ANALISIS PERPINDAHAN PANAS PADA COOLER TANK FASSIP - 01

dokumen-dokumen yang mirip
Analisis Perpindahan Panas Pada Cooler Tank FASSIP - 01

ABSTRAK ABSTRACT KATA PENGANTAR

Analisa Perpindahan Panas Pada Heater Tank FASSIP - 01

Fakultas Teknik Universitas Ibn Khaldun Bogor Jl. KH. Soleh Iskandar KM.2 Bogor 16162

KARAKTERISTIKA PERPINDAHAN PANAS TABUNG COOLER PADA FASILITAS SIMULASI SISTEM PASIF MENGGUNAKAN ANSYS

Fenomena Transport Heat Exchanger Sistem Untai

BAB I PENDAHULUAN Latar Belakang

PEMODELAN SISTEM KONVERSI ENERGI RGTT200K UNTUK MEMPEROLEH KINERJA YANG OPTIMUM ABSTRAK

EKSPERIMEN AWAL ALIRAN SIRKULASI ALAMIAH PADA SIMULASI SISTEM KESELAMATAN PASIF

ANALISIS LAJU ALIRAN AIR DI COOLER PADA HEAT SINK SYSTEM UNTAI UJI FASSIP

ANALISIS UNJUK KERJA PEMANAS DAN PENDINGIN DI UNTAI FASILITAS SIMULASI SISTEM PASIF

EFEKTIFITAS PERPINDAHAN PANAS PADA DOUBLE PIPE HEAT EXCHANGER DENGAN GROOVE. Putu Wijaya Sunu*, Daud Simon Anakottapary dan Wayan G.

LAPORAN PENELITIAN HIBAH BERSAING

RISET KECELAKAAN KEHILANGAN AIR PENDINGIN: KARAKTERISTIK TERMOHIDRAULIK

ANALISA PENGARUH VARIASI LAJU ALIRAN UDARA TERHADAP EFEKTIVITAS HEAT EXCHANGER MEMANFAATKAN ENERGI PANAS LPG

EFEK PERUBAHAN KETINGGIAN COOLER TERHADAP KECEPATAN ALIRAN AIR PADA SIMULASI SISTEM PASIF

BAB I PENDAHULUAN I. 1. Latar Belakang

PERHITUNGAN LAJU ALIR PENDINGIN AIR SISI PRIMER PADA UNTAI UJI BETA UNTUK EKSPERIMEN SISTEM PASIF

Bab 1. PENDAHULUAN Latar Belakang

JURUSAN TEKNIK MESIN FAKULTAS TEKNIK UNIVERSITAS SEBELAS MARET SURAKARTA

DISTRIBUSI TEMPERATUR SAAT PEMANASAN DAN PENDINGINAN PER- MUKAAN SEMI-SPHERE HeaTING-03 BERDASARKAN TEMPERATUR AWAL

SKRIPSI PENGARUH SUDUT PELETAKAN PIPA KALOR BERTINGKAT TERHADAP KINERJA PIPA KALOR DALAM SISTEM PENDINGINAN CPU (CENTRAL PROCESSING UNIT) Oleh :

OPTIMASI KINERJA IHX UNTUK SISTEM KOGENERASI RGTT200K

ANALISIS VISUAL PENDINGINAN ALIRAN DUA FASA MENGGUNAKAN KAMERA KECEPATAN TINGGI ABSTRAK ABSTRACT

PERFORMANCE ANALYSIS OF FLAT PLATE SOLAR COLLECTOR WITH ADDITION OF DIFFERENT DIAMETER PERFORATED FINS ARE COMPILED BY STAGGERED

ANALISIS EFEKTIFITAS ALAT PENUKAR KALOR SHELL & TUBE DENGAN MEDIUM AIR SEBAGAI FLUIDA PANAS DAN METHANOL SEBAGAI FLUIDA DINGIN

PENGUJIAN KOLEKTOR SURYA PLAT DATAR UNTUK PEMANAS AIR LAUT DENGAN MEMBANDINGKAN PERFORMANSI KACA SATU DENGAN KACA BERLAPIS KETEBALAN 5MM SKRIPSI

RANCANG BANGUN HEAT EXCHANGER TUBE NON FIN SATU PASS, SHELL TIGA PASS UNTUK MESIN PENGERING EMPON-EMPON

JURNAL TEKNIK POMITS Vol. 3, No. 2, (2014) ISSN: ( Print) B-192

BAB I PENDAHULUAN. kebutuhan utama dalam sektor industri, energi, transportasi, serta dibidang

Publikasi Online Mahsiswa Teknik Mesin Universitas 17 Agustus 1945 Surabaya Volume 1 No. 1 (2018)

Analisis Karakteristik Rewetting Dalam Celah Sempit Vertikal Untuk Kasus Bilateral Heating Berdasarkan Perubahan Temperatur Awal Plat

BAB I PENDAHULUAN BAB I PENDAHULUAN

ESTIMASI PERHITUNGAN KALOR DAN LAJU ALIRAN KALOR PADA UNTAI FASSIP-02

WATER TO WATER HEAT EXCHANGER BENCH BAB I PENDAHULUAN. 1.1 Tujuan Pengujian

UNIVERSITAS DIPONEGORO EVALUASI KINERJA COOLING WATER HEAT EXCHANGER (CWHE) TIPE PLATE HEAT EXCHANGER (PHE) UNIT 1A DI PLTU 3 JAWA TIMUR TANJUNG AWAR

SKRIPSI ANALISIS PERFORMANSI KOLEKTOR SURYA PELAT DATAR DENGAN VARIASI SIRIP BERLUBANG

ANALISA PERFORMASI KOLEKTOR SURYA TERKONSENTRASI DENGAN VARIASI JUMLAH PIPA ABSORBER BERBENTUK SPIRAL

BAB II LANDASAN TEORI

ANALISIS KINERJA COOLANT PADA RADIATOR

INTEGRASI UNTAI UJI BETA (UUB) DENGAN BAGIAN UJI HeaTING-01 PADA BAGIAN MEKANIK

SOLUSI ANALITIK DAN SOLUSI NUMERIK KONDUKSI PANAS PADA ARAH RADIAL DARI PEMBANGKIT ENERGI BERBENTUK SILINDER

PENGGUNAAN FLUENT UNTUK SIMULASI DISTRIBUSI SUHU DAN KECEPATAN PADA ALAT PENUKAR KALOR

PENINGKATAN UNJUK KERJA KETEL TRADISIONAL MELALUI HEAT EXCHANGER

UNIVERSITAS DIPONEGORO TUGAS SARJANA. Disusun oleh:

STUDI PERPINDAHAN PANAS KONVEKSI PADA SUSUNAN SILINDER VERTIKAL DALAM REAKTOR NUKLIR ATAU PENUKAR PANAS MENGGUNAKAN PROGAM CFD

MODEL AUTOMATA PENGOPERASIAN DAN PERSIAPAN UNTAI UJI TERMOHIDRAULIKA BETA

JURUSAN TEKNIK MESIN FAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH SURAKARTA

BAB I PENDAHULUAN 1.1 Latar Belakang

UNIVERSITAS DIPONEGORO PERHITUNGAN KINERJA PERPINDAHAN PANAS LOW PRESSURE HEATER 5 DAN 6 UNIT 1 PADA BEBAN 350 MWPLTU 3 JAWA TIMUR TANJUNG AWAR-AWAR

Evaluasi Performa Lube Oil Cooler pada Turbin Gas dengan Variasi Surface Designation dan Reynolds Number

Karakteristik Perpindahan Panas pada Double Pipe Heat Exchanger, perbandingan aliran parallel dan counter flow

Karakteristik Perpindahan Panas dan Pressure Drop pada Alat Penukar Kalor tipe Pipa Ganda dengan aliran searah

PENINGKATAN EFISIENSI SISTEM PEMANAS AIR KAMAR MANDI MENGGUNAKAN INJEKSI GELEMBUNG UDARA

RANCANG BANGUN HEAT EXCHANGER TUBE FIN TIGA PASS SHELL SATU PASS UNTUK MESIN PENGERING EMPON-EMPON

PENENTUAN PREDIKSI WAKTU EKSPERIMEN PERPINDAHAN KALOR PENDIDIHAN MENGGUNAKAN BUNDEL UJI QUEEN-1

BAB I PENDAHULUAN di Bandung dan Reaktor Kartini yang berada di Yogyakarta. Ketiga reaktor

STUDI EKSPERIMENTAL PENGARUH VARIASI PITCH COILED TUBE TERHADAP NILAI HEAT TRANSFER DAN PRESSURE DROP PADA HELICAL HEAT EXCHANGER ALIRAN SATU FASA

POLA ALIRAN DUA FASE (AIR+UDARA) PADA PIPA HORISONTAL DENGAN VARIASI KECEPATAN SUPERFISIAL AIR

DEPARTEMEN TEKNIK MESIN FAKULTAS TEKNIK UNIVERSITAS SUMATERA UTARA MEDAN 2008

PENGUJIAN DIRECT EVAPORATIVE COOLING POSISI VERTIKAL DENGAN ALIRAN BERLAWANAN ARAH

ANALISIS PERHITUNGAN LAJU PERPINDAHAN PANAS ALAT PENUKAR KALOR TYPE PIPA GANDA DI LABORATORIUM UNIVERSITAS 17 AGUSTUS 1945 JAKARTA

BAB IV HASIL PENGAMATAN & ANALISA

REAKTOR GRAFIT BERPENDINGIN GAS (GAS COOLED REACTOR)

ANALISIS KINERJA PRECOOLER PADA SISTEM KONVERSI ENERGI RGTT200K UNTUK PROSES DESALINASI

BAB I PENDAHULUAN. Kemajuan teknologi bidang otomotif berkembang sangat pesat mendorong

ANALISIS PERPINDAHAN PANAS PADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGER DI SEKTOR PEMBANGKITAN PLTGU CILEGON

BAB I PENDAHULUAN. Gambar 1.1 Skema pressurized water reactor ( September 2015)

Analisis Termal Hidrolik Gas Cooled Fast Reactor (GCFR)

LAPORAN TUGAS AKHIR PEMBUATAN SISTEM SIRKULASI AIR PENDINGIN KONDENSOR PERALATAN PIROLISIS SAMPAH PLASTIK

ANALISIS PENGARUH EFEKTIVITAS PERPINDAHAN PANAS DAN TAHANAN TERMAL TERHADAP RANCANGAN TERMAL ALAT PENUKAR KALOR SHELL & TUBE

UJI PRESTASI PENDINGINAN EVAPORASI KONTAK TIDAK LANGSUNG (INDIRECT EVAPORATIVE COOLING) DENGAN VARIASI TEMPERATUR MEDIA PENDINGIN AIR

RANCANG BANGUN DAN PENGUJIAN HEAT EXCHANGER CROSS FLOW UNMIXED, FINNED TUBE FOUR PASS, UNTUK MENGERINGKAN EMPON-EMPON DENGAN VARIASI MASS FLOW RATE

DAFTAR ISI. KATA PENGANTAR... i. ABSTRAK... iv. DAFTAR ISI... vi. DAFTAR GAMBAR... xi. DAFTAR GRAFIK...xiii. DAFTAR TABEL... xv. NOMENCLATURE...

Pemodelan Sistem Sirkulasi Alami pada Reaktor nuklir dengan Variasi Ketinggian Alat yang Berbeda

BAB I PENDAHULUAN Latar Belakang Masalah. dengan globalisasi perdagangan dunia. Industri pembuatan Resin sebagai

RANCANG BANGUN DAN EVALUASI PERFORMA SHELL AND COIL HEAT EXCHANGER

PERPINDAHAN PANASPADA GAS TURBINE CLOSED COOLING WATER HEAT EXCHANGERDI SEKTOR PEMBANGKITAN PLTGU CILEGON

ANALISIS KEEFEKTIFAN ALAT PENUKAR KALOR TIPE SHELL AND TUBE SATU LALUAN CANGKANG DUA LALUAN TABUNG SEBAGAI PENDINGINAN OLI DENGAN FLUIDA PENDINGIN AIR

BAB II TINJAUAN PUSTAKA

STUDI EKSPERIMENTAL UNJUK KERJA RADIATOR PADA SUMBER ENERGI PANAS PADA RANCANG BANGUN SIMULASI ALAT PENGERING

Pengaruh Penggunaan Baffle pada Shell-and-Tube Heat Exchanger

SIMULASI ALIRAN PANAS PADA SILINDER YANG BERGERAK. Rico D.P. Siahaan, Santo, Vito A. Putra, M. F. Yusuf, Irwan A Dharmawan

SKRIPSI ANALISA KOMPARASI EKSPERIMENTAL KINERJA POMPA KALOR DENGAN MENGGUNAKAN REFRIGERAN R 134A DAN MC 134 UNTUK PRODUKSI AIR PANAS

EVALUASI DESAIN TERMAL KONDENSOR PLTN TIPE PWR MENGGUNAKAN PROGRAM SHELL AND TUBE HEAT EXCHANGER DESIGN

TUGAS AKHIR EKSPERIMEN HEAT TRANSFER PADA DEHUMIDIFIER DENGAN AIR DAN COOLANT UNTUK MENURUNKAN KELEMBABAN UDARA PADA RUANG PENGHANGAT

STUDI EKSPERIMENTAL KOEFISIEN PERPINDAHAN KALOR MODEL WATER HEATER KAPASITAS 10 LITER DENGAN INJEKSI GELEMBUNG UDARA

STUDI EKSPERIMENTAL PERFORMANSI COOLING PAD BERBAHAN SUMBU KOMPOR TANPA DUCTING DAN DENGAN DUCTING ABSTRAK

BAB II DASAR TEORI. ke tempat yang lain dikarenakan adanya perbedaan suhu di tempat-tempat

SKRIPSI ANALISA ENERGI PADA SISTEM PENGERING ANYAMAN ATA BERBAHAN BAKAR BRIKET SABUT KELAPA DENGAN MEMVARIASIKAN TIPE RAK PENGERING

TUGAS AKHIR. Analisa Performansi dan Perancangan Ulang Radiator Sebagai Optimasi Cooling System pada Mesin Sinjai

ANALISA PERFORMANSI COOLER LUBE OIL DENGAN KAPASITAS 300 TON/JAM PADA UNIT 2 DI PLTU LABUHAN ANGIN LAPORAN TUGAS AKHIR

KINERJA AIR CONDITONING HIBRIDA PADA LAJU ALIRAN AIR BERBEDA DENGAN KONDENSOR DUMMY TIPE HELICAL COIL (1/4", 6,7 m) SEBAGAI WATER HEATER

Jurnal Ilmiah TEKNIK DESAIN MEKANIKA Vol. 5 No. 3, September 2016 (1-6)

ANALISA EFEKTIVITAS HIGH PRESSURE HEATER UNIT 2 DENGAN LAJU ALIRAN AIR 59,721 kg/s PADA PLTU PANGKALAN SUSU PT PLN SEKTOR PEMBANGKITAN MEDAN

PERANCANGAN ALAT PENUKAR KALOR (HEAT EXCHANGER) TIPE SHELL AND TUBE 2 PASS UNTUK PENDINGINAN AIR DEMIN KAPASITAS 3, 37 MW

EFEK VARIASI TEMPERATUR PELAT PADA CELAH SEMPIT REKTANGULAR TERHADAP BILANGAN REYNOLDS

Analisa Pengaruh Laju Alir Fluida terhadap Laju Perpindahan Kalor pada Alat Penukar Panas Tipe Shell dan Tube

ANALISA COOLING SISTEM GE FRAME 9 PLTG SICANANG 120MW

BAB I. PENDAHULUAN...

Transkripsi:

ANALISIS PERPINDAHAN PANAS PADA COOLER TANK FASSIP - 01 Oleh : Aprianto Tangkesalu Dosen Pembimbing : Prof.Dr.Ir.I Gusti Bagus Wijaya Kusuma : Ir.I Nengah Suarnadwipa, MT ABSTRAKSI FASSIP-01 merupakan sebuah alat uji ekperimen yang dikhususkan untuk aliran satu-fasa dengan variabel parameter daya heater dan laju aliran pendingin di cooler. Pada sistem FASSIP-01 terdapat beberapa komponen penting salah satunya cooler tank. Cooler tank sendiri terdiri dari 2 bagian yaitu pipa refrigerator dan tabung cooler. Fungsi cooler tank adalah untuk mendinginkan fluida air yang telah dipanaskan pada bagian heater agar memberikan efek perubahan kerapatan fluida yang akan menimbulkan bergeraknya fluida air akibat gaya gravitasi. Hasil eksperimen sementara yang telah dilakukan di BATAN dibagian cooler tank khususnya di pipa refrigerator, diperoleh perubahan temperatur yang tidak signifikan pada aliran air di pipa refrigerator. Temperatur yang dihasilkan meningkatkan dari keadaan awal, yang seharusya tidak boleh mengingat fungsi dan kerjanya sebagai pendingin, dimana aliran fluida yang didinginkan di pipa refrigerator akan langsung disalurkan menuju tabung cooler untuk mendinginkan pipa utama. Penelitian ini ditujukan untuk menganalisis lebih dalam sistem perpindahan panas yang terjadi pada cooler tank melalui metode simulasi dan perhitungan matematis, untuk mengetahui seberapa besar temperatur fluida yang dapat diturunkan di pipa refrigerator yang akan menjadi fluida pendingin pipa utama di tabung cooler, sekaligus unjuk kerja daripada alat dan peningkatan kerja jika ada permukaan tambahan pada pipa utama di bagian dalam tabung cooler. Dari hasil analisis penelitian yang dilakukan ditemukan bahwa temperatur inlet-outlet di pipa refrigerator turun dari 26 0 C menjadi 21,57 0 C setelah terjadi proses pendinginan. Sementara dengan penambahan permukaan pada pipa utama tabung cooler menunjukkan adanya peningkatan kerja meliputi laju perpindahan panas, efektivitas dan NTU. Laju perpindahan panas yang dihasilkan tanpa permukaan tambahan sebesar 1116,68 Watt dengan efektivitas 51% dan NTU 0,71. Sementara dengan adanya permukaan tambahan berupa cincin rectangular sebanyak 10 buah menghasilkan laju perpindahan panas sebesar 1456 Watt dengan efektivitas sebesar 67% dan NTU 1,10 dengan efisiensi 82 %. Kata kunci: perpindahan panas, sirkulasi alamiah, heater dan cooler, simulasi, penambahan permukaan iii

ANALYSIS OF HEAT TRANSFER ON COOLER TANK FASSIP - 01 Author Guidance : Aprianto Tangkesalu : Prof.Dr.Ir.I Gusti Bagus Wijaya Kusuma : Ir.I Nengah Suarnadwipa, MT ABSTRACT FASSIP-01 is an experimental test equipment that dedicated to a singlephase flow with variable heater power parameters and coolant flow rate in the cooler. In FASSIP-01 system, there are several important components, one is a cooler tank. Cooler tank consists from refrigerator pipes and cooler tubes. Function of cooler tank to cool the fluid that has been heated in the heater in order to give effect of changes in fluid density which will cause the fluid movement due to the force of gravity. The experimental cooler tank results that had been done in BATAN, especially in refrigerator pipes, the change of temperature is not significant in the flow of water in the refrigerator pipes. The resulting temperature increase from the initial state, which is should not be happened as the functions and works as cooler. This study aimed to analyze the heat transfer systems that occur on the cooler tank through simulation methods and mathematical calculations, to determine how much fluid temperature can be descreased in the refrigerator pipes which will be the fluid coolant in the cooler tubes, and performance that will increase in system if there is extended surface on the main pipe inside of the cooler tubes. From the analysis of research conducted found that the temperature at the inlet-outlet refrigerator pipes is descreased from 26 o C into 21,57 o C after cooling process. The extended surface on the main pipe cooler tubes showed an increase of work includes the heat transfer rate, effectiveness and NTU. The resulting rate of heat transfer without extended surface at 1116.68 Watt with effectiness 51% and NTU 0.71. While the extended surface with the form of a rectangular fins with 10 pieces produces the heat transfer rate at 1456 Watt with effectiveness 67% and NTU 1.10 as the fins efficiency 82%. Keywords: heat transfer, natural circulation, heater and cooler, simulation, extended surface iv

DAFTAR ISI Halaman LEMBAR PENGESAHAN... i LEMBAR PERSETUJUAN... ii ABSTRAK... iii ABSTRACT... iv KATA PENGANTAR... v DAFTAR ISI... vi DAFTAR GAMBAR... viii DAFTAR TABEL... ix BAB I PENDAHULUAN... 1 1.1 Latar Belakang... 1 1.2 Rumusan Masalah... 2 1.3 Batasan Masalah... 3 1.4 Tujuan Penelitian... 3 1.5 Manfaat Penelitian... 3 BAB II LANDASAN TEORI... 4 2.1 Nuklir... 4 2.1.1 Reaktor Nuklir... 4 2.2 FASSIP-01... 6 2.2.1 Cara Kerja Untai FASSIPP-01... 8 2.2.2 Cooler Tank FASSIP-01... 8 2.3 Konsep Tahanan Thermal dan Koefisien Perpindahan Panas Keseluruhan... 11 2.4 Analisis Perpindahan Panas Pada Cooler Tank FASSIP-01.. 15 2.5 NTU-Efektivitas Heat Exchanger... 16 2.6 Efisiensi Extended Surface... 17 BAB III METODE PENELITIAN... 18 3.1 Deskripsi Penelitian... 18 3.2 Kebutuhan Data... 18 3.3 Alat dan Bahan... 19 3.4 Prosedur Analisis..... 19 3.5 Langkah Penelitian... 20 3.6 Pengujian Awal.... 20 3.7 Diagram Alir Penelitian... 25 3.8 Tempat dan Waktu Penelitian.. 29 3.7.1 Tempat Penelitian... 29 3.7.2 Waktu Penelitian... 29 BAB IV HASIL DAN PEMBAHASAN... 30 vi

4.1 Analisis Perpindahan Panas Pada Cooler Tank FASSIP-01.. 30 4.1.1 Simulasi Perpindahan Panas Pada Pipa Refrigerator dan Tabung Cooler FASSIP-01... 31 4.1.2 Perhitungan Hambatan Termal Pada Pipa Refrigerator Serta Tout sesungguhnya... 40 4.1.3 Perhitungan Hambatan Termal Pada Tabung Cooler Serta Tout sesungguhnya... 44 4.2 Analisa Efektivitas-NTU Pipa Utama Tabung Cooler Tanpa Permukaan Tambahan... 48 4.3 Analisa Perpidahan Panas Pada Pipa Utama Tabung Cooler dengan Permukaan Tambahan... 52 4.3.1 Gambar Skematik Penambahan Permukaan Pipa Utama Tabung Cooler... 53 4.3.2 Analisa Efektivitas-NTU Pipa Utama Dengan Permukaan Tambahan... 54 4.3.3 Analisa Keseluruhan Sistem Cooler Tank... 57 BAB V PENUTUP... 59 5.1 Simpulan... 59 5.2 Saran-Saran... 59 DAFTAR PUSTAKA. 61 LAMPIRAN PERNYATAAN LEMBAR ASISTENSI SK SKRIPSI/PEMBIMBING vii

DAFTAR GAMBAR Halaman Gambar 2.1 Skema Boilig Water Reactor... 5 Gambar 2.2 Skema Pressurized Water Reactor... 6 Gambar 2.3 Fasilitas Simulasi Sistem Pasif... 7 Gambar 2.4 Pipa refrigerator... 9 Gambar 2.5 Tabung cooler... 9 Gambar 2.6 Loop/Sirkulasi dari proses pendinginan tabung cooler... 10 Gambar 2.7 Aliran Kalor satu-dimensi melalui silinder berlubang... 11 Gambar 2.8 Aliran kalor satu-dimensi melalui penampang silinder... 12 Gambar 2.9 Diagram Efficiency of annular fins of rectangular profile.. 17 Gambar 2.10 Persamaan efisiensi extended surface berbentuk lingkaran. 17 Gambar 3.1 Pengukuran temperatur pada computer... 21 Gambar 3.2 Grafik perubahan temperature terhadap waktu... 23 Gambar 3.3 Pipa refrigerator... 24 Gambar 3.4 Dimensi pipa refrigerator... 24 Gambar 3.5 Potongan pipa refrigerator... 24 Gambar 3.6 Diagram alir penelitian... 25 Gambar 4.1 Pipa refrigerator yang akan disimulasikan... 30 Gambar 4.2 Tabung cooler yang akan disimulasikan... 31 Gambar 4.3 Grid dari pipa refrigerator... 32 Gambar 4.4 Plot iterasi... 33 Gambar 4.5 Temperatur fluida pipa refrigerator all zones... 34 Gambar 4.6 Temperatur fluida dalam tabung annulus... 34 Gambar 4.7 Velocity stream fluida di annulus... 35 Gambar 4.8 Temperatur fluida dalam pipa... 35 Gambar 4.9 Grid dari tabung cooler... 36 Gambar 4.10 Plot iterasi... 37 Gambar 4.11 Temperatur fluida di tabung cooler all zones... 38 Gambar 4.12 Temperatur fluida dalam tabung cooler... 38 Gambar 4.13 Velocity stream line pada tabung cooler... 39 Gambar 4.14 Temperatur fluida dalam pipa utama... 39 Gambar 4.15 Aliran kalor dari pipa refrigerator dan analogi listriknya.. 40 Gambar 4.16 Aliran kalor dari tabung cooler dan analogi listriknya... 44 Gambar 4.17 Plot iterasi... 49 Gambar 4.18 Temperatur fluida all zones... 49 Gambar 4.19 Skematik perpindahan panas pada tabung cooler... 50 Gambar 4.20 Permukaan tambahan pada pipa utama berbentuk spiral... 53 Gambar 4.21 Dimensi permukaan tambahan... 53 Gambar 4.22 Diagram efisiensi sirip... 55 viii

DAFTAR TABEL Halaman Tabel 2.1 Ukuran geometri FASSIP-01... 7 Tabel 3.1 Data hasil pengukuran temperatur... 22 Tabel 3.2 Jadwal penelitian... 29 Tabel 4.1 Nilai temperatur hasil simulasi pipa refrigerator... 36 Tabel 4.2 Nilai temperatur hasil simulasi tabung cooler... 40 Tabel 4.3 Data kuantitas simulasi hasil sesungguhnya... 50 Tabel 4.4 Perbandingan antara tanpa dan dengan permukaan yang diperluas... 57

1 BAB I PENDAHULUAN 1.1 Latar Belakang Filosofi keselamatan reaktor nuklir dengan motto 3C (control, cooling, contains) menjadi pilar utama dalam pengoperasian dan penanganan pasca kecelakaan suatu pembangkit listrik tenaga nuklir (PLTN). Salah satu pilar dari 3C adalah cooling atau penanganan proses pendinginan yang dikenal dengan manajemen termal (thermal management). Kecelakaan PLTN yang pernah terjadi dan masuk kategori kecelakaan parah (severe accident) seperti kecelakaan pada PLTN jenis pressurized water reactor (PWR) Three Mile Island Unit 2 (TMI-2) tahun 1979 dan PLTN jenis boiling water reactor (BWR) Fukushima Daiichi tahun 2011 sebagian besar diakibatkan oleh kegagalan dalam manajemen termal pasca kecelakaan. Mengacu pada kejadian tersebut para peneliti di BATAN (Badan Tenaga Nuklir Nasional) khususnya dibidang PTKRN (Pusat Teknologi dan Keselamatan Reaktor Nuklir) mencoba menciptakan dan menkaji sebuah prototype reaktor yang dinamai FASSIP-01 (Fasilitas Simulasi Sistem Pasif) (Juarsa, 2015). FASSIP sejatinya merupakan sebuah alat uji ekperimen yang dikhususkan untuk aliran satu-fasa dengan variabel parameter daya heater dan laju aliran pendingin di cooler, Konsep sistem pasif adalah aliran fluida yang bergerak tanpa adanya intervensi gaya-gaya dari luar dan berbasis pada hukum-hukum alam yang berlaku, dimana fenomena laju aliran fluida dalam sistem pasif disebut sirkulasi alamiah (natural circulation) yang timbul berdasarkan perbedaan kerapatan fluida. Efek perubahan kerapatan fluida di daerah panas akan menimbulkan gaya buoyancy (gaya apung) dan efek perubahan kerapatan fluida di daerah dingin akan menimbulkan gaya gravitasi. Fenomena tersebutlah yang diharapkan dapat diimplementasikan pada PLTN sehingga ketika terjadi kegagalan manajemen termal, sirkulasi alamiah yang diterapkan dapat berfungsi sehingga dapat mencengah terjadinya kecelakan reaktor nuklir. Selain desain dan konstruksi fasilitas eksperimen FASSIP-01 yang telah dilakukan, karakterisasi dan analisis fenomena sirkulasi alamiah juga dilakukan. Beberapa parameter penting yang terlibat dalam fenomena sirkulasi alamiah seperti

2 tekanan dan laju aliran fluida. Sedangkan parameter geometri adalah panjang untai, diameter pipa dan ketinggian antara daerah heater dan cooler. Laju aliran massa merupakan fungsi dari variabel temperatur (perubahan daya heater dan laju aliran pendinginan di cooler), ketinggian antara heater dan cooler. Hasil eksperimen sementara yang telah dilakukan di BATAN khususnya di bagian laju pendinginan cooler, diperoleh perubahan temperatur yang tidak signifikan pada aliran air di pipa refrigerator. Temperatur yang dihasilkan meningkatkan dari keadaan awal, yang seharusya tidak boleh mengingat fungsi dan kerjanya sebagai pendingin, dimana fluida dingin yang dihasilkan di pipa refrigerator akan disalurkan menuju ke tabung cooler untuk mendinginkan pipa utama dari FASSIP-01. Hal ini menunjukkan bahwa sistem penukar kalor di cooler tank FASSIP-01 belum bekerja sesuai fungsinya. Oleh karena itu pada kesempatan kali ini penulis hendak menganalisis dan mendesain kembali sistem perpindahan panas yang terjadi di cooler tank serta unjuk kerja daripada cooler tank FASSIP-01 itu sendiri. Seperti yang kita ketahui bahwa adanya peningkatan laju perpindahan kalor pada alat penukar kalor akan berdampak pada meningkatnya efektifitas kerja alat penukar kalor itu sendiri. Mengingat konsep kerja cooler tank FASSIP-01 yang merupakan aplikasi dari alat penukar kalor, menjadi dasar penulis untuk mencoba mendesain kembali pipa utama yang baru di tabung cooler dengan menambahkan extended surface dengan harapan untuk meningkatkan laju perpindahan kalor di tabung cooler sehingga dapat terjadi peningkatan efektifitas. Dengan adanya peningkatan efektifitas itu sendiri penulis berharap akan mampu pula meningkatkan unjuk kerja daripada FASSIP-01 secara keseluruhan. 1.2 Rumusan Masalah Berdasarkan latar belakang diatas permasalahan yaitu: 1. Bagaimanakah analisis perpindahan panas yang terjadi pada sistem Cooler Tank FASSIP-01 secara khusus dan sistem FASSIP-01 secara keseluruhan? 2. Bagaimanakah peningkatan kerja yang dihasilkan dengan penambahan extended surface pada pipa utama tabung cooler?

3 1.3 Batasan Masalah Agar penelitian tidak terlalu melebar, batasan masalah dalam penelitian ini adalah sebagai berikut : 1. Penelitian hanya difokuskan pada perpindahan panas yang terjadi pada cooler tank FASSIP-01. 2. Aliran steady. 3. Tidak ada energi tersimpan dalam sistem 4. Tidak ada energi terbangkitkan dalam sistem 1.4 Tujuan Adapun tujuan yang ingin dicapai dalam melakukan penelitian ini yaitu : 1. Menganalisis perpindahan panas yang terjadi pada sistem Cooler Tank FASSIP-01 secara khusus dan sistem FASSIP-01 secara keseluruhan. 2. Menganalisis peningkatan kerja yang dihasilkan dengan penambahan extended surface pada pipa utama tabung cooler. 1.5 Manfaat Penelitian Penelitian yang akan dilakukan, diharapkan dapat memberikan beberapa manfaat seperti berikut; 1. Memberikan gambaran tentang FASSIP-01. 2. Dapat menjadi stimulus dalam penelitian FASSIP-01 selanjutnya di Jurusan Teknik Mesin Udayana.