Suparno, Makmur Rangkuty-PEMBUATAN KURVA PENYINARAN RADIOGRAFI IR-I92 MENGGUNAKAN PERSAMAAN DOSIS

dokumen-dokumen yang mirip
Suparno, Anda Sanusi - PENENTUAN WAKTU PENYINARAN RADlOGRAFllr-192 MENGGUNAKAN PERSAMAAN DOSIS RADIASI

Konversi Paparan pada Perubahan kv Pesawat Sinar- X Rigaku-RF-250EGM

UJI KARAKTERISTIK PENCAHAYAAN ILLUMINATOR RADIOGRAFI Supamo - Pusat Pendidikan dan Pelatihan BATAN

RADIOGRAFI PADA LAS MANHOLE BEJANA TEKAN. Djoli Soembogo Pusat Aplikasi Isotop dan Radiasi-BATAN ABSTRAK ABSTRACT

PEMERIKSAAN KUALITAS BOOM FOOT MENGGUNAKAN TEKNIK UJI TAK RUSAK

BAB IV ANALISA HASIL PENGUJIAN

RADIOGRAFI CO-60 PADA KUBUS CORAN TIMAH HITAM

PERANCANGAN RUANGAN RADIOTERAPI EKSTERNAL MENGGUNAKAN SUMBER Co-60

ANALISIS PERHITUNGAN KETEBALAN PERISAI RADIASI PERANGKAT RIA IP10.

PERANCANGAN RUANGAN RADIOTERAPI EKSTERNAL MENGGUNAKAN SUMBER Co-60

Analisa Kualitas Sinar-X Pada Variasi Ketebalan Filter Aluminium Terhadap Dosis Efektif

RADIOGRAFI Co-60 PADA CORAN KOMPONEN ALAT BERAT

PENENTUAN KARAKTERISASI CERROBEND SEBAGAI WEDGE FILTER PADA PESAWAT TELETERAPI 60 Co

PERANCANGAN PERISAI RADIASI PADA KEPALA SUMBER UNTUK PESAWAT RADIOTERAPI EKSTERNAL MENGGUNAKAN CO-60 PADA POSISI BEAM OFF

PERANCANGAN RUANGAN RADIOGRAFI MEDIK DI SEKOLAH TINGGI TEKNIK NUKLIR

PENGARUH GRID(KISI) LINIER TERHADAP KETAJAMAN DAN DENSITAS GAMBAR FILM RONTGEN PADA PEMOTOAN SCHEDEL LATERAL

PERANCANGAN PERISAI RADIASI PADA KEPALA SUMBER UNTUK PESAWAT RADIOTERAPI EKSTERNAL MENGGUNAKAN CO-60 PADA POSISI BEAM OFF

BAB III METODOLOGI PENELITIAN

ANALISIS PERHITUNGAN KETEBALAN KONTAINER PERALATAN BRAKITERAPI MDR UNTUK TERAPI KANKER LEHER RAHIM

PRA RANCANGAN KONTAINER TEMPAT PENYIMPANAN LIMBAH RADIOAKTIF SUMBER TERBUNGKUS 192 Ir

EXPOSUREMETRY. Soenarmo BATAN - PUSAT REAKTOR ATOM BANDUNG. Abstrakt:

METODA PENENTUAN DAYA SERAP PERISAI RADIASI UNTUK GONAD DARI KOMPOSIT LATEKS CAIR TIMBAL OKSIDA

Pengaruh Kecepatan Penguatan Lembar Penguat Terhadap Densitas Radiograf

PENENTUAN NILAI KOEFISIEN SERAPAN BAHAN PADA BESI, TEMBAGA DAN STAINLESS STEEL SEBAGAI BAHAN PERISAI RADIASI

KAJIAN APLIKASI RADIOGRAFI Ir 192 DAN Se 75 UNTUK INSPEKSI PIPA KETEL UAP PEMBANGKIT LISTRIK PLTU BATU BARA

PENENTUAN NILAI KOEFISIEN SERAPAN BAHAN DAN DOSIS RADIASI PADA VARIASI KOMBINASI KAYU DAN ALUMINIUM

PENGARUH TEGANGAN TABUNG (KV) TERHADAP KUALITAS CITRA RADIOGRAFI PESAWAT SINAR-X DIGITAL RADIOGRAPHY (DR) PADA PHANTOM ABDOMEN

PENGARUH LINEARITAS DAN RESIPROSITAS mas TERHADAP INTENSITAS RADIASI PADA PESAWAT SINAR-X MERK SAMSUNG

BAB I PENDAHULUAN 1.1 Latar Belakang

UJI KESESUAIAN PESAWAT CT-SCAN MEREK PHILIPS BRILIANCE 6 DENGAN PERATURAN KEPALA BAPETEN NOMOR 9 TAHUN 2011

ANALISIS PERHITUNGAN BERAT KONTAINER SUMBER Ir-192 AKTIVITAS 10 Ci UNTUK BRAKITERAPI HDR

Widyanuklida, Vol. 15 No. 1, November 2015: ISSN

ANALISA PENGARUH GRID RASIO DAN FAKTOR EKSPOSI TERHADAP GAMBARAN RADIOGRAFI PHANTOM THORAX

STUDI RADIOGRAFI MAKRO DENGAN VARIASI JARAK SUMBER SINAR-BAYANGAN (SID) DAN UKURAN FOKUS TERHADAP PEMBESARAN BAYANGAN

PENENTUAN TEBAL PERISAI RADIASI PERANGKAT RADIOTERAPI EKSTERNAL Co-60 UNTUK POSISI PENYINARAN

ABSTRAK DAN EXECUTIVE SUMMARY PENELITIAN HIBAH BERSAING

Pengaruh Ketidakhomogenan Medium pada Radioterapi

HUBUNGAN TEGANGAN DAN CITRA RADIOGRAFI REAL TIME PADA PESAWAT SINAR-X RIGAKU RADIOFLEX-250EGS3

RANCANGAN AWAL PERISAI RADIASI MESIN BERKAS ELEKTRON DUET

ANALISIS KUALITAS CITRA VERIFIKASI LAPANGAN RADIASI LINAC PADA KANKER PAYUDARA MENGGUNAKAN VARIASI MONITOR UNIT. Skripsi FRILYANSEN GAJAH

KAJIAN PENERIMAAN DOSIS RADIASI PADA PEKERJA D.A.LAM PROSES DISMANTLIN(3 SUMBER BEKAS

PENGUKURAN DOSIS RADIASI RUANGAN RADIOLOGI II RUMAH SAKIT GIGI DAN MULUT (RSGM) BAITURRAHMAH PADANG MENGGUNAKAN SURVEYMETER UNFORS-XI

RADIOGRAFI SINAR-X PADA TERUMBU KARANG

BAB I PENDAHULUAN 1.1 Latar Belakang Masalah

PENGARUH PERUBAHAN ENERGI RADIASI TERHADAP RESPON ENERGISURVEYMETER Anda Sanusi (Pusdiklat - Badan Tenaga Nuklir Nasional;

PENGUKURAN DOSIS PAPARAN RADIASI DI AREA RUANG CT SCAN DAN FLUOROSKOPI RSUD DR. SAIFUL ANWAR MALANG. Novita Rosyida

TANGGAPAN THERMOLUMINESCENT DOSIMETER CaSO 4 :Dy TERHADAP MEDAN RADIASI CAMPURAN BETA, GAMMA DAN MEDAN RADIASI CAMPURAN BETA GAMMA

INSPEKSI SAMBUNGAN LAS PADA PIPA STEAM GENERATOR MENGGUNAKAN METODE RADIOGRAPHY TEKNIK PANORAMIC (STUDI KASUS DI PT. TACHI JINO)

STUDI AWAL UJI PERANGKAT KAMERA GAMMA DUAL HEAD MODEL PENCITRAAN PLANAR (STATIK) MENGGUNAKAN SUMBER RADIASI MEDIUM ENERGY RADIUM-226 (Ra 226 )

UNIVERSITAS INDONESIA

PENGUJIAN LINIERITAS KELUARAN PEMBANGKIT ARUS SINAR X MENGGUNAKAN STEPWEDGE SKRIPSI. Evi Yusita Nim

OPTIMASI ALAT CACAH WBC ACCUSCAN-II UNTUK PENCACAHAN CONTOH URIN

PENGARUH DIAMETER PHANTOM DAN TEBAL SLICE TERHADAP NILAI CTDI PADA PEMERIKSAAN MENGGUNAKAN CT-SCAN

PENGARUH WAKTU MILLING TERHADAP SIFAT FISIS, SIFAT MAGNET DAN STRUKTUR KRISTAL PADA MAGNET BARIUM HEKSAFERIT SKRIPSI EKA F RAHMADHANI

PENGUKURAN FAKTOR WEDGE PADA PESAWAT TELETERAPI COBALT-60 : PERKIRAAN DAN PEMODELAN DENGAN SOFTWARE MCNPX.

DOSIMETER CAS04:DY BUATAN BARC SEBAGAI PEMANTAU DOSIS RADIASI PERORANGAN HP (10) Rofiq Syaifudin, Nina Herlina, dan Bambang Supriyanto PTKMR - BAT AN

Maintaining Quality Control by using general Radiological film

Maintaining Quality Control by using general Radiological film

PENENTUAN KEMBALI KOMPOSISI KOMPOSIT KARET ALAM TIMBAL OKSIDA SEBAGAI PERISAI RADIASI SINAR-X SESUAI KETENTUAN BAPETEN

KONTAINER SUMBER RADIASI 137CS 70 mci UNTUK PEMINDAI GAMMA

PENENTUAN DAYA SERAP APRON DARI KOMPOSIT KARET ALAM TIMBAL OKSIDA TERHADAP RADIASI SINAR- X

UJI HASIL KINERJA MESIN PENGOLAH FILM OTOMATIS MINI MEDICAL

KALIBRASI EFISIENSI α/β COUNTER UNTUK ANALISIS RADIONUKLIDA PEMANCAR BETA DALAM CONTOH URIN

PERBANDINGAN DOSIS RADIASI DI UDARA TERHADAP DOSIS RADIASI DI PERMUKAAN PHANTOM PADA PESAWAT CT-SCAN

PERSENTASE DOSIS KEDALAMAN (PDD) PADA PESAWAT TELETERAPI CO-60. Fisikawan medik Habib Syeh Az /

Perancangan Keselamatan Ruangan Radiologi Pesawat Sinar-X Di PSTA BATAN Yogyakarta

Youngster Physics Journal ISSN : Vol. 2, No. 1, April 2013, Hal 27-34

KAJIAN LAJU PAPARAN RADIASI PADA TITIK PENGUKURAN DI REAKTOR KARTINI SEBAGAI DASAR PENENTUAN KONDISI BATAS OPERASI (KBO)

KAJIAN PENGARUH WARNA DAN JARAK LAMPU PENGAMAN TERHADAP HASIL RADIOGRAF

KARAKTERISTIK SIFAT MEKANIS DAN STRUKTUR MIKRO PROSES AUSTEMPER PADA BAJA KARBON S 45 C DAN S 60 C

Pengukuran Dosis Radiasi dan Estimasi Efek Biologis yang Diterima Pasien Radiografi Gigi Anak Menggunakan TLD-100 pada Titik Pengukuran Mata dan Timus

ANALISA PENGARUH VARIASI LAJU ALIRAN UDARA TERHADAP EFEKTIVITAS HEAT EXCHANGER MEMANFAATKAN ENERGI PANAS LPG

ANALISIS PAPARAN RADIASI LINGKUNGAN RUANG RADIOLOGI DI RUMAH SAKIT DENGAN PROGRAM DELPHI

PERANCANGAN KONSUL UNTUK OPERATOR PADA PEREKAYASAAN PESAWAT SINAR-X MAMOGRAFI

ANALISIS PENGARUH GRID TERHADAP PENYIMPANGAN BENTUK DAN UKURAN OBJEK (DISTORSI)

Penentuan Dosis Gamma Pada Fasilitas Iradiasi Reaktor Kartini Setelah Shut Down

PENGUKURAN LAJU DOSIS PAPARAN RADIASI EKSTERNAL DI AREA RADIOTERAPI RSUD DR. SAIFUL ANWAR MALANG. Diterima: 6 Juni 2016 Layak Terbit: 25 Juli 2016

PRARANCANGAN SISTEM LOADING DAN UNLOADING PADA KOLOM PENUKAR ION PENGOLAH LIMBAH RADIOAKTIF

Analisis Pengaruh Sudut Penyinaran terhadap Dosis Permukaan Fantom Berkas Radiasi Gamma Co-60 pada Pesawat Radioterapi

OPTIMALISASI DOSIS RADIASI SINAR-X TERHADAP PROYEKSI PA (POSTERO-ANTERIOR) DAN LAT (LATERAL) PADA TEKNIK PEMERIKSAAN FOTO THORAX SKRIPSI

Pemeriksaan secara visual dengan mata, kadang kadang memakai kaca pembesar. 2.

EVALUASI TEBAL DINDING RUANGAN PESAWAT LINEAR ACCELERATOR (LINAC) SINAR-X DI INSTALASI RADIOTERAPI RUMAH SAKIT UNIVERSITAS HASANUDDIN

ANALISA PENGARUH FAKTOR EKSPOSI TERHADAP ENTRANCE SURFACE AIR KERMA (ESAK)

DAFTAR ISI. HALAMAN JUDUL... i. PERNYATAAN BEBAS PLAGIARISME... ii. HALAMAN PENGESAHAN... iii. HALAMAN TUGAS... iv. HALAMAN PERSEMBAHAN...

FABRIKASI DETEKTOR PARTIKEL ALPHA MENGGUNAKAN SEMIKONDUKTOR SILIKON TIPE P

ANALISA PENGARUH ph TERHADAP PERUBAHAN NILAI DENSITAS OPTIK (OPTICAL DENSITY) PADA FILM DENGAN VARIASI JENIS DEVELOPER

KAJIAN PENGARUH WARNA DAN JARAK LAMPU PENGAMAN TERHADAP HASIL RADIOGRAF

UJI IMAGE UNIFORMITY PERANGKAT COMPUTED RADIOGRAPHY DENGAN METODE PENGOLAHAN CITRA DIGITAL

PROGRAM JAMINAN KUALITAS PADA PENGUKURAN. RADIONUKLIDA PEMANCAR GAMMA ENERGI RENDAH:RADIONUKLIDA Pb-210

08/01/2012. Pengujian Visual Las. Pengujian Dye Penetrant. Pengujian Serbuk Magnet PENGUJIAN TIDAK MERUSAK. Pengujian Ultrasonik. Pengujian Arus Eddy

ANALISIS KESELAMATAN RADIASI PADA LABORATORIUM SINAR-X INDUSTRI STTN BATAN YOGYAKARTA

STUDI AWAL UJI PERANGKAT KAMERA GAMMA DUAL HEAD MODEL PENCITRAAN PLANAR STATIK MENGGUNAKAN SUMBER RADIASI HIGH ENERGY IODIUM-131 (I 131 )

LAPORAN PRAKTIKUM PENGUJIAN TANPA MERUSAK

PENGEMBANGAN PROGRAM PERHITUNGAN KOEFISIEN DIFUSI MATERIAL DALAM REKAYASA PERMUKAAN

Penentuan Perubahan 'rebal dengan Metode Variasi Densitas Film

PENENTUAN NILAI TEBAL PARUH (HVL) PADA CITRA DIGITAL COMPUTED RADIOGRAPHY

Desain Ulang Shielding Ruangan Linear Accelerator (Linac) untuk Keselamatan Radiasi Di Gedung 14 PSTA-BATAN Yogyakarta

STANDAR NASIONAL INDONESIA (SNI) BIDANG NUKLIR

PENGARUH RADIASI HAMBUR TERHADAP KONTRAS RADIOGRAFI AKIBAT VARIASI KETEBALAN OBYEK DAN LUAS LAPANGAN PENYINARAN MUHAMMAD SYARIF BODDY

DENSITOMETER FILM RADIOGRAFI PORTABEL BERBASIS MIKROKONTROLER ABSTRAK

Transkripsi:

Suparno, Makmur Rangkuty-PEMBUATAN KURVA PENYINARAN RADIOGRAFI IR-I92 PEMBUAIAN KURVA PENYINARAN RADIOGRAFI IR-l92 Suparno, Makmur Rangkuty Pusat Pendidikan dan Pelatihan BATAN, parnomrj@batan.go.id ABSTRAK PEMBUATAN KURVA PENYINARAN RADIOGRAFI Ir-192. Telah dilakukan pembuatan kurva penyinaran radiografi dengan sumber radiasi Ir-192. Kurva penyinara adalah kurva hubungan antara ketebalan material dengan paparan (curie menit). Kurva penyinaran dibuat dengan melakukan sederet penyinaran radiografi pad a sebuah step-wedge dengan waktu penyinaran yang berbeda. Penentuan waktu penyinaran dilakukan dengan perhitungan menggunakan persamaan dosis radiasi. Perhitungan dilakukan dengan mengacu nilai dosis 1400 mrem. Kurva penyinaran dibuat dengan regresi linier hubungan antara tebal (X) sebagai absis dan logaritma paparan (Log E) sebagai ordinat, menggunakan CALCULATOR CASIO FX-350MS. Kurva yang dihasilkan memiliki persamaan Log E = 1,72153 + (0,022115 X) curie men it. Hasil uji radiografi terhadap kurva penyinaran pada tiga variasi ketebalan material menghasilkan nilai densitas 2,64; 2,43; 2,51. Kata Kunci : Radiografi, kurva penyinaran (exposure chart), persamaan dosis radiasi ABSTRACT MAKING Ir-l92 RADIOGRAPHIC EXPOSURE CHART USING THE RADIATION DOSE EQUATION. Making radiographic exposure chart of Ir- 192 radiation source has been performed. Exposure chart is a curve that related between material thickness with exposure (curie minute). Exposure chart created by conducting a series of radiographic exposure on a step-wedge with exposure time varying. Determination of exposure time is done with calculations using the radiation dose equations. The calculation is performed with reference 10 the value of 1400 mrem of radiation dose. Exposure chart was made by linear regression relationship between the thickness (X) as the abscissa and the logarithm of exposure (log E) as ordinate, using CALCULATOR CASIO FX-350MS. The resulting curve has thz equation log E = 1.72153 + (0.022115 X) curie minutes. Radiographic test results of the exposure chart at three variations of the thickness of the material produced density values of2.64; 2.43; 2.51. PENDAHULUAN Dalam melakukan UJI radiografi suatu material, keberhasilan pembuatan radiograf (film hasil radiografi) antara lain dipengaruhi oleh ketepatan menentukan waktu penyinaran. Untuk keperluan tersebut digunakan suatu kurva yang disebut kurva penyinaran (exposure chart). 47

Widyanuklida Vol. 13 No. I, November 2013 Kurva penyinaran (exposure chart) adalah kurva yang menghubungkan antara tebal material dan paparan untuk energi radiasi (sumber radiasi) tertentu. Kurva penyinaran hanya berlaku untuk sumber radiasi, material, sistem film, dan kondisi pemrosesan tertentu. Untuk meradiografi material yang berbeda diperlukan kurva penyinaran yang berbeda pula. Begitu pentingnya kurva penyinaran dalam pekerjaan radiografi, maka pembuatan kurva penyinaran dijadikan materi praktikum dalam pelatihan radiografi Level 2 di Pusdiklat BATAN. Kurva penyinaran dibuat dengan melakukan sederet penyinaran radiografi pada sebuah step-wedge dengan waktu penyinaran yang berbeda-beda. Selama ini penentuan waktu penyinaran dilakukan secara cobacoba (trial and error). Keberhasilan dari pembuatan kurva penyinaran ditentukan oleh pemilihan waktu penyinaran yang tepat sesuai dengan ketebalan step-wedge yang tersedia. Untuk keperluan tersebut, diperkenalkan cara penentuan waktu penyinaran menggunakan persamaan dosis, yaitu : x=x t (1) TATAKERJA Pembuatan kurva penyinaran diawali dengan melakukan 10 kali penyinaran pada sebuah step-wedge dari bahan carbon-steel yang memiliki 10 step dengan ketebalan masing-rnasing 6,8 mm, 11,4 mm, dengan X paparan absolut radiasi, X laju paparan, dan t waktu penyinaran. Untuk menerapkan persamaan tersebut, diperlukan data-data dan persamaan sebagai berikut : 1) Nilai paparan absolut radiasi pad a sistem film untuk mendapatkan densitas film 2. Untuk sistem film AGF A 07 dengan sumber Ir-I92, besarnya nilai paparan menurut hasil penelitian adalah 1400 mr (Supamo et all, 2012) 2) Laju paparan X pada permukaan film yang berjarak SFO (jarak sumber ke film) setelah menembus step wedge, dapat ditentukan dengan persamaan berikut X = ra - 0,693 x e HVL SFD 2 (2) dengan, A aktivitas sumber radiasi (dalam Ci), SFO jarak sumber ke film dan r adalah faktor gamma yan untuk lr-i92 nilainya 0,5 f Rm IJam Ci, x tebal step wedge, HVL tebal paro yang nilainya untuk besi adalah 13 mm. 16, I mm, 20,8 mm, 25,7 mm, 30,4 mm, 35,1 mm, 39,8 mm, 44,9 mm, dan 49,7' mm. Penyinaran dilakukan pada SFO 610 mm menggunakan sumber radiasi lr-l92 dengan aktivitas 41,8 Ci. Sistem film yang digunakan terdiri atas film AGF A 07 dengan skrin 48

Suparno, Makmur Rangkuty-PEMBUATAN KURVA PENYINARAN RADIOGRAFIIR-I92 lembaran timbal depan dan belakang rnasing-rnasing memiliki ketebalan 0,125 mm. Waktu penyinaran dihitung menggunakan persamaan 1 dan 2. Perhitungan waktu penyinaran pertama didasarkan ketebalan step I, penyinaran berikutnya didasarkan pada ketebalan step 2,3,4, 5, 6, 7, 8, 9, dan 10. Susunan geometri penyinaran dibuat sedemikian rupa sehingga ketebalan step yang menjadi dasar perhitungan berada pada pusat berkas. Pada penyinaran pertama, yang berada pada pusat berkas adalah step 1, pad a penyinaran berikutnya secara bergantian yang berada di pusat berkas adalah step 2, 3, 4,5,6, 7, 8, 9, dan 10. Semua film yang telah disinari diproses secara bersamaan dalam ruang proses film dengan waktu dan temperatur developer standar (5 menit 20 C). Setelah selesai pemrosesan, dilakukan pengukuran densitas pada semua gambar step pada setiap radiograf. Pengukuran densitas menggunakan densitometer FIDGEON. DATA DAN ANALISA DATA Nilai paparan absolut radiasi pada sistem film untuk mendapatkan densitas film 2 untuk sistem film AGF A D7 dengan sumber Ir-l92 adalah 1400 mr. Mengacu pada nilai paparan tersebut, kemudian dilakukan perhitungan waktu penyinaran untuk setiap ketebalan step-wedge menggunakan persamaan 1 dan 2. Hasil perhitungan waktu penyinaran dinyatakan 1. dalam Tabel Tabel I : Hasil Perhitungan Waktu Penyinaran Step-Wedge Dengan waktu yang telah ditentukan, dilakukan radiografi terhadap step-wedge. Film hasil radiografi kemudian diproses dan diukur densitasnya menggunakan densitometer. Hasil pengukuran densitas untuk setiap radiograf ~. No. Step Tebal step (mm) Waktu (menit) 1 6,8 2,14 2 11,4 2,7 3 16,1 3,5 4 20,8 4,5 5 25,7 5,9 6 30,4 7,6 7 35,1 9,7 8 39,8 12,5 9 44,9 16,4 10 49,7 21,2 -- dinyatakan dalam Tabel 2. Dari data terse but tampak bahwa terdapat 9 film (film nomor 1 sampai nomor 9) memiliki rentang densitas yang menyeberang pada nilai densitas 2. Sedangkan, 1 buah film (nomor 10) rentang densitasnya tidak menyeberang pada nilai densitas 2. 49

Widyanuklida Vol. 13 No. I, November 2013 Tabel2: Hasil Pengukuran Densitas Pada Film Hasil Radiografi Step-Wedge No. Waktu Densitas Paparan Film (menit) Ci. Menit step step step step step step step step step step E=A. t I 2 3 4 5 6 7 8 9 10 I 2,14 2,24 1,94 1,65 1,39 89,45 2 2,7 2,73 2,29 1,96 1,58 1,28 112,86 3 3,5 3,20 2,77 2,35 1,95 1,59 1,28 146,3 4 4,5 3,60 3,06 2,53 2,02 1,61 1,27 188,1 5 5,9 3,68 3,08 2,55 2,05 1,65 1,31 246,6 6 7,6 3,83 3,17 2,65 2,14 1,72 1,40 I,ll 317,7 7 9,7 3,75 3,06 2,53 2,08 1,63 1,25 405,5 8 12,5 3,92 3,18 2,62 2,06 1,57 522,5 9 16,4 I 4,00 3,25 2,47 1,96 685,5 10 21,2 3,73 3,10 2,31 886,16 4 3.5.. '" to 3 2.5 'v; c 2 QI Q 1.5 1 0.5 0! "" ~~~'n_.,_,y_"... ~ 0 10 Tebal (mm) Gambar 1 : Kurva Hubungan Antara Tebal Dengan Densitas Pada Setiap Nilai Paparan (Exposure) 50

Suparno, Makmur Rangkuty-PEMBUATAN KURVA PENYINARAN RADIOGRAFI IR-192 MENGGUJ'lAKAN PERSAMAAN DOSIS Berdasarkan data pada Tabel 2, selanjutnya dibuat kurva hubungan antara tebal material dengan densitas untuk film nom or 1 sampai nomor 9, seperti ditunjukkan pada Gambar 1. Data pada film nomor 1 tidak dapat digunakan karena rentang densitasnya tidak menyeberang pada nilai densitas 2. Dari kurva pada gambar 1 kemudian ditentukan nilai ketebalan untuk masing-masing paparan pada nilai densitas 2. Data tersebut dinyatakan dalarn Tabel 3. Tabel 3: Data Hubungan Tebal (Mm) Dan Paparan (Ci Menit) Pada Densitas 2 Tebal (mm) Paparan (E, Ci men it) Logaritma Paparan (Log E) 10,5 89,45 1,951 14,5 112,86 2,052 19,5 146,3 2,165 25,S 188,1 2,274 30,S 246,6 2,392 36,0 317,7 2,502 40,0 405,5 2,608 46,0 522,5 2,718 49,0 685,5 2,836 Mengacu data pada Tabel 3, dibuat regresi linier hubungan antara tebal (X) sebagai absis dan logaritma paparan (Log E) sebagai ordmat. Regresi linier dibuat dengan rumus : LogE=A+ BX Nilai A dan B diperoleh dari calculator yang memiliki mode Regresi Linier, yang dalam tulisan ini digunakan CALCULATOR CASIO FX-350MS I dengan langkah sebagai ~ Mang.I""".o fungsi Reg"'" Un r berikut: (MODE 100 Dari langkah tersebut, 2. Mem~rsihbn ~ri diperoleh nilai A = 1,72153 dan B = 0,022115, dan 3. M~mas'Ukkan Oat.. persamaan regresi liniernya adalah Xl [=~] Log E = 1,72153 + x2d O,022115x Xn! -~ Log En [!.l+ (OAT.>,) J Dengan mengacu pada persamaan regresi linier NiiaiA- (persamaan 4) kemudian dibuat kurva penyinaran pada NilaIBkertas semi logaritma dengan 51

Widyanuklida Vol. 13 No.1, November 2013 tebal (X) sebagai absis dan paparan (E) sebagai ordinat. Untuk pembuatan kurva dipilih dua nilai ketebalan sembarang, dalam hal ini dipilih tebal 10 mm dan 40 mm. Hasil perhitungan dengan persamaan 4 untuk tebal 10 mm diperoleh nilai Log E = 1,94268 dan nilai E = antilog 1,94268 87,63 ci men it, sedangkan untuk tebal 40 mm diperoleh nilai Log E = 2,60613 dan nilai E = antilog 2,60613 = 403,76 ci menit. Kurva yang dihasilkan dari data tersebut dapat dilihat pada Gambar 2. 100ll Somber : Ir 192 Malo(\al :Fe SFD!10 mm EXPOSURE CHART IR-192 Fflrn AGFA07 2 Oensita! Lead 0, US rrm 200C (5 menlo) Log y. ',72153. (0,022115 Xl z- '2 OJ E 8100 10 0 10 20 30 Tebal(mm) Gambar 2 : Kurva Penyinaran Hasil Percobaan Kurva penyinaran yang dihasilkan kemudian diuji dengan melakukan penyinaran radiografi terhadap lempeng besi tipis (ketebalan kurang dari 15 mm), sedang (ketebalan antara 15 mm sampai dengan 30 mm), dan tebal (ketebalan lebih dari 30 mm). Data hasil. pengukuran ditunjukkan pada Tabel 4. TabID e. 4: ata Hasil Pengujian Kurva Penyinaran No. Tebal Material SFD(mm) Exposure (Ci Aktivitas Waktu Densitas (mm) men it) (Ci) (rnenit) I 11,4 500 94,59 5,7 11,34 2,64 2 25,7 500 197,93 5,7 2374 2,43 3 35,1 500 329,35 5,7 39,51 2,51 52

Suparno, Makmur Rangkuty-PEMBUATAN KURVA PENYINARAN RADIOGRAFIIR-l92 KESIMPULAN 1. Pembuatan kurva penyinaran menggunakan persamaan dosis akan memberikan kepastian hasil, ini terbukti dari 10 buah film yang yang dipapari terdapat 9 buah film yang datanya layak untuk digunakan. Kurva penyinaran yang dihasilkan memiliki persamaan : Log E = 1,72153 + 0,022115 X. 2. Hasil uji kurva penyinaran pada tiga variasi ketebalan menghasilkan nilai densitas 2,64; 2,43; 2,51. Nilai tersebut berada pada rentang densitas yang direkomendasikan oleh standar ASME V, yaitu 2 sampai 4. DAFTAR PUSTAKA [1] Supamo et all, 2012, Penentuan Waktu Penyinaran Radiografi Ir-I92 Menggunakan Persamaan Dosis, Widyanuklida Volume 12 Nomor 1 [2] Cartz, Louis, 1995, Nondestructive Testing "Radiography, Ultrasonics, Liquid Penetrant, Magnetic Particle, Eddy Current", ASM International, First printing [3] Cember, Herman, 1992, Introduction to Health Physics, McGraw-Hill, Inc., Second Edition [4] Davis Joseph R. et all, 1989, ASM Handbook, Volume 17, Nondestructive Evaluation and Quality Control, ASM International, USA 53