STUDI KOMPARASI PENGUJIAN KEPADATAN MINERAL TULANG PHANTOM

dokumen-dokumen yang mirip
Ketetapan resmi terkini ISCD tahun 2013 (pasien anak-anak) Dibawah ini adalah ketetapan resmi ISCD yang telah diperbaruhi tahun 2013

PERBANDINGAN DOSIS RADIASI DI UDARA TERHADAP DOSIS RADIASI DI PERMUKAAN PHANTOM PADA PESAWAT CT-SCAN

PENGUKURAN DOSIS RADIASI PADA PASIEN PEMERIKSAAN PANORAMIK. Abdul Rahayuddin H INTISARI

ANALISIS SEBARAN RADIASI HAMBUR CT SCAN 128 SLICE TERHADAP PEMERIKSAAN CT BRAIN

STUDI AWAL UJI PERANGKAT KAMERA GAMMA DUAL HEAD MODEL PENCITRAAN PLANAR (STATIK) MENGGUNAKAN SUMBER RADIASI MEDIUM ENERGY RADIUM-226 (Ra 226 )

STUDI AWAL UJI PERANGKAT KAMERA GAMMA DUAL HEAD MODEL PENCITRAAN PLANAR STATIK MENGGUNAKAN SUMBER RADIASI HIGH ENERGY IODIUM-131 (I 131 )

PENENTUAN KEMBALI KOMPOSISI KOMPOSIT KARET ALAM TIMBAL OKSIDA SEBAGAI PERISAI RADIASI SINAR-X SESUAI KETENTUAN BAPETEN

PRIMA Volume 8, Nomor 1, Juni 2011 ISSN : DESAIN PINTU RUANG PESAWAT SINAR-X DARI BAHAN KOMPOSIT KARET ALAM TIMBAL OKSIDA

Pengaruh Ketidakhomogenan Medium pada Radioterapi

PENGARUH DIAMETER PHANTOM DAN TEBAL SLICE TERHADAP NILAI CTDI PADA PEMERIKSAAN MENGGUNAKAN CT-SCAN

Analisa Kualitas Sinar-X Pada Variasi Ketebalan Filter Aluminium Terhadap Dosis Efektif

PENGARUH TEGANGAN TABUNG (KV) TERHADAP KUALITAS CITRA RADIOGRAFI PESAWAT SINAR-X DIGITAL RADIOGRAPHY (DR) PADA PHANTOM ABDOMEN

UJI KESESUAIAN PESAWAT CT-SCAN MEREK PHILIPS BRILIANCE 6 DENGAN PERATURAN KEPALA BAPETEN NOMOR 9 TAHUN 2011

PENENTUAN KARAKTERISASI CERROBEND SEBAGAI WEDGE FILTER PADA PESAWAT TELETERAPI 60 Co

PENENTUAN NILAI NOISE BERDASARKAN SLICE THICKNESS PADA CITRA CT SCAN SKRIPSI HEDIANA SIHOMBING NIM :

BAB I PENDAHULUAN. Meningkatnya kesadaran masyarakatakan hidup sehat. menyebabkan jumlah usia lanjut menjadi semakin banyak, tak terkecuali di

Jurnal Fisika Unand Vol. 3, No. 3, Juli 2014 ISSN

UJI KESESUAIAN CT NUMBER PADA PESAWAT CT SCAN MULTI SLICE DI UNIT RADIOLOGI RUMAH SAKIT ISLAM YOGYAKARTA PDHI

NILAI DIAGNOSTIK OSTEOPOROSIS SELF-ASSESMENT TOOL FOR ASIANS

KUALITAS GAMBAR RADIOGRAFI KONVENSIONAL

Verifikasi TPS untuk Dosis Organ Kritis pada Perlakuan Radioterapi Area Pelvis dengan Sinar X 10 Megavolt

PERBANDINGAN KARAKTERISTIK KELUARAN ANTARA PESAWAT SINAR-X TOSHIBA MODEL DRX-1824B DAN TOSHIBA MODEL DRX-1603B. Skripsi

UJI KORELASI NILAI TEKSTUR CITRA RADIOGRAF PERIAPIKAL DIGITAL DENGAN NILAI KEPADATAN MASSA TULANG. Abstract. Intisari

PENGARUH VARIASI AIR GAP TERHADAP DOSIS SERAP PENYINARAN BERKAS ELEKTRON PADA PESAWAT LINAC SIEMENS / PRIMUS M CLASS 5633

UJI IMAGE UNIFORMITY PERANGKAT COMPUTED RADIOGRAPHY DENGAN METODE PENGOLAHAN CITRA DIGITAL

Jurnal Fisika Unand Vol. 3, No. 2, April 2014 ISSN

ABSTRAK. Jimmy Wahyu Pembimbing: Aming Tohardi, dr. MS. Wawan Kustiawan, dr., SpRad., M. Kes., DFM.

Analisis Pengaruh Faktor Eksposi terhadap Nilai Computed Tomography Dose Index (CTDI) pada Pesawat Computed Tomography (CT) Scan

PERTEMUAN KE 1 (50 MENIT)

BAB I PENDAHULUAN. Osteoporosis atau keropos tulang adalah penyakit silent epidemic, yang

Youngster Physics Journal ISSN : Vol. 2, No. 1, April 2013, Hal 27-34

PENENTUAN CT DOSE INDEX (CTDI) UNTUK VARIASI SLICE THICKNESS DENGAN PROGRAM DOSXYZNRC

PENENTUAN NILAI TEBAL PARUH (HVL) PADA CITRA DIGITAL COMPUTED RADIOGRAPHY

ANALISIS PERHITUNGAN KETEBALAN PERISAI RADIASI PERANGKAT RIA IP10.

ANALISIS KOLIMASI BERKAS SINAR-X PADA PESAWAT FLUOROSCOPY (MOBILE C-ARM) DIRUMAH SAKIT UNIVERSITAS HASANUDDIN

Pendeteksian Tepi Citra CT Scan dengan Menggunakan Laplacian of Gaussian (LOG) Nurhasanah *)

PENGARUH JARAK TABUNG SINAR-X DENGAN FILM TERHADAP KESESUAIAN BERKAS RADIASI PADA PESAWAT X-RAY SIMULATOR DI INSTALASI RADIOTERAPI RSUD DR

ANALISA PENGARUH GRID RASIO DAN FAKTOR EKSPOSI TERHADAP GAMBARAN RADIOGRAFI PHANTOM THORAX

METODA PENENTUAN DAYA SERAP PERISAI RADIASI UNTUK GONAD DARI KOMPOSIT LATEKS CAIR TIMBAL OKSIDA

HUBUNGAN PERSENTASE LEMAK TUBUH DENGAN TOTAL BODY WATER MAHASISWA FAKULTAS KEDOKTERAN UNIVERSITAS DIPONEGORO SEMARANG LAPORAN HASIL KARYA TULIS ILMIAH

KARAKTERISASI KACA TIMBAL UNTUK PELINDUNG PENANGKAP CITRA SINAR-X

BAB I PENDAHULUAN I.1. Latar Belakang

Epidemiologi Penilaian Status Gizi: Antropometri

BAB I PENDAHULUAN. A. Latar Belakang Penelitian. massanya, maka radiasi dapat dibagi menjadi radiasi elektromagnetik dan radiasi

PENENTUAN TEBAL PERISAI RADIASI PERANGKAT RADIOTERAPI EKSTERNAL Co-60 UNTUK POSISI PENYINARAN

BAB I PENDAHULUAN 1.1. Latar Belakang

Analisis Proses Beam Hardening Pada Citra Tomografi Komputer

BAB 1 PENDAHULUAN. dari masa remaja memberikan dampak pada masalah kesehatan. Salah satu

ANALISIS PENGGUNAAN POLYDIMETHYL SILOXANE SEBAGAI BOLUS DALAM RADIOTERAPI MENGGUNAKAN ELEKTRON 8 MeV PADA LINAC

BAB 1 PENDAHULUAN. kesehatan yang belum dapat diselesaikan oleh negara-negara maju. dan berkembang di dunia. Studi pada tahun 2013 dari Institute for

BAB I PENDAHULUAN. 1.1 Latar Belakang Indeks Massa Tubuh (IMT) adalah metode sederhana yang

STUDI PENGARUH UKURAN PIXEL IMAGING PLATE TERHADAP KUALITAS CITRA RADIOGRAF

SELF-ABSORPTION COMPUTING OF PHOTON GAMMA IN VOLUMETRIC SAMPEL. Masril. Dosen Jurusan Fisika FMIPA UNP

BAB II TINJAUAN PUSTAKA

BAB I PENDAHULUAN. jaringan yang paling kering, memiliki kandungan H 2 O hanya 10%. Karena itu

Analisis Perubahan Kurva Percentage Depth Dose (PDD) dan Dose Profile untuk Radiasi Foton 6MV pada Fantom Thoraks

BAB I PENDAHULUAN. mineral tulang disertai dengan perubahan mikroarsitektural tulang,

EVALUASI TEBAL DINDING RUANGAN PESAWAT LINEAR ACCELERATOR (LINAC) SINAR-X DI INSTALASI RADIOTERAPI RUMAH SAKIT UNIVERSITAS HASANUDDIN

PENGARUH FAKTOR EKSPOSE TERHADAP KONTRAS RESOLUSI CT SCAN SKRIPSI HOTROMASARI DABUKKE NIM :

PERANCANGAN RUANGAN RADIOGRAFI MEDIK DI SEKOLAH TINGGI TEKNIK NUKLIR

PENDAHULUAN. A. Latar Belakang Masalah. Pemeriksaan Computed Tomography (CT scan) merupakan salah salah

Samsun, Legia Prananto, Asep Awan Gunawan, Novita Wulandari

BAB I PENDAHULUAN 1.1. Latar Belakang Masalah

RENCANA PROGRAM KEGIATAN. Prasyarat : 1. Deteksi Dan Pengukuran Radiasi 2. Fisika Atom Dan Inti

APLIKASI TEKNIK PENGOLAHAN CITRA DIGITAL PADA DOMAIN SPASIAL UNTUK PENINGKATAN KUALITAS CITRA SINAR-X

PERHITUNGAN NILAI DOSIS DAN KONTRAS CITRA COMPUTED RADIOGRAPHY (CR) DENGAN VARIASI KETEBALAN DAN KOMBINASI JENIS FILTER

IDENTIFIKASI PENGARUH VARIASI UKURAN BUTIRAN TERHADAP UNSUR DAN STRUKTUR KRISTAL CANGKANG TELUR AYAM RAS

BAB I PENDAHULUAN 1.1 Latar Belakang

PEMBUATAN MODEL UJI NILAI TEBAL PARUH (HVL) PESAWAT KONVENSIONAL SINAR-X MENGGUNAKAN PENGOLAHAN CITRA DIGITAL

PENENTUAN NILAI KOEFISIEN SERAPAN BAHAN DAN DOSIS RADIASI PADA VARIASI KOMBINASI KAYU DAN ALUMINIUM

Perhitungan Energi Disosiasi Gugus Fungsi OH - dan PO 4

PERSENTASE DOSIS KEDALAMAN (PDD) PADA PESAWAT TELETERAPI CO-60. Fisikawan medik Habib Syeh Az /

BAB I PENDAHULUAN. 1.1 Latar Belakang

Evaluasi Ketebalan Irisan (Slice Thickness) pada Pesawat CT- Scan Single Slice

PEREKAYASAAN PERISAI RADIASI TIROID MENGGUNAKAN KOMPOSIT LATEKS CAIR TIMBAL OKSIDA DENGAN TEKNOLOGI ULTRA SONIK DAN SUHU SUPER KRITIS

KOREKSI KURVA ISODOSIS 2D UNTUK JARINGAN NONHOMOGEN MENGGUNAKAN METODE TAR (TISSUE AIR RATIO)

BAB I PENDAHULUAN. Osteoporosis merupakan salah satu penyakit degeneratif yang. menjadi permasalah global di bidang kesehatan termasuk di Indonesia.

PERANCANGAN RUANGAN RADIOTERAPI EKSTERNAL MENGGUNAKAN SUMBER Co-60

BAB I PENDAHULUAN. Osteoporosis adalah penyakit pengeroposan tulang yang banyak diderita

PENGARUH KONSENTRASI Ca 2+ DAN (PO4) 3- PADA PEMBENTUKAN HIDROKSIAPATIT DI DALAM MATRIKS SELULOSA BAKTERIAL

KARAKTERISASI ATENUASI ULTRASONIK TERHADAP VARIASI TEBAL BAHAN (CAIRAN) MENGGUNAKAN TRANSDUSER ULTRASONIK JENIS IMMERSION TRANSDUCER ABSTRACT

BAB 1 PENDAHULUAN. Universitas Sumatera Utara

REKAYASA PERANGKAT LUNAK UNTUK PERBAIKAN KUALITAS CITRA. RADIOGRAFI SINAR-X MENGGUNAKAN MATLAB 7.3.0(R2006b) Skripsi

PERBANDINGAN KADAR LEMAK TUBUH BERDASARKAN PENGUKURAN INDEKS MASSA TUBUH (IMT) DAN SKINFOLD THICKNESS (SFT) PADA ORANG DEWASA

ANALISIS DOSIS SERAP RADIASI PADA PERBEDAAN DIMENSI DAN BENTUK LAPANGAN PENYINARAN BERKAS RADIASI FOTON 6 MV

ANALISIS PENGARUH KETIDAKTAJAMAN GEOMETRI, PERGERAKAN DAN SCREEN TERHADAP PENGABURAN DAERAH TEPIAN FILM RADIOGRAFI

JURNAL KEDOKTERAN DIPONEGORO

ANALISIS IMAGE NOISE DAN NILAI DOSIS RADIASI PENGGUNAAN APLIKASI CARE DOSE 4D DAN NON CARE DOSE 4D PADA PESAWAT MSCT SIEMENS

BAB V Ketentuan Proteksi Radiasi

PENDAHULUAN. A. Latar Belakang. tindakan tertentu, maupun terapetik. Di antara prosedur-prosedur tersebut, ada

EFEKTIFITAS VARIASI NILAI WINDOW LEVEL TERHADAP KUALITAS HASIL CT SCAN THORAX LUNG WINDOW. Rahmadani

ESTIMASI NILAI CTDI DAN DOSIS EFEKTIF PASIEN BAGIAN HEAD, THORAX DAN ABDOMEN HASIL PEMERIKSAAN CT-SCAN MEREK PHILIPS BRILIANCE 6

ADLN - PERPUSTAKAAN UNIVERSITAS AIRLANGGA SKRIPSI

ANALISIS PENGARUH HARGA, KUALITAS PRODUK DAN KUALITAS PELAYANAN TERHADAP KEPUASAN PELANGGAN (Surve pada Cafe Kedai Mat Moen di Boyolali)

BAB I PENDAHULUAN. Osteoporosis merupakan penyakit tulang yang pada tahap awal belum

BAB I PENDAHULUAN. karies gigi (Wahyukundari, et al., 2009). Berdasarkan hasil riset dasar yang

Analisis Dosis Serap CT Scan Thorax Dengan Computed Tomography Dose Index Dan Thermoluminescence Dosimeter

Analisis Pengaruh Sudut Penyinaran terhadap Dosis Permukaan Fantom Berkas Radiasi Gamma Co-60 pada Pesawat Radioterapi

PENGUKURAN DOSIS PAPARAN RADIASI DI AREA RUANG CT SCAN DAN FLUOROSKOPI RSUD DR. SAIFUL ANWAR MALANG. Novita Rosyida

PENGARUH SEMANGAT KERJA PEMILIK DAN PEKERJA TERHADAP KEWIRAUSAHAAN MORO ARTOS DI SALATIGA SKRIPSI

Transkripsi:

STUDI KOMPARASI PENGUJIAN KEPADATAN MINERAL TULANG PHANTOM KALSIUM HIDROKSIAPATIT ANTARA QUANTITATIVE COMPUTED TOMOGRAPHY DAN DUAL ENERGY X-RAY ABSORPTIOMETRY Skripsi Untuk memenuhi sebagian persyaratan mencapai derajat Sarjana S-1 Diajukan oleh : AGUS SHOLEH J2D207001 JURUSAN FISIKA FAKULTAS MATEMATIKA DAN ILMU PENGETAHUAN ALAM UNIVERSITAS DIPONEGORO SEMARANG 2010 1

ABSTRACT Has been realized, making calcium hydroxyapatite phantom (phantom CaHA) in agar gel matrix with CaHA density (ρ) 80 mg/cm 3, 100 mg/cm 3, 120 mg/cm 3, 140 mg/cm 3, 160 mg/cm 3, 180 mg/cm 3, and 200 mg/cm 3 ). Phantom CaHA density tested with QCT and Dexa.. The both test results of bone mineral density compared to each other. In the QCT measurement data obtained by volumetric density of bone mineral, ρ(qct), in units of mass per cm 3 and the linear attenuation coefficient of each phantom CaHA. Dexa measurement data obtained by area density of bone mineral, M(Dexa), in units of mass per cm 2 and the composition of fatty tissue in units of percent (%). Area density (M) is the product of volumetric density (ρ) with phantom thickness. Data ρ(qct) multiplied by the thickness of phantom to obtain the area density M(QCT). The result of this calculation is compared with M(Dexa). While data M(Dexa) divided by phantom thickness to obtain the volumetric density ρ(dexa). The result of this calculation is compared with ρ(qct). Results showed a comparative value test density area between QCT and Dexa is M (QCT) = 45.95 +1.07 M (Dexa) and comparisons of voumetric density values test between Dexa and QCT is ρ (Dexa) = -12.17 +0, 92ρ (QCT) with r = 0.996 and R = 0.992. Keywords: calcium hydroxyapatite phantom (phantom CaHA), QCT, Dexa, the linear attenuation coefficient INTISARI Telah terealisasi pembuatan phantom kalsium hidroksiapatit (phantom CaHA) dalam matrik jel agar-agar dengan kepadatan CaHA (ρ) 80 mg/cm 3, 100 mg/cm 3, 120 mg/cm 3, 140 mg/cm 3, 160 mg/cm 3, 180 mg/cm 3, dan 200 mg/cm 3 ). Phantom CaHA diuji kepadatannya dengan QCT dan DEXA. Hasil pengujian kepadatan mineral tulang keduanya dibandingkan. Pada pengukuran dengan QCT diperoleh data kepadatan volumetrik mineral tulang, ρ (QCT), dalam satuan massa per cm 3 dan koefisien atenuasi linear masing-masing phantom CaHA. Dari pengukuran dengan DEXA diperoleh data kepadatan luasan mineral tulang, M (DEXA), dalam satuan massa per cm 2 dan komposisi jaringan lemak dalam satuan persen (%). Kepadatan luasan (M) adalah hasil kali kepadatan volumetrik (ρ) dengan tebal phantom. Data ρ (QCT) dikalikan tebal phantom sehingga didapatkan kepadatan luasan M (QCT). Hasil penghitungan ini dibandingkan dengan pengukuran M (DEXA). Sedangkan data M (DEXA) dibagi dengan tebal phantom sehingga didapatkan kepadatan volumetrik ρ (DEXA). Hasil penghitungan ini dibandingkan dengan pengukuran ρ (QCT). Hasil penelitian menunjukkan komparasi nilai pengujian kepadatan luasan antara QCT dan DEXA adalah : M (QCT) = 45,95+1,07M (DEXA) dan komparasi nilai pengujian kepadatan volumetrik antara DEXA dan QCT adalah : ρ (DEXA) = -12,17+0,92ρ (QCT) dengan r=0,996 dan R=0,992. Kata kunci : phantom kalsium hidroksiapatit (phantom CaHA), QCT, DEXA, koefisien atenuasi linear 2

BAB I PENDAHULUAN 1.1 Latar Belakang Perkembangan dan kemajuan ilmu pengetahuan serta teknologi di bidang kesehatan khususnya di bidang radiologi saat ini sangat pesat. Peralatan sinar-x selain dapat menghasilkan citra organ juga dapat menampilkan data kuantitatif dalam fungsi pengukuran bone mineral density (bmd), atau juga disebut kepadatan mineral tulang (kmt). Fungsi pengukuran kepadatan mineral tulang adalah untuk menetapkan nilai bmd sebelum tindakan terapi, mengidentifikasi pasien osteoporosis resiko tinggi untuk tindakan pencegahan atau terapi, memonitor nilai bmd untuk melihat perkembangan tindakan terapi, dan evaluasi pada kasus osteoporosis atau osteopenia. Fungsi pengukuran dalam pemanfaatan teknologi ini dapat juga dibarengi dengan fungsi pencitraan organ yang diperiksa. Walaupun pada peralatan tertentu citra organ tidak ditonjolkan tetapi hanya data kuantitatif yang ditonjolkan. CT Scanner mempunyai fungsi diagnosa dalam bentuk citra organ tetapi juga dapat berfungsi sebagai pengukur kepadatan mineral tulang pada organ tertentu dengan hasil pengukuran dalam satuan berat per satuan volume (mg/cm 3 ). Sementara itu, DEXA (Dual Energy X-ray Absorptiometry) berfungsi sebagai pengukur kepadatan mineral tulang pada organ tertentu dengan hasil pengukuran dalam satuan berat per satuan luas (mg/cm 2 ) (Grampp, 2008) tanpa menonjolkan citra organ sebagai hasil diagnosa. Energi sinar-x yang dihasilkan oleh CT Scanner bukan foton monoenergetik tetapi polienergetik (Avinash, 1999), sedangkan energi sinar-x yang dihasilkan oleh DEXA mempunyai dua puncak dengan menggunakan filter Cerium. Energi puncak tersebut pada 40 kev dan pada 70 kev (diunduh dari http://www.rah.sa.gov. au/nucmed/ BMD/ bmd_ equipment.htm, pada tanggal 19-2-2010). Quantitative CT dan DEXA sebagai sarana untuk mendiagnosa kelainan tulang, yaitu dengan mengukur kepadatan mineral tulang, mempunyai metode 3

yang berbeda. CT Scanner dengan energi polienergetik mampu menyajikan hasil pengukuran kepadatan volumetrik jaringan tulang dengan membedakan hasil kepadatan mineral tulang kortikal (mode kortikal) dan trabekular (mode trabekular), sedangkan DEXA menggunakan dua puncak energi mampu mengeliminasi jaringan lunak di sekitar jaringan tulang sehingga hasil pengukuran kepadatan mineral terpisah dari jaringan lunak. Untuk membandingkan kedua metode tersebut perlu diuji dengan bahan yang mempunyai kepadatan mineral tulang tertentu, phantom kalsium hidroksiapatit, dan diukur dengan kedua alat tersebut. Phantom kalsium hidroksiapatit dibuat dari jel agar-agar dan kalsium hidroksi apatit dalam kepadatan tertentu. Jaringan lunak dibuat dari jel agar-agar yang juga berfungsi sebagai fiksasi mineral tulang. Agar-agar merupakan polisakarida. Polisakarida dalam bentuk polimer adalah jel agar-agar, dalam darah adalah glukosa, dan dalam jaringan tulang adalah glikogen (diunduh dari www.elisa.ugm.ac.id pada tgl 22-3-2010). Beberapa komponen jaringan lunak tubuh terdiri atas glikogen dan air (diunduh dari www.nutrition.uvm..edu/bodycomp/dexa pada tgl 7-3-2008), sehingga jaringan lunak phantom kalsium hidroksiapatit mempunyai komponen seperti pada jaringan lunak. Mineral tulang dibuat dari kalsium hidroksi apatit yang merupakan komponen pembentuk jaringan keras tulang. Kalsium hidroksi apatit digunakan pada QCT sebagai phantom referensi (Siemens vol 1, 2005), sehingga jaringan keras phantom mempunyai komponen kalsium hidroksi apatit seperti komponen jaringan keras tulang. Phantom kalsium hidroksiapatit diperlukan dalam uji ini untuk mendapatkan bahan uji dengan komposisi tetap, sehingga mendapatkan hasil pengujian yang konsisten. 1.2 Perumusan Masalah Berdasarkan latar belakang tersebut maka perlu ditentukan hubungan antara nilai pengukuran kepadatan mineral tulang dengan Quantitative Computed Tomography dan Dual Energy X-ray Absorptiometry pada phantom mineral tulang dan cara membuat phantom kalsium hidroksiapatit dengan kepadatan mineral tertentu. 4

1.3 Batasan Masalah Dalam penelitian ini permasalahan dibatasi pada: 1. Pembuatan phantom kalsium hidroksiapatit dengan kepadatan mineral tertentu. 2. Pengukuran kepadatan mineral tulang phantom kalsium hidroksiapatit dengan menggunakan metode QCT dan DEXA. 1.4 Tujuan Penelitian Penelitian ini bertujuan : 1. Menerapkan pembuatan phantom kalsium hidroksiapatit dengan kepadatan mineral tertentu. 2. Menentukan hasil pengukuran kepadatan mineral tulang phantom kalsium hidroksiapatit dengan QCT dan DEXA. 3. Menentukan perbandingan hasil pengukuran kepadatan mineral tulang dan non mineral tulang phantom kalsium hidroksiapatit dari pengukuran QCT dan DEXA. 4. Menentukan hubungan pengujian kepadatan mineral tulang phantom kalsium hidroksiapatit antara QCT dan DEXA. 1.5 Manfaat Penelitian Manfaat penelitian bagi penulis : 1. Mempunyai kemampuan membuat phantom kalsium hidroksiapatit. 2. Mempunyai kemampuan melakukan pengukuran kepadatan mineral tulang dengan metode QCT dan DEXA. 3. Mempunyai pemahaman tentang karakteristik metode pengukuran kepadatan mineral tulang pada QCT dan DEXA. 4. Sumbangan ilmu pengetahuan tentang pembuatan phantom kalsium hidroksiapatit dan komparasi pengujian antara QCT dan DEXA. 5

DAFTAR PUSTAKA Adler, R.A., 2010, Osteoporosis Pathophysiology and Clinical Management, Humana Press, New York, USA. Attix, F.H., 2004, Introduction to Radiological Physics and Radiation Dosimetry, Wiley-VCH Verlag GmbH & Co KGaA, Weinheim, Germany. Avinash, C,K., Slaney, M., 1998, Principles of Computed Tomographic Imaging, IEEE Press, New York, USA. Bajpai, R.N., 1991, Osteologi Tubuh Manusia, Binarupa A, Jakarta. Buzug, T.M., 2008, Computed Tomography, From Photon Statistics to Modern Cone- Beam CT, Springer Verlag Berlin Heidelberg, Germany. Grampp, S., 2008, Radiology of Osteoporosis, Springer, Verlag Berlin Heidelberg, Germany. Hendee, W.R., Ritenour E.R., 2002, Medical Imaging Physics, Willey-Liss inc. New York, USA. Henderson, J.E., Goltzman, D., 2004, Osteoporosis Primer the, Cambridge University Press, Cambridge, United Kingdom. Heymsfield, S.B., Lohman, T.G., Wang, Z., Going, S.B., 2005, Human Body Composition, Human Kinetics, USA. Noz, M,E,, Maguire Jr, G.Q., 2006, Radiation Protection in the Health Science, World Sciencetific Publishing Co, Singapore. Park, J.B., Bronzino, J.D., 2003, Biomaterial : Principles and Applications, CRC Press, New York, USA. Pietrobelli, A., Wang, Z., Formica, C., Heymsfield, S.B., 1998, Dual Energy X-ray Absorptiometry : Fat Estimation Errors due to Variation in Soft Tissue Hydration, Am J Physiol Endocrinol Metab 274:808-816, New York, USA. Podgorsak, E.B., 2006, Radiation Physics for Medical Physicists, Springer, Verlag Berlin Heidelberg, Germany. Saefudin, A., Notodiputro, K.A., Alamudin, A., Sadik, K., 2009, Statistika Dasar, Grasindo, Jakarta, Indonesia. Seeram, E., 2000, Computed Tomography : Physical Principles, Clinical Applications, & Quality Control, W.B. Sounders, Pennsylvania, USA. Susilo, Wahyu Setia Budi, Kusminarto, Yunita Intan, 2009, Kajian Spine Phantom Dengan Teknik Radiografi Dexa, Prosiding Seminar Nasional ke-15 Teknologi dan Keselamatan PLTN serta Fasilitas Nuklir, Surakarta. Siemens, 2005, Syngo CT Operator Manual Volume 1, Siemensstrasse 1 : Germany. Siemens, 2005, Syngo CT Operator Manual Volume 4, Siemensstrasse 1 : Germany. Windarti, Tri., Siahaan, P., 2007, Struktur dan dinamika molekul material biokompatibel selulosa bacterial sebagai bahan dasar tulang artificial diunduh dari http://www.lemlit.undip.ac.id/abstrak/content/view/4651/277/ pada tgl 1-4- 2010. Windarti, Tri., Widodo, D.S., 2007, Material Komposit Biokompatibel Sebagai Implan Transplantasi Tulang diunduh dari http://www.lemlit.undip.ac.id/ abstrak/content/view/231/277/ pada tgl 1-4-2010. 6