Kajian Pengaruh Perubahan Putaran Fan terhadap Pembuangan Panas pada Precooling Condenser

dokumen-dokumen yang mirip
BAB V ANALISA PERHITUNGAN DARI BEBERAPA ALAT. V.1 Hasil perhitungan beban pendingin dengan memakai TRACE 700

UNJUK KERJA PENGKONDISIAN UDARA MENGGUNAKAN HEAT PIPE PADA DUCTING DENGAN VARIASI LAJU ALIRAN MASSA UDARA

BAB II DASAR TEORI 0,93 1,28 78,09 75,53 20,95 23,14. Tabel 2.2 Kandungan uap air jenuh di udara berdasarkan temperatur per g/m 3

BAB II DASAR TEORI. BAB II Dasar Teori

Kajian Pengaruh Kecepatan Putar Kipas Kondenser Terhadap Konsumsi Energi Dan Kapasitas Pendinginan Mesin Tata Udara

PENGARUH LAJU ALIRAN UDARA TERHADAP KINERJA SISTEM REFRIGERASI PADA TATA UDARA SENTRAL. M. Nuriyadi ABSTRACT

APLIKASI MODUL EVAPORATIVE COOLING AKTIF PADA AC SPLIT 1 PK

BAB II DASAR TEORI. BAB II Dasar Teori. 2.1 AC Split

Pengaruh Debit Udara Kondenser terhadap Kinerja Mesin Tata Udara dengan Refrigeran R410a

Kampus Bina Widya Jl. HR. Soebrantas Km 12,5 Pekanbaru, Kode Pos Abstract

BAB II LANDASAN TEORI

ANALISIS ENERGI PENINGKATAN KINERJA MESIN PENDINGIN MENGGUNAKAN LIQUID-SUCTION SUBCOOLER DENGAN VARIASI TEMPERATUR LINGKUNGAN

BAB II LANDASAN TEORI. tropis dengan kondisi temperatur udara yang relatif tinggi/panas.

Simposium Nasional Teknologi Terapan (SNTT) 2013 ISSN X

BAB II TINJAUAN PUSTAKA

Pemanfaatan Air Kondensat Untuk Meningkatkan Unjuk Kerja Dan Efisiensi AC Split

EFEKTIVITAS PENGGUNAAN THERMOSTATIC EXPANTION VALVE PADA REFRIGERASI AC SPLIT. Harianto 1 dan Eka Yawara 2

BAB III METODOLOGI PENELITIAN Bahan Penelitian Pada penelitian ini refrigeran yang digunakan adalah Yescool TM R-134a.

Laporan Tugas Akhir BAB II TEORI DASAR

BAB II DASAR TEORI. Laporan Tugas Akhir. Gambar 2.1 Schematic Dispenser Air Minum pada Umumnya

BAB II TEORI DASAR. 2.1 Pengertian Sistem Tata Udara

BAB I PENDAHULUAN 1.1 Definisi Pengkondisian Udara

DISTRIBUSI KELEMBABAN UDARA DENGAN METODE PEMANAS 60, 70, 80, 90 WATT TERHADAP VARIASI KECEPATAN UDARA

Kampus Bina Widya Km 12,5 Simpang Baru Panam, Pekanbaru 28293, Indonesia 2 Jurusan Teknik Mesin, Fakultas Teknik, Universitas Bengkulu,

BAB II DASAR TEORI. 2.1 Pengertian Sistem Heat pump

BAB II LANDASAN TEORI

BAB 9. PENGKONDISIAN UDARA

Jurnal Ilmiah TEKNIK DESAIN MEKANIKA Vol. 5 No. 3, September 2016 (1-6)

BAB II LANDASAN TEORI

Potensi Air Kondensat Sebagai Media Pendingin Untuk Aplikasi Modul Evaporative Cooling Terhadap Performansi AC Split 1 PK

BAB III ANALISA DAN PEMBAHASAN

BAB II LANDASAN TEORI

PERBANDINGAN UNJUK KERJA FREON R-12 DAN R-134a TERHADAP VARIASI BEBAN PENDINGIN PADA SISTEM REFRIGERATOR 75 W

JTM Vol. 04, No. 1, Februari

BAB II DASAR TEORI. perpindahan kalor dari produk ke material tersebut.

KINERJA AIR CONDITONING HIBRIDA PADA LAJU ALIRAN AIR BERBEDA DENGAN KONDENSOR DUMMY TIPE HELICAL COIL (1/4", 6,7 m) SEBAGAI WATER HEATER

BAB II DASAR TEORI. 2.1 Sistem Refrigerasi Kompresi Uap

PERFORMANSI SISTEM REFRIGERASI HIBRIDA PERANGKAT PENGKONDISIAN UDARA MENGGUNAKAN REFRIGERAN HIDROKARBON SUBSITUSI R-22

BAB 5. HASIL DAN PEMBAHASAN

DAFTAR ISI. KATA PENGANTAR... i. ABSTRAK... iii. DAFTAR GAMBAR... viii. DAFTAR TABEL... x. DAFTAR NOTASI... xi Rumusan Masalah...

PENGARUH BEBAN PENDINGIN TERHADAP TEMPERATUR SISTEM PENDINGIN SIKLUS KOMPRESI UAP DENGAN PENAMBAHAN KONDENSOR DUMMY

PENGARUH LAJU ALIRAN AIR SISTEM EVAPORATIVE COOLING

TUGAS AKHIR EKSPERIMEN HEAT TRANSFER PADA DEHUMIDIFIER DENGAN AIR DAN COOLANT UNTUK MENURUNKAN KELEMBABAN UDARA PADA RUANG PENGHANGAT

BAB II LANDASAN TEORI

Studi Eksperimen Pemanfaatan Panas Buang Kondensor untuk Pemanas Air

ANALISIS PERFORMANSI MODEL PENGERING GABAH POMPA KALOR

KARAKTERISTIK MESIN PENGERING PAKAIAN MENGGUNAKAN AC (AIR CONDITIONER) DENGAN SIKLUS KOMPRESI UAP SISTEM UDARA TERBUKA

BAB II DASAR TEORI BAB II DASAR TEORI

BAB II LANDASAN TEORI

Perbandingan Unjuk Kerja Menara Pendingin Sistem Terbuka dan Tertutup

ANALISIS PERFORMANSI MINI FREEZER YANG DILENGKAPI DENGAN FLUIDA PENYIMPAN DINGIN (THERMAL STORAGE)

benar kering. Kandungan uap air dalam udara pada untuk suatu keperluan harus dibuang atau malah ditambahkan. Pada bagan psikometrik ada dua hal yang p

Analisis Beban Thermal Rancangan Mesin Es Puter Dengan Kompresor ½ PK Untuk Skala Industri Rumah Tangga

PEMBUATAN ALAT PENGERING SERBUK TEMBAGA DENGAN MENGGUNAKAN SISTEM REFRIGERASI KOMPRESI UAP

PENDAHULUAN TINJAUAN PUSTAKA

PENGURANGAN KELEMBABAN UDARA MENGGUNAKAN LARUTAN CALSIUM CHLORIDE (CACL2) PADA WAKTU SIANG HARI DENGAN VARIASI SPRAYING NOZZLE

BAB II TINJAUAN PUSTAKA

Kaji Eksperimental Pemanfaatan Panas Kondenser pada Sistem Vacuum Drying untuk Produk Kentang

KAJI EKSPERIMENTAL KARAKTERISTIK PIPA KAPILER DAN KATUP EKSPANSI TERMOSTATIK PADA SISTEM PENDINGIN WATER-CHILLER

ANALISA AUDIT KONSUMSI ENERGI SISTEM HVAC (HEATING, VENTILASI, AIR CONDITIONING) DI TERMINAL 1A, 1B, DAN 1C BANDARA SOEKARNO-HATTA

STUDI EKSPERIMENTAL PERFORMANSI COOLING PAD BERBAHAN SUMBU KOMPOR DENGAN PENAMBAHAN VARIASI DUCTING BERBENTUK SILINDER DAN BALOK ABSTRAK

PERANCANGAN KONDENSOR MESIN PENGERING PAKAIAN MENGGUNAKAN AIR CONDITIONER ½ PK SIKLUS UDARA TERTUTUP

ANALISA TERMODINAMIKA LAJU PERPINDAHAN PANAS DAN PENGERINGAN PADA MESIN PENGERING BERBAHAN BAKAR GAS DENGAN VARIABEL TEMPERATUR LINGKUNGAN

JURNAL TEKNIK ITS Vol. 5, No. 2, (2016) ISSN: ( Print)

BAB II DASAR TEORI BAB II DASAR TEORI

Termodinamika II FST USD Jogja. TERMODINAMIKA II Semester Genap TA 2007/2008

= Perubahan temperatur yang terjadi [K]

UJI PERFORMANSI SIMULATOR ALAT PENGKONDISI UDARA JENIS AIR-WATER SYSTEM

BAB III DASAR PERANCANGAN INSTALASI AIR CONDITIONING

Studi Eksperimental Pengaruh Aplikasi Lshx Terhadap Kinerja Sistem Refrigerasi Dengan Refrigeran R404A

BAB II DASAR TEORI Prinsip Kerja Mesin Refrigerasi Kompresi Uap

PROGRAM PENDIDIKAN SARJANA EKSTENSI DEPARTEMEN TEKNIK MESIN FAKULTAS TEKNIK UNIVERSITAS SUMATERA UTARA MEDAN 2016

Salah satu jenis pengering udara adalah regenerative desiccant air dryer. Gambar 2.2 merupakan salah satu contoh dari alat pengering udara jenis

PERHITUNGAN KEBUTUHAN COOLING TOWER PADA RANCANG BANGUN UNTAI UJI SISTEM KENDALI REAKTOR RISET

ALAT VISUALISASI PROSES PENGKONDISIAN UDARA

Kata kunci: dehumidifikasi, desalinasi, humidifikasi, pompa kalor C.2

EFEK RASIO TEKANAN KOMPRESOR TERHADAP UNJUK KERJA SISTEM REFRIGERASI R 141B

Komparasi Katup Ekspansi Termostatik dan Pipa Kapiler terhadap Temperatur dan Tekanan Mesin Pendingin

PENGARUH DEBIT ALIRAN AIR TERHADAP PROSES PENDINGINAN PADA MINI CHILLER

ANALISA KINERJA MESIN REFRIGERASI RUMAH TANGGA DENGAN VARIASI REFRIGERAN

SILABUS MATA KULIAH D4 REFRIGERASI DASAR KURIKULUM 2011 tahun ajaran 2010/2011. Materi Tujuan Ket.

BAB III PERANCANGAN SISTEM

BAB II TINJAUAN PUSTAKA

Perencanaan Ulang Sistem Pengkondisian Udara Pada lantai 1 dan 2 Gedung Surabaya Suite Hotel Di Surabaya

Penggunaan Refrigeran R22 dan R134a pada Mesin Pendingin. Galuh Renggani Wilis, ST.,MT

LAPORAN TUGAS AKHIR REDESIGN OF AIR CONDITIONING TEST-BED FOR ENERGY CONVERSION LABORARORY

PENGARUH PENAMBAHAN KONDENSOR DUMMY (TIPE HELICAL COIL, TROMBONE COIL DAN MULTI HELICAL COIL) TERHADAP TEMPERATUR RUANGAN DAN TEMPERATUR AIR PANAS

Analisa performansi cooling pad dengan penambahan saluran berbentuk silinder dan balok

BAB 3 METODE PENGUJIAN DAN PENGAMBILAN DATA

Desain Perancangan dan Pemilihan Pipa Kapiler dan Evaporator, Chiller dengan kompresor low temp. 3Hp

EFEK PERUBAHAN LAJU ALIRAN MASSA AIR PENDINGIN PADA KONDENSOR TERHADAP KINERJA MESIN REFRIGERASI FOCUS 808

BAB II DASAR TEORI. Gambar 2.1 diagram blok siklus Sistem Refrigerasi Kompresi Uap

SISTEM PENGKONDISIAN UDARA (AC)

PENGARUH ALAT EKSPANSI TERHADAP TEMPERATUR DAN TEKANAN PADA MESIN PENDINGIN SIKLUS KOMPRESI UAP

OPTIMASI SISTEM PENGKONDISIAN UDARA PADA KERETA REL LISTRIK

BAB V PENUTUP. Dari hasil penyelesaian tugas akhir dapat ditarik kesimpulan sebagai berikut :

PENDINGINAN KOMPRESI UAP

Ahmad Farid* dan Moh. Edi.S. Iman Program Studi Teknik Mesin, Universitas Pancasakti Tegal Jl. Halmahera km 1, Tegal *

BAB 6. RENCANA TAHAPAN BERIKUTNYA

MESIN PENGERING HANDUK DENGAN ENERGI LISTRIK

Transkripsi:

ProsidingNasionalRekayasaTeknologiIndustridanInformasi XIII Tahun 2018 (ReTII) November2018, pp. 357~361 ISSN: 1907-5995 357 Kajian Pengaruh Perubahan Putaran Fan terhadap Pembuangan Panas pada Precooling Condenser Susilawati 1, Tito Riyanto 1 1 Jurusan Teknik Refrigerasi dan Tata Udara, Politeknik Negeri Bandung Korespondensi susilawati@polban.ac.id; Abstrak Proses pemanasan berperan dalam meningkatkan temperatur udara kering (T DB) tanpa ada perubahan kadar uap air di udara. Proses tersebut terjadi karena udara melewati koil pemanas atau heater.fan digunakan untuk mengalirkan udara melalui koil pemanas, tujuannya adalah untuk mempercepat proses perpindahan panas antara udara dan koil pemanas.precooling condenser digunakan untuk membuang sebagian panas ke lingkungan dalam sistem dehumidifikasi mekanik. Pada 0% putaran fan temperatur udara kering (T DB) masuk dan keluarprecooling condenser bernilai 26,9 C, 72% RH, sedangkan pada 100% putaran fan temperatur udara kering (T DB) masuk dan keluarprecooling condenser masing-masingbernilai28,3 C, 66 % RHdan 28,3 C, 49%. Kapasitas penyerapan panas sensibel udara keluar precooling condenser meningkat hingga 1,75 kali lebih besar dari udara masukan. Kata Kunci : Pengering, Precooling Condenser, dan Kapasitas Penyerapan Panas. Abstract The heating process plays a role in increasing the dry air temperature (TDB) without any change in the water in the air. This process occurs because air passes through a heating coil or heater. Fan is used to flow air through the heating coil, the goal is to accelerate the process of heat transfer between air and heating coil. Recooling condenser is used to remove some of the heat into the environment in a mechanical dehumidification system. At 0% fan rotation dry air temperature (TDB) entering and exiting the cooling condenser is 26.9 C, 72% RH, while at 100% the fan rotation of the dry air temperature (TDB) enters and exits precooling condenser each rated 28.3 C, 66% RH and 28.3 C, 49%. The sensible heat absorption capacity of the outgoing air precooling condenser increases to 1.75 times greater than the input air Keyword : Dehumidifier, Precooling Condenser, and Heat Absorption Capacity. 1. PENDAHULUAN Pengeringan atau dehumidifikasi adalah proses menurunkan kadar uap air dalam udara. Pengeringan ini banyak dijumpai dalam proses pengolahan produk baik pangan, sandang dan papan. Proses pengeringan diperlukan pada bahan pangan untuk menjaga kualitas bahan sebelum diolah dari kontaminasi bakteri dan jamur. Industri pemintalan benang pun memerlukan proses yang diatur temperatur dan kelembabannya sehingga benang dapat terurai dengan baik. Begitupula untuk bahan yang mudah korosi, pengeringan diperlukan untuk mencegah korosi. Dengan proses dehumidifikasi dapat menguranagi kelembaban relatif dari sekitar 90% hingga 60% dan pengeringan dengan dehumidifier lebih besar 1,5 kali dari pengeringan biasa. [1] Dehumidifikasi mekanik merupakan proses pengeringan dengan terlebih dahulu mendinginkan udara kemudian memanaskan udara pada proses kondensasi. Pada mulanya udara akan diinginkan melalui evaporator dan menghasilkan udara dengan temperatur rendah dan kandungan uap air yang rendah. Kemudian udara dialirkan melalui kompresor dan kondenser untuk menyerap uap air lebih besar. Beberapa material atau proses, sensitif terhadap temperatur tinggi, untuk mengatasinya maka proses kondensasi di kondensor akan dibagi menjadi dua yaitu melalui primary dan precooling condenser sehingga temperatur keluar tidak akan jauh berbeda dengan temperatur masuk [2]. Metode dehumidifikasi dengan proses precooling telah dilakukan oleh banyak peneliti, salah satunya Khan dan Zubair (2000) yang memperoleh hasil degan menggunkana precooling dapat meningkatkan kinerja mesin sebanyak 7.5% [3]. Dan pngaruh penerunan putaran kecepatan putar kipas kondenser menyebabkan naiknya temperatur udara keluaran kondenser, naiknya konsumsi daya pada kompresor, dan turunnya kapasitas pendinginan mesin tata udara [4]. Prosiding homepage: http://journalsttnas.ac.id/ ReTII/

358 ISSN:1907-5995 Penelitian ini menganalisis perubahan putaran fan terhadap pembuangan panas precooling condenser pada sistem dehumidifikasi mekanik sehingga diperoleh nilai temperatur udara kering (T DB) udara keluaran menjadi bervariasi yang berdampak pada perubahan kelembaban relatif (RH), dan kapasitas penyerapan panas. 2. METODE PENELITIAN Pada penelitian ini dilakukan studi eksperimen terhadap mesin tata udara berkapasitas 5000 Btu/h dengan penambahan precooling condenser yang kapasitasnya setengah kali kapasitas pembuangan panas pada reheating condenser. Pada tahap pertama, dilakukan eksperimen dengan mengubah-ubah putaran fan precooling condenser. Kecepatan putaran fan diatur dari 0% hingga 100% secara manual menggunakan potensiometer. Skema gambar sistem dehumidifikasi mekanik yang diuji dijelaskan melalui Gambar 1. Gambar 1. Sistem dehumidifikasi mekanik Keterangan : a = Entering air b = Evaporator c = Kompresor d = PipaKapiler e = Precooling Condenser f = Reheating Condenser g = Sentrifugal Fan h = Supply Air i = Hand Valve 1 = BakDrain 2 = Ducting Polyurethane Diameter 2 cm 3 = Axial Fan Udara masuk melalui saluran masukan precooling condenser (e). Hal ini bertujuan untuk mempercepat dan memperluas perpindahan panas antara udara dengan koil pemanas digunakan fan axial untuk mengalirkan udara. Temperatur udara kering (T DB) dan kelembaban relatif (RH) sisi masukan dan keluaran udara pada precooling condenser diukur menggunakan thermo-hygro meter. Adapun tegangan dan arus pada sistem diukur menggunakan voltmeter dan ampermeter. Dan kecepatan udara pada precooling condenser diukur menggunakan anemometer. Pengujian performansi precooling condenser sisi udara meliputi analisis psikrometrik untuk menghitung besarnya laju energi proses pemanasan pada precooling condenser, serta persentase kenaikan kapasitas penyerapan panas sensibel. Laju energi panaas yang dibuang [5] dapat diperoleh dengan persamaan (1) sehingga diperoleh persentase kenaikan kapasitas panas sensibel. Laju Energi Panas yang dibuang oleh precooling condenser: = ṁ a (h 4- h 3)... (1) dengan = Besarnya laju energi panas sensibel yang dilepas oleh precooling condenser [kw] ReTII November2018 :357 361

ReTII ISSN: 1907-5995 359 ṁ a = Laju aliran massa udara kering [ ] h 4 = Entalpi udara keluaran [ ] h 3 = Entalpi udara masukan [ ] Sehingga persentase kenaikan penyerapan panas sensibel dapat diperoleh: δ S = ( ) (2) 100% ( ) dengan δ S = Persentase kenaikan penyerapan panas maksimum [%] = Temperatur udara kering masuk pengaruh putaran fan precooling condenser [ C] = Temperatur udara kering keluar pengaruh putaran fan precooling condenser (T WB masuk) [ C] = Temperatur udara kering masuk yang tidak dikondisikan [ C] = Temperatur udara kering keluar yang tidak dikondisikan (T WB masuk) [ C] f.% = Putaran fan precooling condenser 3. HASIL DAN PEMBAHASAN Data pengukuran dapat dilihat melalui Tabel 1. Tabel 1. Data Pengukuran Putaran fan Entering Leaving Kenaikan penyerapan panas sensibel (%) Tdb ( 0 C) Twb ( 0 C) Tdb ( 0 C) Twb ( 0 C) (%) 0 26,9 23,02 26,9 23,02 100 25 27,7 23,29 31,8 24,13 174 50 27,8 22,98 32,2 24,08 168 75 27,9 22,98 32,4 24,08 169 100 28,3 23,36 33 24,34 173 Grafik kecepatan in dan out fan precooling condenser terhadap waktu untuk setiap persentase putaran ditunjukkan melalui Gambar 2 dan Gambar 3. Gambar 2.Grafik kecepatan in precooling condenser terhadap waktu Gambar 3.Grafik kecepatan out precooling condenser terhadap waktu Kajian Perubahan Putaran Fan terhadap Pembuangan Panas pada Precooling Condenser (Susilawati)

360 ISSN:1907-5995 Besarnya nilai pembuangan panas pada precooling condenser dalam sistem ditentukan oleh perubahan putaran fan.grafik laju energi precooling condenser setiap persentase putaran fan ditunjukkan melalui Gambar 4. Gambar 4.Grafik laju energi panas condenser terhadap putaran fan Pada Gambar 4 Laju energy precooling condenser pada system mengalami kenaikan ketika putaran fan semakin tinggi. Pada persentase 0%, 25%, 50%, 75%, dan 100% putaran fan masing-masing bernilai 0 W, 783 W, 872 W, 920 W dan1.153 W. Persentase kenaikan penyerapan panas sensibel maksimum oleh udara keluaran pengaruh putaran fan precooling condenser terhadap udara yang masukan mengalami kenaikan yang ditunjukkan melalui Gambar 5. Gambar 5.Grafik kenaikan kapasitas penyerapan panas terhadap putaran fan Nilai persentase kapasitas penyerapan panas sensibel pada persentase 0%, 25%, 50%, 75%, dan 100% putaran fan masing-masing bernilai 100%, 174%, 168%, 169%, dan 175%. Artinya, penyerapan panas sensibel pada putaran fan maksimum oleh udara keluaran mencapai 1,75 kali lebih besar dari udar masukan precooling condenser. 4. KESIMPULAN Hasil penelitian dapat memperoleh kesimpulan sebagai berikut. 1. Pembuangan panas terbesar pada saat 100% putaran fan dengan nilai panas yang dibuang oleh precooling condenser mencapai 1.153 W. 2. Pengaruh persentase putaran fan terhadap precooling condenser berdampak pada kenaikan kapasitas penyerapan panas sensibel. Pada 100% putaran fan kemampuan penyerapan panas udara keluaran mencapai 1,75 kali lebih besar dari pada udara masukan pada precooling condenser. UCAPAN TERIMA KASIH Ucapan terima kasih disampaikan kepada Unit Penelitian dan Pengabdian kepada Masyarakat Politeknik Negeri Bandung yang telah membantu pembiayaan penelitian ini. ReTII November2018 :357 361

ReTII ISSN: 1907-5995 361 DAFTAR PUSTAKA [1] Lecoq L, Derens E, Flick D, Laguerre O. Influence of air dehumidification on water evaporation in a food plant Elsevier International Journal of Refrigeration. 2017; 74; 435-449 [2] ASHRAE, ASHRAE Handbook of Fundamental, American Society of Heating, Refrigerating, and Airconditioning Engineers, Atlanta, 2008: 24.2 [3] Khan, J.R., Zubair, S.M., 2000. Design and rating of dedicated mechanical subcooling vapor-compression refrigeration systems. Proc. IMechEeJ. Power Energy 214 (A5), 455-471 [4] Susillawati, Setiawan A, Kajian pengaruh kecepatan putar kipas kondenser terhadap konsumsi energi dan kapasitas pendinginan mesin tata udara. Prosiding Nasional Rekayasa Teknologi Industri dan Informasi XII Tahun 2017 [5] Pita Edward.G. Air Conditioning Principles and Systems Fourth Edition.London: Prentice-Hall. 2002: 39 Kajian Perubahan Putaran Fan terhadap Pembuangan Panas pada Precooling Condenser (Susilawati)