PENERAPAN KOEFISIEN KOREKSI ELEMEN KARTU THERMOLUMINISENCE (TLD) UNTUK PERHITUNGAN DOSIS EKSTERNA

dokumen-dokumen yang mirip
ESTIMASI KETIDAKPASTIAN PENGUKURAN DOSIS PERORANGAN MENGGUNAKAN THERMOLUMINISENCE DOSIMETER (TLD)

EVALUASI DOSIS RADIASI EKSTERNAL PEKERJA PUSAT RADIOISOTOP DAN RADIOFARMAKA ( PRR )

EVALUASI DOSIS RADIASI EKSTERNAL PEKERJA PUSAT RADIOISOTOP DAN RADIOFARMAKA ( PRR )

PENGUKURAN DOSIMETER PERORANGAN PEKERJA RADIASI PUSAT REAKTOR SERBA GUNA TAHUN Yanni Andriani, Elfida Pusat Teknologi Limbah Radioaktif-BATAN

PENGENDALIAN PERSONEL DI PUSAT PENELITIAN TENAGA NUKLIR SERPONG TAHUN 2005

ANALISIS DOSIS RADIASI PEKERJA RADIASI IEBE BERDASARKAN KETENTUAN ICRP 60/1990 DAN PP NO.33/2007

OPTIMASI ALAT CACAH WBC ACCUSCAN-II UNTUK PENCACAHAN CONTOH URIN

MONITORING DOSIS DAN KESEHATAN PEKERJA PPTN SERPONG TAHUN 2006

PEMANTAUAN DOSIS RADIASI INTERNAL DENGAN WBC UNTUK PEKERJA PUSAT TEKNOLOGI LIMBAH RADIOAKTIF SERPONG TAHUN 2012

PEMANTAUAN DOSIS PERORANGAN DI PUSAT TEKNOLOGI NUKLIR BAHAN DAN RADIOMETRI - BATAN BANDUNG

BAB V Ketentuan Proteksi Radiasi

TANGGAPAN TLD-600 TERHADAP DOSIS NEUTRON CEP AT YANG DITERIMA SECARA TERUS-MENERUS DAN TERPUTUS-PUTUS

KAJIAN KESELAMATAN PADA PROSES PRODUKSI ELEMEN BAKAR NUKLIR UNTUK REAKTOR RISET

PRARANCANGAN PEMANTAUAN RADIASI DAN KONTAMINASI UDARA DI RUANG KERJA KOMPAKSI DI IPLR

Analisis Persamaan Respon Dosis Thermoluminescent Dosimeter (TLD) Pada Spektrum Sinar-X Menggunakan Metode Monte Carlo

PENINGKATAN SISTEM PROTEKSI RADIASI DAN KESELAMATAN KAWASAN NUKLIR SERPONG TAHUN 2009

Analisis Pengaruh Sudut Penyinaran terhadap Dosis Permukaan Fantom Berkas Radiasi Gamma Co-60 pada Pesawat Radioterapi

EVALUASI KESELAMATAN RADIASI PENGUNJUNG DI TEMPAT PENYIMPANAN SEMENTARA LIMBAH RADIOAKTIF

BERITA NEGARA REPUBLIK INDONESIA

DOSIMETER CAS04:DY BUATAN BARC SEBAGAI PEMANTAU DOSIS RADIASI PERORANGAN HP (10) Rofiq Syaifudin, Nina Herlina, dan Bambang Supriyanto PTKMR - BAT AN

INTERKOMPARASI PENGUKURAN KAPSUL DALAM Ir-192 UNTUK UJI TAK MERUSAK

EVALUASI DOSIS RADIASI INTERNAL PEKERJA RADIASI PT-BATAN TEKNOLOGI DENGAN METODE IN-VITRO

Widyanuklida, Vol. 15 No. 1, November 2015: ISSN

PRARANCANGAN SISTEM PEMANTAUAN DOSIS EKSTERNAL PERORANGAN PEKERJA RADIASI PLTN

TANGGAPAN THERMOLUMINESCENT DOSIMETER CaSO 4 :Dy TERHADAP MEDAN RADIASI CAMPURAN BETA, GAMMA DAN MEDAN RADIASI CAMPURAN BETA GAMMA

KALIBRASI EFISIENSI α/β COUNTER UNTUK ANALISIS RADIONUKLIDA PEMANCAR BETA DALAM CONTOH URIN

ANALISIS KESELAMATAN RADIASI PENYIMPANAN LIMBAH RADIOAKTIF DI INTERIM STORAGE-1 SELAMA PERIODE

KOMPARASI HASIL PENGUKURAN WBC ACCUSCAN II DENGAN WBC TIPE BED

Hasil Penelitian dan Kegiatan PTLR Tahun 2012 ISSN PENGUKURAN DOSIS RADIASI LATAR DI BANGKA SELATAN

ASPEK KESELAMATAN PADA PENGANGKUTAN BAHAN NUKLIR DENGAN KENDARAAN DARAT

OPERASIONAL SISTEM PEMANTAUAN RADIASI SECARA REALTIME DI DAERAH KERJA INSTALASI PENGOLAHAN LIMBAH RADIOAKTIF

PENENTUAN CALIBRATOR SETTING CAPINTEC CRC-7BT UNTUK SAMARIUM-153

PENGUKURAN DOSIS RADIASI RUANGAN RADIOLOGI II RUMAH SAKIT GIGI DAN MULUT (RSGM) BAITURRAHMAH PADANG MENGGUNAKAN SURVEYMETER UNFORS-XI

TINJAUAN DOSIS RADIASI EKSTERNAL TERHADAP PEKERJA DALAM PERBAIKAN DETEKTOR NEUTRON JKT03 CX 821 DI RSG-GAS

BAB IV Alat Ukur Radiasi

TEORI DASAR RADIOTERAPI

Hasil Penelitian dan Kegiatan PTLR Tahun 2012 ISSN

LAYANAN PEMANTAUAN DOSIS TARA PERORANGAN EKSTERNAL DI LABORATORIUM KESELAMATAN, KESEHATAN, DAN LINGKUNGAN PTKMR BATAN *)

PENGUKURAN LAJU DOSIS PAPARAN RADIASI EKSTERNAL DI AREA RADIOTERAPI RSUD DR. SAIFUL ANWAR MALANG. Diterima: 6 Juni 2016 Layak Terbit: 25 Juli 2016

PREDIKSI DOSIS PEMBATAS UNTUK PEKERJA RADIASI DI INSTALASI ELEMEN BAKAR EKSPERIMENTAL

EVALUASI PENGENDALIAN KESELAMATAN RADIASI DAN NON RADIASI DALAM PENGOLAHAN LIMBAH RADIOAKTIF TAHUN

EVALUASI PENGENDALIAN KESELAMATAN RADIASI DAN NON RADIASI DALAM PENGOLAHAN LIMBAH RADIOAKTIF TAHUN

INTERKOMPARASI PENGUKURAN OUTPUT IRADIATOR 137 Cs DAN PERSONAL DOSE EQUIVALENT, Hp(10) MENGGUNAKAN TLD DAN FILM

KAJIAN DETEKTOR AKTIVASI NEUTRON CEPAT UNTUK PENGGUNAAN DETEKTOR NEUTRON

PENGUKURAN DAN EVALUASI KESELAMATAN TERHADAP BAHAYA RADIASI EKSTERNA DI PTAPB-BATAN YOGYAKARTA

Jurnal Fisika Unand Vol. 3, No. 4, Oktober 2014 ISSN

OPTIMASI PENGUKURAN KEAKTIVAN RADIOISOTOP Cs-137 MENGGUNAKAN SPEKTROMETER GAMMA

PENELITIAN DAN NUKLIR ABSTRAK PEKERJA BKTPB 1,27. msv. BEM. merupakan. tahun. ABSTRACTT. for radiation. carried out. on radiation.

Verifikasi Keluaran Radiasi Pesawat Linac (Foton Dan Elektron) Serta 60CO Dengan TLD

PEMANTAUAN PAPARAN RADIASI LINGKUNGAN DI PUSAT PENGEMBANGAN GEOLOGI NUKLIR TAHUN 2011

PENGAWASAN PEMBUATAN DI PUSA T RADIOISOTOP DAN RADIOFARMAKA

RANCANGAN PERATURAN KEPALA BADAN PENGAWAS TENAGA NUKLIR TENTANG LABORATORIUM DOSIMETRI EKSTERNA

KEPALA BADAN PENGAWAS TENAGA NUKLIR REPUBLIK INDONESIA

KOMPARASI PERHITUNGAN DOSIS RADIASI INTERNA PEKERJA PPTN SERPONG BERDASARKAN ICRP 30 TERHADAP ICRP 68

KEPALA BADAN PENGAWAS TENAGA NUKLIR REPUBLIK INDONESIA

Verifikasi Dosis Radiasi Kanker Menggunakan TLD-100 pada Pasien Kanker Payudara dengan Penyinaran Open System

PEMANTAUAN PENERIMAAN DOSIS EKSTERNA DAN INTERNA DI INSTALASI RADIOMETALURGI TAHUN 2012

Pengukuran Dosis Radiasi dan Estimasi Efek Biologis yang Diterima Pasien Radiografi Gigi Anak Menggunakan TLD-100 pada Titik Pengukuran Mata dan Timus

2015, No Radioaktif (Lembaran Negara Republik Indonesia Tahun 2007 Nomor 74, Tambahan Lembaran Negara Republik Indonesia Nomor 4370); 4. Perat

UJI BANDING SISTEM SPEKTROMETER GAMMA DENGAN METODA ANALISIS SUMBER Eu-152. Nugraha Luhur, Kadarusmanto, Subiharto

KAJIAN ASPEK KESELAMATAN DALAM PENANGANAN PENERIMAAN DOSIS RADIASI EKSTERNA BERLEBIH DI PRR

PERBANDINGAN METODA OTOMATIS DAN MANUAL DALAM PENENTUAN ISOTOP Cs-137 MENGGUNAKAN SPEKTROMETER GAMMA

FAKTOR KOREKSI PENGUKURAN AKTIVITAS RADIOFARMAKA I-131 PADA WADAH VIAL GELAS TERHADAP AMPUL STANDAR PTKMR-BATAN MENGGUNAKAN DOSE CALIBRATOR

ANALISIS WAKTU PELURUHAN TERHADAP PERSYARATAN DOSIS RADIOISOTOP UNTUK PEMERIKSAAN GONDOK

BERITA NEGARA REPUBLIK INDONESIA

Analisis Dosis Keluaran Radiasi Dengan Sumber Cs-137 Pada Proses Kalibrasi Pendosimeter. Muhijrah 1,Wira Bahari Nurdin, Bannu Abdul

AUDIT MUTU PENGUKURAN DOSIS SERAP DARI SUMBER TELETERAPI Co-60 CIRUS 90131

UJI KESESUAIAN PESAWAT CT-SCAN MEREK PHILIPS BRILIANCE 6 DENGAN PERATURAN KEPALA BAPETEN NOMOR 9 TAHUN 2011

PERATURAN KEPALA BADAN PENGAWAS TENAGA NUKLIR NOMOR 4 TAHUN 2013 TENTANG PROTEKSI DAN KESELAMATAN RADIASI DALAM PEMANFAATAN TENAGA NUKLIR

KAJIAN PENERIMAAN OOSIS RADlASI EKSTERNA PEKERJA RADlASI PRSG-BATAN SERPONG. Sunarningsih, Mashudi, A.Lilik W, Yosep S.

PENGEMBANGAN PENGENDALIAN PROTEKSI RADIASI DAERAH KERJA, PERSONIL DAN LINGKUNGAN DI PTLR

BAB I PENDAHULUAN. Perkembangan ilmu dan teknologi nuklir yang pesat di zaman sekarang ini

PENGUNGKUNGAN SUMBER 85 Kr, 133 Xe, 198 Au, DAN 24 Na PASCA IRADIASI

TANGGAPAN TLD-600 TERHADAP DOSIS NEUTRON CEPAT YANG DITERIMA SECARA TERUS-MENERUS DAN TERPUTUS-PUTUS

bahwa semakin besar jarak ukur maka dosis serap yang diterima semakin kecil. Kata kunci :Kalibrasi, survei meter, dosis serap, faktor kalibrasi

PENGENDALIAN DAERAH KERJA PAPARAN RADIASI GAMMA DI RSG GAS

PERATURAN KEPALA BADAN PENGAWAS TENAGA NUKLIR NOMOR 11 TAHUN 2015 TENTANG LABORATORIUM DOSIMETRI EKSTERNA DENGAN RAHMAT TUHAN YANG MAHA ESA

ANALISIS DOSIS YANG DITERIMA PASIEN PADA PEMERIKSAAN RENOGRAF

EVALUASI FLUKS NEUTRON THERMAL DAN EPITHERMAL DI FASILITAS SISTEM RABBIT RSG GAS TERAS 89. Elisabeth Ratnawati, Jaka Iman, Hanapi Ali

Alat Proteksi Radiasi

PENGUKURAN DOSIS PAPARAN RADIASI DI AREA RUANG CT SCAN DAN FLUOROSKOPI RSUD DR. SAIFUL ANWAR MALANG. Novita Rosyida

SISTEM MANAJEMEN KESELAMATAN RADIASI

Paparan radiasi dari pekerja radiasi sejak tahun berdasarkan kriteria dan lama kerja

PERATURAN KEPALA BADAN PENGAWAS TENAGA NUKLIR TENTANG KESELAMATAN RADIASI DALAM PENGGUNAAN IRADIATOR DENGAN RAHMAT TUHAN YANG MAHA ESA

ABSTRAK. Kata Kunci: perhitungan radiasi, proteksi radiasi

FORMULIR PERMOHONAN IZIN PEMANFAATAN SUMBER RADIASI PENGION UNTUK KEGIATAN : PERUNUT

X. ADMILNISTRASI. 1. Konsep satuan-satuan radiasi. Besaran-besaran radiologis yang banyak digunakan dalam proteksi radiasi adalah :

ANALISIS DOSIS PEMBATAS UNTUK PEKERJA RADIASI DI INSTALASI RADIOMETALURGI.

EVALUASI PAPARAN RADIASI TERHADAP DOSIS EKSTERNA YANG DITERIMA PEKERJA RADIASI DI IEBE TAHUN 2008

KEPALA BADAN PENGAWAS TENAGA NUKLIR REPUBLIK INDONESIA

PENENTUAN AKTIVITAS SUMBER RADIOAKTIF PEMANCAR GAMMA Eu-152 DI LABORATORIUM PTNBR

FORMULIR PERMOHONAN IZIN PEMANFAATAN SUMBER RADIASI PENGION UNTUK KEGIATAN GAUGING INDUSTRI

Realisasi Sistem Pemantau Kepadatan Lalu-Lintas Menggunakan Teknologi Radar RTMS G4

Verifikasi Ketepatan Hasil Perencanaan Nilai Dosis Radiasi Terhadap Penerimaan Dosis Radiasi Pada Pasien Kanker

PEMANTAUAN LINGKUNGAN DI SEKITAR PUSAT PENELITIAN TENAGA NUKLIR SERPONG DALAM RADIUS 5 KM TAHUN 2005

PENJELASAN ATAS PERATURAN PEMERINTAH REPUBLIK INDONESIA NOMOR 63 TAHUN 2000 TENTANG KESELAMATAN DAN KESEHATAN TERHADAP PEMANFAATAN RADIASI PENGION

PERATURAN KEPALA BADAN PENGAWAS TENAGA NUKLIR FORMULIR PERMOHONAN SURAT IZIN BEKERJA PETUGAS TERTENTU

BAB 2 TINJAUAN PUSTAKA

BAB I PENDAHULUAN. I.1. Latar Belakang

PEMANTAUAN RADIOAKTIVITAS LINGKUNGAN DI SEKITAR KAWASAN NUKLIR SERPONG TAHUN 2012

Transkripsi:

PENERAPAN KOEFISIEN KOREKSI ELEMEN KARTU THERMOLUMINISENCE (TLD) UNTUK PERHITUNGAN DOSIS EKSTERNA L. Kwin Pudjiastuti, Sri Widayati, Elfida Pusat Teknologi Limbah Radioaktif ABSTRAK PENERAPAN KOEFISIEN KOREKSI ELEMEN KARTU TLD UNTUK PERHITUNGAN DOSIS EKSTERNA. Untuk memperoleh hasil perhitungan dosis yang teliti dan benar-benar merupakan dosis yang diterima pekerja, diperlukan faktor kalibrasi. Koefisien koreksi elemen (ECC) dalam perhitungan dosis diterapkan sebagai faktor kalibrasi awal, disamping faktor kalibrasi dari alat TLD reader atau Reader Calibration Factor (RCF) yang sesuai dengan jenis kartu TLD. Faktor kalibrasi alat diperoleh dengan melakukan penyinaran kartu TLD standar dengan sumber standar pemancar gamma pada dosis tertentu di Fasilitas Kalibrasi Tingkat Nasional di PTKMR, kemudian dilakukan pembacaan dengan alat TLD reader, sehingga diperoleh RCF. Dosis radiasi diperoleh dari hasil bacaan yang telah dikoreksi dengan ECC dikurangi dengan hasil bacaan blanko yang telah dikoreksi dengan ECC kartu TLD tersebut kemudian dibagi dengan RCF. Hasil kegiatan ini diperoleh besaran ECC dalam satu grup mendekati angka 1 (satu), berarti kartu TLD yang digunakan dalam kondisi baik, sedangkan faktor kalibrasi alat tidak jauh berbeda dengan faktor kalibrasi yang pernah dilakukan. ABSTRACT IMPLEMENTATION OF TLD ELEMENT CORECTION COEFISIENT CARD FOR EXTERNAL DOSE CALCULATION. To obtain an accurate and real occupational dose calculation, calibration factor is needed. Element Correction Coefisien (ECC) in dose calculation, is applied as the first calibration factor, besides the calibration factor of the TLD reader (RCF) which is appropriate with the type of TLD. Reader Calibration Factor was obtained by irradiating the TLD card standard with a known gamma standard source to some certain doses at National Calibration Fasility in PTKMR. The TLD standard was then read by using a TLD reader to get an RCF. Radiation dose of TLD obtained from the ECC corrected result minus ECC corrected background of that TLD and divided by RCF. The result of this activity indicated that ECC is a group of TLD is cluse to 1 (one), which means that the TLD being used is good condition and the calibration factor of the reader isn t defferen so far with the same as before. PENDAHULUAN Peraturan Pemerintah No 63 tahun 2000 tentang Keselamatan dan Kesehatan terhadap Pemanfaatan Radiasi Pengion menyatakan bahwa pemrosesan dosis perorangan dilakukan oleh laboratorium yang terakreditasi atau ditunjuk. [1] Dalam hal ini maka diperlukan suatu perhitungan dosis radiasi yang diterima pekerja yang teliti dan dapat dipertanggungjawabkan kebenarannya.

Untuk memenuhi persyaratan tersebut secara bertahap telah dilakukan penelitian dan pengembangan dalam pemrosesan dosimeter perorangan sehingga hasil yang diperoleh semakin mendekati kebenaran. Dalam perhitungan dosis diperlukan faktor koreksi untuk memperkecil atau bahkan menghilangkan beberapa faktor penyebab terjadinya kesalahan perhitungan, diantaranya adalah faktor koreksi koefisien (ECC) dan faktor kalibrasi alat pembaca TLD /reader (RCF). Kedua faktor koreksi ini sangat diperlukan dalam penerapan perhitungan dosis radiasi yang diterima pekerja, sehingga dosis yang diterima pekerja adalah benar-benar merupakan dosis radiasi yang diterimanya selama bekerja di medan radiasi. Koefisien koreksi elemen (ECC) diperlukan sebagai koreksi efisiensi thermolunimisence, Intensitas luminisence yang dipancarkan oleh setiap satuan dosis yang diserap kartu TLD memiliki bermacam-macam efisiensi thermoluminisence dengan rentang antara 10 sampai dengan 15 %, dengan menggunakan ECC maka rentang ini dapat diperkecil menjadi sepersepuluhnya.(2) BAHAN DAN METODE Bahan : - Kartu TLD standar dengan berbagai jenis, - Gas nitrogen - Alat tulis kantor. Metodologi : Sebelum melakukan kegiatan terlebih dahulu melakukan pengecekan alat untuk memastikan dapat dioperasikan dengan baik, serta penyediaan nitrogen gas yang sesuai dengan spesifikasi yang diperlukan oleh alat. Urutan prosedur adalah annealing kartu TLD, irradiasi secara internal yaitu penyinaran dengan menggunakan sumber radiasi yang terintegrasi didalam alat pembaca TLD, hal ini dilakukan untuk memperoleh harga ECC dari masing-masing elemen kartu TLD standar. Koefisien koreksi elemen i pada kartu j (ECCij) diperoleh dengan melakukan iradiasi secara internal dan respon masing-masing elemen kartu TLD (TLEij) dihitung terhadap respon rata-rata dalam satu kelompok atau [TLE] ditunjukkan dengan persamaan sebagai berikut : (2). Secara teori ECCij = [TLE] / TLEij..... (1) 358

Sedangkan iradiasi secara eksternal dilakukan melalui penyinaran dengan sumber standar yang ada di fasilitas kalibrasi tingkat nasional. Evaluasi hasil pembacaan kartu TLD ini akan diperoleh hasil faktor kalibrasi alat TLD reader untuk berbagai jenis kartu TLD atau biasa disebut Reader Calibration Factor (RCF). Faktor kalibrasi ini merupakan faktor hasil bagi besaran dosis iradiasi dengan besaran dosis hasil pembacaan dengan alat TLD Reader. Sebagai kegiatan terakhir adalah pembacaan hasil iradiasi dengan alat TLD reader model 6600 dan evaluasi data. Semua kegiatan ini dilaksanakan secara bertahap dengan mengacu pada instruksi kerja tentang annealing dan kalibrasi, pengoperasian alat TLD Reader maupun evaluasinya yang terkendali di sub bidang pengendalian personil. (3) Dari hasil pembacaan kartu TLD yang digunakan pekerja, maka dapat dihitung dosis radiasi yang diterima oleh pekerja yang bersangkutan dengan melalui berbagai faktor koreksi. Tahapan perhitungan dosis untuk memperoleh hasil akhir dosis yang diterima pekerja meliputi hasil perkalian antara pembacaan dosis menggunakan alat TLD Reader dengan harga ECC dari masing-masing elemen kartu TLD yang bersangkutan. Tahap kemudian adalah melakukan pembagian dengan harga RCF dengan jenis dan posisi elemen kartu TLD yang sejenis, untuk selanjutnya dilakukan pengurangan dengan nilai bacaan latar/ background daerah pemakai. Adapun persamaan tersebut adalah : Bacaan ( nc ) xecc Blanko ( nc ) xecc Dosis = ( msv ) 2 RCF ( nc / msv ) RCF ( nc / msv ) Persamaan 2 diatas dapat disederhanakan menjadi : Dosis = ( BacaanxECC bacaan ) ( blankoxecc RCF blanko ) msv.. 3 359

HASIL DAN PEMBAHASAN Hasil kegiatan ini diperoleh data besaran koefisien koreksi elemen rata-rata pada 10 kartu TLD standar dengan mengambil nilai batas atas dan batas bawah sebesar 0,85 dan 1,15 untuk berbagai jenis kartu TLD ditampilkan pada Tabel 1. Tabel 1. Koefisien koreksi elemen (ECC) kartu TLD standar pada berbagai jenis kartu. NO JENIS TLD ECC RATA-RATA KARTU TLD POSISI 1 POSISI 2 POSISI 3 POSISI 4 1. TLD- 0110-1.0013 1.0015-2. TLD-7001 1.0005 - - 0.9990 3. TLD-7767 1.0087 - - 1.0073 4. TLD-7776 1.0025 - - 0.9905 5. TLD-0220-1.0348 1.0019 - Harga ECC dari elemen kartu TLD tersebut pada Tabel 1. menunjukkan bahwa kartu TLD tersebut masih sangat baik dengan harga faktor kalibrasi rata-rata masing-masing elemen mendekati 1 (satu). Berarti dalam satu populasi kartu TLD memiliki harga ECC yang hampir sama. Tanpa perlakuan penentuan ECC kartu TLD standar, maka tidak dapat diperoleh harga RCF. Reader Calibration Factor (RCF) hasil perhitungan untuk berbagai jenis kartu TLD ditampilkan dalam Tabel 2. sebagai berikut : Tabel 2. Nilai RCF kartu TLD standar pada berbagai jenis kartu. RCF KARTU TLD (nc/mrem) NO JENIS TLD POSISI 1 POSISI 2 POSISI 3 POSISI 4 1. TLD- 0110-0.3197 0.1468-2. TLD-7001 0.28803 - - 0.4886 3. TLD-7767 0.2854 - - 0.2540 4. TLD-7776-0.3455 0.1758-5. TLD-0220-6.2970 5.572 - Tabel 2. menunjukkan besaran RCF yaitu faktor kalibrasi dari alat terhadap hasil pembacaan dosis pada masing-masing elemen kartu TLD yang sejenis. Faktor kalibrasi ini dapat dilakukan pengulangan setiap tahun untuk melakukan pengecekan ketelitian dari unjuk kerja alat TLD reader. 360

Untuk kartu TLD -7001 dan TLD-7767 posisi 4 merupakan elemen yang menyerap radiasi pemancar gamma sedangkan posisi 1 adalah elemen yang menyerap radiasi pemancar beta dan gamma. Kartu TLD-0110 dan TLD-7776 dengan posisi elemen 2 merupakan elemen yang menyerap radiasi pemancar gamma sedangkan elemen 3 menyerap radiasi pemancar beta dan gamma. Dari uraian diatas maka elemen yang menyerap radiasi pemancar beta dan gamma memiliki harga RCF lebih kecil dari pada elemen yang menyerap radiasi pemancar gamma saja. Kartu TLD-0220 memiliki harga RCF relatif lebih tinggi dari pada yang lainnya karena TLD jenis ini merupakan TLD untuk lingkungan yang lebih sensitif terhadap pemancar radiasi dari alam maupun sinar kosmik. Kartu TLD jenis TLD-7767 posisi 3 dan 4 tidak dilakukan penentuan harga RCF karena posisi ini untuk menyerap neutron dan campuran neutron dan gamma, sedangkan sumber standar di Fasilitas kalibrasi sampai saat ini belum bisa melayani penyinaran untuk neutron, demikian halnya dengan jenis TLD-7776 posisi 1 dan 4. Penerapan hasil perhitungan ECC pada kartu TLD yang dipergunakan pekerja ditampilkan dalam Tabel 3. sebagai berikut. Tabel 3. Hasil perhitungan dosis kartu TLD pekerja dengan jenis 0110 No ID card Hasil bacaan (nc) ECC Dosis (msv) Pos. 2 Pos. 3 Pos. 2 Pos. 3 Hp(0,07) Hp(10) 1 1507 5.8159 3.9520 1.024 1.996 0.016 0.004 2 322 5.6524 3.7594 1.075 1.019 0.019 0.003 3 275 5.7665 3.6714 1.091 1.053 0.026 0.003 4 1601 5.6174 3.6070 1.045 1.068 0.013 0.003 5 132 6.5845 3.8997 1.010 1.084 0.038 0.006 6 466 5.9628 3.7287 1.050 1.032 0.025 0.003 7 445 5..5972 3.4899 1.053 1.055 0.014 0.001 8 1551 5.5779 3.5366 1.075 1.058 0.017 0.002 9 60 6.5817 3.8040 1.043 1.028 0.035 0.003 10 154 5.7943 3.5529 1.077 1.028 0.025 0.0007 Tabel 3. menampilkan hasil pembacaan kartu TLD yang dipergunakan pekerja serta hasil perhitungan ECC dan dosisnya. Dengan mempergunakan faktor kalibrasi secara bertingkat maka perhitungan dosis yang dihasilkan lebih teliti, 361

dengan pemaparan selama tiga bulan diperoleh dosis yang relatif kecil dan dapat dikatakan tidak terdeteksi atau dibawah deteksi. KESIMPULAN Dari data hasil kegiatan diatas dapat disimpulkan bahwa adanya ECC serta faktor koreksi alat akan memperkecil adanya kesalahan-kesalahan sehingga dipastikan dosis hasil perhitungan benar-benar merupakan dosis yang diterima oleh pekerja radiasi yang bersangkutan. Data hasil perhitungan ECC dapat tersimpan dalam database sistem WinREMS, sehingga untuk perhitungan selanjutnya dengan kartu TLD dan nomor ID yang sama, dalam pembacaan TLD, maka secara otomatis data ECC akan digunakan dalam perhitungan dosis akhir. Penentuan ECC relatif memakan waktu yang lama karena setiap elemen dari setiap kartu dilakukan penentuan ECC, namun dapat dipergunakan untuk seterusnya dan dapat ditinjau ulang setelah 5 (lima) tahun. DAFTAR PUSTAKA 1. PP No. 63 Tahun 2000 tentang Keselamatan dan Kesehatan terhadap Pemanfaatan Radiasi Pengion. Jakarta, 2000. 2. SAINT GOBAIN ; Model 6600 Automated TLD Reader with WinREMS, Operation s manual, Saint Gobain crystals & Detectors Radiation Measurement Products, 6801 Cochram Road, Solon, Ohio 44139, USA. Release Date Juni 26,2002. 3. P2PLR : Instruksi Kerja Pengoperasian TLD Reader Model 6600 dengan WinREMS. Laboratorium Pemantauan Dossi Perorangan P2PLR, Serpong, 2005 4. P.CRISTENSEN and R.V.GRAFFITH; Required Accuracy and Dose Thresholds in Individual Monitoring, Radiation Protection Dosimetry, Nuclear Technology Publishing, 1994. 362