STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM LINGKARAN BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP ABSTRAK

dokumen-dokumen yang mirip
STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM PERSEGI BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP ABSTRAK

STUDI EKSPERIMENTAL VARIASI TULANGAN SENGKANG PADA KOLOM PERSEGI ABSTRAK

STUDI EKSPERIMENTAL PERBAIKAN KOLOM LINGKARAN BETON BERTULANG ABSTRAK

STUDI EKSPERIMENTAL PERBAIKAN KOLOM PERSEGI BETON BERTULANG ABSTRAK

STUDI EKSPERIMENTAL EFEKTIVITAS PENGEKANGAN KOLOM LINGKARAN DENGAN MENGGUNAKAN PEN-BINDER ABSTRAK

STUDI EKSPERIMENTAL EFEKTIVITAS PENGEKANGAN KOLOM LINGKARAN DENGAN MENGGUNAKAN FRP (FIBER REINFORCED POLYMER) ABSTRAK

DAFTAR ISI JUDUL PENGESAHAN PERNYATAAN BEBAS PLAGIASI ABSTRAK ABSTRACT KATA PENGANTAR

STUDI EKSPERIMENTAL PENGGUNAAN FRP (FIBER REINFORCED POLYMER)TERHADAP PERKUATAN KOLOM BETON BERTULANG ABSTRAK

STUDI EKSPERIMENTAL PENGGUNAAN PEN- BINDER TERHADAP PERKUATAN KOLOM BETON BERTULANG ABSTRAK

PERHITUNGAN DAN PENGGAMBARAN DIAGRAM INTERAKSI KOLOM BETON BERTULANG DENGAN PENAMPANG PERSEGI. Oleh : Ratna Eviantika. : Winarni Hadipratomo, Ir.

STUDI EKSPERIMENTAL PENGGUNAAN PORTLAND COMPOSITE CEMENT TERHADAP KUAT LENTUR BETON DENGAN f c = 40 MPa PADA BENDA UJI BALOK 600 X 150 X 150 mm 3

BAB II TINJAUAN PUSTAKA

ANALISIS LENTUR DAN GESER BALOK PRACETAK DENGAN TULANGAN SENGKANG KHUSUS ABSTRAK

PERILAKU KERUNTUHAN BALOK BETON BERTULANG TULANGAN GANDA ABSTRAK

ANALISIS DAKTILITAS BALOK BETON BERTULANG

d b = Diameter nominal batang tulangan, kawat atau strand prategang D = Beban mati atau momen dan gaya dalam yang berhubungan dengan beban mati e = Ek

Universitas Sumatera Utara

Kata Kunci : beton, baja tulangan, panjang lewatan, Sikadur -31 CF Normal

PERILAKU BALOK BERTULANG YANG DIBERI PERKUATAN GESER MENGGUNAKAN LEMBARAN WOVEN CARBON FIBER

STUDI ANALISIS PERTEMUAN BALOK KOLOM BERBENTUK T STRUKTUR RANGKA BETON BERTULANG DENGAN PEMODELAN STRUT-AND- TIE ABSTRAK

PERBAIKAN KOLOM LANGSING BETON BERTULANG MENGGUNAKAN FIBER GLASS JACKET DENGAN VARIASI TINGKAT KERUSAKAN

PENGARUH GAYA AKSIAL TERHADAP LUAS TULANGAN PENGEKANG KOLOM BETON BERTULANG PERSEGI ABSTRAK

UNIVERSITAS KRISTEN MARANATHA FAKULTAS TEKNIK JURUSAN TEKNIK SIPIL BANDUNG

STRUKTUR BETON BERTULANG II

STUDI EKSPERIMENTAL PENGARUH PENGGUNAAN PS BALL SEBAGAI PENGGANTI PASIR TERHADAP KUAT LENTUR BETON

KEKUATAN SAMBUNGAN BALOK BETON BERTULANG DENGAN SIKADUR -31 CF NORMAL

PEMODELAN NUMERIK METODE ELEMEN HINGGA NONLINIER STRUKTUR BALOK TINGGI BETON BERTULANG ABSTRAK

ANALISA KINERJA STRUKTUR BETON BERTULANG DENGAN KOLOM YANG DIPERKUAT DENGAN LAPIS CARBON FIBER REINFORCED POLYMER (CFRP)

BAB I PENDAHULUAN Latar Belakang. Kolom memegang peranan penting dari suatu bangunan karena memikul

DESAIN TAHAN GEMPA BETON BERTULANG PENAHAN MOMEN MENENGAH BERDASARKAN SNI BETON DAN SNI GEMPA

STUDI EKSPERIMENTAL PENGARUH PENAMBAHAN SUPERPLASTICIZER TERHADAP KUAT LENTUR BETON RINGAN ALWA MUTU RENCANA f c = 35 MPa

3.4.2 Pemeriksaan Berat Jenis dan Penyerapan Air Agregat Halus Error! Bookmark not defined Kadar Lumpur dalam Agregat... Error!

PERKUATAN KOLOM BETON BERTULANG DENGAN GLASS FIBER JACKET UNTUK MENINGKATKAN KAPASITAS BEBAN AKSIAL (034S)

SUB JURUSAN STRUKTUR DEPARTEMEN TEKNIK SIPIL FAKULTAS TEKNIK UNIVERSITAS SUMATERA UTARA MEDAN 2016

PERILAKU BALOK BETON BERTULANG DENGAN PERKUATAN PELAT BAJA DALAM MEMIKUL LENTUR (Penelitian) NOMI NOVITA SITEPU

PENGARUH JARAK SENGKANG TERHADAP KAPASITAS BEBAN AKSIAL MAKSIMUM KOLOM BETON BERPENAMPANG LINGKARAN DAN SEGI EMPAT

LEMBAR PENGESAHAN TUGAS AKHIR

STUDI EKSPERIMENTAL KUAT LENTUR PADA BALOK BETON BERTULANG DENGAN PERKUATAN BAJA RINGAN PROFIL U TUGAS AKHIR. Disusun oleh : LOLIANDY

PERILAKU LENTUR KOLOM BETON PIPIH DENGAN TULANGAN BAMBU

TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG KANTOR PERPAJAKAN PUSAT KOTA SEMARANG

ANALISIS LENDUTAN SEKETIKA dan LENDUTAN JANGKA PANJANG PADA STRUKTUR BALOK. William Trisina NRP : Pembimbing : Daud Rahmat Wiyono, Ir.,M.Sc.

BAB II TINJAUAN PUSTAKA

TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG PERPUSTAKAAN PUSAT YSKI SEMARANG

PEMROGRAMAN ANALISIS KAPASITAS KOLOM DENGAN VARIASI MUTU BETON DALAM SATU PENAMPANG

PERENCANAAN STRUKTUR RANGKA BAJA BRESING TAHAN GEMPA

PERBAIKAN KOLOM BETON BERTULANG MENGGUNAKAN GLASS FIBER JACKET DENGAN VARIASI TINGKAT PEMBEBANAN

STUDI EKSPERIMENTAL PENGARUH BERBAGAI KADAR VISCOCRETE PADA BERBAGAI UMUR KUAT TEKAN BETON MUTU TINGGI f c = 45 MPa

BAB III LANDASAN TEORI

PERENCANAAN STRUKTUR GEDUNG ASRAMA MAHASISWA UNIVERSITAS DIPONEGORO SEMARANG

PERBANDINGAN KEKUATAN KOLOM PENDEK BETON BERTULANG DENGAN PENAMBAHAN VARIASI UKURAN PROFIL BAJA SIKU YANG DIKENAI BEBAN KONSENTRIK

1.2) Kolom Tampang L a) Kondisi Regangan Berimbang b) Kondisi Tekan Menentukan c) Kondisi Tarik Menentukan BAB III.

PERKUATAN KOLOM BETON BERTULANG DENGAN FIBER GLASS JACKET PADA KONDISI KERUNTUHAN TARIK

PENGARUH JARAK SENGKANG BAJA DARI METODE JAKET BETON BERTULANGAN BAMBU PADA KOLOM BERTULANGAN RINGAN

Studi Eksperimental Penggunaan Pen-Binder dan FRP sebagai Perkuatan Tulangan Tidak Standar pada Kolom Lingkaran

STUDI KUAT LENTUR BALOK DENGAN PENAMBAHAN GLENIUM ACE 8590

EVALUASI PERBANDINGAN KONSEP DESAIN DINDING GESER TAHAN GEMPA BERDASARKAN SNI BETON

STUDI PERILAKU MEKANIK KEKUATAN BETON RINGAN TERHADAP KUAT LENTUR BALOK

BAB I PENDAHULUAN 1.1 LATAR BELAKANG

BAB 1. PENGENALAN BETON BERTULANG

ANALISIS DAN EKSPERIMENTAL PERHITUNGAN DAKTILITAS BALOK BETON BERTULANG ABSTRAK

LEMBAR PENGESAHAN Tugas Akhir Sarjana Strata Satu (S-1)

DAFTAR ISI HALAMAN JUDUL...

PERENCANAAN GEDUNG BETON BERTULANG BERATURAN BERDASARKAN SNI DAN FEMA 450

Perencanaan Kolom Beton Bertulang terhadap Kombinasi Lentur dan Beban Aksial. Struktur Beton 1

PERANCANGAN STRUKTUR ATAS GEDUNG CONDOTEL MATARAM CITY YOGYAKARTA. Oleh : KEVIN IMMANUEL KUSUMA NPM. :

BAB III LANDASAN TEORI

L p. L r. L x L y L n. M c. M p. M g. M pr. M n M nc. M nx M ny M lx M ly M tx. xxi

ANALISIS DAN DESAIN STRUKTUR TAHAN GEMPA DENGAN SISTEM BALOK ANAK DAN BALOK INDUK MENGGUNAKAN PELAT SEARAH

Augustinus NRP : Pembimbing : Ny. Winarni Hadipratomo, Ir. FAKULTAS TEKNIK JURUSAN TEKNIK SIPIL UNIVERSITAS KRISTEN MARANATHA BANDUNG

STUDI EKSPERIMENTAL PENGARUH PENYELIMUTAN BETON DENGAN LEMKRA FIRE PROOFING TERHADAP KUAT BETON AKIBAT PEMBAKARAN

PENGUJIAN KUAT LENTUR PANEL PELAT BETON RINGAN PRACETAK BERONGGA DENGAN PENAMBAHAN SILICA FUME

1. PENDAHULUAN 1.1. BETON

BAB II TINJAUAN PUSTAKA. tengah sekitar 0,005 mm 0,01 mm. Serat ini dapat dipintal menjadi benang atau

1 HALAMAN JUDUL TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG SEKOLAH MENENGAH PERTAMA TRI TUNGGAL SEMARANG

STUDI PERBANDINGAN ANALISIS PELAT KONVENSIONAL DAN PELAT PRACETAK ABSTRAK

STUDI EKSPERIMENTAL PENGGUNAAN BETON RECYCLE SEBAGAI AGREGAT KASAR PADA BETON TERHADAP KUAT TARIK BELAH. DENGAN MUTU RENCANA f c = 25 MPa

Heru Indra Siregar NRP : Pembimbing : Ny. Winarni Hadipratomo, Ir. FAKULTAS TEKNIK JURUSAN TEKNIK SIPIL UNIVERSITAS KRISTEN MARANATHA

PENGUJIAN LENTUR BALOK BETON BERTULANG DENGAN MENGGUNAKAN MODIFIKASI ALAT UJI TEKAN

PERANCANGAN STRUKTUR ATAS GEDUNG TRANS NATIONAL CRIME CENTER MABES POLRI JAKARTA. Oleh : LEONARDO TRI PUTRA SIRAIT NPM.

ANALISA DAN PENGUJIAN KEKUATAN BALOK BETON BERTULANG BERLUBANG PENAMPANG PERSEGI TUGAS AKHIR. Disusun oleh : Dosen Pembimbing

PENGARUH VARIASI KADAR LIGHTWEIGHT EXPANDED CLAY AGGREGATE (LECA) TERHADAP KARAKTERISTIK BETON SERAT BAGU

DAFTAR ISI. HALAMAN JUDUL... i. HALAMAN PENGESAHAN...ii. HALAMAN PERNYATAAN... iii. KATA PENGANTAR... iv. HALAMAN PERSEMBAHAN... vi. DAFTAR ISI...

PENGGAMBARAN DIAGRAM INTERAKSI KOLOM BAJA BERDASARKAN TATA CARA PERENCANAAN STRUKTUR BAJA UNTUK BANGUNAN GEDUNG (SNI ) MENGGUNAKAN MATLAB

BAB II TINJAUAN PUSTAKA

STUDI EKSPERIMENTAL KUAT LENTUR PADA BALOK BETON BERTULANG DENGAN PERKUATAN BAJA RINGAN PROFIL U DI DAERAH TARIK ANDREANUS MOOY TAMBUNAN

BAB III LANDASAN TEORI. Menurut McComac dan Nelson dalam bukunya yang berjudul Structural

ANALISIS DINAMIK RAGAM SPEKTRUM RESPONS GEDUNG TIDAK BERATURAN DENGAN MENGGUNAKAN SNI DAN ASCE 7-05

STUDI EKSPERIMENTAL PENGGUNAAN PECAHAN BETON RECYCLE SEBAGAI AGREGAT KASAR PADA BETON DENGAN MUTU RENCANA f c = 25 MPa

PERENCANAAN STRUKTUR GEDUNG RUSUNAWA UNIMUS

Kata kunci: daktilitas regangan, kapasitas aksial kolom, sengkang, kolom penampang pipih, Galvanised Welded Wire Fabric, diagram tegangan-regangan.

PERENCANAAN STRUKTUR UNIT GEDUNG A UNIVERSITAS IKIP VETERAN SEMARANG

STUDI EKSPERIMEN KAPASITAS TARIK DAN LENTUR PENJEPIT CONFINEMENT KOLOM BETON

III. METODE PENELITIAN

BAB I PENDAHULUAN 1.1 Latar Belakang

ANALISIS METODE ELEMEN HINGGA DAN EKSPERIMENTAL PERHITUNGAN KURVA BEBAN-LENDUTAN BALOK BAJA ABSTRAK

PENGARUH SUBSTITUSI AGREGAT HALUS DENGAN KERAK BOILER TERHADAP BETON TUGAS AKHIR. Disusun oleh : JEFFRY NIM:

BAB III LANDASAN TEORI. beban hidup dan beban mati pada lantai yang selanjutnya akan disalurkan ke

DAFTAR ISI BAB I PENDAHULUAN... 1

BAB II STUDI PUSTAKA

BAB II TINJAUAN PUSTAKA

Transkripsi:

STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM LINGKARAN BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP Ricky Candra Wijaya 1221008 Pembimbing: Dr. Anang Kristianto, S.T., M.T. ABSTRAK Gempa bumi adalah getaran atau guncangan yang terjadi di permukaan bumi akibat pelepasan energi dari dalam secara tiba-tiba yang menciptakan gelombang seismik. Gempa bumi biasa disebabkan oleh pergerakan kerak bumi (lempeng bumi). Indonesia termasuk salah satu negara yang memiliki tingkat gempa yang cukup tinggi. Hal ini yang mendasari struktur rumah tinggal di Indonesia harus memiliki standar yang benar dengan menggunakan Standar Nasional Indonesia 2847-2013. Salah satu komponen struktur yang harus diwaspadai agar struktur tidak mudah runtuh adalah kolom. Hal ini yang menjadi dasar dilakukannya studi eksperimental tentang perkuatan kolom dengan penbinder dan FRP. Penelitian ini bertujuan untuk mengevaluasi kapasitas kolom persegi beton bertulang dengan menggunakan perkuatan pen-binder dan FRP. Benda uji dibuat sebanyak 6 kolom dengan ukuran penampang diameter 180mm dan tinggi 1000mm. Dengan rincian 2 kolom standar, 2 kolom dengan pen-binder, dan 2 kolom dengan FRP. Selain itu, 9 silinder dibuat untuk menguji kekuatan tekan dari kolom-kolom tersebut dan didapatkan f c = 20,75MPa. Hasil dari penelitian ini menunjukkan bahwa kolom dengan perkuatan FRP lebih baik dalam menerima beban siklik dibandingkan dengan kolom dengan perkuatan pen-binder dan kolom dengan standar. Kapasitas kolom dengan perkuatan FRP mencapai 1,166% lebih besar dari kolom standar. Kapasitas kolom dengan perkuatan pen-binder mencapai 1,118% lebih besar dari kolom standar. Kata Kunci: kolom, retak, standar, pen-binder, FRP, drift ratio. ix

EXPERIMENTAL STUDY OF CYCLIC LOADS TESTING CIRCULAR REINFORCED CONCRETE COLUMN USING PEN-BINDER AND FRP STRENGTHENING Ricky Candra Wijaya 1221008 Supervisor: Dr. Anang Kristianto, S.T., M.T. ABSTRACT Earthquake is a vibration or shock that occurs on the surface of the earth due to sudden release of energy from within that caused seismic waves. Earthquake can be caused by the movement of tectonic plates. Indonesia is one of the countries that have a high frequent of earthquake rate. This thing underlying the structure of the house in Indonesia must follow the correct standard by using the Indonesian National Standard 2847-2013. One of the structural components that should be aware of is column so that the structure does not easily collapse. These became the base of doing experimental study about reinforcing columns with pen-binder and FRP. The purpose of this research is to evaluate the capacity of the circular reinforced concrete column using pen-binder and FRP. The test object contains 6 columns with dimensions of 180mm diameter and 1000mm height. The details are 2 standard columns, 2 columns with pen-binder, and 2 columns with FRP. Moreover, 9 cylinders are made to test the compressive strength of columns and obtained f c = 20,75MPa. The results of this research indicating that columns with FRP are the best amongst columns with pen-binder and standard column when accepting cyclic loads. The capacity of column with FRP is 1,166% larger than standard column. The capacity of column with pen-binder is 1,118% larger than standard column. Keywords: columns, crack, standard, pen-binder, FRP, drift ratio. x

DAFTAR ISI HALAMAN JUDUL... i LEMBAR PENGESAHAN... ii PERNYATAAN ORISINALITAS LAPORAN PENELITIAN... iii PERNYATAAN PUBLIKASI LAPORAN PENELITIAN... iv SURAT KETERANGAN TUGAS AKHIR... v SURAT KETERANGAN SELESAI TUGAS AKHIR... vi KATA PENGANTAR... vii ABSTRAK... ix ABSTRACT... x DAFTAR ISI... xi DAFTAR GAMBAR... xiii DAFTAR TABEL... xv DAFTAR NOTASI... xvi DAFTAR LAMPIRAN... xviii BAB I PENDAHULUAN... 1 1.1 Latar Belakang... 1 1.2 Tujuan Penelitian... 2 1.3 Ruang Lingkup Penelitian... 2 1.4 Metode Penelitian... 2 1.5 Sistematika Penulisan... 3 BAB II TINJAUAN LITERATUR... 4 2.1 Struktur Beton Bertulang... 4 2.2 Material Pembentuk Beton... 6 2.2.1 Agregat... 6 2.2.2 Semen Portland... 10 2.2.3 Air... 11 2.2.4 Baja Tulangan... 11 2.3 Campuran Beton... 12 2.4 Daktilitas... 13 2.5 Kolom Beton Bertulang... 14 2.6 Penulangan Pada Kolom... 16 2.6.1 Tulangan Utama... 16 2.6.2 Tulangan Pengekang... 17 2.7 Kapasitas Kolom... 18 2.8 Keruntuhan Kolom... 18 2.9 Diagram Interaksi Kolom... 19 2.10 Pengujian Kuat Tekan Beton... 20 2.11 Perkuatan Kolom Beton Bertulang... 21 2.11.1 Perkuatan Kolom dengan Pen-Binder... 22 2.11.2 Perkuatan Kolom dengan Fiber Reinforced Polymer FRP... 23 2.12 Kurva Histeretik... 24 xi

BAB III METODE PENELITIAN... 28 3.1 Bagan Alir Penelitian... 28 3.2 Dimensi Benda Uji... 30 3.3 Pengujian Bahan Material Penyusun Beton Bertulang... 31 3.3.1 Agregat Halus... 31 3.3.2 Agregat Kasar... 32 3.3.3 Semen... 33 3.3.4 Baja Tulangan... 33 3.3.5 Perencanaan Campuran Beton... 34 3.3.6 Perencanaan Benda Uji... 34 3.3.6.1 Hasil Kuat Tekan Beton Silinder... 34 3.3.6.2 Penentuan Tulangan Utama dan Tulangan Pengekang... 35 3.3.7 Kapasitas Kolom Rencana... 36 3.4 Pelaksanaan Pembuatan Benda Uji... 38 3.4.1 Pembuatan Besi Tulangan... 38 3.4.2 Pembuatan Bekisting... 38 3.4.3 Pemasangan Strain Gauge... 39 3.4.4 Pengecoran Benda Uji... 43 3.4.5 Perawatan Benda Uji... 46 3.4.6 Pengecatan dan Penggarisan Benda Uji... 46 3.4.7 Pemasangan FRP... 47 3.5 Set-Up Alat Pengujian... 47 3.6 Proses Pengujian Benda Uji... 50 3.7 Deformasi Kolom Rencana... 51 BAB IV ANALISIS DATA... 52 4.1 Pola Retak Kolom... 52 4.1.1 Pola Retak Kolom Standar... 52 4.1.2 Pola Retak Kolom dengan Pen-Binder... 54 4.1.3 Pola Retak Kolom dengan FRP... 56 4.2 Hasil Pengujian Kolom... 58 4.2.1 Kolom Standar... 59 4.2.2 Kolom dengan Pen-Binder... 61 4.2.3 Kolom dengan FRP... 63 BAB V SIMPULAN DAN SARAN... 67 5.1 Simpulan... 67 5.2 Saran... 67 DAFTAR PUSTAKA... 68 LAMPIRAN... 70 xii

DAFTAR GAMBAR Gambar 2.1 Agregat Kasar... 7 Gambar 2.2 Agregat Halus... 8 Gambar 2.3 Semen... 11 Gambar 2.4 Baja Tulangan... 12 Gambar 2.5 Hubungan Regangan dan Tegangan... 13 Gambar 2.6 (a) Kolom Persegi; (b) Kolom Spiral; (c) dan (d)kolom Komposit... 15 Gambar 2.7 Diagram Interaksi Kolom... 20 Gambar 2.8 Kurva Histeretik Ideal... 25 Gambar 2.9 Model Kurva Histeretik Ramberg-Osgood... 25 Gambar 2.10 Model Kurva Histeretik Clough... 26 Gambar 2.11 Model Kurva Histeretik Isotropic Hardening... 26 Gambar 2.12 Model Kurva Histeretik Kinematic Hardening... 27 Gambar 2.13 Model Kurva Histeretik Combined Hardening... 27 Gambar 3.1 Diagram Alir Penelitian... 29 Gambar 3.2 (a) Benda Uji Silinder; (b) Benda Uji Kolom Standar; (c) Benda Uji Kolom dengan Pen-Binder; dan (d) Benda Uji Kolom dengan FRP... 30 Gambar 3.3 (a) Pengujian Berat Isi Agregat Halus; (b) Berat Jenis Kering dan Penyerapan Agregat Halus; (c) Pengujian Berat Jenis SSD Agregat Halus... 31 Gambar 3.4 (a) Pengujian Berat Isi Agregat Kasar; (b) Berat Jenis Kering, Berat Jenis SSD, dan Penyerapan Agregat Kasar... 32 Gambar 3.5 Pengujian Berat Jenis Semen... 33 Gambar 3.6 Hasil Uji Kuat Tarik... 33 Gambar 3.7 Diagram Interaksi Kolom... 37 Gambar 3.8 Beban dan Momen Lentur Pada Kolom... 37 Gambar 3.9 Pembuatan Besi Tulangan... 38 Gambar 3.10 Pembuatan Bekisting... 38 Gambar 3.11 Perataan Tulangan Ulir... 39 Gambar 3.12 Perataan Tulangan Polos... 40 Gambar 3.13 Pemasangan Strain Gauge di atas Lem Besi... 40 Gambar 3.14 Pemasangan Isolasi Bening di atas Strain Gauge... 41 Gambar 3.15 Pemasangan Isolasi Aspal... 41 Gambar 3.16 Pemasangan Isolasi Hitam... 42 Gambar 3.17 Pengikatan Strain Gauge... 42 Gambar 3.18 Strain Gauge Telah Dipasang... 42 Gambar 3.19 Pemasukkan Besi Tulangan dan Penyambungan Bekisting... 43 Gambar 3.20 Pengujian Slump... 44 Gambar 3.21 Pemasukkan Campuran Beton... 45 Gambar 3.22 Pembukaan Bekisting... 45 Gambar 3.23 Perbaikan Struktur Kolom... 46 Gambar 3.24 Perawatan Benda Uji... 46 Gambar 3.25 Pemasangan FRP... 47 xiii

Gambar 3.26 2D Set-Up Alat Pengujian... 48 Gambar 3.27 3D Set-Up Alat Pengujian... 49 Gambar 3.28 Set-Up Alat Pengujian... 49 Gambar 4.1 Pola Retak Kolom Standar 1: (a) Kolom Standar 1, (b) Tampak Depan, (c) Tampak Samping Kanan, (d) Tampak Belakang, (e) Tampak Samping Kiri... 52 Gambar 4.2 Pola Retak Kolom Standar 2: (a) Kolom Standar 2, (b) Tampak Depan, (c) Tampak Samping Kanan, (d) Tampak Belakang, (e) Tampak Samping Kiri... 53 Gambar 4.3 Pola Retak Kolom dengan Pen-Binder 1: (a) Kolom Penbinder 1, (b) Tampak Depan, (c) Tampak Samping Kanan, (d) Tampak Belakang, (e) Tampak Samping Kiri... 54 Gambar 4.4 Pola Retak Kolom dengan Pen-Binder 2: (a) Kolom Penbinder 2, (b) Tampak Depan, (c) Tampak Samping Kanan, (d) Tampak Belakang, (e) Tampak Samping Kiri... 55 Gambar 4.5 Pola Retak Kolom dengan FRP 1: (a) Kolom FRP 1, (b) Tampak Depan, (c) Tampak Samping Kanan, (d) Tampak Belakang, (e) Tampak Samping Kiri... 56 Gambar 4.6 Pola Retak Kolom dengan FRP 2: (a) Kolom FRP 2, (b) Tampak Depan, (c) Tampak Samping Kanan, (d) Tampak Belakang, (e) Tampak Samping Kiri... 57 Gambar 4.7 Kurva Histeretik Kolom Standar 1... 59 Gambar 4.8 Kurva Histeretik Kolom Standar 2... 60 Gambar 4.10 Kurva Histeretik Kolom dengan Pen-Binder 1... 61 Gambar 4.11 Kurva Histeretik Kolom dengan Pen-Binder 2... 62 Gambar 4.13 Kurva Histeretik Kolom dengan FRP 1... 63 Gambar 4.14 Kurva Histeretik Kolom dengan FRP 2... 64 xiv

DAFTAR TABEL Tabel 2.1 Klasifikasi Beton Berdasarkan Kuat Tekan... 4 Tabel 2.2 Jenis-jenis Tulangan... 12 Tabel 2.3 Angka Konversi Kekuatan Tekan Beton dengan Umur Beton... 21 Tabel 3.1 Data Pengujian Agregat Halus... 31 Tabel 3.2 Data Pengujian Agregat Kasar... 32 Tabel 3.3 Hasil Uji Kuat Tekan Beton Silinder... 35 Tabel 3.4 Drift Ratio dan Simpangan... 50 Tabel 4.1 Hasil Pengujian Kolom Standar 1... 59 Tabel 4.2 Hasil Pengujian Kolom Standar 2... 60 Tabel 4.3 Hasil Pengujian Kolom dengan Pen-Binder 1... 61 Tabel 4.4 Hasil Pengujian Kolom dengan Pen-Binder 2... 62 Tabel 4.5 Hasil Pengujian Kolom dengan FRP 1... 63 Tabel 4.6 Hasil Pengujian Kolom dengan FRP 2... 64 Tabel 4.7 Hasil Uji Beban Siklik pada Drift Ratio 3,5%... 65 Tabel 4.8 Hasil Uji Beban Siklik pada Drift Ratio 5,2%... 65 Tabel 4.9 Perubahan Hasil Uji Beban Siklik pada Drift Ratio 3,5% dan Drift Ratio 5,2%... 65 xv

DAFTAR NOTASI A Luas penampang A g Luas kotor penampang kolom A sd Luas tulangan baja tulangan yang digunakan A sv Luas tulangan pengekang A st Luas tulangan total yang digunakan A stmin Luas tulangan total minimum yang diperlukan b Lebar penampang melintang kolom B ba Berat agregat di dalam air b c Dimensi penampang inti kolom B j Berat benda uji kondisi ssd B j semen Berat jenis semen portland B j bulk hl Berat jenis kering agregat halus B j bulk ks Berat jenis kering agregat kasar B k Berat benda uji kondisi kering oven B p Berat piknometer diisi air B pj Berat piknometer + benda uji ssd + air c Jarak dari serat tekan terluar ke garis netral C c Sumbangan gaya tekan beton d Berat isi air pada temperatur ruang yang tetap, D a Bobot isi agregat e Perbandingan antara momen nominal penampang dan kuat tekan aksial normal e b Perbandingan antara momen nominal penampang dan kuat tekan aksial nominal pada kondisi regangan seimbang E Modulus elastisitas E s Modulus elastis baja F Besar gaya tekan f c Kuat tekan beton karakteristik f cc Kuat tekan beton terkekang f co Kuat tekan beton tidak terkekang f co rata-rata Kuat tekan beton terkekang aktual rata rata f si Tegangan pada setiap baris tulangan F si Sumbangan gaya masing masing baris tulangan f y Tegangan leleh tulangan f 1 Tegangan leleh tulangan pengekang f 1e Tegangan lateral ekuivalen h Tinggi penampang melintang kolom h c Lebar inti beton k 1 Koefisien yang menyatakan hubungan antara tegangan pengekang dan peningkatan kekuatan k 2 Koefisien yang menyatakan efisiensi tulangan pengekang L Panjang awal M n Kekuatan momen nominal penampang Kekuatan momen nominal penampang pada kondisi seimbang M nb xvi

n Jumlah tulangan P Tekanan Pc Kuat beban aksial akibat kontribusi beton Pst Kuat beban aksial akibat kontribusi baja P o Kuat beban aksial nominal akibat beban aksial konsentrik P o rata-rata Kuat beban aksial aktual rata rata P n Kuat beban aksial maksimum yang telah direduksi P nb Kuat beban aksial nominal pada kondisi regangan seimbang s Jarak tulangan pengekang sepanjang tinggi kolom S x Jarak spasi antar tulangan sengkang s 1 Jarak pusat antar tulangan utama t Tinggi benda uji V Volume cawan silinder V 1 Volume awal semen Portland V 2 Volume akhir semen Portland W Berat benda uji semen Portland Wa Berat agregat Z Suatu nilai sembarang untuk membuat diagram interaksi ɸ Koefisien reduksi ɸP n(max) Kuat tekan rencana maksimum yang telah direduksi β 1 Rasio tinggi tekan ekivalen,a ke jarak garis netral, c. Ɛ Regangan Ɛ cu Batas regangan beton Ɛ si Regangan pada setiap baris tulangan Ɛ y Regangan leleh baja ρ s Rasio tulangan σ Tegangan ΔL Pertambahan panjang xvii

DAFTAR LAMPIRAN Lampiran L.1 Pengujian Bahan Material... 70 Lampiran L.2 Perancangan Campuran Beton... 76 Lampiran L.3 Proses Pengerjaan Benda Uji... 82 Lampiran L.4 Hasil Uji Kolom... 94 xviii