminum alloy standard material with a size of 5 cm and 3 cm respectively as many as 10 units with varying concentrations. Analysis was performed at 200 mtorr vacuum pressure and working voltage at 14 kvolt and current at 90 µampere. Singly measurement performed 7 times of repetition and the simultaneously measurement performed 5 times of repetition. Based on the calculation of method validation showed that the accuracy of the determination of Mg, Mn and Fe simultaneously is better than singly, while the precision determination of Mn and Fe elements better than Mg elements in single or simultaneous. However the calculations based on statistics through t test and F test, both of methods can be used for the determination of elements such as Mg, Mn and Fe in aluminum alloy. Keywords: Mg, Mn, Fe Element, Aluminum Alloy, XRF, Single and Simultaneous Measurement Rosika K., dkk 273 STTN-BATAN & Fak. Saintek UIN SUKA

PENDAHULUAN X-Ray Fluoresensi (XRF) merupakan salah satu metode analisis tidak merusak digunakan untuk analisis unsur dalam bahan secara kualitatif dan kuantitatif. Prinsip Kerja metode analisis XRF berdasarkan terjadinya tumbukan atom-atom pada permukaan sampel (bahan) oleh sinar X dari sumber sinar X [1]. Hasil analisis kualitatif ditunjukkan oleh puncak spektrum yang mewakili jenis unsur sesuai dengan energi sinar-x karakteristiknya, sedang analisis kuantitatif diperoleh dengan cara membandingkan intensitas sampel dengan standar. Dalam analisis kuantitatif, faktor-faktor yang berpengaruh dalam analisis antara lain matriks bahan, kondisi kevakuman dan konsentrasi unsur dalam bahan, pengaruh unsur yang mempunyai energi karakteristik berdekatan dengan energi karakteristik unsur yang dianalisis [2]. Tujuan dari tulisan ini adalah untuk mengetahui kevalidan metoda XRF untuk analisis bahan secara tunggal dan simultan. Alat spektrometer XRF EDAX DX 95 yang ada di PTBN BATAN, Serpong dapat digunakan untuk analisis unsur dalam bahan padat (masiv) dengan ukuran standar 3 cm. Bila bahan yang dianalisis mempunyai ukuran lebih besar dari 3 cm, maka pengukuran bahan dilakukan satu persatu (tunggal) sedangkan bila ukuran sampel kurang dari 3 cm maka analisis dapat dilakukan secara simultan lebih dari 1 sampel. Spektrometer XRF dilengkapi dengan sampel holder 10 lubang untuk pengukuran secara simultan [3]. Kelebihan pengukuran secara simultan adalah kondisi vakum pengukuran relatif stabil dan waktu pengukuran lebih singkat. Dengan adanya perbedaan ukuran sampel yang dianalisis maka diduga akan mempengaruhi hasil pada analisis kuantitatif. Dalam industri nuklir standar paduan Aluminum digunakan sebagai kendali kualitas bahan kelongsong reaktor riset. Salah satu parameter ditentukan pada kendali kualitas adalah komposisi unsur yang terkandung dalam paduan Aluminum. Unsur Mg, Mn dan Fe sangat menentukan kualitas paduan Aluminum dalam hal keuletan, dan ketahanan korosi, sehingga Oleh karena itu dipandang perlu untuk melakukan analisis unsur secara tunggal dan simultan. METODE Bahan yang digunakan untuk kalibrasi energi adalah paduan AlCu (Al2024), sedangkan untuk pengujian digunakan blanko standar Aluminum dan 10 buah standar paduan Aluminium (Al5010 AA, 511/01, 512/01, 515/01, 521/01, 522/01, 523/01, 525/01, 526/01 dan 543/01) dari Jerman [4]. Alat yang digunakan untuk analisis bahan tersebut adalah Spektrometer XRF (EDAX DX-95), Phillips yang dilengkapi sistem pengolahan data (DX-4). Sebelum analisis, dilakukan preparasi sampel. Permukaan bahan yang akan dianalisis harus rata, halus dan bersih. Bahan yang akan dianalisis dibersihkan permukaannya menggunakan aseton dan ditunggu sampai kering, kemudian sampel ditempatkan pada sample holder alat XRF. Peralatan dikondisikan dengan cara memvakum sample chamber dan melakukan kalibrasi energi. Alat spectrometer XRF siap digunakan bila kevakuman sample chamber mencapai 200 militorr. Kalibrasi energi menggunakan sampel uji Al2024 pada kondisi tegangan kerja 14 kv dan kuat arus 90 µa serta input count rate sebesar 10000 cps (count per second). Selanjutnya dilakukan kalibrasi pengukuran blanko standar Aluminum dan 10 buah bahan standar paduan Aluminum pada tegangan 14 kv dan kuat arus 90 µa. Pengukuran secara tunggal dilakukan 7 kali pengulangan, sedangkan pengukuran secara simultan dilakukan 5 kali pengulangan untuk membuat kurva kalibrasi unsur Mg, Mn, dan Fe. Setelah diperoleh kurva kalibrasi, dilakukan evaluasi data terhadap data hasil kalibrasi untuk menentukan batas daerah linearitas dengan persamaan dan koefisien regresi. Selanjutnya pengukuran dilakukan terhadap salah satu bahan standar yang memiliki konsentrasi di daerah linearitas untuk mengetahui presisi dan akurasi pengukuran. Kondisi pengukuran sama dengan kondisi kalibrasi energi yaitu pada tegangan 14 kv dan kuat arus 90 µa. Setiap pengukuran memerlukan waktu 300 detik. Keberterimaan pengukuran dengan cara tunggal dan simultan dihitung melalui uji beda yaitu uji-f dan uji-t. HASIL DAN PEMBAHASAN Analisis kuantitatif unsur Mg, Mn, dan Fe dilakukan melalui pembuatan kurva kalibrasi dengan mengukur blanko standar Al dan sepuluh buah standar Al Alloy. Pengulangan pengukuran sebanyak 5-7 kali. Hubungan antara intensitas dan konsentrasi standar diplotkan sehingga membentuk kurva kalibrasi masing-masing unsur yang dianalisis secara tunggal dan simultan, hal ini ditunjukkan pada Gambar 1. STTN-BATAN & Fak. Saintek UIN SUKA 274 Rosika K., dkk

Tunggal Simultan Gambar 1. Kurva kalibrasi Unsur Mg, Mn dan Fe dalam paduan Aluminum Secara Tunggal dan Simultan Hasil pembuatan kurva kalibrasi digunakan untuk konstanta regresi, dan limit deteksi (LD) dan limit menentukan nilai batas bawah dan batas atas, kuantisasi (LQ) yang dituangkan pada Tabel 1 daerah pengukuran linear, persamaan garis dan Rosika K., dkk 275 STTN-BATAN & Fak. Saintek UIN SUKA

Tabel 1. Data Kurva Kalibrasi SEMINAR NASIONAL VI Unsur Linieritas Pengukuran Tunggal Pengukuran Simultan LD LQ Persamaan R 2 Persamaan R 2 Mg 0,40-2,87 y = 12,17x + 11.04 0,990 y = 11,84x + 13,34 0,985 0.123 0.253 Mn 0,10-0,51 y = 84,18x + 1,672 0,970 y = 88,88x + 3,063 0,977 0.000 0.007 Fe 0,084-0,44 y = 95,8x + 16,58 0.983 y = 85,11x + 10.69 0,942 0.012 0.013 Pada Tabel 1 terlihat bahwa nilai R 2 dari kurva kalibrasi unsur Mg, Mn dan Fe berkisar antara 90% sampai dengan 99%. Pustaka ASTM [5] menyatakan bahwa nilai R 2 pada metoda spektrometri berkisar pada nilai 95%. Bila lebih kecil dari 90% maka ketepatan antara persamaan dan data ukur kurang baik. Limit deteksi unsur Mg lebih besar daripada unsur Mn dan Fe. Daerah linearitas unsur Mg lebih besar daripada unsur Mn dan Fe. Hal ini disebabkan karena oleh energi sinar- X unsur Mg (1,25 kev) lebih kecil daripada energi sinar-x unsur Mn (5,89 kev) dan energi sinar-x unsur Fe (6,4 kev) sehingga dalam analisis unsur Mg sangat dipengaruhi oleh kondisi kevakuman sample chamber. Presisi dan akurasi pengukuran diperoleh dengan cara mengukur salah satu bahan standar yang digunakan sebagai sampel dengan nilai konsentrasi pada daerah kerja dengan pengulangan 5 kali. Tabel 2. Data Unjuk Kerja Unsur Mg, Mn dan Fe dalam Paduan Aluminum Pengukuran Tunggal Pengukuran Simultan Unsur Mg Mn Fe Mg Mn Fe Konsentrasi Sertifikat (%) 0.51 0.51 0.28 0.51 0.51 0.28 Konsentrasi (%) 0.539 0.505 0.289 0.526 0.5 0.262 Akurasi (%) 94.55 95.31 92.08 96.96 98.11 93.47 Presisi / RSD (%) 3.44 1.35 1.81 4.53 0.93 1.08 RSD Horwitz (%) 2.19 2.22 2.41 2.22 1.21 2.45 Energi (kev) 1.25 5.89 6.4 1.25 5.89 6.4 Pada Tabel 2 tercantum bahwa nilai akurasi unsur Mg, Mn dan Fe yang diperoleh dengan cara pengukuran tunggal lebih rendah daripada dengan cara simultan. Hal ini disebabkan adanya perbedaan kondisi kevakuman sample chamber pada waktu pengukuran. Untuk pengukuran cara tunggal, kondisi sample chamber berada dalam kevakuman awal yang sama, karena pengukuran setiap standar dilakukan pemvakuman secara berulang. Sedangkan pada cara pengukuran simultan kondisi pengukuran pemvakuman berlanjut secara simultan sehingga kondisi vakum sample chamber relatif lebih stabil dibanding kondisi vakum pengukuran secara tunggal. Namun presisi kedua cara tersebut untuk unsur Mn dan Fe masih dalam batas yang diterima. Hal ini ditunjukkan oleh nilai RSD yang lebih kecil daripada RSD Horwitz. Sedangkan nilai presisi untuk unsur Mg lebih besar daripada RSD Horwitz, karena presisi pengukuran unsur Mg lebih dipengaruhi oleh kondisi kevakuman dibanding unsur Mn dan Fe. Oleh karena itu untuk pengukuran unsur Mg, perlu dinaikkan kevakumannya agar kondisi pengukuran lebih stabil. Nilai akurasi unsur Fe lebih kecil dibanding unsur Mn, karena dalam analisis sebagian sinar-x yang dipancarkan oleh unsur Fe diserap oleh unsur Mn sehingga intensitas unsur Fe yang terdeteksi dipengaruhi oleh unsur Mn. Energi sinar-x kedua unsur tersebut berdekatan sehingga saling mempengaruhi (Mn = 5,89 kev dan Fe = 6,4 kev). Untuk mengetahui keberterimaan kedua cara tersebut maka dilakukan uji banding yaitu uji-f maupun uji-t [7] seperti yang tercantum pada Tabel 3. Pada Tabel 3 terlihat bahwa hasil perhitungan uji F dan uji t lebih kecil daripada nilai batas keberterimaan pada derajat kepercayaan 95%. Hal ini menunjukkan bahwa pengukuran secara tunggal dan simultan untuk penentuan unsur Mg, Mn dan Fe dalam paduan Aluminum tidak menunjukkan perbedaan yang signifikan, sehingga kedua cara tersebut dapat digunakan untuk analisis unsur Mg, Mn dan Fe dalam paduan Aluminum. STTN-BATAN & Fak. Saintek UIN SUKA 276 Rosika K., dkk

Tabel 3. Uji Beda Konsentrasi Unsur Mg, Mn, dan Fe Unsur Uji-F Uji-t Perhitungan Batas Keberterimaan Perhitungan Batas Keberterimaan Mg 0.94 3.87 0.89 1.96 Mn 1.96 3.87 0.34 1.96 Fe 0.16 3.87 1.84 1.96 KESIMPULAN Berdasarkan hasil analisis secara tunggal dan simultan dapat dinyatakan bahwa metoda yang digunakan telah valid pada tingkat kepercayaan 95%. Metoda simultan untuk penentuan konsentrasi unsur Mg, Mn dan Fe mempunyai akurasi lebih baik dibandingkan dengan metoda tunggal, sedangkan metoda tunggal maupun simultan untuk penentuan konsentrasi unsur Mn dan Fe mempunyai presisi lebih baik dibanding unsur Mg, dan berdasarkan hasil uji beda ( uji F dan uji t) maka konsentrasi unsur Mg, Mn dan Fe dalam paduan Aluminum secara tunggal dan simultan tidak memberikan perbedaan hasil yang signifikan sehingga kedua cara terdapat digunakan untuk penentuan unsur Mg, Mn dan Fe dalam paduan Aluminum. 7. ANDERSON, ROBERT L., Practical Statistics of Analytical Chemist, Van Nostrand Reinhold Company, New York, 1987 UCAPAN TERIMA KASIH Ucapan terima kasih kami sampaikan kepada Bapak Drs. Yusuf Nampira selaku Kepala Bidang Pengembangan Radiometalurgi (BPR)-PTBN yang memberikan ilmu yang sangat bermanfaat khususnya tentang metoda Spektromeri XRF, sehingga akhirnya menjadi tulisan ini. DAFTAR PUSTAKA 1. JENKIN, RON, X-Ray Fluorescence Spectrometry, John Wiley & Sons., 1988. 2. JENKIN, RON; GOULD, R.W.; GEDKE, DALE, Quantitative X-Ray Spectrometry, Second Edition, 1995, Marcel Dekker, Inc. 3. ANONIM, Operation Manual XRF-EDAX, Phillips, 1995 4. Analysen Zertifikat, Spectrochemische Al- Eichproben, 1985 5. ASTM, Use of Statistics in The Evaluation of Spectrometric Data, Volume 03.05.2000 6. KANTASUBRATA, JULIA, Dr., Pelatihan Tips and Triks Validasi Metoda, RCChem Learning Centre, 2009 Rosika K., dkk 277 STTN-BATAN & Fak. Saintek UIN SUKA

STTN-BATAN & Fak. Saintek UIN SUKA 278 Rosika K., dkk