Sri Maryanto, Budi Arisanto Pusat Teknologi Limbah Radioaktif, BATAN

dokumen-dokumen yang mirip
PENGOPERASIAN CHILLER UNTUK MENUNJANG MANAGEMENT TATA UDARA INSTALASI PENGOLAHAN LIMBAH RADIOAKTIF. Budi Arisanto Pusat Teknologi Limbah Radioaktif

PENGOPERASIAN CHILLED WATER SYSTEM PADA INSTALASI PENGOLAHAN LIMBAH RADIOAKTIF

UNJUK KERJA POMPA SIRKULASI SEBAGAI PENUNJANG OPERASI CHILLED WATER SYSTEM TAHUN Maryudi, Budi Arisanto Pusat Teknologi Limbah Radioaktif

PENGOPERASIAN SISTEM SARANA PENUNJANG TAHUN Maryudi Pusat Teknologi Limbah Radioaktif

STUDI SPESIFIKASI TEKNIK WATER CHILLER VAC IEBE

PENGOPERASIAN SISTEM VAC & OFF GAS. Gatot Sumartono Pusat T eknologi Limbah Radioaktif, BAT AN

Gambar 2.21 Ducting AC Sumber : Anonymous 2 : 2013

PENGOPERASIAN COOLING WATER SYSTEM UNTUK PENURUNAN TEMPERATUR MEDIA PENDINGIN EVAPORATOR. Ahmad Nurjana Pusat Teknologi Limbah Radioaktif-BATAN

BAB I PENDAHULUAN 1.1 Definisi Pengkondisian Udara

TUGAS TEKNIK DAN MANAJEMEN PERAWATAN SISTEM PEMELIHARAAN AC CENTRAL

PENGOPERASIAN SISTEM SERVICE WATER DAN DOMESTIC WATER PAD A INSTALASI PENGOLAHAN LlMBAH RADIOAKTIF

PENGOPERASIAN SISTEM AIR ElEBAS MINERAL SEBAGAI PENUNJANG PENGOLAHAN LlMBAH RADIOAKTIF. Sri Maryanto Pusat Teknologi Limbah RAdioaktif, BATAN

BAB II LANDASAN TEORI

LAPORAN AKHIR PERAWATAN & PERBAIKAN CHILLER WATER COOLER DI MANADO QUALITY HOTEL. Oleh : RIVALDI KEINTJEM

ANALISA AUDIT KONSUMSI ENERGI SISTEM HVAC (HEATING, VENTILASI, AIR CONDITIONING) DI TERMINAL 1A, 1B, DAN 1C BANDARA SOEKARNO-HATTA

SISTEM PENGKONDISIAN UDARA (AC)

PENGOPERASIAN SISTEM VAC & OFF GAS (SISTEM TATA UDARA) Gatot Sumartono, Ade Suherman Pusat Teknologi Limbah Radioaktif

BAB II TEORI DASAR. 2.1 Pengertian Sistem Tata Udara

PENGOPERASIAN SERVICE & DOMESTIC WATER SYSTEM SEBAGAI PENUNJANG PENGOLAHAN LIMBAH RADIOAKTIF DAN PENAMBAHAN AIR PADA SISTEM PENYEDIA MEDIA DAN ENERGI

Cara Kerja AC dan Bagian-Bagiannya

TUGAS AKHIR ANALISA KINERJA CHILLER WATER COOLED PADA PROYEK SCIENTIA OFFICE PARK SERPONG

PERAWATAN INSTALASI PENGOLAHAN LIMBAH RADIOAKTIF. Purwantara Pusat Teknologi Limbah Radioaktif

SISTEM TATA UDARA (AC) PADA BANGUNAN GEDUNG

BAB II LANDASAN TEORI

BAB IV CARA KERJA SISTEM AIR CONDITIONER ( WCP )

PENGOPERASIAN DAN PENGEMBANGAN BENGKEL IPLR

BAB I PENDAHULUAN 1.1. Latar Belakang 1.2. Rumusan Masalah

BAB II DASAR TEORI Prinsip Kerja Mesin Refrigerasi Kompresi Uap

PENGARUH MEDIA PENDINGIN AIR PADA KONDENSOR TERHADAP KEMAMPUAN KERJA MESIN PENDINGIN

BAB II LANDASAN TEORI

MAKALAH PRAKTIK PENSINGIN DAN TATAUDARA

KAJI EKSPERIMENTAL KARAKTERISTIK PIPA KAPILER DAN KATUP EKSPANSI TERMOSTATIK PADA SISTEM PENDINGIN WATER-CHILLER

CHILLER. Gambar 1. Pipa Exchanger Chiller

OPTIMALISASI PENGOPERASIAN SISTEM PENYEDIA MEDIA & ENERGI. Maryudi Pusat Teknologi Limbah Radioaktif-BATAN

II. TINJAUAN PUSTAKA. apartemen, dan pusat belanja memerlukan listrik misalnya untuk keperluan lampu

BAB I PENDAHULUAN I.1. Latar Belakang

LAPORAN AKHIR FISIKA ENERGI II PEMANFAATAN ENERGI PANAS TERBUANG PADA MESIN AC NPM : NPM :

Commissioning & Maintenance of Air Conditioning System

PENGOPERASIAN BOILER SEBAGAI PENYEDIA ENERGI PENGUAPAN PADA PENGOLAHAN LIMBAH RADIOAKTIF CAIR DALAM EVAPORATOR TAHUN 2012

PERAWATAN WATER COOLED CHILLER DI HOTEL NOVOTEL MANADO

PERAWATAN DAN PERBAIKAN AIR CONDITIONER

UNJUK KERJA SISTEM TATA UDARA UNTUK MENUNJANG OPERASI PENGOLAHAN LIMBAH RADIOAKTIF

Disusun oleh : Nama : Linggar G. C. M. A. Semester Genap SMK NEGERI 1 CIMAHI

BAB II LANDASAN TEORI

OPTIMASI SISTEM PENGKONDISIAN UDARA PADA KERETA REL LISTRIK

BAB II DASAR TEORI. Laporan Tugas Akhir. Gambar 2.1 Schematic Dispenser Air Minum pada Umumnya

V12 V10 V11 BAB IV BAHASAN UTAMA. 4.1 Analisa Kerja Mesin Pendingin. Gambar 4.1 Skema Distribusi Aliran Analisa Penggunaan Chiller

BAB II DASAR TEORI BAB II DASAR TEORI

BAB II MESIN PENDINGIN. temperaturnya lebih tinggi. Didalan sistem pendinginan dalam menjaga temperatur

Jonner Sitompul Pusat Teknologi Limbah Radioaktif, BAT AN

Bagian V: PENGKONDISIAN UDARA

BAB IV PEMBAHASAN DAN ANALISA MESIN PENDINGIN

BAB II DASAR TEORI 2012

BAGIAN II : UTILITAS TERMAL REFRIGERASI, VENTILASI DAN AIR CONDITIONING (RVAC)

REKAYASA RANCANG BANGUN TRAINER SISTEM KELISTRIKAN AC MOBIL DAIHATSU ZEBRA

Desain Fasilitas Uji Kinerja Water-Cooled Chiller dan Air-Cooled Chiller Berdasarkan Standar AHRI

BAB II DASAR TEORI. 2.1 Pengertian Sistem Heat pump

BAB II TEORI DASAR. Laporan Tugas Akhir 4

Analisa Performansi Sistem Pendingin Ruangan dan Efisiensi Energi Listrik padasistem Water Chiller dengan Penerapan Metode Cooled Energy Storage

BAB II DASAR TEORI BAB II DASAR TEORI

TRAINING Operational, Maintenance & Trouble Air Cooled - Water Cooled Package

Program pemeliharaan. Laporan pemeliharaan

ANALISIS BEBAN PENDINGINAN DAN KALOR UNIT PENGKONDISIAN UDARA DAIHATSU XENIA

BAB II DASAR TEORI. 2.1 Cooling Tunnel

BAB III PENGETAHUAN DASAR TENTANG AC ( AIR CONDITIONER )

OPTIMALISASI DAN MODIFIKASI FASILITAS IPLR

SISTEM REFRIGERASI KOMPRESI UAP

PERAWATAN PERALATAN PROSES EVAPORASI. Bambang Sugito Pusat Teknologi Limbah Radioaktif, BATAN

Penggunaan Refrigeran R22 dan R134a pada Mesin Pendingin. Galuh Renggani Wilis, ST.,MT

OPTIMASI PENGGUNAAN AC SEBAGAI ALAT PENDINGIN RUANGAN

KAJIAN MODA OPERASI TWO OF THREE PADA ARUS BEBAN SISTEM PENDINGIN SEKUNDER RSG-GAS

BAB III LANDASAN TEORI

AIR CONDITIONING SYSTEM. Oleh : Agus Maulana Praktisi Bidang Mesin Pendingin Pengajar Mesin Pendingin Bandung, 28 July 2009

PENGARUH KECEPATAN UDARA PENDINGIN KONDENSOR TERHADAP KOEFISIEN PRESTASI AIR CONDITIONING

PERAWATAN PERALATAN LlSTRIK (PENGENDALI) PROSES SEMENT ASI

BAB I PENDAHULUAN. DKI Jakarta. Beberapa gedung bertingkat, pabrik, rumah sakit, perkantoran,

ANALISIS KERUSAKAN DAN PERBAIKAN SISTEM PENGERING UDARA AD 232 INST ALASI RADIOMET ALURGI

Pemakaian Thermal Storage pada Sistem Pengkondisi Udara

BAB II. Prinsip Kerja Mesin Pendingin

BAB II DASAR TEORI LAPORAN TUGAS AKHIR. 2.1 Blast Chiller

BAB II LANDASAN TEORI. Tata udara (Air Conditioning) adalah ilmu praktis dalam usaha

DASAR TEKNIK PENDINGIN

Sistem pendingin siklus kompresi uap merupakan daur yang terbanyak. daur ini terjadi proses kompresi (1 ke 2), 4) dan penguapan (4 ke 1), seperti pada

BAB I PENDAHULUAN. 1.1 Latar Belakang Penelitian. Air Conditioning (AC) adalah suatu mesin pendingin sebagai sistem pengkondisi

PENGOPERASIAN DAN PENGEMBANGAN BENGKEL IPLR. Harwata Pusat Teknologi Limbah Radioaktif

ANALISA KINERJA MESIN REFRIGERASI RUMAH TANGGA DENGAN VARIASI REFRIGERAN

LAPORAN TUGAS AKHIR BAB II DASAR TEORI

SAM PEL LlMBAH UNTUK ANALISIS DI LABORA TORIUM

Seminar Nasional Mesin dan Industri (SNMI4) 2008 ANALISIS PERBANDINGAN UNJUK KERJA REFRIGERATOR KAPASITAS 2 PK DENGAN REFRIGERAN R-12 DAN MC 12

PENDINGINAN KOMPRESI UAP

BAB II LANDASAN TEORI

BAB II DASAR TEORI. perpindahan kalor dari produk ke material tersebut.

PERFORMANSI MODULAR CHILLER KAPASITAS 120 TR

PELATIHAN PENGOPERASIAN DAN PERAWATAN MESIN PENDINGIN. Oleh : BALAI PENDIDIKAN DAN PELATIHAN PERIKANAN TEGAL

BAB II LANDASAN TEORI

BAB II TINJAUAN PUSTAKA

BAB II LANDASAN TEORI

BAB II STUDI PUSTAKA

PENGARUH BEBAN PENDINGIN TERHADAP TEMPERATUR SISTEM PENDINGIN SIKLUS KOMPRESI UAP DENGAN PENAMBAHAN KONDENSOR DUMMY

BAB II LANDASAN TEORI. Suatu mesin refrigerasi akan mempunyai tiga sistem terpisah, yaitu:

Transkripsi:

Hasil Penelilian dan Kegiatan PTLR Tahlln 2006 ISSN 0852-2979 PENGOPERASIAN CHILLER UNTUK MENUNJANG PENGELOLAAN TAT A UDARA IPLR TAHUN 2006 Sri Maryanto, Budi Arisanto Pusat Teknologi Limbah Radioaktif, BATAN ABSTRAK PENGOPERASIAN CHILLER UNTUK MENUNJANG PENGELOLAAN TATA UDARA IPLR TAHUN 2006. Telah dilakukan pengoperasian Chiller untuk menunjang pengelolaan tata udara di Instalasi Pengolahan Limbah Radioaktif (IPLR) selama 8 jam dalam 5 hari kerja. Chiller dioperasikan untuk mensuplai air dingin ke Air handling unit (AHU) untuk mendinginkan udara pada Instalasi Pengolahan Limbah Radioaktif. Pada tahun 2006 juga telah berhasil memperbaiki chiller E 62304 sehingga dari 4 unit Chiller yang ada, 3 unit Chiller dapat dioperasikan secara bergantian. Dengan beroperasinya 3 unit chiller maka beban pendinginan yang mencapai 416,4 Ton Referigator (TR) dapat terpenuhi. ABSTRACT OPERATION OF CHILLER TO SUPPORT AIR HANDLING MANAGEMENT IN THE INSTALLATION OF RADIOACTIVE WASTE MANAGEMENT IN THE YEAR 2006. Have been done The operation of Chiller to support air handling management in the Installation of Radioactive Waste management during 8 Hour in 5 workday. Chiller been operated for supplied cold water to air handling unit (AHU) for cooling the air in the installation of radioactive waste management. In the year 2006 also have been repaired chiller E 62304 so from 4 unit Chiller existing, 3 unit of Chiller can be operated with rotation operation. The operation of 3 unit of chiller can handle refrigeration burden to 426,4 Ton Refrigerator (TR). PENDAHULUAN Sistem tata udara (AHU) merupakan sistem yang sangat penting dalam menunjang kegiatan operasional pad a instalasi nuklir. Sistem tat a udara yang baik akan dapat menjaga kelembaban, tekanan udara serta suhu ruangan sesuai dengan yang di inginkan, sehingga kenyamanan personal dan keamanan peralatanpun dapat terjaga dengan baik. Oi Pusat Teknologi Limbah Radioaktif (PTLR), selain digunakan untuk tata udara, Chilled Water System juga digunakan untuk pendingin (penukar panas) pad a Evaporator dan Insenerator. Chilled Water system mensuplay air dengan suhu 6 C sid 7 C untuk diumpankan ke beban-beban pending in pad a cooling coil AHU dan Heat Exchanger yang merupakan alat penukar panas. Satuan pendingin adalah Ton Refrigator (TR), 1 TR setara dengan 12000 Btu/.lam. Chiller merupakan salah satu alat didalam Chilled Water System. Chilled Water system merupakan salah satu komponen yang penting dalam Sistem Tata Udara. Komponen Chilled Water System adalah: 486

Hasi/ Penelitian dan Kegiatan PTLR Tahun 2006 /SSN 0852-2979 1. Chiller, berfungsi untuk menurunkan suhu air. Pada desain operasi (operasi normal), dioperasikan 3 unit Chiller dan 1 unit Chiller yang lain pada posisi cadangan (stand by). Sistem Chilled Water PTLR terdiri dari 4 unit Chiller jenis Air Cooled yaitu E 62301, E 62302, E 62303 dan E 62304 namun pad a tahun 2004 ini hanya beroperasi 2 Chiller, yaitu E 62302 dan E 62303, dengan spesifikasi teknis: Merek Yo~ Kapasitas @ 170 TR x 4 = 680 TR Daya Compressor @ 200 KW x 4 = 800 KW Daya Fan Condensor @ 22 KW x 4 = 88 KW Setiap unit Chiller York terdiri dari dua sistem rangkaian refrigator yang masingmasing berkapasitas 70 TR untuk sistem I dan 100 TR untuk sistem II. Setiap Chiller menggunakan sistem control berbasis mikro Komputer Kontrol untuk mengendalikan operasional Chiller. Didalam Chiller terdapat refrigerant (bahan pending in) yang bersirkulasi dan mengalami beberapa perubahan bentuk sesuai siklus Carnot. Refrigant yang digunakan adalah Freon (R 22) yang akan mengalami kompresi, condensasi, exspansi dan evaporasi. Dalam siklus Carnot ini akan terjadi penyerapan dan pelepasan kalor. Komponen utama chiller yaitu: a. Compressor, berfungsi untuk menaikan titik embun gas freon (ondensasi). b. Condensor berfungsi sebagai tempat pengembunan freon (berkondensasi) c. Katup ekspansi berfungsi untuk menurunkan titik didih cairan air freon. d. Evaporator berfungsi sebagai tempat penguapan cairan freon (Evaporasi) e. Filter Drayer yang berfungsi sebagai penyaring kotoran f. Bahan Pendingin (refrigrant) biasanya R22 atau R 12. 2. Pompa Chiller Pompa Chiller digunakan untuk mendistribusikan air Chiller ke beban-beban pendingin. dengan spesifikasi teknis: Jenis Pompa Sentrifugal Merek Thorisima Kapasitas Daya @ 250 GPM x 4 = 1000 GPM @ 20 HP x 4 = 80 HP 487

Hasil Penelitian dan Kegialan PTLR Tahun 2006 ISSN 0852-2979 Pompa dalam sistem Chilled Water yaitu P 62301, P 62302, P 62303 dan P 62304, pad a tahun 2006 ini, pompa yang dapat beroperasi adalah P 62302, P 62303 dan P 62304, sedangkan pompa P 62301 rusak pad a terminal motor pompa dan panel kontrol. Pad a operasi normal dibutuhkan dan 1 unit pompa sebagai cadangan (stand by). 3 unit pompa operasi 3. Beban Pendingin (Cooling Load), Beban-beban pending inan yang ada di PTLR dapat mencapai 416,4 TR, yaitu; a. Beban Tata Udara (AHU) Total beban 358,2 - Cooling Coil E 51010 291 TR - Cooling Coil E 51013 6,6 TR - Cooling Coil E 51014 4,8 TR - Cooling Coil E 51051 46,8 TR - Cooling Coil E 52010 1,8 TR - Cooling Coil E 52012 7,2 TR b. Beban Evaporasi Condensor E 62510 27 TR c. Beban Cooling Tower Heat Exchanger E 62102 30 TR d. Beban Insenerasi Heat Exchanger 4,6 TR 4. Sistem instalasi pemipaan dan katup-katup sebagai pendukung. TAT A KERJA Bahan dan Alat Untuk mendukung pengoperasian Chiller, maka diperlukan bahan-bahan yang dipakai untuk perawatan, yaitu: a. Oli Chiller York b. Refrigerant (R22) c. Tang Ampere d. Volt Meter e. Obeng dan Kunci-kunci mekanik f Isolator 488

Hasi/ Penelitian dan Kegiatan PTLR Tahun 2006 ISSN 0852-2979 Pengoperasian Chilled Water System Pada bulan Januari sampai dengan September Sistem Chilled Water beroperasi selama 24 jam dari hari Senin sampai Jum'at, atau 120 Jam setiap minggu, sedangkan pada bulan Oktober sampai dengan Desember Sistem Chilled Water beroperasi 8 jam sehari pad a hari kerja atau 40 jam setiap minggu. Cara pengoperasian sistem Chilled Water adalah: a. Masukkan fuse sentral (24 V) pada lernari panel "Dist-Board (1-92-01) di ruang 50.01.13. b. Masukkan power motor-pompa XM 62301, XM 62303, M 62303 dan XM 62304 pada lemari panel MCC-MESS (1-1'1-01) di ruang panel 51.01.05. c. Masukkan power Chiller, E 62302 dan E (32303 pada lemari panel LVMD 81 di ruang panel 51.01.05. d. Tekan tombol untuk masing-masing pompa Chiller e. P 62302, P 62303 dan P 62304. f. Hidupkan untuk Chiller E 62302 dengan menekan tombol hijau (ON) pada panel Chiller. g. Posisikan saklar leading-lagging SYS 1 pad a posisi leaging untuk mendapatkan operasi yang maksimal. h. Kemudian posisikan saklar sistem 1 dan sistem 2 pad a posisi ON. HASIL DAN PEMBAHASAN Tahun 2006 maupun telah dilakukan upaya-upaya baik dalam mengoperasikan sistem Chilled Water maupun kegiatan-kegiatan untuk menunjang pengoperasian, yaitu: 1. Pengoperasian sistem Chilled Water selama 8 jam dari hari Senin sampai Jum'at dari bulan Januari sampai dengan September, namun karena berbagai pertimbangan maka pad a bulan Oktober sampai dengan bulan Desember Sistem Chilled Water dioperasikan selama 8 jam sehari selama hari kerja. 2. Motor Pompa Chiller - Perawatan P 62302, P 62303 dan P 62304 dengan Aligment 3. Perbaikan dan perawatan Chiller a. Over hole Chiller E 62304 489

Hasi/ Penelitian dan Kegiatan PTLR Tahun 2006 ISSN 0852-2979 b. Chiller E 62302 dan E 6203 Pembersihan kisi-kisi pad a kondensor Pengecatan pad a rangka KESIMPULAN DAN SARAN Kesimpulan 1. Sampai akhir tahun 2006, 3 unit Chiller dapat difungsikan, yaitu Chiller E 62302, Chiller E 62303 dan Chiller E 62304, sedangkan Chiller E 62301 rusak total. 2. Motor Pompa Chiller hanya dapat dioperasikan 3 unit motor pompa, yaitu P 62302, P 62303 dan P 62304, sedangkan pompa P 62301 rusak pada panel kontrol dan terminal motor. 3. Digunakan sistem operasi 2 unit Chiller operasi dan 1 unit Chiller lainnya stand by untuk safety pengoperasian. Saran Karena pentingnya fungsi Chiller, sebaiknya Chiller E 62301 segera diperbaiki atau dig anti dengan Chiller banjo Hal ini karena saat ini Chiller dapat dioperasikan 3 unit Chiller, sedangkan untuk memenuhi kebutuhan pending inan di IPLR diperlukan 3 Chiller beroperasi dan 1 Chiller Stand by. 3 unit Chiller yang ada harus dirawat dengan sebaik-baiknya. DAFTAR PUSTAKA 1. PU RW ANT ARA, "Pengaperasian Chiller untuk menunjang managemen tata udara IPLR", Hasil Penelitian dan Kegiatan PTLR 2001, PTLR-SATAN, Serpong, 2001. 2. YORK INTERNATIONAL COOPERATION, "Air Cooled Packaged Liquid Chiller", USA, 1986. 3. PI. JAYA TEKNIK, YORK AIR CONDITIONING SINGAPORE,''Diktat seminar York Air Conditioning service & Maintenance", Jakarta, 9 Juli 1992. 4. SATAN/ UPT-PPIN, DOKUMEN 42, E42-623, "control & Instrument note far Chilled Water System", Jakarta, Desember 1985. 5. SATAN/ UPT-PPIN, DOKUMEN 75, E75-623, "Data sheet for Chilled Water Control System", Jakarta, Desember 1985. 490