PENGARUH SIFAT MEKANIK BAJA TERHADAP GEDUNG BERTINGKAT DENGAN ANALISIS PUSHOVER ABSTRAK

dokumen-dokumen yang mirip
STUDI MENENTUKAN PARAMETER DAKTILITAS STRUKTUR GEDUNG TIDAK BERATURAN DENGAN ANALISIS PUSHOVER

STUDI EVALUASI KINERJA STRUKTUR BAJA BERTINGKAT RENDAH DENGAN ANALISIS PUSHOVER ABSTRAK

PERENCANAAN GEDUNG BETON BERTULANG BERATURAN BERDASARKAN SNI DAN FEMA 450

PEMODELAN DINDING GESER BIDANG SEBAGAI ELEMEN KOLOM EKIVALEN PADA MODEL GEDUNG TIDAK BERATURAN BERTINGKAT RENDAH

ANALISIS PENGARUH BENTUK SHEAR WALL TERHADAP PERILAKU GEDUNG BERTINGKAT TINGGI ABSTRAK

ANALISIS DINAMIK BEBAN GEMPA RIWAYAT WAKTU PADA GEDUNG BETON BERTULANG TIDAK BERATURAN

DESAIN TAHAN GEMPA BETON BERTULANG PENAHAN MOMEN MENENGAH BERDASARKAN SNI BETON DAN SNI GEMPA

ANALISIS DAN DESAIN STRUKTUR TAHAN GEMPA DENGAN SISTEM BALOK ANAK DAN BALOK INDUK MENGGUNAKAN PELAT SEARAH

PERENCANAAN STRUKTUR RANGKA BAJA BRESING TAHAN GEMPA

ANALISIS DINAMIK RAGAM SPEKTRUM RESPONS GEDUNG TIDAK BERATURAN DENGAN MENGGUNAKAN SNI DAN ASCE 7-05

DESAIN DINDING GESER TAHAN GEMPA UNTUK GEDUNG BERTINGKAT MENENGAH. Refly. Gusman NRP :

EVALUASI SENDI PLASTIS DENGAN ANALISIS PUSHOVER PADA GEDUNG TIDAK BERATURAN

ANALISIS DAN DESAIN STRUKTUR BETON BERTULANG UNTUK GEDUNG TINGKAT TINGGI

PENGARUH PENINGKATAN KAPASITAS AIR TERHADAP KEKUATAN STRUKTUR BAK SEDIMENTASI PADA INSTALASI PENGOLAHAN AIR

KINERJA STRUKTUR RANGKA BETON BERTULANG DENGAN PERKUATAN BREISING BAJA TIPE X

DAFTAR ISI KATA PENGANTAR DAFTAR TABEL DAFTAR GAMBAR DAFTAR LAMPIRAN DAFTAR NOTASI DAN SIMBOL

3.4.5 Beban Geser Dasar Nominal Statik Ekuivalen (V) Beban Geser Dasar Akibat Gempa Sepanjang Tinggi Gedung (F i )

ANALISIS DAN DESAIN PADA STRUKTUR BAJA DENGAN SISTEM RANGKA BRESING KONSENTRIK BIASA (SRBKB) DAN SISTEM RANGKA BRESING KONSENTRIK KHUSUS (SRBKK)

BAB 1 PENDAHULUAN. hingga tinggi, sehingga perencanaan struktur bangunan gedung tahan gempa

BAB II TINJAUAN PUSTAKA

PERANCANGAN STRUKTUR ATAS GEDUNG CONDOTEL MATARAM CITY YOGYAKARTA. Oleh : KEVIN IMMANUEL KUSUMA NPM. :

PERENCANAAN STRUKTUR RANGKA BAJA BERATURAN TAHAN GEMPA BERDASARKAN SNI DAN FEMA 450

STUDI DESAIN STRUKTUR BETON BERTULANG TAHAN GEMPA UNTUK BENTANG PANJANG DENGAN PROGRAM KOMPUTER

PENGARUH GAYA AKSIAL TERHADAP LUAS TULANGAN PENGEKANG KOLOM BETON BERTULANG PERSEGI ABSTRAK

PERENCANAAN STRUKTUR PORTAL DENGAN BALOK PRATEGANG

ANALISIS DAN DESAIN STRUKTUR FLAT PLATE BETON BERTULANG UNTUK GEDUNG EMPAT LANTAI TAHAN GEMPA

ANALISIS DINAMIK RIWAYAT WAKTU AKIBAT GEMPA UTAMA DAN GEMPA SUSULAN PADA GEDUNG BETON BERTULANG

DAFTAR ISI JUDUL LEMBAR PENGESAHAN PERNYATAAN BEBAS PLAGIAT PERSEMBAHAN KATA PENGANTAR DAFTAR GAMBAR DAFTAR TABEL DAFTAR NOTASI

DESAIN GEDUNG BETON BERTULANG DENGAN PERENCANAAN BERBASIS PERPINDAHAN

BAB IV EVALUASI KINERJA DINDING GESER

ANALISIS PERILAKU STRUKTUR PELAT DATAR ( FLAT PLATE ) SEBAGAI STRUKTUR RANGKA TAHAN GEMPA TUGAS AKHIR

Denley Martin Sudewo NRP : Pembimbing : Djoni Simanta., Ir.,MT FAKULTAS TEKNIK JURUSAN TEKNIK SIPIL UNIVERSITAS KRISTEN MARANATHA BANDUNG

DAFTAR ISI. Halaman Judul Pengesahan Persetujuan Surat Pernyataan Kata Pengantar DAFTAR TABEL DAFTAR GAMBAR DAFTAR NOTASI DAFTAR LAMPIRAN

DESAIN BALOK SKYBRIDGE PENGHUBUNG DUA GEDUNG DENGAN BAJA PROFIL BOX DAN IWF FERDIANTO NRP : Pembimbing : Dr. YOSAFAT AJI PRANATA, S.T.,M.T.

TESIS EVALUASI KINERJA STRUKTUR GEDUNG BETON BERTULANG SISTEM GANDA DENGAN ANALISIS NONLINEAR STATIK DAN YIELD POINT SPECTRA O L E H

TUGAS AKHIR PERENCANAAN GEDUNG DUAL SYSTEM 22 LANTAI DENGAN OPTIMASI KETINGGIAN SHEAR WALL

STUDI PERBANDINGAN ANALISIS PELAT KONVENSIONAL DAN PELAT PRACETAK ABSTRAK

DAFTAR NOTASI BAB I β adalah faktor yang didefinisikan dalam SNI ps f c adalah kuat tekan beton yang diisyaratkan f y

PENGARUH SENSITIFITAS DIMENSI DAN PENULANGAN KOLOM PADA KURVA KAPASITAS GEDUNG 7 LANTAI TIDAK BERATURAN

ANALISIS PEMBEBANAN BESMEN TAHAN GEMPA

Contoh Perhitungan Beban Gempa Statik Ekuivalen pada Bangunan Gedung

BAB II TINJAUAN PUSTAKA. Beton berlulang merupakan bahan konstruksi yang paling penting dan merupakan

STUDI EKSPERIMENTAL MATERIAL BAJA TULANGAN DARI BERBAGAI DISTRIBUTOR DI BANDUNG ABSTRAK

HALAMAN JUDUL HALAMAN PENGESAHAN MOTTO DAN PERSEMBAHAN KATA PENGANTAR ABSTRAK DAFTAR ISI DAFTAR GAMBAR DAFTAR TABEL DAFTAR NOTASI DAFTAR LAMPIRAN

STUDI ANALISIS PERTEMUAN BALOK KOLOM BERBENTUK T STRUKTUR RANGKA BETON BERTULANG DENGAN PEMODELAN STRUT-AND- TIE ABSTRAK

PERANCANGAN STRUKTUR ATAS GEDUNG TRANS NATIONAL CRIME CENTER MABES POLRI JAKARTA. Oleh : LEONARDO TRI PUTRA SIRAIT NPM.

1.6 Tujuan Penulisan Tugas Akhir 4

ANALISIS PORTAL BETON BERTULANG PADA STRUKTUR GEDUNG BERTINGKAT BANYAK DENGAN TINGKAT DAKTILITAS PENUH DAN ELASTIK PENUH

TUGAS AKHIR ANALISA EFISIENSI STRUKTUR DENGAN METODE PSEUDO ELASTIS TERHADAP METODE DESAIN KAPASITAS PADA BANGUNAN BERATURAN DI WILAYAH GEMPA 5

PERENCANAAN STRUKTUR GEDUNG PARKIR SUNTER PARK VIEW APARTMENT DENGAN METODE ANALISIS STATIK EKUIVALEN

APLIKASI BUILDING INFORMATION MODELING (BIM) DALAM PERANCANGAN BANGUNAN BETON BERTULANG 4 LANTAI ABSTRAK

EVALUASI KINERJA INELASTIK STRUKTUR RANGKA BETON BERTULANG TERHADAP GEMPA DUA ARAH TUGAS AKHIR PESSY JUWITA

TUGAS AKHIR PERENCANAAN STRUKTUR KONSTRUKSI BAJA GEDUNG DENGAN PERBESARAN KOLOM

PERKUATAN SEISMIK STRUKTUR GEDUNG BETON BERTULANG MENGGUNAKAN BREISING BAJA TIPE-X TUGAS AKHIR

T I N J A U A N P U S T A K A

PERBANDINGAN PERILAKU ANTARA STRUKTUR RANGKA PEMIKUL MOMEN (SRPM) DAN STRUKTUR RANGKA BRESING KONSENTRIK (SRBK) TIPE X-2 LANTAI

ANALISA KINERJA STRUKTUR BETON BERTULANG DENGAN KOLOM YANG DIPERKUAT DENGAN LAPIS CARBON FIBER REINFORCED POLYMER (CFRP)

ANALISIS KINERJA STRUKTUR GEDUNG DENGAN COREWALL TUGAS AKHIR

ANALISIS DAN DESAIN STRUKTUR BANGUNAN BETON BERTULANG 10 LANTAI TAHAN GEMPA PENAHAN MOMEN MENENGAH (SRPMM)

PERENCANAAN GEDUNG YANG MEMPUNYAI KOLOM MIRING DENGAN PUSHOVER ANALYSIS

Analisis Perilaku Struktur Pelat Datar ( Flat Plate ) Sebagai Struktur Rangka Tahan Gempa BAB III STUDI KASUS

EVALUASI KINERJA PORTAL BAJA 3 DIMENSI DENGAN PENGAKU LATERAL AKIBAT GEMPA KUAT BERDASARKAN PERFORMANCE BASED DESIGN

ANALISIS LENDUTAN SEKETIKA dan LENDUTAN JANGKA PANJANG PADA STRUKTUR BALOK. William Trisina NRP : Pembimbing : Daud Rahmat Wiyono, Ir.,M.Sc.

STUDI KOMPARATIF PERANCANGAN STRUKTUR GEDUNG TAHAN GEMPA DENGAN SISTEM RANGKA GEDUNG BERDASARKAN TATA CARA ASCE 7-05 DAN SNI

BAB III METODOLOGI PENELITIAN

BAB III METODELOGI PENELITIAN

DETEKSI DINI POLA KERUNTUHAN STRUKTUR PORTAL GEDUNG H UNIVERSITAS MUHAMMADIYAH SURAKARTA AKIBAT GEMPA. Tugas Akhir

PROGRAM STUDI TEKNIK SIPIL FAKULTAS TEKNIK UNIVERSITAS ATMA JAYA YOGYAKARTA YOGYAKARTA

PERILAKU DAN KINERJA STRUKTUR RANGKA BAJA DENGAN DINDING PENGISI DAN TANPA DINDING PENGISI

ANALISIS LENDUTAN SEKETIKA DAN JANGKA PANJANG PADA STRUKTUR PELAT DUA ARAH. Trinov Aryanto NRP : Pembimbing : Daud Rahmat Wiyono, Ir., M.Sc.

DAFTAR ISI. BAB II TINJAUAN PUSTAKA Tinjauan Umum Wilayah Gempa... 6

PERENCANAAN GEDUNG BETON BERTULANG TIDAK BERATURAN BERDASARKAN SNI DAN FEMA 450 ABSTRAK

ANALISIS DAN DESAIN BALOK TRANSFER BETON PRATEGANG PADA BANGUNAN 9 LANTAI TAHAN GEMPA. Dani Firmansyah NRP :

ABSTRAK. Kata kunci: perkuatan, struktur rangka beton bertulang, dinding geser, bracing, pembesaran dimensi, perilaku. iii

PERENCANAAN STRUKTUR GEDUNG RUSUNAWA UNIMUS

BAB IV PERMODELAN STRUKTUR

PEMODELAN STRUKTUR RANGKA BETON BERTULANG DENGAN PERKUATAN BREISING KONSENTRIK V-TERBALIK

DAFTAR NOTASI. Luas penampang tiang pancang (mm²). Luas tulangan tarik non prategang (mm²). Luas tulangan tekan non prategang (mm²).

EVALUASI PERBANDINGAN KONSEP DESAIN DINDING GESER TAHAN GEMPA BERDASARKAN SNI BETON

DAFTAR ISI. 1.1 Latar Belakang Perumusan Masalah Tujuan Batasan Masalah Manfaat... 4 BAB II TINJAUAN PUSTAKA...

PENGARUH BRACING PADA PORTAL STRUKTUR BAJA

BAB III STUDI KASUS 3.1 UMUM

DESAIN JEMBATAN BETON BERTULANG ANTARA PULAU BIDADARI DAN PULAU KELOR

STUDI ANALISIS JEMBATAN SEBAGAI PENGHUBUNG GEDUNG BETON BERTULANG ENAM LANTAI ABSTRAK

KEBUTUHAN MATERIAL PADA PERENCANAAN PORTAL BETON BERTULANG DENGAN SISTEM DAKTAIL PARSIAL DI WILAYAH GEMPA 3. Naskah Publikasi

ANALISIS DAKTILITAS BALOK BETON BERTULANG

BAB IV POKOK PEMBAHASAN DESAIN. Perhitungan prarencana bertujuan untuk menghitung dimensi-dimensi

BAB II TINJAUAN PUSTAKA. gedung dalam menahan beban-beban yang bekerja pada struktur tersebut. Dalam. harus diperhitungkan adalah sebagai berikut :

BAB II TINJAUAN PUSTAKA

PERBANDINGAN ANALISIS STATIK DAN ANALISIS DINAMIK PADA PORTAL BERTINGKAT BANYAK SESUAI SNI

PENGGAMBARAN DIAGRAM INTERAKSI KOLOM BAJA BERDASARKAN TATA CARA PERENCANAAN STRUKTUR BAJA UNTUK BANGUNAN GEDUNG (SNI ) MENGGUNAKAN MATLAB

PEMODELAN NUMERIK METODE ELEMEN HINGGA RUMAH TINGGAL TERHADAP BEBAN GEMPA

PERANCANGAN ULANG STRUKTUR GEDUNG BANK MODERN SOLO

PERANCANGAN STRUKTUR BANGUNAN RUMAH SUSUN DI YOGYAKARTA

ANALISIS LENTUR DAN GESER BALOK PRACETAK DENGAN TULANGAN SENGKANG KHUSUS ABSTRAK

PERANCANGAN STRUKTUR ATAS STUDENT PARK APARTMENT SETURAN YOGYAKARTA

DAFTAR ISTILAH. Al = Luas total tulangan longitudinal yang memikul puntir

ANALISIS PERUBAHAN SISTEM STRUKTUR KONVENSIONAL MENJADI SISTEM PRACETAK UNTUK GEDUNG RUSUNAWA DI MENADO T-24 DENGAN MENGGUNAKAN PROGRAM ETABS9.

BAB II TINJAUAN PUSTAKA. pembebanan yang berlaku untuk mendapatkan suatu struktur bangunan

BAB IV PEMODELAN STRUKTUR

Transkripsi:

PENGARUH SIFAT MEKANIK BAJA TERHADAP GEDUNG BERTINGKAT DENGAN ANALISIS PUSHOVER Christian Jaya Kusuma NRP : 1121019 Pembimbing : Ronald Simatupang, S.T.,M.T ABSTRAK Pesatnya pembangunan di Indonesia mengakibatkan banyaknya permintaan akan bahan bangunan khususnya baja tulangan. Persaingan yang ketat membuat beberapa produsen baja tulangan memproduksi tulangan yang tidak sesuai dengan standar yang berlaku dengan tujuan dapat dijual dengan harga murah dan laku di pasaran, penggunaan tulangan yang tidak sesuai standar tentunya ditujukan untuk pengurangan atau penghematan biaya pembangunan akan tetapi berdampak besar bagi struktur. Tujuan dari penelitian ini adalah mempelajari pengaruh dari penggunaan tulangan yang sesuai standar dan yang tidak sesuai standar pada struktur dengan menggunakan perangkat lunak kemudian membandingkan kedua hasil analisis tersebut. Dalam studi ini bangunan didesain sesuai Tata Cara Perencanaan Ketahanan Gempa untuk Bangunan Gedung [SNI 1726-2002]. Kemudian perilaku struktur yang menggunakan tulangan standar dan yang tidak ini dievaluasi dengan menggunakan analisis statik beban dorong (static nonlinier/pushover analysis). Hasil analisis menunjukkan bahwa penggunan baja tulangan non-standar oleh pengaruh tegangan leleh (fy) lebih besar 8.5% dan tegangan putus (fu) lebih besar 0.83% adalah kapasitas gaya geser yang mampu diterima oleh struktur lebih besar 9.6%. Kapasitas momen leleh balok lebih besar berkisar antara 9.2-9.8% dan momen maksimum balok lebih besar berkisar antara 0.4-4%. Kapasitas aksial kolom lebih besar 3.6% dan momen maksimum kolom lebih besar 1.6%. Daktilitas struktur dengan baja tulangan standar adalah 6 dibandingkan daktilitas struktur dengan tulangan non-standar adalah 4.5. Daktilitas kurvatur balok dengan menggunakan tulangan standar berkisar antara 4-6 dibandingkan balok dengan tulangan non-standar berkisar antara 3.2-3.6. Daktilitas kurvatur kolom dengan tulangan standar 3.88 dibandingkan kolom dengan tulangan non-standar 3.22, penurunan daktilitas ini dipengaruhi oleh daktilitas dari baja tulangan dan perbedaan nilai modulus elastisitas tulangan. Kata Kunci: Pushover, Kurva Kapasitas, Sendi Plastis, Kapasitas kolom, Tulangan Standar, Tulangan Non-Standar ix Universitas Kristen Maranatha

EFFECT OF MECHANICAL PROPERTIES OF STEEL FOR MULTILEVEL BUILDING WITH PUSHOVER ANALYSIS Christian Jaya Kusuma NRP: 1121019 Advisor: Ronald Simatupang, S.T., M.T ABSTRACT The rapid development in Indonesia resulted in many requests for building materials, especially steel reinforcement. Intense competition make some manufacturers produce reinforcing steel bars which are not in accordance with the standards applicable to the destination can be sold at a low price and sell at the market, the use of reinforcement that is not according to the standard course is intended for reduction or cost savings but the development will have a major impact for the structure. The purpose of this research was to study the effect of reinforcing the use of appropriate standards and that does not conform to the standard structure using the software then compares the results of the analysis. In this study, the building is designed based on that used in Indonesia (SNI 1726-2002). Then the behavior of structures using standard reinforcement and not standard reinforcement evaluated using nonlinear analysis (pushover analysis). The analysis showed that the use of non-standard steel reinforcement by the influence of yield stress (fy) is greater 8.5% and tensile strength (fu) greater 0.83% are shear force structures capacity is 9.6% larger. Moment yield capacity of beam range between 9.2-9.8% and a maximum moment of beam range between 0.4-4%. Axial Capacity column is 3.6% greater and maximum moment is 1.6% greater. Ductility structure with standard reinforcement steel is 6 compared ductility reinforcement structure with non-standard is 4.5. Curvature ductility beam using standard reinforcement beams ranged between 4-6 compared with the reinforcement of non-standard ranges between 3.2-3.6. Curvature ductility column with standard reinforcement is 3.88 compared with the column of non-standard reinforcement is 3.22, decrease in ductility is influenced by the reinforcing steel ductility and difference of elasticity modulus value reinforcement. Keywords: Pushover, capacity curve, Hinge, Capacity column, Standard Reinforcement, Non-Standard Reinforcement x Universitas Kristen Maranatha

DAFTAR ISI HALAMAN JUDUL... LEMBAR PENGESAHAN PERNYATAAN ORISINALITAS LAPORAN PENELITIAN PERNYATAAN PUBLIKASI LAPORAN PENELITIAN... SURAT KETERANGAN TUGAS AKHIR.. SURAT KETERANGAN SELESAI TUGAS AKHIR. i ii iii iv v vi KATA PENGANTAR vii ABSTRAK. ABSTRACT. DAFTAR ISI.. ix x xi DAFTAR GAMBAR. xiv DAFTAR TABEL.. xx DAFTAR NOTASI xxi DAFTAR LAMPIRAN. xxiii BAB I PENDAHULUAN 1.1 Latar Belakang. 1 1.2 Tujuan Penelitian. 2 1.3 Pembatasan Masalah 2 1.4 Ruang Lingkup Penelitian 3 1.5 Sistematika Penelitian. 3 1.6 Lisensi Perangkat Lunak.. 3 xi Universitas Kristen Maranatha

BAB II STUDI PUSTAKA 2.1 Beton Bertulang 4 2.1.1 Sifat Mekanis Beton Bertulang. 4 2.1.2 Hubungan Momen-Kurvatur Penampang.. 13 2.2 Baja Tulangan.. 15 2.3 Teori Gedung Tahan Gempa 18 2.4 Pushover Analisis 19 2.5 Peraturan... 30 2.5.1 SNI 1726-2002 Standar Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung... 30 BAB III METODOLOGI PENELITIAN 3.1 Properties Material... 38 3.2 Denah Struktur.... 39 3.3 Diagram Alir Penelitian... 41 3.4 Input SAP2000 42 3.5 Pemodelan Analisis Balok Dan Kolom... 51 BAB IV ANALISA DATA 4.1 Analisis Pemodelan 52 4.1.1 Pembatasan Waktu Getar Alami Fundamental 52 4.1.2 Distribusi Gaya Geser Dasar Horizontal... 53 4.1.3 Kinerja Batas Layan. 56 4.2 Analisis Pushover... 57 4.3 Analisis Balok. 62 4.4 Analisis Kolom 66 BAB V SIMPULAN DAN SARAN 5.1 Simpulan. 70 5.2 Saran 72 xii Universitas Kristen Maranatha

DAFTAR PUSTAKA 73 LAMPIRAN.. 75 xiii Universitas Kristen Maranatha

DAFTAR GAMBAR Gambar 2.1 Gambar 2.2 Gambar 2.3 Gambar 2.4 Pengaruh nilai perbandingan air-semen pada kekuatan tekan 28 hari. Nilai rata-rata untuk beton yang mempunyai kandungan 1,5 sampai 2% udara untuk non air-entrained beton dan tidak lebih dari 5 sampai 6% untuk air-entrained beton... 5 Kurva-kurva tegangan-regangan tipikal untuk beton dalam tekan dibawah pembebanan jangka pendek... 6 Kurva-kurva tegangan-regangan untuk tingkat-tingkat kecepatan regangan dari pembebanan konsentris... 6 Perbandingan dari hasil-hasil percobaan untuk modulus keruntuhan dengan rumus peraturan ACI... 7 Gambar 2.5 Kurva tegangan-regangan untuk beton dalam tekan... 8 Gambar 2.6 Gambar 2.7 Perubahan dalam regangan dari suatu spesimen kering yang dibebani; t 0 adalah waktu penerapan beban... 10 Variasi dari koefisien rangkak sesuai dengan lamanya beban (untuk slump 10cm atau kurang, kelembaban 40%, pengeringan lengas dan beban pada umur 7 hari)... 11 Gambar 2.8 Hubungan cirian antara rangkak dan pemulihan... 12 Gambar 2.9 Variasi dari regangan susut standar sesuai dengan waktu setelah pengeringan lengas (untuk slump 4 inci atau kurang, 40% kelembaban relatif disekitarnya dan tebal terkecil dari batang 6 inci atau kurang setelah 7 hari pengeringan lengas)... 13 Gambar 2.10 Deformasi Elemen Struktur akibat Pembebanan Lentur 14 xiv Universitas Kristen Maranatha

Gambar 2.11 Momen Kurvatur pada Balok Beton... 14 Gambar 2.12 Parameter Waktu Getar Fundamental Efektif dari Kurva Pushover.. 21 Gambar 2.13 Perilaku Pasca Leleh Sistem Struktur... 24 Gambar 2.14 Skematik Prosedur Metode Koefisien Perpindahan... 25 Gambar 2.15 Titik Kinerja menurut Metode Spektrum Kapasitas... 26 Gambar 2.16 Parameter data Respons Spektrum Rencana... 26 Gambar 2.17 Variasi Pola Distribusi Pembebanan Lateral... 28 Gambar 2.18 Properti Sendi Plastis. 29 Gambar 2.19 Wilayah gempa indonesia dengan percepatan puncak batuan dasar dengan periode ulang 500 tahun... 34 Gambar 2.20 Respon Spektrum Gempa Rencana... 34 Gambar 3.1 Grafik Tegangan-Regangan Tulangan Baja.. 38 Gambar 3.2 Denah Struktur 39 Gambar 3.3 Tampak Samping Struktur..... 40 Gambar 3.4 Portal As-3. 40 Gambar 3.5 Diagram Alir Penelitian. 41 Gambar 3.6 Input Koordinat.. 42 Gambar 3.7 Definisi Material Untuk Balok.. 43 Gambar 3.8 Definisi Material Untuk Kolom. 43 Gambar 3.9 Modifikasi Stress-Strain Untuk Tulangan Tidak Sesuai Standar 44 Gambar 3.10 Modifikasi Stress-Strain Untuk Tulangan Standar 44 xv Universitas Kristen Maranatha

Gambar 3.11 Input Dimensi Penampang Untuk Balok 45 Gambar 3.12 Input Dimensi Penampang Untuk Kolom.. 45 Gambar 3.13 Input Dimensi Tebal Untuk Pelat... 46 Gambar 3.14 Input Perletakan. 46 Gambar 3.15 Input Beban SDL Pada Pelat. 47 Gambar 3.16 Input Beban Hidup Pada Pelat... 47 Gambar 3.17 Data Analisis Statik Nonlinear Untuk Beban Gravitasi 48 Gambar 3.18 Data Analisis Statik Nonlinear Untuk Beban Dorong.. 48 Gambar 3.19 Modifikasi Kontrol Beban... 48 Gambar 3.20 Modifikasi Result Saved... 49 Gambar 3.21 Parameter Nonlinear.. 49 Gambar 3.22 Data Penempatan Hinge untuk Balok 50 Gambar 3.23 Hinge Assignment Data untuk Balok 50 Gambar 3.24 Data Penempatan Hinge untuk Kolom... 50 Gambar 3.25 Hinge Assignment Data untuk Kolom... 51 Gambar 4.1 Kurva Kapasitas. 58 Gambar 4.2 Step 17 Tulangan Standar..... 59 Gambar 4.3 Step 17 Tulangan Non-Standar..... 59 Gambar 4.4 Step 112 Tulangan Standar....... 59 Gambar 4.5 Step 112 Tulangan Non-Standar...... 59 Gambar 4.6 Step 543 Tulangan Standar... 60 Gambar 4.7 Step 543 Tulangan Non-Standar.. 60 xvi Universitas Kristen Maranatha

Gambar 4.8 Step 586 Tulangan Standar... 61 Gambar 4.9 Step 543 Tulangan Non-Standar 61 Gambar 4.10 Balok B32 62 Gambar 4.11 Luas Tulangan Longitudinal Yang Dibutuhkan Untuk Balok B32.... 62 Gambar 4.12 Nilai Av/s untuk balok B32.... 62 Gambar 4.13 Perbandingan Momen Kurvatur.. 63 Gambar 4.14 Perbandingan Momen Kurvatur...... 64 Gambar 4.15 Perbandingan Momen Kurvatur... 65 Gambar 4.16 Perbandingan Momen Kurvatur... 65 Gambar 4.17 Kolom K11.... 66 Gambar 4.18 Luas Tulangan Longitudinal Yang Dibutuhkan Untuk Kolom K11........ 67 Gambar 4.19 Nilai Av/s Untuk Kolom K11.... 67 Gambar 4.20 Perbandingan Momen Kurvatur Kolom 68 Gambar 4.21 Perbandingan Kapasitas Kolom 69 Gambar L1.1 Model Portal Verifikasi... 75 Gambar L1.2 Reaksi Perletakan Pemodelan SAP2000... 84 Gambar L2.1 Step 1... 85 Gambar L2.2 Step 30..... 85 Gambar L2.3 Step 60...... 86 Gambar L2.4 Step 90... 86 Gambar L2.5 Step 120... 87 xvii Universitas Kristen Maranatha

Gambar L2.6 Step 150... 87 Gambar L2.7 Step 180... 88 Gambar L2.8 Step 210... 88 Gambar L2.9 Step 240... 89 Gambar L2.10 Step 270... 89 Gambar L2.11 Step 300... 90 Gambar L2.12 Step 330... 90 Gambar L2.13 Step 360... 91 Gambar L2.14 Step 390... 91 Gambar L2.15 Step 420... 92 Gambar L2.16 Step 450... 92 Gambar L2.17 Step 480.... 93 Gambar L2.18 Step 510.... 93 Gambar L2.19 Step 540...... 94 Gambar L2.20 Step 570...... 94 Gambar L2.21 Step 586... 95 Gambar L3.1 Step 1... 96 Gambar L3.2 Step 25. 96 Gambar L3.3 Step 50. 97 Gambar L3.4 Step 75..... 97 Gambar L3.5 Step 100.. 98 Gambar L3.6 Step 125.. 98 xviii Universitas Kristen Maranatha

Gambar L3.7 Step 150.. 99 Gambar L3.8 Step 175.. 99 Gambar L3.9 Step 200.... 100 Gambar L3.10 Step 225... 100 Gambar L3.11 Step 250... 101 Gambar L3.12 Step 275... 101 Gambar L3.13 Step 300... 102 Gambar L3.14 Step 325... 102 Gambar L3.15 Step 350... 103 Gambar L3.16 Step 375... 103 Gambar L3.17 Step 400... 104 Gambar L3.18 Step 425... 104 Gambar L3.19 Step 450... 105 Gambar L3.20 Step 475... 105 Gambar L3.21 Step 543... 106 xix Universitas Kristen Maranatha

DAFTAR TABEL Tabel 2.1 Sifat mekanis baja tulangan... 15 Tabel 2.2 Tingkat Kerusakan Struktur... 29 Tabel 2.3 Tabel 2.4 Tabel 2.5 Faktor Keutamaan I untuk berbagai kategori gedung dan bangunan... 30 Faktor daktilitas maksimum, faktor reduksi gempa maksimum, faktor tahanan lebih struktur dan faktor tahanan lebih total beberapa jenis sistem dan subsistem struktur gedung... 31 Koefisien ζ yang membatasi waktu getar alami fundamental struktur gedung... 35 Tabel 4.1 Periode Waktu Getar Struktur 55 Tabel 4.2 Berat dan Massa Struktur 53 Tabel 4.3 Verifikasi Berat Lantai 3 53 Tabel 4.4 Perhitungan Pembagian Gaya Gempa Tiap Lantai 54 Tabel 4.5 Perpindahan Lantai. 55 Tabel 4.6 Perhitungan T- Ray untuk arah X 56 Tabel 4.7 Perhitungan T- Ray untuk arah Y 56 Tabel 4.8 Perhitungan Kinerja Batas Layan Bangunan untuk arah X 57 Tabel 4.9 Perhitungan Kinerja Batas Layan Bangunan untuk arah Y 57 Tabel L1.1 Verifikasi Reaksi Perletakan.. 84 Tabel L4.1 Pre-Eleminary Design 109 xx Universitas Kristen Maranatha

DAFTAR NOTASI C 1 D E ζ Fy Fu h i Faktor Respons Gempa dinyatakan dalam percepatan gravitasi yang nilainya bergantung pada waktu getar alami struktur gedung dan kurvanya ditampilkan dalam Spektrum Respons Gempa Rencana Perpindahan titik acuan pada atap (meter) Modulus Elastisitas (MPa) Koefisien yang membatasi waktu getar alami fundamental struktur gedung Tegangan Leleh Baja Tulangan (MPa) Tegangan Putus Baja Tulangan (MPa) Tinggi lantai gedung ke-i (meter) I Faktor keutamaan gedung, faktor pengali dari pengaruh Gempa Rencana pada berbagai kateori gedung, untuk menyesuaikan perioda ulang gempa yang berkaitan dengan penyesuaian probabilitas dilampauinya pengaruh tersebut selama umur gedung itu penyesuaian umur gedung itu γ Berat jenis beton (kg/m 3 ) m Massa gedung (kg.det 2 /meter) m total Massa gedung total (kg.det 2 /meter) R Faktor reduksi gempa, rasio antara beban gempa maksimum akibat pengaruh gempa rencana pada struktur gedung elastik penuh dan beban gempa nominal akibat pengaruh gempa rencana pada struktur gedung daktail, bergantung pada faktor daktilitas struktur gedung tersebut; faktor reduksi gempa representatif struktur gedung tidak beraturan xxi Universitas Kristen Maranatha

T V W t Waktu getar alami struktur gedung dinyatakan dalam detik yang menentukan besarnya Faktor Respons Gempa struktur gedung yang kurvanya ditampilkan dalam Spektrum Respons gempa rencana (detik) Beban (gaya) geser dasar nominal statik ekuivalen akibat pengaruh Gempa Rencana yang bekerja di tingkat dasar struktur gedung beraturan dengan tingkat daktilitas umum, dihitung berdasarkan waktu getar alami fundamental struktur gedung beraturaan tersebut (kg) Massa gedung dikalikan gravitasi (kg) Δ δ y Perpindahan lantai (meter) Perpindahan atap saat leleh pertama (meter) δ u Paerpindahan atap saat kondisi ultimit (meter) xxii Universitas Kristen Maranatha

DAFTAR LAMPIRAN Lampiran I Verfikasi Software... 75 Lampiran II Step Analisis Pushover Tulangan Sesuai Standar.. 85 Lampiran III Step Analisis Pushover Tulangan Tidak Sesuai Standar 96 Lampiran IV Pre-Eleminiary Design.. 107 xxiii Universitas Kristen Maranatha