STUDI EKSPERIMENTAL VARIASI TULANGAN SENGKANG PADA KOLOM PERSEGI ABSTRAK

dokumen-dokumen yang mirip
STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM PERSEGI BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP ABSTRAK

STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM LINGKARAN BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP ABSTRAK

STUDI EKSPERIMENTAL EFEKTIVITAS PENGEKANGAN KOLOM LINGKARAN DENGAN MENGGUNAKAN PEN-BINDER ABSTRAK

STUDI EKSPERIMENTAL PENGGUNAAN FRP (FIBER REINFORCED POLYMER)TERHADAP PERKUATAN KOLOM BETON BERTULANG ABSTRAK

STUDI EKSPERIMENTAL PERBAIKAN KOLOM LINGKARAN BETON BERTULANG ABSTRAK

PERHITUNGAN DAN PENGGAMBARAN DIAGRAM INTERAKSI KOLOM BETON BERTULANG DENGAN PENAMPANG PERSEGI. Oleh : Ratna Eviantika. : Winarni Hadipratomo, Ir.

STUDI EKSPERIMENTAL PERBAIKAN KOLOM PERSEGI BETON BERTULANG ABSTRAK

STUDI EKSPERIMENTAL EFEKTIVITAS PENGEKANGAN KOLOM LINGKARAN DENGAN MENGGUNAKAN FRP (FIBER REINFORCED POLYMER) ABSTRAK

STUDI EKSPERIMENTAL PENGGUNAAN PEN- BINDER TERHADAP PERKUATAN KOLOM BETON BERTULANG ABSTRAK

DAFTAR ISI JUDUL PENGESAHAN PERNYATAAN BEBAS PLAGIASI ABSTRAK ABSTRACT KATA PENGANTAR

UNIVERSITAS KRISTEN MARANATHA FAKULTAS TEKNIK JURUSAN TEKNIK SIPIL BANDUNG

STRUKTUR BETON BERTULANG II

STUDI EKSPERIMENTAL PENGGUNAAN PORTLAND COMPOSITE CEMENT TERHADAP KUAT LENTUR BETON DENGAN f c = 40 MPa PADA BENDA UJI BALOK 600 X 150 X 150 mm 3

BAB II TINJAUAN PUSTAKA

STUDI ANALISIS PERTEMUAN BALOK KOLOM BERBENTUK T STRUKTUR RANGKA BETON BERTULANG DENGAN PEMODELAN STRUT-AND- TIE ABSTRAK

d b = Diameter nominal batang tulangan, kawat atau strand prategang D = Beban mati atau momen dan gaya dalam yang berhubungan dengan beban mati e = Ek

ANALISIS LENTUR DAN GESER BALOK PRACETAK DENGAN TULANGAN SENGKANG KHUSUS ABSTRAK

ANALISIS DAKTILITAS BALOK BETON BERTULANG

STUDI EKSPERIMENTAL PENGARUH PENGGUNAAN PS BALL SEBAGAI PENGGANTI PASIR TERHADAP KUAT LENTUR BETON

PENGARUH GAYA AKSIAL TERHADAP LUAS TULANGAN PENGEKANG KOLOM BETON BERTULANG PERSEGI ABSTRAK

STUDI EKSPERIMENTAL PENGARUH PENAMBAHAN SUPERPLASTICIZER TERHADAP KUAT LENTUR BETON RINGAN ALWA MUTU RENCANA f c = 35 MPa

PERILAKU KERUNTUHAN BALOK BETON BERTULANG TULANGAN GANDA ABSTRAK

PENGARUH JARAK SENGKANG TERHADAP KAPASITAS BEBAN AKSIAL MAKSIMUM KOLOM BETON BERPENAMPANG LINGKARAN DAN SEGI EMPAT

PEMODELAN NUMERIK METODE ELEMEN HINGGA NONLINIER STRUKTUR BALOK TINGGI BETON BERTULANG ABSTRAK

STUDI PERBANDINGAN ANALISIS PELAT KONVENSIONAL DAN PELAT PRACETAK ABSTRAK

TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG PERPUSTAKAAN PUSAT YSKI SEMARANG

TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG KANTOR PERPAJAKAN PUSAT KOTA SEMARANG

Universitas Sumatera Utara

1.2) Kolom Tampang L a) Kondisi Regangan Berimbang b) Kondisi Tekan Menentukan c) Kondisi Tarik Menentukan BAB III.

Kata Kunci : beton, baja tulangan, panjang lewatan, Sikadur -31 CF Normal

PERILAKU BALOK BERTULANG YANG DIBERI PERKUATAN GESER MENGGUNAKAN LEMBARAN WOVEN CARBON FIBER

LEMBAR PENGESAHAN Tugas Akhir Sarjana Strata Satu (S-1)

PERILAKU LENTUR KOLOM BETON PIPIH DENGAN TULANGAN BAMBU

1. PENDAHULUAN 1.1. BETON

STUDI EKSPERIMENTAL MATERIAL BAJA TULANGAN DARI BERBAGAI DISTRIBUTOR DI BANDUNG ABSTRAK

PERENCANAAN STRUKTUR GEDUNG ASRAMA MAHASISWA UNIVERSITAS DIPONEGORO SEMARANG

LEMBAR PENGESAHAN TUGAS AKHIR

DESAIN TAHAN GEMPA BETON BERTULANG PENAHAN MOMEN MENENGAH BERDASARKAN SNI BETON DAN SNI GEMPA

STUDI PERILAKU PENGARUH EFEK PENGEKANGAN PADA KOLOM CONCRETE FILLED STEEL TUBE AKIBAT PEMASANGAN CROSS TIE

BAB III LANDASAN TEORI. beban hidup dan beban mati pada lantai yang selanjutnya akan disalurkan ke

Studi Eksperimental Penggunaan Pen-Binder dan FRP sebagai Perkuatan Tulangan Tidak Standar pada Kolom Lingkaran

Perencanaan Kolom Beton Bertulang terhadap Kombinasi Lentur dan Beban Aksial. Struktur Beton 1

BAB III LANDASAN TEORI

PENGARUH JARAK SENGKANG BAJA DARI METODE JAKET BETON BERTULANGAN BAMBU PADA KOLOM BERTULANGAN RINGAN

PERENCANAAN STRUKTUR RANGKA BAJA BRESING TAHAN GEMPA

PENGUJIAN LENTUR BALOK BETON BERTULANG DENGAN MENGGUNAKAN MODIFIKASI ALAT UJI TEKAN

ANALISIS PENGARUH BENTUK SHEAR WALL TERHADAP PERILAKU GEDUNG BERTINGKAT TINGGI ABSTRAK

ANALISA DAN PENGUJIAN KEKUATAN BALOK BETON BERTULANG BERLUBANG PENAMPANG PERSEGI TUGAS AKHIR. Disusun oleh : Dosen Pembimbing

STUDI KUAT LENTUR BALOK DENGAN PENAMBAHAN GLENIUM ACE 8590

BAB I PENDAHULUAN Latar Belakang. Kolom memegang peranan penting dari suatu bangunan karena memikul

DAFTAR ISI KATA PENGANTAR DAFTAR TABEL DAFTAR GAMBAR DAFTAR LAMPIRAN DAFTAR NOTASI DAN SIMBOL

PERBAIKAN KOLOM LANGSING BETON BERTULANG MENGGUNAKAN FIBER GLASS JACKET DENGAN VARIASI TINGKAT KERUSAKAN

ANALISIS LENDUTAN SEKETIKA dan LENDUTAN JANGKA PANJANG PADA STRUKTUR BALOK. William Trisina NRP : Pembimbing : Daud Rahmat Wiyono, Ir.,M.Sc.

STUDI EKSPERIMENTAL KUAT LENTUR PADA BALOK BETON BERTULANG DENGAN PERKUATAN BAJA RINGAN PROFIL U TUGAS AKHIR. Disusun oleh : LOLIANDY

UJI EKSPERIMENTAL KEKUATAN DRAINASE TIPE U-DITCH PRACETAK

STUDI EKSPERIMENTAL PENGARUH CAMPURAN LIMBAH KULIT KERANG TERHADAP MUTU KUAT TEKAN BETON f c = 25 MPa DAN KETAHANANNYA TERHADAP REMBESAN AIR LAUT

PERANCANGAN STRUKTUR ATAS GEDUNG CONDOTEL MATARAM CITY YOGYAKARTA. Oleh : KEVIN IMMANUEL KUSUMA NPM. :

STUDI EKSPERIMENTAL KUAT LENTUR PADA BALOK BETON BERTULANG DENGAN PERKUATAN BAJA RINGAN PROFIL U DI DAERAH TARIK ANDREANUS MOOY TAMBUNAN

PERENCANAAN STRUKTUR UNIT GEDUNG A UNIVERSITAS IKIP VETERAN SEMARANG

SUB JURUSAN STRUKTUR DEPARTEMEN TEKNIK SIPIL FAKULTAS TEKNIK UNIVERSITAS SUMATERA UTARA MEDAN 2016

BAB 1. PENGENALAN BETON BERTULANG

PERENCANAAN GEDUNG BETON BERTULANG BERATURAN BERDASARKAN SNI DAN FEMA 450

PENGARUH VARIASI DIMENSI BENDA UJI TERHADAP KUAT LENTUR BALOK BETON BERTULANG

DESAIN BALOK ELEMEN LENTUR SESUAI SNI

BAB III LANDASAN TEORI. dibebani gaya tekan tertentu oleh mesin tekan.

TINJAUAN KUAT LENTUR BALOK BETON BERTULANG DENGAN PENAMBAHAN KAWAT YANG DIPASANG LONGITUDINAL DI BAGIAN TULANGAN TARIK.

TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG DEWAN KERAJINAN NASIONAL DAERAH (DEKRANASDA) JL. KOLONEL SUGIONO JEPARA

STUDI EKSPERIMEN KAPASITAS TARIK DAN LENTUR PENJEPIT CONFINEMENT KOLOM BETON

PENGARUH VARIASI LUAS PIPA PADA ELEMEN BALOK BETON BERTULANG TERHADAP KUAT LENTUR

III. METODE PENELITIAN

PERENCANAAN STRUKTUR GEDUNG RUSUNAWA UNIMUS

STUDI EKSPERIMENTAL PENGARUH BERBAGAI KADAR VISCOCRETE PADA BERBAGAI UMUR KUAT TEKAN BETON MUTU TINGGI f c = 45 MPa

L p. L r. L x L y L n. M c. M p. M g. M pr. M n M nc. M nx M ny M lx M ly M tx. xxi

PENGARUH TEBAL SELIMUT BETON TERHADAP KUAT LENTUR BALOK BETON BERTULANG

Henny Uliani NRP : Pembimbing Utama : Daud R. Wiyono, Ir., M.Sc Pembimbing Pendamping : Noek Sulandari, Ir., M.Sc

Naskah Publikasi. untuk memenuhi sebagian persyaratan mencapai derajat Sarjana-1 Teknik Sipil. diajukan oleh : BAMBANG SUTRISNO NIM : D

STRUKTUR BETON BERTULANG II

BAB III LANDASAN TEORI. silinde beton dapat digunakan rumus berikut: f c = (3.1)

BAB III LANDASAN TEORI

BAB III LANDASAN TEORI

DAFTAR ISI. Halaman Judul Pengesahan Persetujuan ABSTRAK ABSTRACT KATA PENGANTAR

STUDI PERILAKU MEKANIK KEKUATAN BETON RINGAN TERHADAP KUAT LENTUR BALOK

1 HALAMAN JUDUL TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG SEKOLAH MENENGAH PERTAMA TRI TUNGGAL SEMARANG

BAB 4 ANALISIS DATA DAN PEMBAHASAN

PERENCANAAN STRUKTUR GEDUNG PUSAT GROSIR BARANG SENI DI JALAN Dr. CIPTO SEMARANG

BAB 4 DATA, ANALISIS DATA DAN PEMBAHASAN

PERILAKU LENTUR BETON MUTU TINGGI YANG DIKEKANG DENGAN BAJA MUTU TINGGI

PERILAKU RUNTUH BALOK DENGAN TULANGAN TUNGGAL BAMBU TALI TUGAS AKHIR

DAFTAR NOTASI. = Luas efektif bidang geser dalam hubungan balok-kolom (mm²) = Luas penampang tiang pancang (mm²)

KEKUATAN SAMBUNGAN BALOK BETON BERTULANG DENGAN SIKADUR -31 CF NORMAL

3.4.2 Pemeriksaan Berat Jenis dan Penyerapan Air Agregat Halus Error! Bookmark not defined Kadar Lumpur dalam Agregat... Error!

PERKUATAN KOLOM BETON BERTULANG DENGAN GLASS FIBER JACKET UNTUK MENINGKATKAN KAPASITAS BEBAN AKSIAL (034S)

Kata kunci: daktilitas regangan, kapasitas aksial kolom, sengkang, kolom penampang pipih, Galvanised Welded Wire Fabric, diagram tegangan-regangan.

STUDI EKSPERIMENTAL PENGARUH PENYELIMUTAN BETON DENGAN LEMKRA FIRE PROOFING TERHADAP KUAT BETON AKIBAT PEMBAKARAN

Yogyakarta, Juni Penyusun

Desain Elemen Lentur Sesuai SNI

PERENCANAAN JEMBATAN KALI TUNTANG DESA PILANGWETAN KABUPATEN GROBOGAN

PERANCANGAN STRUKTUR ATAS GEDUNG TRANS NATIONAL CRIME CENTER MABES POLRI JAKARTA. Oleh : LEONARDO TRI PUTRA SIRAIT NPM.

PERHITUNGAN PLAT LANTAI (SLAB )

Struktur Beton Bertulang

Transkripsi:

STUDI EKSPERIMENTAL VARIASI TULANGAN SENGKANG PADA KOLOM PERSEGI Binsar Gandaria Layuk 0921038 Pembimbing: Dr. Anang Kristianto, S.T., M.T. ABSTRAK Indonesia merupakan negara yang terletak di daerah rawan bencana alam. Kondisi ini mengharuskan sistem struktur yang dibangun di Indonesia harus mengikuti peraturan bangunan tahan gempa. Salah satunya pada kolom, yang merupakan komponen sangat penting dalam menjamin suatu struktur agar tidak mengalami keruntuhan total. Hal ini memotivasi perlunya dilakukan penelitian mengenai studi eksperimental beberapa kombinasi tulangan pengekang pada kolom. Tujuan penelitian dalam Tugas Akhir ini adalah menganalisis perilaku deformasi, kapasitas aksial, serta pengamatan retak kolom beton persegi dengan berbagai variasi tulangan sengkang. Total jumlah benda uji berbentuk 6 buah kolom pendek dengan dimensi 170mm x 170mm dan tinggi 480mm, dengan penguraian dua buah untuk tulangan sengkang standar, dua buah sengkang penbinder, dan dua buah sengkang khusus. 9 buah silinder normal dengan dimensi diameter 150mm dan tinggi 300mm digunakan untuk pengujian kekuatan beton karakteristik. Penelitian dilakukan untuk kolom dengan mutu beton f c = 16MPa. Hasil dari penelitian menunjukkan terjadi penurunan nilai regangan pada kolom sengkang pen-binder sebesar 47,826% terhadap kolom sengkang standar dan peningkatan nilai regangan pada kolom sengkang khusus sebesar 43,478% terhadap kolom sengkang standar berdasarkan perilaku deformasi tegangan regangan dengan alat uji LVDT. Kapasitas aksial (Po) rata-rata sengkang penbinder mengalami peningkatan nilai terhadap sengkang standar sebesar 0,302% dan Po rata-rata sengkang khusus mengalami penurunan nilai terhadap sengkang standar sebesar 2,367%. Pola retak yang terjadi pada kolom sengkang standar memiliki pola retak halus pada bagian atas kolom yang tertekan, pada kolom sengkang pen-binder memiliki pola retak halus serta terkelupasnya selimut beton pada bagian sudut sisi kolom, dan pada kolom sengkang khusus memiliki banyak retak halus pada bagian sudut sisi kolom. Kata Kunci: kolom, deformasi, tegangan, regangan, sengkang standar, sengkang pen-binder, sengkang khusus, LVDT. ix

THE EXPERIMENTAL STUDY OF TRANSVERSAL REINFORCED OF RECTANGULAR CONCRETE COLUMN Binsar Gandaria Layuk NRP: 0921038 Supervisor: Dr. Anang Kristianto, S.T., M.T. ABSTRACT Indonesia is a located over prone to natural disasters. This condition requires the system structure that built in Indonesia should follow to regulations of earthquake resistant buildings. One of them is column, that is a very important component to ensure a structure that did not ended up having a total failure. It motivates the need of research about experimental study of a few combinations of transversal reinforced on column. The purpose of this study in this Final Assignment is to analyze the deformation, axial capacity, and the observation of cracking in rectangular column with transversal reinforced. The total of the test object are 6 short columns with 170mm x 170mm dimension and 48mm height, by dividing two for standard transversal reinforced, two for pen-binder transversal reinforced, and two for special transversal reinforced. 9 pieces of normal cylinder with dimension of 150mm diameter, and 300mm height, used for testing in concrete strength characteristic. This study was conducted to column with the concrete quality f c = 16MPa. The results of the study shows that there is a reduction in the value of the strain in the pen-binder transversal reinforced columns by 47,826% of the standard transversal reinforced column and the increasing value of the strain in special transversal reinforced column by 43,478% of the standard transversal reinforced column by the deformation of tension strain with LVDT. Average axial capacity (P0) of pen-binder transversal reinforced has increased value on standard transversal reinforced by 0,302% and average P0 of special transversal reinforced has decreased value on standard transversal reinforced by 2,367%. The cracks pattern that occurred on standard transversal reinforced column has a subtle crack pattern on the upper side of the pressed column, on the pen-binder transversal reinforced column has a subtle crack pattern and peeling over the concrete cover on the corner of the column, and on the special transversal reinforced column has many subtle crack on the corner of the column. Keywords: column, deformation, stress, strain, standard transversal reinforced, pen-binder transversal reinforced, special transversal reinforced, LVDT. x

DAFTAR ISI HALAMAN JUDUL... i LEMBAR PENGESAHAN... ii PERNYATAAN ORISINALITAS LAPORAN PENELITIAN... iii PERNYATAAN PUBLIKASI LAPORAN PENELITIAN... iv SURAT KETERANGAN TUGAS AKHIR... v SURAT KETERANGAN SELESAI TUGAS AKHIR... vi KATA PENGANTAR... vii ABSTRAK... ix ABSTRACT... x DAFTAR ISI... xi DAFTAR GAMBAR... xiii DAFTAR TABEL... xv DAFTAR NOTASI... xvi DAFTAR LAMPIRAN... xix BAB I PENDAHULUAN... 1 1.1 Latar Belakang... 1 1.2 Tujuan Penelitian... 2 1.3 Ruang Lingkup Penelitian... 2 1.4 Sistematika Penulisan... 2 BAB II TINJAUAN LITERATUR... 4 2.1 Struktur Beton Bertulang... 4 2.1.1 Bahan Penyusun Beton Bertulang... 4 2.1.1.1 Agregat... 4 2.1.1.2 Semen Portland... 7 2.1.1.3 Air... 8 2.1.1.4 Baja Tulangan... 9 2.1.2 Campuran Beton... 10 2.2 Kolom Beton Bertulang... 11 2.2.1 Penulangan Pada Kolom... 12 2.2.1.1 Tulangan Utama... 12 2.2.1.2 Tulangan Pengekang... 13 2.2.2 Kapasitas Kolom... 14 2.2.3 Keruntuhan Kolom... 15 2.2.4 Pengujian Kuat Tekan Beton... 20 2.3 Perkuatan Pada Kolom Beton Bertulang... 21 2.4 Kolom Persegi dengan Tulangan Sengkang Pen-binder... 23 2.5 Kolom Persegi dengan Tulangan Sengkang Khusus... 24 BAB III METODE PENELITIAN... 25 3.1 Diagram Alir Penelitian... 25 3.2 Rencana Benda Uji... 27 3.3 Material Penyusun Beton Bertulang... 28 3.3.1 Agregat... 28 3.3.2 Semen... 29 3.3.3 Baja Tulangan... 29 3.3.4 Perancangan Campuran Beton... 30 xi

3.4 Penentuan Dimensi Kolom... 30 3.5 Analisis Pendahuluan... 30 3.5.1 Penentuan Tulangan Utama... 30 3.5.2 Penentuan Tulangan Pengekang... 32 3.5.3 Kapasitas Kolom... 33 3.5.4 Kapasitas Kolom Sengkang Pen-binder... 37 3.6 Pembuatan Benda Uji... 38 3.7 Perawatan Benda Uji... 39 3.8 Setup Alat Pengujian... 39 3.9 Pengujian Kuat Tekan... 42 3.9.1 Benda Uji Silinder... 42 3.9.2 Benda Uji Kolom... 43 BAB IV ANALISIS DATA... 45 4.1 Kuat Tekan Kolom... 45 4.2 Pola Retak Kolom... 48 4.3 Hasil Uji Kolom Berdasarkan LVDT... 52 4.4 Regangan Pada Tulangan Kolom... 54 BAB V SIMPULAN DAN SARAN... 58 5.1 Simpulan... 58 5.2 Saran... 59 DAFTAR PUSTAKA... 60 LAMPIRAN... 62 xii

DAFTAR GAMBAR Gambar 2.1 (a) Agregat kasar; (b) Agregat halus... 5 Gambar 2.2 Semen portland... 7 Gambar 2.3 Baja tulangan... 9 Gambar 2.4 Bentuk kolom: a) kolom bulat tulangan spiral; (b) kolom segiempat; (c) kolom komposit bulat tulangan spiral; (d) kolom komposit segiempat... 12 Gambar 2.5 Regangan kolom... 16 Gambar 2.6 Distribusi gaya terhadap titik pada diagram interaksi... 16 Gambar 2.7 Hubungan tegangan regangan pada beton dan baja... 19 Gambar 2.8 Pen binder... 23 Gambar 2.9 Penampang atas kolom sengkang pen-binder... 24 Gambar 2.10 Penampang atas kolom sengkang khusus... 24 Gambar 3.1 Diagram alir... 26 Gambar 3.2 Gambar rencana benda uji... 27 Gambar 3.3 Pengujian agregat: a) berat jenis agregat kasar; (b) berat jenis agregat halus SSD; (c) bobot isi... 28 Gambar 3.4 Pengujian berat jenis semen... 29 Gambar 3.5 Hasil uji kuat tarik tulangan ulir D13... 29 Gambar 3.6 Pengujian kuat tarik tulangan ulir D13... 30 Gambar 3.7 Diagram interaksi kolom sengkang standar dan kolom sengkang pen-binder memakai software PCACOL... 35 Gambar 3.7 Diagram interaksi kolom sengkang khusus memakai software PCACOL... 37 Gambar 3.9 Proses pembuatan benda uji: a) pengadukan campuran beton; (b) persiapan tulangan dan bekisting; (c) pengujian slump; (d) benda uji kolom... 39 Gambar 3.10 Perawatan benda uji... 39 Gambar 3.11 Pemasangan dan pengecekan strain gauge pada tulangan... 40 Gambar 3.12 Pengecatan dan pemberian tanda garis pada benda uji... 40 Gambar 3.13 Proses capping; a) membungkus kolom dengan besi tipis dan lakban hitam; (b) mengisi belerang cair keatas permukaan kolom; (c) pengeringan belerang; (d) memastikan kolom telah rata dengan waterpass... 41 Gambar 3.14 Pemasangan dan letak LVDT pada benda uji... 41 Gambar 3.15 Pengujian kuat tekan beton silinder pada umur 21 hari... 42 Gambar 3.16 Pengujian kuat tekan beton silinder pada umur 28 hari... 43 Gambar 3.17 Hasil uji perangkat lunak... 44 Gambar 3.18 Pengujian kuat tekan kolom... 44 Gambar 4.1 Hasil pengujian kuat tekan kolom sengkang standar (135 o )... 46 Gambar 4.2 Hasil pengujian kuat tekan kolom sengkang standar pen-binder... 47 Gambar 4.3 Hasil pengujian kuat tekan kolom sengkang khusus... 47 Gambar 4.4 Pola retak kolom sengkang standar (135 o )... 48 Gambar 4.5 Pola retak kolom sengkang pen-binder... 49 Gambar 4.6 Pola retak kolom sengkang khusus... 50 xiii

Gambar 4.7 Hasil pengujian rata-rata kolom sengkang standar (135 o ) dengan alat LVDT... 52 Gambar 4.8 Hasil pengujian rata-rata kolom sengkang pen-binder dengan alat LVDT... 53 Gambar 4.9 Hasil pengujian rata-rata kolom sengkang khusus dengan alat LVDT... 53 Gambar 4.10Hasil pengujian rata-rata regangan tulangan pada kolom sengkang standar (135 o )... 55 Gambar 4.11Hasil pengujian rata-rata regangan tulangan pada kolom sengkang pen-binder... 55 Gambar 4.12Hasil pengujian rata-rata regangan tulangan pada kolom sengkang standar khusus2... 56 xiv

DAFTAR TABEL Tabel 2.1 Angka kekuatan beton dengan umur beton... 20 Tabel 3.1 Karakteristik agregat benda uji... 28 Tabel 3.2 Kuat tekan beton silinder... 43 Tabel 4.1 Hasil pengujian kuat tekan kolom... 45 Tabel 4.2 Tegangan regangan kolom... 54 xv

DAFTAR NOTASI a Jarak balok yang tertekan (mm) A Luas penampang (mm 2 ) A g Luas kotor penampang kolom (mm 2 ) A sd Luas tulangan baja tulangan yang digunakan (mm 2 ) A sv Luas tulangan pengekang (mm 2 ) A st Luas tulangan total yang digunakan (mm 2 ) A stmin Luas tulangan total minimum yang diperlukan (mm 2 ) b Lebar penampang melintang kolom (mm) B ba b c B j B j semen B j bulk hl B j bulk ks B k B p B pj c C c Berat agregat di dalam air (gr) Dimensi penampang inti kolom (mm) Berat benda uji kondisi ssd (gr) Berat jenis semen portland Berat jenis kering agregat halus Berat jenis kering agregat kasar Berat benda uji kondisi kering oven (gr) Berat piknometer diisi air (gr) Berat piknometer + benda uji ssd + air (gr) Jarak dari serat tekan terluar ke garis netral (mm) Sumbangan gaya tekan beton (kn) d Berat isi air pada temperatur ruang yang tetap, [ 1 ] gr/ml D a Bobot isi agregat (gr/cm 3 ) e Perbandingan antara momen nominal penampang dan kuat tekan aksial normal (mm) e b Perbandingan antara momen nominal penampang dan kuat tekan aksial nominal pada kondisi regangan seimbang (mm) E Modulus elastisitas (N/mm 2 ) E S F Modulus elastis baja (MPa) Besar gaya tekan (N) xvi

f c f cc f co f cc rata rata Kuat tekan beton karakteristik (MPa) Kuat tekan beton terkekang (MPa) Kuat tekan beton tidak terkekang (MPa) Kuat tekan beton terkekang aktual rata rata (MPa) f si F si f y f 1 f 1e h h c k 1 k 2 L M n M nb n P Pc Pst P 0 P 0 rata-rata P n P nb s S x s 1 t Tegangan pada setiap baris tulangan (Mpa) Sumbangan gaya masing masing baris tulangan (kn) Tegangan leleh tulangan (MPa) Tegangan leleh tulangan pengekang (MPa) Tegangan lateral ekuivalen (MPa) Tinggi penampang melintang kolom (mm) Lebar inti beton Koefisien yang menyatakan hubungan antara tegangan pengekang dan peningkatan kekuatan Koefisien yang menyatakan efisiensi tulangan pengekang Panjang awal (mm) Kekuatan momen nominal penampang (knm) Kekuatan momen nominal penampang pada kondisi seimbang (knm) Jumlah tulangan Tekanan (N) Kuat beban aksial akibat kontribusi beton (kn) Kuat beban aksial akibat kontribusi baja (kn) Kuat beban aksial nominal akibat beban aksial konsentrik (kn) Kuat beban aksial aktual rata rata (kn) Kuat beban aksial maksimum yang telah direduksi (kn) Kuat beban aksial nominal pada kondisi regangan seimbang (kn) Jarak tulangan pengekang sepanjang tinggi kolom (mm) Jarak spasi antar tulangan sengkang (mm) Jarak pusat antar tulangan utama (mm) Tinggi benda uji (mm) V Volume cawan silinder (cm 3 ) V 1 Volume awal semen Portland (ml) xvii

V 2 W Wa Z φ φp n(max) Volume akhir semen Portland (ml) Berat benda uji semen Portland (gr) Berat agregat (gr) Suatu nilai sembarang untuk membuat diagram interaksi Koefisien reduksi Kuat tekan rencana maksimum yang telah direduksi (kn) β 1 Rasio tinggi tekan ekivalen,a ke jarak garis netral, c. Ɛ Regangan ε cu ε si ε y ρs Batas regangan beton Regangan pada setiap baris tulangan Regangan leleh baja Rasio tulangan σ Tegangan (N/mm 2 ) ΔL Pertambahan panjang (mm) xviii

DAFTAR LAMPIRAN Lampiran 1 Pengujian Bahan Material... 62 Lampiran 2 Perancangan Campuran Beton... 68 Lampiran 3 Foto Proses Pengerjaan... 74 Lampiran 4 Hasil Uji Kuat Tekan Kolom... 81 xix