1 Makalah Seminar Tugas Akhir ANALISA PENEMPATAN KAPASITOR BANK UNTUK PERHITUNGAN DROP VOLTAGE PADA FEEDER BATANG 0 TAHUN 0-06 DENGAN SOFTWARE ETAP Sigit Wisnu Habsoro, Agung Nugroho, Bambang Winardi Jurusan Teknik Elektro Fakultas Teknik Universitas Diponegoro Jl. Prof Soedarto SH Tembalang, Semarang 5075 Abstract - Load growth in distribution system increase steadily. This load growth is followed by increased demand for reactive power supply due to increasing load is inductive. If a network does not have a reactive power source in around load area then all the needs of reactive load borne by the generator so that reactive current will flow to the network resulting in decreased power factor, voltage drop, and power losses. One way to improve power factor and voltage is placing the optimal capacitor value in the right location and strategic. This problem refers to the areas that need to UPJ Batang the addition of new capacitor. The addition of a new capacitor on feeder-feeder at the substation (GI) is useful to help the performance of the distribution system if the other capacitors in GI in a UPJ was not able to serve and supply the load due to the large voltage drop. In these conditions must be anticipated by PT. PLN Persero order to distribute the electrical energy can be channeled in sufficient number and placement of the new capacitor can really help The supply load capacitors in the pre-existing GI in the UPJ Batang. In this final project, using a model of the load forecasting assumptions. Modeling arranged simply by considering the availability of data, is used to compile and load forecasting needs 5 years to come up with assumptions. Software load forecasting model of assumptions made by the program ETAP With the draw single line diagram of the existing models, it can be analyzed using software ETAP by considering the results for the voltage drop feeder Batang 0 and the strategic placement of capacitors. Software boosters to help the capacitor placement optimization is to use a combination of fuzzy logic and genetic algorithms. Keywords : the placement of the new capacitor, load forecasting assumptions, ETAP 7.0.0, and drop voltage I. PENDAHULUAN Pertumbuhan beban ini diikuti dengan peningkatan permintaan suplai daya reaktif akibat beban yang bersifat induktif meningkat. Jika suatu jaringan tidak memiliki sumber daya reaktif di daerah sekitar beban maka semua kebutuhan beban reaktifnya dipikul oleh generator sehingga akan mengalir arus reaktif pada jaringan yang mengakibatkan drop tegangan. Namun adalah suatu hal yang sulit untuk mempertahankan tegangan konstan pada sistem distribusi karena drop tegangan akan terjadi pada semua bagian sistem dan akan berubah sesuai dengan adanya perubahan beban dan variasi beban. Salah satu cara untuk memperbaiki faktor daya dan tegangan adalah dengan menempatkan nilai kapasitor yang optimal di lokasi yang tepat pada sistem distribusi. Kapasitor dipasang di lokasi strategis untuk mempertahankan drop tegangan dalam batas yang diijinkan. Pada Tugas Akhir ini, menggunakan model asumsi peramalan beban. Pemodelan yang disusun secara sederhana dengan mempertimbangkan ketersediaan data yang ada, digunakan untuk menyusun dan meramalkan kebutuhan beban 5 tahun yang akan datang dengan asumsi. Software model asumsi peramalan beban dibuat dengan program ETAP Dengan di gambarkan single line diagram dari model eksisting tersebut, maka dapat dianalisa menggunakan software ETAP dengan mempertimbangkan hasil drop voltage untuk feeder Batang 0 dan penempatan kapasitor yang strategis. Software pedukung untuk membantu optimasi penempatan kapasitor adalah dengan menggunakan kombinasi logika fuzzy dan algoritma genetika.. Tujuan Tujuan pembuatan tugas akhir ini adalah untuk:. Menentukan letak dan nilai optimal kapasitor untuk memperbaiki drop tegangan pada sistem jaringan distribusi sesuai dengan batas yang diijinkan.. Membandingkan pengaruh yang terjadi dalam sistem jaringan distribusi sebelum dan sesudah penempatan kapasitor..3 Pembatasan Masalah Untuk menyederhanakan permasalahan dalam Tugas Akhir ini maka diberikan batasan - batasan sebagai berikut :
2 . Tugas akhir tidak aplikasi secara langsung tetapi hanya dalam bentuk simulasi.. Software yang digunakan dalam tugas akhir ini adalah ETAP dan Matlab 7.6 (008b). 3. Metode Logika Fuzzy dan Algoritma Genetika yang digunakan untuk optimasi penempatan kapasitor adalah hanya sebagai software pembantu. 4. Model sistem yang digunakan untuk pengujian adalah bus-bus pada feeder utama Batang 0 tahun Metode penyelesaian aliran daya menggunakan metode Newton-Rhapson dan kondisi sistem dianggap seimbang (balance system). 6. Penempatan lokasi kapasitor hanya bisa dipasang di salah satu bus saja. II. DASAR TEORI. Sistem Jaringan Distribusi Ada tiga bagian penting dalam proses penyaluran tenaga listrik, yaitu: Pembangkitan, Penyaluran (transmisi) dan distribusi seperti pada gambar berikut : yang terjual ke pelanggan listrik. Rugi-rugi daya merupakan sifat yang tidak dapat dihindari, tetapi hanya dapat diminimalkan...3 Dasar Pengaturan Tegangan Meskipun telah ditetapkan di dalam PUIL 987 bahwa drop tegangan yang dapat ditoleransi adalah sebesar 5%. Pada kenyataannya nilai tersebut amat sulit diwujudkan karena drop tegangan terjadi di semua bagian sistem dan akan berubah dengan adanya perubahan beban.. Kapasitor.. Kapasitor Shunt (Paralel) Kapasitor ini terhubung paralel pada jaringan maupun langsung pada beban, dengan tujuan untuk perbaikan faktor daya, sebagai pengatur tegangan maupun untuk mengurangi kerugian daya dan drop tegangan pada jaringan. Gambar. Rangkaian ekivalen saluran Gambar 3. Diagram vektor pada rangkaian pada faktor daya lagging tanpa kapasitor shunt Gambar. Tiga komponen utama dalam penyaluran tenaga listrik.. Jaringan Pada Sistem Distribusi Primer Jaringan Pada Sistem Distribusi tegangan menengah (Primer, 0 KV) dapat dibagi menjadi lima model, yaitu Jaringan Radial, Jaringan hantaran penghubung (Tie Line), Jaringan Lingkaran (Loop), Jaringan Spindel dan Sistem Gugus atau Kluster... Rugi Rugi Jaringan Jatuh tegangan merupakan penurunan tegangan dimulai dari penyulang sampai sepanjang saluran jaringan tegangan menengah. Fenomena tersebut disebabkan kawat saluran yang mempunyai nilai resistansi, induktansi dan kapasitansi sepanjang saluran, maka akan terjadi penurunan tegangan. Sedangkan rugi daya adalah selisih antara daya yang dibangkitkan atau dialirkan dari Gardu Induk dengan daya Gambar 4. Diagram vektor pada rangkaian pada faktor daya lagging dengan kapasitor shunt Kapasitor shunt mensuplai daya reaktif atau arus untuk menetralkan komponen keluaran antar phasa dari arus yang diperlukan oleh beban induktif. Penurunan tegangan pada penyulang, atau pada saluran transmisi yang pendek dengan faktor daya yang ketinggalan dapat dihitung sebagai berikut : VD = I R + I X (.) Dimana, VD = Penurunan tegangan (V) R = Resistansi total pada penyulang (ohm) X L = Reaktansi induktif total pada penyulang (ohm)
3 I R = Komponen daya nyata dari arus (A) I X = Komponen reaktif arus tertinggal (A) Ketika kapasitor ditempatkan pada akhir saluran, resultan drop tegangannya dapat dihitung : VD = I R + I X I X (.) Dimana, I C = komponen reaktif dari arus yang mendahului. Perbedaan antara penurunan tegangan yang dihitung berdasarkan persamaan (.) dan (.) adalah kenaikan tegangan pada pemasangan kapasitor yang dapat ditunjukkan sebagai berikut : VR = I X (.3).3 Peramalan Beban Energi Listrik Peramalan Beban Energi Listrik sangat diperlukan untuk memperkirakan kebutuhan energi listrik beberapa tahun yang akan datang. Peramalan pada dasarnya merupakan suatu prakiraan mengenai terjadinya suatu kejadian di masa yang akan datang. Data yang mendasari adanya peramalan adalah Data Pengusahaan..4 Model Peramalan Beban Model yang dipakai adalah asumsi penambahan beban. Model yang disusun peramalan beban dimana pertambahan prosentae beban pada trafo bertambah tiap tahun secara merata seiring dengan naiknya permintaan penggunaan energi tenaga listrik berdasarkan kenaikan rata-rata daya yang tersambung pada 5 tahun sebelumnya..5 Software ETAP Software ETAP atau Power Satation adalah suatu program atau perangkat lunak yang digunakan untuk menyelesaikan permasalahan yang berhubungan dengan sistem ketenagalistrikan. Dengan menggunakan software Etap dapat memodelkan analisis aliran daya (Load Flow), kita dapat menghitung aliran daya, tegangan pada sistem tenaga, dan lain-lain. Dalam penggunaan perangkat lunak ini secara mudah sehingga didapatkan nilai result yang akurat dibandingkan dengan menghitung manual. III. METODE PENELITIAN Gambar 5. Diagram Alir Penyusunan Laporan Tugas Akhir 3. Metode Pengumpulan Data Metode pengumpulan data adalah proses dalam pencarian data. Dalam penelitian ini pengunpulan data dilakukan dari survey data ke PT. PLN APJ yang menyediakan data-data untuk analisis penyaluran tenaga listrik Gardu Induk Batang. Tabel. Daftar Data yang Dibutuhkan No Instansi Data yang Dibutuhkan PT PLN APJ Data Pengusahaan APJ Jaringan Eksisting Gardu Induk Batang Data Single line diagram Dalam pengumpulan data tersebut diarahkan ke obyek penelitian yaitu Gardu Induk yang menyuplai di wilayah APJ. Data dari PLN adalah data teknis kelistrikan PT PLN APJ. 3. Metode Pengolahan Data Setelah data-data diperoleh langkah selanjutnya adalah melakukan pengolahan data. Pengolahan disini dilakukan dengan tiga langkah, pertama pengelompokkan data non kelistrikan yaitu data pengusahaan yang dipergunakan untuk melakukan penambahan asumsi pada beban pertahun, kedua pengelompokkan data kelistrikan seperti laporan panjang jaringan, rekapitulasi trafo dan 3 phasa, laporan beban puncak, dan single line diagram APJ yang
4 dipergunakan untuk menentukan kondisi eksisting dan ketiga pengelompokkan data yang dipergunakan untuk pengembangan kebutuhan listrik. Tabel. Pengelompokan Data No Pengelompokkan Data Data Peramalan Data Pengusahaan listrik APJ Jaringan Eksisting GI Penentuan Batang Kondisi Kenaikan prosentase Eksisting konsumsi daya (kva) 3 Feeder yang terdapat Pengembangan pada GI Batang Kebutuhan Data Beban Penyulang Listrik GI Batang tahun Peramalan Beban Tabel 3. Data Pengusahaan APJ Pada Tahun TAHUN RUMAH TANGGA Jumlah Rumah Tangga 49,68 434,38 434,38 47,04 43,74 44,464 Rasio Elektifikasi ( % ) Jumlah Pelanggan 5,990 64,903 7,78 83,6 30,0 35,359 - Delta pelanggan 3,487,93 7,375 0,983 8,75 3,347 Daya tersambung ( KVA ) 68,38 8,09 90,688 03,38 3,79 46,995 Daya tersambung / Pel (VA) Konsumsi Energi ( Mwh ) 77, , , , , , Pertumbuhan ( % ) Konsumsi Energi/Pel (kwh) ,45.05 BISNIS Jumlah Pelanggan 9,54 9,80 0,54,66,95,785 - Delta pelanggan , Daya tersambung ( KVA ) 34,49 37,344 40,683 44,47 46,003 49,77 Daya tersambung / Pel (VA) , Konsumsi Energi ( Mwh ) 49, , , ,80.6 8, , Pertumbuhan ( % ) (4.7) UMUM Jumlah Pelanggan 9,853 9,733 0,440,,063,35 - Delta pelanggan -,4-9,0-93 0, Daya tersambung ( KVA ) 8,853 0,39,536 5,050 7,446 9,335 Daya tersambung / Pel (VA) ,374.9 Konsumsi Energi ( Mwh ) 48, , , , , , Pertumbuhan ( % ) INDUSTRI Jumlah Pelanggan Delta pelanggan 0 9, , Daya tersambung ( KVA ) 55,04 54,49 55,930 55,77 58,04 65,040 Daya tersambung / Pel (VA) ,96.93 Konsumsi Energi ( Mwh ),0.9 3, ,0.5 3, , , Pertumbuhan ( % ) Sumber : PT PLN Persero APJ Dari tabel 3. data pengusahaan di atas, dapat dilihat bahwa tiap tahun mengalami kenaikan dan menjadi acuan digunakan untuk melakukan peramalan. Untuk menentukan kebutuhan konsumsi listrik data peramalan yang dibutuhkan adalah daya tersambung (kva) selama 5 tahun sebelumnya. Setelah hasil asumsi penambahan beban didapatkan dan titik penempatan lokasi kapasitor baru dapat ditentukan. Peramalan dilakukan dari tahun 0 06, sedangkan data pada tahun 0 sebagai data eksisting. Gambar 6. Diagram Alir Metode Peramalan Peramalan beban dapat dilakukan dengan berbagai metode. Hanya saja dalam tugas akhir ini di pergunakan metode asumsi penambahan beban pada trafo distribusi. 3.5 Data Jaringan Eksisting APJ Data jaringan eksisting yang digunakan dalam tugas akhir ini adalah data jaringan eksisting APJ yang terdiri dari Gardu Induk Batang dan pada tahun 0. Peta jaringan jaringan eksisting bisa dilihat pada gambar 7. di bawah ini. Sumber : PT PLN Persero APJ Gambar 7. Peta Jaringan Eksisting APJ
5 3.6 Simulasi Pengembangan Dengan Menggunakan Software ETAP Untuk diagram alir simulasi dengan menggunakan software ETAP dapat dilhat pada gambar 3.4 Pada metode asumsi kenaikan prosentase beban yang digunakan sebagai acuan adalah rata-rata daya yang tersambung (kva) pertahun. Dari perhitungan diatas didapatkan rata-rata kenaikannya adalah sebesar 6.69% (6,7%) pertahun dari data 5 tahun terakhir. Contoh sebagai berikut : Gambar 9. Continuous lumped load pada ETAP sebelum penambahan metode asumsi Gambar 8. Diagram Alir Simulasi ETAP Penambahan Asumsi = % Penambahan Asumsi + % Trafo tahun ke n = 6,7 % (73%) + 73 % = 5 % + 73 % = 78 % IV. ANALISA DAN PEMBAHASAN 4. Peramalan Kebutuhan Beban Data untuk melakukan pengembangan jaringan tegangan menengah dapat di bagi menurut kebutuhan data yang dibagi menjadi dua kategori data, yaitu :. Data peramalan. Data eksisting jaringan APJ Table 4. Hasil perhitungan Total Data Pengusahaan Listrik APJ dari tahun Gambar 0. Penggambaran Jaringan dengan Menggunakan ETAP Sumber : Data Teknis PT PLN (Persero) APJ
6 Gambar. Report simulasi ETAP VOLTAGE DROP = % Tegangan Pangkal GI - % Tegangan Paling Ujung Gambar. Bentuk Jaringan pada Feeder Batang Tabel 7. Data bus pada feeder Batang 0 tahun Penggambaran Kondisi Eksisting Gardu Induk Batang Tahun 0 Tabel 5. Hasil perhitungan drop tegangan GI Batang berdasarkan Simulasi ETAP tahun 0 Dari tabel di atas secara keselururuhan ada 3 feeder yang tidak memenuhi syarat (maksimum 5,5 %) yaitu BTG 0, BTG 0, dan BTG 07, hal ini kemungkinan diakibatkan oleh : Jaringan terlalu panjang Beban yang dilayani pada jaringan terlalu besar Penampang konduktor yang kecil Tabel 6. Hasil perhitungan drop tegangan pada feeder Batang 0 tahun 0-06 Dari tabel 6. dapat dilihat bahwa selama pengembangan dari tahun 0-06 pada feeder Batang 0 mengalami peningkatan pada drop tegangan. Sehingga Dapat mengganggu penyuplaian beban pada sistem. Maka, perlu dilakukan pengujian optimasi pemasangan kapasitor.
7 Tabel 8. Data saluran pada feeder Batang 0 tahun 0 Tabel 9. Kondisi sebelum penempatan kapasitor untuk tahun 0 Dalam pengujian ini, kandidat bus sebagai lokasi penempatan kapasitor dipilih 3 lokasi yaitu bus 43, 44 dan 45 karena bus tersebut memiliki nilai CSI paling besar. Hasil pengujian ditunjukkan pada tabel 0. dan gambar 3. Untuk memperoleh kondisi awal dari sistem seperti tegangan tiap bus maka dilakukan proses aliran daya dan melakukan perhitungan nilai Capacitor suitability index (CSI) sebagai pertimbangan pemilihan kandidat bus. Kondisi awal dari sistem dapat dilihat pada tabel 9. Tabel 0. Hasil pengujian feeder Batang 0 tahun 0
8 ditentukan yakni sebesar 5,5%. Setelah pemasangan kapasitor nilai drop tegangan dapat dikurangi sehingga masih memenuhi syarat nilai standar. Gambar 3. Kandidat bus untuk penempatan kapasitor tahun 0 Dengan cara yang sama, maka didapatkan lokasi bus untuk penempatan kapasitor pada feeder Batang 0 tahun Selanjutnya disimulasikan ke ETAP sesuai dengan lokasi penempatan kapasitor sehingga didapatkan nilai tegangan pangkal, tegangan ujung dan drop tegangan setelah pemasangan kapasitor. Tabel. Nilai drop tegangan pada feeder Batang 0 tahun 0-06 sebelum dipasang kapasitor Tabel. Nilai drop tegangan pada feeder Batang 0 tahun 0-06 setelah dipasang kapasitor Dari tabel. dan tabel. dapat dilihat perbandingan selisih antara tegangan pangkal dan tegangan ujung serta nilai drop tegangan sebelum dan setelah dipasang kapasitor. Sebelum dipasang kapasitor drop tegangan lebih besar dari syarat nilai standar yang V. PENUTUP 5. Kesimpulan Berdasarkan pengujian dan analisis yang telah dilakukan, maka dapat disimpulkan beberapa hal sebagai berikut :. Pada kondisi eksisting terdapat 3 feeder dari GI Batang kurang memenuhi kriteria yang ditetapkan oleh PLN (drop tegangan besar) yaitu : Batang 0 (9.7%), Batang 0 (3.068%), Batang 07 (6.49%). Berdasarkan simulasi software ETAP pada feeder Batang 0 dari tahun 0-06 drop tegangan melebihi standar yang diijinkan yaitu 5,5% sehingga perlu dipasang kapasitor pada lokasi yang optimal. 3. Optimasi penempatan kapasitor menggunakan logika fuzzy dapat menemukan ukuran kapasitor bank yang optimal sehingga dapat memperbaiki drop tegangan sesuai batas batas yang telah ditentukan. 4. Pada pengujian perbaikan tegangan, feeder Batang 0 dari tahun 0-06 (4,6%; 4,0%; 3,5%;,05%; 0,79%) telah memenuhi standart drop tegangan (< 5,5%). 5. Penggunaan kapasitor bank dengan kapasitas tetap mempunyai kelemahan yaitu berapapun jumlah beban yang terpasang maka daya reaktif yang disalurkan tetap. Sehingga mungkin saja suatu ketika terjadi perubahan beban secara drastis dan akan menyebabkan over compensated. 5. Saran. Perlu dikembangkan lebih lanjut untuk optimasi penempatan kapasitor pada feeder-feeder lain yang drop tegangannya melebihi batas yang diijinkan.. Dapat dikembangkan sistem optimasi penempatan kapasitor dengan mempertimbangkan faktor faktor yang lain misalnya pertumbuhan beban di masa
9 mendatang, faktor daya, penggunaan switch kapasitor, dan lain - lain 3. Perlu dikembangkan untuk optimasi penempatan kapasitor untuk sistem jaringan distribusi yang tidak seimbang. DAFTAR PUSTAKA [] Nugroho,A., B,Suroso dan K.I.Santoso, Sistem Informasi Prakiraan Kebutuhan Tenaga Listrik Sistem Distribusi Tenaga Listrik, Universitas Diponegoro, Semarang, 00 [] Rahardjo, Merencanakan Pengembangan Sistem Kelistrikan PLN kedepan Secara Lebih Baik dan Lebih Efisien, PT PLN (Persero) Distribusi Jateng DIY, 006 [3] Sulasno,Ir. Teknik dan Sistem Distribusi Tenaga LIstrik Edisi I, Badan Penerbit Universitas Diponegoro, Semarang, 00. [4] Tim Masterplan, Pembuatan Masterplan Sistem Distribusi 0 KV APJ, Laporan Akhir, Universitas Diponegoro PT PLN (Persero) Distribusi Jateng DIY, 0. [5] Suswanto, D. A., Analisa Peramalan Beban dan Kebutuhan Tenaga Listrik, Buku Ajar BAB XII. [6],Kab Batang Dalam Angka Tahun [006,007,008,009,00,0 ].Badan Statistik Provinsi Kabupaten Batang. [7] Syarip, M, Analisa Pengembangan Jaringan Tegangan Menengah Berdasarkan Data Pengembangan Jaringan di UPJ Wonosobo, Tugas Akhir S-, Universitas Diponegoro, Semarang, 0. [8] Suswanto, D. A., Perencanaan Jaringan Distribusi, Buku Ajar BAB III. [9] Gonen, Turan Electric Power Distribution System Engineering. New York : McGraw-Hill. [0] Dzackiy, Unggul. 0. Optimasi Penempatan Kapasitor Menggunakan Logika Fuzzy dan Algoritma Genetika pada Sistem Distribusi Tenaga Listrik. Semarang : Universitas Diponegoro. [] Prasad, P.V., S. Sivanagaraju and N.Sreenivasulu A Fuzzy- Genetic Algorithm For Optimal Capacitor Placement In Radial Distribution Systems. ARPN Journal of Engineering and Applied Sciences, Vol., No. 3, June. [] Hosea, Emmy dan Adi Nugraha. 00. Optimasi Penentuan Lokasi Switched 0 kv Power Capacitors pada Jaringan Distribusi 0 kv Jawa Timur. Surabaya : Universitas Kristen Petra. BIODATA PENULIS Sigit Wisnu Habsoro lahir di Semarang pada tanggal 3 Agustus 989. Sekarang ini sedang menempuh pendidikan strata satu di Fakultas Teknik Jurusan Teknik Elektro Universitas Diponegoro. Konsentrasi Energi Listrik. Semarang, Oktober 0 Menyetujui dan Mengesahkan, Dosen Pembimbing I Ir. Agung Nugroho, M.kom. NIP Dosen Pembimbing II Ir. Bambang Winardi NIP
ANALISA PENEMPATAN KAPASITOR BANK UNTUK PERHITUNGAN DROP VOLTAGE PADA FEEDER BATANG 02 TAHUN DENGAN SOFTWARE ETAP 7.0.0
ANALISA PENEMPATAN KAPASITOR BANK UNTUK PERHITUNGAN DROP VOLTAGE PADA FEEDER BATANG 02 TAHUN 2012-2016 DENGAN SOFTWARE ETAP 7.0.0 Sigit Wisnu Habsoro *), Agung Nugroho, and Bambang Winardi Jurusan Teknik
Lebih terperinciSIMULASI OPTIMASI PENEMPATAN KAPASITOR MENGGUNAKAN LOGIKA FUZZY DAN ALGORITMA GENETIKA PADA SISTEM TEGANGAN MENENGAH REGION JAWA BARAT
SIMULASI OPTIMASI PENEMPATAN KAPASITOR MENGGUNAKAN LOGIKA FUZZY DAN ALGORITMA GENETIKA PADA SISTEM TEGANGAN MENENGAH REGION JAWA BARAT Gahara Nur Eka Putra NRP : 1022045 E-mail : bb.201smg@gmail.com ABSTRAK
Lebih terperinciSIMULASI OPTIMASI PENEMPATAN KAPASITOR MENGGUNAKAN METODA ALGORITMA KUANTUM PADA SISTEM TEGANGAN MENENGAH REGION JAWA BARAT
SIMULASI OPTIMASI PENEMPATAN KAPASITOR MENGGUNAKAN METODA ALGORITMA KUANTUM PADA SISTEM TEGANGAN MENENGAH REGION JAWA BARAT Mart Christo Belfry NRP : 1022040 E-mail : martchristogultom@gmail.com ABSTRAK
Lebih terperinciSIMULASI PENGEMBANGAN TRAFO DISTRIBUSI BERDASARKAN PERTUMBUHAN BEBAN MENGGUNAKAN MODEL DKL 3,2 DAN SOFTWARE
Makalah Seminar Tugas Akhir SIMULASI PENGEMBANGAN TRAFO DISTRIBUSI BERDASARKAN PERTUMBUHAN BEBAN MENGGUNAKAN MODEL DKL 3,2 DAN SOFTWARE ETAP 7.0.0 TAHUN 2012 2016 DI UPJ BATANG Dhimas Mahardhika. [1],Agung
Lebih terperinciPengembangan Trafo Distribusi Berdasarkan Pertumbuhan Beban Tahun di UPJ Batang
Available online at TRANSMISI Website http://ejournal.undip.ac.id/index.php/transmisi TRANSMISI, 12 (3), 2010, 87-93 Pengembangan Trafo Distribusi Berdasarkan Pertumbuhan Beban Tahun 2012 2016 di UPJ Batang
Lebih terperinciDosen Jurusan Teknik Elektro Universitas Diponegoro
ANALISA KEBUTUHAN GARDU INDUK BARU DI WILAYAH APJ PEKALONGAN DARI TAHUN 2012-2016 Teguh Antoni 1, Agung Nugroho 2, Bambang Winardi 2 Jurusan Teknik Elektro, Fakultas Teknik Universitas Diponegoro Jl. Prof
Lebih terperinciI. PENDAHULUAN II. DASAR TEORI
ANALISA PENGEMBANGAN JARINGAN TEGANGAN MENENGAH BERDASARKAN DATA PENGEMBANGAN JARINGAN DI UPJ WONOSOBO Maulana Syarip 1, Agung Nugroho 2, Karnoto 2 Jurusan Teknik Elektro, Fakultas Teknik Universitas Diponegoro
Lebih terperinciPERKIRAAN KEBUTUHAN ENERGI LISRIK SISTEM DISTRIBUSI TAHUN DI PT.PLN (PERSERO) RAYON BATANG MENGGUNAKAN JARINGAN SARAF TIRUAN (JST)
KETENAGAAN PERKIRAAN KEBUTUHAN ENERGI LISRIK SISTEM DISTRIBUSI TAHUN 2012 2017 DI PT.PLN (PERSERO) RAYON BATANG MENGGUNAKAN JARINGAN SARAF TIRUAN (JST) Herda Dwi Cahyanova *), Susatyo Handoko, ST,MT dan
Lebih terperinciANALISA KEBERADAAN GARDU INDUK BALAPULANG TERHADAP DISTRIBUSI 20 KV DI WILAYAH KERJA UPJ BALAPULANG PT. PLN (PERSERO) JATENG DIY
ANALISA KEBERADAAN GARDU INDUK BALAPULANG TERHADAP DISTRIBUSI 20 KV DI WILAYAH KERJA UPJ BALAPULANG PT. PLN (PERSERO) JATENG DIY *) Bambang Winardi Jurusan Teknik Elektro, Universitas Diponegoro Semarang
Lebih terperinciDAFTAR ISI JUDUL... LEMBAR PRASYARAT GELAR... LEMBAR PERNYATAAN ORISINALITAS... LEMBAR PENGESAHAN... UCAPAN TERIMAKASIH... ABSTRAK...
DAFTAR ISI JUDUL... LEMBAR PRASYARAT GELAR... LEMBAR PERNYATAAN ORISINALITAS... LEMBAR PENGESAHAN... UCAPAN TERIMAKASIH... ABSTRAK... ABSRACT... DAFTAR ISI... DAFTAR TABEL... DAFTAR GAMBAR... DAFTAR LAMPIRAN...
Lebih terperinciREKONFIGURASI JARINGAN DISTRIBUSI TEGANGAN 20 KV PADA FEEDER PANDEAN LAMPER 5 RAYON SEMARANG TIMUR
REKONFIGURASI JARINGAN DISTRIBUSI TEGANGAN 20 KV PADA FEEDER PANDEAN LAMPER 5 RAYON SEMARANG TIMUR Wisnu Aji Nugrahadi *), Juningtyastuti, and Bambang Winardi Jurusan Teknik Elektro, Universitas Diponegoro
Lebih terperinciEVALUASI EKSPANSI JARINGAN TEGANGAN MENENGAH 20 kv GI SOLO BARU
EVALUASI EKSPANSI JARINGAN TEGANGAN MENENGAH 20 kv GI SOLO BARU Diajukan untuk Melengkapi Tugas Akhir dan Memenuhi Syarat-syarat untuk Mencapai Gelar Sarjana Teknik Jurusan Teknik Elektro Fakultas Teknik
Lebih terperinciSTUDI PEMASANGAN KAPASITOR BANK UNTUK MEMPERBAIKI FAKTOR DAYA DALAM RANGKA MENEKAN BIAYA OPERASIONAL PADA JARINGAN DISTRIBUSI 20 KV
STUDI PEMASANGAN KAPASITOR BANK UNTUK MEMPERBAIKI FAKTOR DAYA DALAM RANGKA MENEKAN BIAYA OPERASIONAL PADA JARINGAN DISTRIBUSI 20 KV Dede Kaladri. S Jurusan Teknik Elektro-FTI,Institut Teknologi Sepuluh
Lebih terperinciAbstrak. Kata kunci: kualitas daya, kapasitor bank, ETAP 1. Pendahuluan. 2. Kualitas Daya Listrik
OPTIMALISASI PENGGUNAAN KAPASITOR BANK PADA JARINGAN 20 KV DENGAN SIMULASI ETAP (Studi Kasus Pada Feeder Srikandi di PLN Rayon Pangkalan Balai, Wilayah Sumatera Selatan) David Tampubolon, Masykur Sjani
Lebih terperinciANALISIS TEORITIS PENEMPATAN TRANSFORMATOR DISTRIBUSI MENURUT JATUH TEGANGAN DI PENYULANG BAGONG PADA GARDU INDUK NGAGEL
Analisis Teoritis Penempatan Transformator Distribusi Menurut Jatuh Tegangan Di Penyulang Bagong ANALISIS TEORITIS PENEMPATAN TRANSFORMATOR DISTRIBUSI MENURUT JATUH TEGANGAN DI PENYULANG BAGONG PADA GARDU
Lebih terperinciANALISA PERBAIKAN SUSUT TEKNIS DAN SUSUT TEGANGAN PADA PENYULANG KLS 06 DI GI KALISARI DENGAN MENGGUNAKAN SOFTWARE ETAP 7.5.0
ANALISA PERBAIKAN SUSUT TEKNIS DAN SUSUT TEGANGAN PADA PENYULANG KLS 06 DI GI KALISARI DENGAN MENGGUNAKAN SOFTWARE ETAP 7.5.0 Bambang Winardi *), Agung Warsito, and Meigy Restanaswari Kartika Jurusan Teknik
Lebih terperinciANALISIS TEKNIS EKONOMIS TERHADAP PERTUMBUHAN BEBAN MENGGUNAKAN BACKPROPAGATION TAHUN DI PENYULANG MAYANG
ANALISIS TEKNIS EKONOMIS TERHADAP PERTUMBUHAN BEBAN MENGGUNAKAN BACKPROPAGATION TAHUN 2013-2017 DI PENYULANG MAYANG SKRIPSI Oleh : Diana Nur Fitriga NIM 091910201031 PROGRAM STUDI STRATA 1 TEKNIK ELEKTRO
Lebih terperinciANALISA JATUH TEGANGAN PADA JARINGAN DISTRIBUSI 20 kv DI FEEDER PENYU DI PT. PLN (PERSERO) RAYON BINJAI TIMUR AREA BINJAI LAPORAN TUGAS AKHIR
ANALISA JATUH TEGANGAN PADA JARINGAN DISTRIBUSI 20 kv DI FEEDER PENYU DI PT. PLN (PERSERO) RAYON BINJAI TIMUR AREA BINJAI LAPORAN TUGAS AKHIR Disusun Guna Memenuhi Persyaratan Untuk Menyelesaikan Program
Lebih terperinciKeyword : capacitor, genetic algorithm, power factor, and voltage. Mahasiswa Jurusan Teknik Elektro UNDIP Semarang 2
Makalah Seminar Tugas Akhir OPTIMASI PENEMPATAN KAPASITOR MENGGUNAKAN ALGORITMA GENETIKA PADA SISTEM DISTRIBUSI UNTUK MEMPERBAIKI FAKTOR DAYA DAN TEGANGAN Hadha Alamajibuwono 1, Tedjo Sukmadi 2, Susatyo
Lebih terperinciKOKO SURYONO D
ANALISIS DROP TEGANGAN SALURAN DISTRIBUSI 20 KV PADA PENYULANG WONOGIRI 8 TUGAS AKHIR Diajukan Untuk Melengkapi Tugas Akhir dan Memenuhi Syarat-syarat Untuk Mencapai Gelar Sarjana Teknik Fakultas Teknik
Lebih terperinciANALISIS JATUH TEGANGAN DAN RUGI DAYA PADA JARINGAN TEGANGAN RENDAH MENGGUNAKAN SOFTWARE ETAP
ANALISIS JATUH TEGANGAN DAN RUGI DAYA PADA JARINGAN TEGANGAN RENDAH MENGGUNAKAN SOFTWARE ETAP 12.6.0 Fani Istiana Handayani * ), Yuningtyastuti, Agung Nugroho Jurusan Teknik Elektro, Fakultas Teknik, Universitas
Lebih terperinciProsiding Seminar Nasional Aplikasi Sains & Teknologi (SNAST) 2014ISSN: X Yogyakarta,15 November 2014
ANALISIS PERBAIKAN TEGANGAN PADA SUBSISTEM DENGAN PEMASANGAN KAPASITOR BANK DENGAN ETAP VERSI 7.0 Wiwik Handajadi 1 1 Electrical Engineering Dept. of Institute of Sains & Technology AKPRIND Yogyakarta
Lebih terperinciOPTIMASI PENEMPATAN KAPASITOR PADA SISTEM DISTRIBUSI LISTRIK DENGAN METODE CLONAL SELECTION (STUDI KASUS DI PENYULANG WATU ULO JEMBER) SKRIPSI.
OPTIMASI PENEMPATAN KAPASITOR PADA SISTEM DISTRIBUSI LISTRIK DENGAN METODE CLONAL SELECTION (STUDI KASUS DI PENYULANG WATU ULO JEMBER) SKRIPSI Oleh NiraWidyaPangestika NIM 091910201029 JURUSAN TEKNIK ELEKTRO
Lebih terperinciOleh: Erhaneli (1), Ramadonal (2) (1) Dosen Jurusan Teknik Elektro (2) Mahasiswa Jurusan Teknik Elektro
OPTIMASI PEMASANGAN KAPASITOR DALAM PERBAIKAN FAKTOR DAYA DAN DROP TEGANGAN PADA SISTEM DISTRIBUSI 20 k (Feeder Ekspres GH Balitan Rayon Sitiung) Menggunakan Simulasi ETAP 7,5 Oleh: Erhaneli (1), Ramadonal
Lebih terperinciKeyword : capacitor, fuzzy logic, genetic algorithm
Makalah Seminar Tugas Akhir OPTIMASI PENEMPATAN KAPASITOR MENGGUNAKAN LOGIKA FUZZY DAN ALGORITMA GENETIKA PADA SISTEM DISTRIBUSI TENAGA LISTRIK Unggul Dzackiy K 1, Susatyo Handoko 2, Bambang Winardi 2
Lebih terperinciMETODE PENDEKATAN UNTUK MEREKONFIGURASI PANJANG MAKSIMAL PADA PENYULANG TAMBAK LOROK 04 DAN KALISARI 02 DI UPJ SEMARANG TENGAH
METODE PENDEKATAN UNTUK MEREKONFIGURASI PANJANG MAKSIMAL PADA PENYULANG TAMBAK LOROK 04 DAN KALISARI 02 DI UPJ SEMARANG TENGAH Zulfakar Athur Banartama 1, Hermawan 2, Karnoto 2 Jurusan Teknik Elektro,
Lebih terperinciANALISIS JATUH TEGANGAN DAN RUGI DAYA PADA JARINGAN TEGANGAN RENDAH MENGGUNAKAN SOFTWARE ETAP
ANALISIS JATUH TEGANGAN DAN RUGI DAYA PADA JARINGAN TEGANGAN RENDAH MENGGUNAKAN SOFTWARE ETAP 12.6.0 Fani Istiana Handayani * ), Yuningtyastuti, and Agung Nugroho Jurusan Teknik Elektro, Fakultas Teknik,
Lebih terperinciAnalisa Drop Tegangan PT PLN (Persero) Rayon Lubuk Sikaping Setelah Penambahan PLTM Guntung Oleh:
199 JURNAL TEKNIK ELEKTRO ITP, Vol. 6, No. 2, JULI 2017 Analisa n PT PLN (Persero) Rayon Lubuk Sikaping Setelah Penambahan PLTM Guntung Oleh: Asnal Effendi (1), Arfita Yuana Dewi (1), Edward Crismas (2)
Lebih terperinciSTUDI ANALISA PEMASANGAN KAPASITOR PADA JARINGAN UDARA TEGANGAN MENENGAH 20 KV TERHADAP DROP TEGANGAN (APLIKASI PADA FEEDER 7 PINANG GI MUARO BUNGO)
STUDI ANALISA PEMASANGAN KAPASITOR PADA JARINGAN UDARA TEGANGAN MENENGAH 20 KV TERHADAP DROP TEGANGAN (APLIKASI PADA FEEDER 7 PINANG GI MUARO BUNGO) Oleh : Sepanur Bandri 1 dan Topan Danial 2 1) Dosen
Lebih terperinciANALISA JATUH TEGANGAN DAN PENANGANAN PADA JARINGAN DISTRIBUSI 20 KV RAYON PALUR PT. PLN (PERSERO) MENGGUNAKAN ETAP 12.6
ANALISA JATUH TEGANGAN DAN PENANGANAN PADA JARINGAN DISTRIBUSI 20 KV RAYON PALUR PT. PLN (PERSERO) MENGGUNAKAN ETAP 12.6 PUBLIKASI ILMIAH Disusun sebagai salah satu syarat menyelesaikan Program Studi Strata
Lebih terperinciBAB III METODE PENELITIAN
BAB III METODE PENELITIAN 3.1. Metode Waktu dan Lokasi Penelitian Pelaksanaan penelitian ini berlokasi di kabupaten Bantul provinsi Yogyakarta, tepatnya di PT PLN (persero) APJ (Area Pelayanan Jaringan)
Lebih terperinciBAB II TINJAUAN PUSTAKA
BAB II TINJAUAN PUSTAKA 2.1 Kualitas Daya Listrik Peningkatan terhadap kebutuhan dan konsumsi energi listrik yang baik dari segi kualitas dan kuantitas menjadi salah satu alasan mengapa perusahaan utilitas
Lebih terperinciSIMULASI DAN ANALISIS ALIRAN DAYA SISTEM TENAGA. LISTRIK 20 kv REGION CILACAP MENGGUNAKAN METODE NEWTHON RAPSHON
SIMULASI DAN ANALISIS ALIRAN DAYA SISTEM TENAGA LISTRIK 20 kv REGION CILACAP MENGGUNAKAN METODE NEWTHON RAPSHON SKRIPSI Diajukan Untuk Memenuhi Salah Satu Persyaratan Dalam Menyelesaikan Pendidikan Strata
Lebih terperinciBAB II JARINGAN DISTRIBUSI TENAGA LISTRIK
2.1 Umum BAB II JARINGAN DISTRIBUSI TENAGA LISTRIK Kehidupan moderen salah satu cirinya adalah pemakaian energi listrik yang besar. Besarnya pemakaian energi listrik itu disebabkan karena banyak dan beraneka
Lebih terperinci: Distributed Generation, Voltage Profile, Power Losses, Load Flow Analysis, EDSA 2000
ABSTRAK Salah satu teknik untuk memperbaiki jatuh tegangan adalah dengan pemasangan (DG) Distributed Generation. Salah satu teknologi Distributed Generation yang ada di Bali adalah PLTS Kubu Karangasem
Lebih terperinciTabarok et al., Optimasi Penempatan Distributed Generation (DG) dan Kapasitor... 35
Tabarok et al., Optimasi Penempatan Distributed Generation (DG) dan Kapasitor... 35 Optimasi Penempatan Distributed Generation (DG) dan Kapasitor pada Sistem Distribusi Radial Menggunakan Metode Genetic
Lebih terperinciDAFTAR ISI SAMPUL DALAM...
DAFTAR ISI SAMPUL DALAM... i PRASYARAT GELAR... ii LEMBAR PERNYATAAN ORISINALITAS... iii LEMBAR PENGESAHAN... iv UCAPAN TERIMAKASIH... v ABSTRAK... vii ABSTRACT... viii DAFTAR ISI... ix DAFTAR GAMBAR...
Lebih terperinciANALISA ALTERNATIF PERBAIKAN UNTUK MENGATASI DROP TEGANGAN PADA FEEDER KOTA 20 KV DI ROKAN HULU
ANALISA ALTERNATIF PERBAIKAN UNTUK MENGATASI DROP TEGANGAN PADA FEEDER KOTA KV DI ROKAN HULU Muhammad Fadli Biya Lubis, Nurhalim Jurusan Teknik Elektro Fakultas Teknik Universitas Riau Kampus Binawidya
Lebih terperinciANALISIS KETIDAKSEIMBANGAN BEBAN PADA JARINGAN DISTRIBUSI SEKUNDER GARDU DISTRIBUSI DS 0587 DI PT. PLN (Persero) DISTRIBUSI BALI RAYON DENPASAR
SKRIPSI ANALISIS KETIDAKSEIMBANGAN BEBAN PADA JARINGAN DISTRIBUSI SEKUNDER GARDU DISTRIBUSI DS 0587 DI PT. PLN (Persero) DISTRIBUSI BALI RAYON DENPASAR WAHYU SUSONGKO NIM. 0819451020 JURUSAN TEKNIK ELEKTRO
Lebih terperinciPERHITUNGAN DAN ANALISIS KESEIMBANGAN BEBAN PADA SISTEM DISTRIBUSI 20 KV TERHADAP RUGI-RUGI DAYA (STUDI KASUS PADA PT.
PERHITUNGAN DAN ANALISIS KESEIMBANGAN BEBAN PADA SISTEM DISTRIBUSI 20 KV TERHADAP RUGI-RUGI DAYA (STUDI KASUS PADA PT. PLN UPJ SLAWI) Tejo Sukmadi 1, Bambang_Winardi 2 1,2 Jurusan Teknik Elektro, Fakultas
Lebih terperinciPerencanaan Kebutuhan Distribusi Sekunder Perumahan RSS Manulai II
10 Jurnal Rekayasa Elektrika Vol. 10,. 1, April 2012 Perencanaan Kebutuhan Distribusi Sekunder Perumahan RSS Manulai II Evtaleny R. Mauboy dan Wellem F. Galla Jurusan Teknik Elektro, Universitas Nusa Cendana
Lebih terperinciBAB IV ANALISA DAN PEMBAHASAN
BAB IV ANALISA DAN PEMBAHASAN 4.1 Informasi Umum 4.1.1 Profil Kabupaten Bantul Kabupaten Bantul merupakan salah satu kabupaten yang berada di provinsi Daerah Istimewa Yogyakarta (DIY) terletak antara 07
Lebih terperinciPENGARUH PEMASANGAN KAPASITOR SHUNT TERHADAP KONSUMSI DAYA AKTIF INSTALASI LISTRIK
Abstract PENGARUH PEMASANGAN KAPASITOR SHUNT TERHADAP KONSUMSI DAYA AKTIF INSTALASI LISTRIK Oleh : Winasis, Azis Wisnu Widhi Nugraha Program Sarjana Teknik Unsoed Purwokerto The application of shunt capacitor
Lebih terperinciKeyword : capacitor, particle swarm optimization, power losses, and voltage
OPTIMASI PENEMPATAN DAN KAPASITAS KAPASITOR BANK PADA SISTEM DISTRIBUSI UNTUK MEREDUKSI RUGI DAYA MENGGUNAKAN PARTICLE SWARM OPTIMIZATION Mira Erviana 1, Ir. Yuningtyastuti, MT 2, Susatyo Handoko, ST.,
Lebih terperinciSTUDI PENYALURAN DAYA LISTRIK PADA JARINGAN DISTRIBUSI TEGANGAN MENENGAH PADA PT. PLN (Persero) GARDU INDUK TALANG RATU PALEMBANG
STUDI PENYALURAN DAYA LISTRIK PADA JARINGAN DISTRIBUSI TEGANGAN MENENGAH PADA PT. PLN (Persero) GARDU INDUK TALANG RATU PALEMBANG PROPOSAL LAPORAN AKHIR Disusun Untuk Memenuhi Salah Satu Syarat Laporan
Lebih terperinciANALISIS KETIDAKSEIMBANGAN BEBAN TRAFO 1 GI SRONDOL TERHADAP RUGI-RUGI AKIBAT ARUS NETRAL DAN SUHU TRAFO MENGGUNAKAN ETAP
ANALISIS KETIDAKSEIMBANGAN BEBAN TRAFO 1 GI SRONDOL TERHADAP RUGI-RUGI AKIBAT ARUS NETRAL DAN SUHU TRAFO MENGGUNAKAN ETAP 12.6.0 Dennis Satria Wahyu Jayabadi *), Bambang Winardi, and Mochammad Facta Departemen
Lebih terperinciANALISA EFISIENSI JARINGAN PADA SISTEM DISTRIBUSI PRIMER 20 KV DI GARDU INDUK TALANG KELAPA PT. PLN (PERSERO) TRAGI BORANG
ANALISA EFISIENSI JARINGAN PADA SISTEM DISTRIBUSI PRIMER 20 KV DI GARDU INDUK TALANG KELAPA PT. PLN (PERSERO) TRAGI BORANG LAPORAN AKHIR Dibuat untuk Memenuhi Syarat Menyelesaikan Pendidikan Diploma III
Lebih terperinciABSTRAK. Kata kunci : Kondisi tanpa Harmonisa, Kondisi dengan Harmonisa, Harmonic Analysis Load Flow, Rugi Daya, Sistem Tegangan Rendah.
ABSTRAK Penyulang Menjangan merupakan sistem jaringan tegangan menengah 20 kv yang melayani daerah Gilimanuk dan sebagian Buleleng. Penyulang Menjangan memiliki total gardu terpasang sebanyak 69 Gardu,
Lebih terperinciMEMPERBAIKI PROFIL TEGANGAN DI SISTEM DISTRIBUSI PRIMER DENGAN KAPASITOR SHUNT. Abstrak
MEMERBAIKI ROFIL TEGANGAN DI SISTEM DISTRIBUSI RIMER DENGAN KAASITOR SHUNT Ngakan utu Satriya Utama Staff engajar Jurusan Teknik Elektro, Fakultas Teknik, Universitas Udayana Kampus Bukit Jimbaran, Bali,
Lebih terperinciBAB I PENDAHULUAN. sebagai salah satu kebutuhan utama bagi penunjang dan pemenuhan kebutuhan
BAB I PENDAHULUAN 1.1 Latar Belakang Perkembangan teknologi yang semakin pesat memicu kebutuhan akan energi, terutama energi listrik. Masalah listrik menjadi polemik yang berkepanjangan dan memunculkan
Lebih terperinciPENENTUAN TITIK INTERKONEKSI DISTRIBUTED GENERATION
PENENTUAN TITIK INTERKONEKSI DISTRIBUTED GENERATION (DG) PADA JARINGAN 20 KV DENGAN BANTUAN METODE ARTIFICIAL BEE COLONY STUDI KASUS : PLTMH AEK SILAU 2 Syilvester Sitorus Pane, Zulkarnaen Pane Konsentrasi
Lebih terperinciJurnal Media Elektro, Vol. 1, No. 3, April 2013 ISSN
Analisis Jatuh Pada Penyulang 20 kv Berdasarkan pada Perubahan Beban (Studi Kasus Penyulang Penfui dan Penyulang Oebobo PT. PLN Persero Rayon Kupang) Agusthinus S. Sampeallo, Wellem F. Galla, Rendi A.
Lebih terperinciPERBAIKAN REGULASI TEGANGAN
JURUSAN TEKNIK ELEKTRO FAKULTAS TEKNOLOGI INDUSTRI INSTITUT TEKNOLOGI SEPULUH NOPEMBER PERBAIKAN REGULASI TEGANGAN Distribusi Tenaga Listrik Ahmad Afif Fahmi 2209 100 130 2011 REGULASI TEGANGAN Dalam Penyediaan
Lebih terperinciPERENCANAAN PEMASANGAN TRANSFORMATOR SISIPAN GARDU DISTRIBUSI I.2014 DENGAN MENGGUNAKAN ETAP 12.6 LAPORAN AKHIR
PERENCANAAN PEMASANGAN TRANSFORMATOR SISIPAN GARDU DISTRIBUSI I.2014 DENGAN MENGGUNAKAN ETAP 12.6 LAPORAN AKHIR Disusun untuk memenuhi syarat menyelesaikan Pendidikan Diploma III pada Jurusan Teknik Elektro
Lebih terperinciANALISIS PERSENTASE PEMBEBANAN DAN DROP TEGANGAN JARINGAN TEGANGAN RENDAH PADA GARDU DISTRIBUSI GA 0032 PENYULANG WIBRATA
TA: ANALISIS PERSENTASE PEMBEBANAN 42 ANALISIS PERSENTASE PEMBEBANAN DAN DROP TEGANGAN JARINGAN TEGANGAN RENDAH PADA GARDU DISTRIBUSI GA 0032 PENYULANG WIBRATA I Ketut Ta 1, I Gede Nyoman Sangka 2, I Wayan
Lebih terperinciSTUDI PENGATURAN TEGANGAN PADA JARINGAN DISTRIBUSI 20 KV YANG TERHUBUNG DENGAN DISTRIBUTED GENERATION (STUDI KASUS: PENYULANG TR 5 GI TARUTUNG)
STUDI PENGATURAN TEGANGAN PADA JARINGAN DISTRIBUSI 20 KV YANG TERHUBUNG DENGAN DISTRIBUTED GENERATION (STUDI KASUS: PENYULANG TR 5 GI TARUTUNG) Andika Handy (1), Zulkarnaen Pane (2) Konsentrasi Teknik
Lebih terperinciJurnal Media Elektro Vol. V No. 2 ISSN: ANALISIS RUGI-RUGI DAYA JARINGAN DISTRIBUSI 20 kv PADA SISTEM PLN KOTA KUPANG
ANALISIS RUGI-RUGI DAYA JARINGAN DISTRIBUSI 20 kv PADA SISTEM PLN KOTA KUPANG Sri Kurniati. A, Sudirman. S Jurusan Teknik Elektro, Fakultas Sains dan Teknik, Undana, AdiSucipto Penfui, Kupang, Indonesia,
Lebih terperinciBAB II JARINGAN DISTRIBUSI TENAGA LISTRIK. karena terdiri atas komponen peralatan atau mesin listrik seperti generator,
BAB II JARINGAN DISTRIBUSI TENAGA LISTRIK II.1. Sistem Tenaga Listrik Struktur tenaga listrik atau sistem tenaga listrik sangat besar dan kompleks karena terdiri atas komponen peralatan atau mesin listrik
Lebih terperinciDepartemen Teknik Elektro, Universitas Diponegoro Jl. Prof. Sudharto, SH, Kampus UNDIP Tembalang, Semarang 50275, Indonesia
OPTIMISASI PENEMPATAN KAPASITOR BANK UNTUK MEREDUKSI RUGI DAYA MENGGUNAKAN FLOWER POLLINATION ALGORITHM PADA JARINGAN AUXILIARY LOAD PT.PJB PEMBANGKITAN INDRAMAYU 3X33 MW Tito Wiratsongko *), Tejo Sukmadi,
Lebih terperinciPERBAIKAN LOSSES DAN DROP TEGANGAN PWI 9 DENGAN PELIMPAHAN BEBAN KE PENYULANG BARU PWI 11 DI PT PLN (PERSERO) AREA SEMARANG
PERBAIKAN LOSSES DAN DROP TEGANGAN PWI 9 DENGAN PELIMPAHAN BEBAN KE PENYULANG BARU PWI 11 DI PT PLN (PERSERO) AREA SEMARANG Bambang Winardi *), Heru Winarno, and Kurnanda Rizky Aditama Jurusan Teknik Elektro,
Lebih terperinciSTUDY PERBAIKAN FAKTOR DAYA PADA SISTEM RADIAL 20 KV ANALISIS MENGGUNAKAN ETAP. Oleh : FAREL NIM :
STUDY PERBAIKAN FAKTOR DAYA PADA SISTEM RADIAL 20 KV ANALISIS MENGGUNAKAN ETAP Diajukan untuk memenuhi salah satu persyaratan dalam menyelesaikan pendidikan sarjana ( S-1 ) pada Departemen Teknik Elektro
Lebih terperinciPERHITUNGAN JATUH TEGANGAN PADA PENYULANG BELIMBING YANG DISUPLAI DARI GARDU INDUK BOOM BARU DENGAN BANTUAN SOFTWARE ETAP
PERHITUNGAN JATUH TEGANGAN PADA PENYULANG BELIMBING YANG DISUPLAI DARI GARDU INDUK BOOM BARU DENGAN BANTUAN SOFTWARE ETAP LAPORAN AKHIR Dibuat Untuk Memenuhi Syarat Menyelesaikan Pendidikan Diploma III
Lebih terperinciPENGARUH CAPACITOR BANK SWITCHING TERHADAP KUALITAS DAYA EFFECT OF CAPACITOR BANK SWITCHING ON POWER QUALITY
Jurnal Teknik dan Ilmu Komputer PENGARUH CAPACITOR BANK SWITCHING TERHADAP KUALITAS DAYA EFFECT OF CAPACITOR BANK SWITCHING ON POWER QUALITY Emmy Hosea 1, Ontoseno Penangsang 2, Algavien Tinus 3 1&3 Program
Lebih terperinciLaporan akhir ini disusun sebagai salah satu syarat menyelesaikan. Pendidikan Diploma III pada Jurusan Teknik Elektro. Program Strudi Teknik Listrik
ANALISA EFISIENSI PENYALURAN DAYA LISTRIK PADA JARINGAN DISTRIBUSI SEKUNDER DI PENYULANG KALIMANTAN DI PT.PLN (PERSERO) RAYON AMPERA Laporan akhir ini disusun sebagai salah satu syarat menyelesaikan Pendidikan
Lebih terperinciOptimasi Pemasangan dan Kapasitas Kapasitor Shunt Pada Jaringan Distribusi Penjulang Menjangan
Teknologi Elektro, Vol. 16, No. 02, Mei - Agustus 2017 7 Optimasi Pemasangan dan Kapasitas Kapasitor Shunt Pada Jaringan Distribusi Penjulang Menjangan Chandra Wimar Tono Manurung 1, I Wayan Sukerayasa
Lebih terperinciPenentuan Kapasitas dan Lokasi Optimal Penempatan Kapasitor Bank Pada Penyulang Rijali Ambon Menggunakan Sistem Fuzzy
119 Penentuan Kapasitas dan Lokasi Optimal Penempatan Kapasitor Bank Pada Penyulang Rijali Ambon Menggunakan Sistem Fuzzy Hamles Leonardo Latupeirissa, Agus Naba dan Erni Yudaningtyas Abstrak Penelitian
Lebih terperinciANALISIS KINERJA TRANSFORMATOR BANK PADA JARINGAN DISTRIBUSI GUNA MENGURANGI SUSUT TEKNIS ENERGI LISTRIK
ANALISIS KINERJA TRANSFORMATOR BANK PADA JARINGAN DISTRIBUSI GUNA MENGURANGI SUSUT TEKNIS ENERGI LISTRIK Iman Setiono, 1 Galuh Prastyani 2 Jurusan Teknik Elektro Program Diploma III Sekolah Vokasi, Universitas
Lebih terperinciANALISIS PEHITUNGAN RUGI-RUGI DAYA PADA GARDU INDUK PLTU 2 SUMUT PANGKALAN SUSU DENGAN MENGGUNAKAN PROGRAM SIMULASI ELECTRICAL TRANSIENT ANALYZER
ANALISIS PEHITUNGAN RUGI-RUGI DAYA PADA GARDU INDUK PLTU SUMUT PANGKALAN SUSU DENGAN MENGGUNAKAN PROGRAM SIMULASI ELECTRICAL TRANSIENT ANALYZER Asri Akbar, Surya Tarmizi Kasim Konsentrasi Teknik Energi
Lebih terperinciANALISIS DAMPAK PEMASANGAN DISTIBUTED GENERATION (DG) TERHADAP PROFIL TEGANGAN DAN RUGI-RUGI DAYA SISTEM DISTRIBUSI STANDAR IEEE 18 BUS
F.10. Analisis dampak pemasangan distributed generation (DG)... (Agus Supardi dan Romdhon Prabowo) ANALISIS DAMPAK PEMASANGAN DISTIBUTED GENERATION (DG) TERHADAP PROFIL TEGANGAN DAN RUGI-RUGI DAYA SISTEM
Lebih terperinciBAB I PENDAHULUAN 1.1 Latar Belakang Tri Fani, 2014 Studi Pengaturan Tegangan Pada Sistem Distribusi 20 KV Menggunakan ETAP 7.0
BAB I PENDAHULUAN 1.1 Latar Belakang Dewasa ini, energi listrik menjadi kebutuhan yang sangat penting bagi masyarakat. Kebutuhan energi listrik semakin meningkat dari tahun ke tahun untuk memenuhi kebutuhan
Lebih terperinciANALISIS KEDIP TEGANGAN AKIBAT GANGGUAN HUBUNG SINGKAT PADA PENYULANG ABANG DI KARANGASEM
SKRIPSI ANALISIS KEDIP TEGANGAN AKIBAT GANGGUAN HUBUNG SINGKAT PADA PENYULANG ABANG DI KARANGASEM I MADE YOGA DWIPAYANA JURUSAN TEKNIK ELEKTRO DAN KOMPUTER FAKULTAS TEKNIK UNIVERSITAS UDAYANA BUKIT JIMBARAN
Lebih terperinciatau pengaman pada pelanggan.
16 b. Jaringan Distribusi Sekunder Jaringan distribusi sekunder terletak pada sisi sekunder trafo distribusi, yaitu antara titik sekunder dengan titik cabang menuju beban (Lihat Gambar 2.1). Sistem distribusi
Lebih terperinciANALISIS TEGANGAN JATUH PADA JARINGAN DISTRIBUSI RADIAL TEGANGAN RENDAH oleh : Fitrizawati ABSTRACT
ANALISIS TEGANGAN JATUH PADA JARINGAN DISTRIBUSI RADIAL TEGANGAN RENDAH oleh : Fitrizawati ABSTRACT According to the web distribution, the voltage drop is counted from the source power until the consumer.
Lebih terperinciOPTIMASI PENEMPATAN KAPASITOR PADA SALURAN DISTRIBUSI 20 kv DENGAN MENGGUNAKAN METODE KOMBINASI FUZZY DAN ALGORITMA GENETIKA
OPTIMASI PENEMPATAN KAPASITOR PADA SALURAN DISTRIBUSI 20 kv DENGAN MENGGUNAKAN METODE KOMBINASI FUZZY DAN ALGORITMA GENETIKA I Made Wartana, Mimien Mustikawati Program Studi Teknik Elektro, Fakultas Teknologi
Lebih terperinciANALISA KESEIMBANGAN BEBAN SISTEM DISTRIBUSI 20 KV PADA PENYULANG KUTILANG SUPPLY DARI GI SEDUDUK PUTIH MENGGUNAKAN ETAP 12.6
ANALISA KESEIMBANGAN BEBAN SISTEM DISTRIBUSI 20 KV PADA PENYULANG KUTILANG SUPPLY DARI GI SEDUDUK PUTIH MENGGUNAKAN ETAP 12.6 LAPORAN AKHIR Disusun Untuk Memenuhi Syarat Menyelesaikan Pendidikan Diploma
Lebih terperinciANALISIS KOORDINASI ISOLASI SALURAN UDARA TEGANGAN TINGGI 150 KV TERHADAP SAMBARAN PETIR DI GIS TANDES MENGGUNAKAN PERANGKAT LUNAK EMTP RV
TUGAS AKHIR RE 1599 ANALISIS KOORDINASI ISOLASI SALURAN UDARA TEGANGAN TINGGI 150 KV TERHADAP SAMBARAN PETIR DI GIS TANDES MENGGUNAKAN PERANGKAT LUNAK EMTP RV IKA PRAMITA OCTAVIANI NRP 2204 100 028 Dosen
Lebih terperinciBAB I PENDAHULUAN. pembangkit listrik, jaringan transmisi dan saluran distribusi seperti pada Gambar
1 BAB I PENDAHULUAN 1.1 Latar Belakang Perencanaan tenaga listrik merupakan salah satu aspek penting yang perlu dipertimbangkan dalam membangun sebuah jaringan listrik. Jaringan listrik yang baik adalah
Lebih terperinciANALISIS RUGI-RUGI ENERGI SISTEM DISTRIBUSI PADA GARDU INDUK SEI. RAYA
ANALISIS RUGI-RUGI ENERGI SISTEM DISTRIBUSI PADA GARDU INDUK SEI. RAYA Agus Hayadi Program Studi Teknik Elektro Jurusan Teknik Elektro Fakultas Teknik Universitas Tanjungpura agushayadi@yahoo.com Abstrak-
Lebih terperinciSTUDI PENGARUH PEMASANGAN STATIC VAR COMPENSATOR TERHADAP PROFIL TEGANGAN PADA PENYULANG NEUHEN
: 43-49 STUDI PENGARUH PEMASANGAN STATIC VAR COMPENSATOR TERHADAP PROFIL TEGANGAN PADA PENYULANG NEUHEN Alkindi #1, Mahdi Syukri #2, Syahrizal #3 # Jurusan Teknik Elektro dan Komputer, Fakultas Teknik,
Lebih terperinciABSTRAK. Kata Kunci : Perumahan Nuansa Kori Jimbaran, drop tegangan, JTR. vii
ABSTRAK Perumahan Nuansa Kori Jimbaran disuplai oleh salah satu trafo distribusi KA1441 melalui Penyulang Jimbaran. Trafo KA1441 berlokasi di Perumahan Nuansa Kori Jimbaran dengan kapasitas 250 KVA yang
Lebih terperinciANALISA RUGI-RUGI DAYA LISTRIK PADA JARINGAN DISTRIBUSI DI PENYULANG MERAK PT. PLN RAYON KENTEN MENGGUNAKAN SOFTWARE ETAP 12.6
ANALISA RUGI-RUGI DAYA LISTRIK PADA JARINGAN DISTRIBUSI DI PENYULANG MERAK PT. PLN RAYON KENTEN MENGGUNAKAN SOFTWARE ETAP 12.6 Laporan Akhir Disusun Untuk Memenuhi Syarat Menyelesaikan Pendidikan Diploma
Lebih terperinciAnalisis Keberadaan Dan Pengembangan Gardu Induk Distribusi 20 kv Di Kota Pekanbaru
Analisis Keberadaan Dan Pengembangan Gardu Induk Distribusi 0 kv Di Kota Pekanbaru Ferry. M*,Dian Yayan Sukma**, Edy Ervianto** *Alumni Teknik Elektro Universitas Riau **Jurusan Teknik Elektro Universitas
Lebih terperinciPoliteknik Negeri Sriwijaya BAB 1 PENDAHULUAN
BAB 1 PENDAHULUAN 1.1. Latar Belakang Energi listrik merupakan hal yang sangat penting dalam kehidupan modern dewasa ini. Dimana energi listrik mempunyai suatu fungsi yang dapat memberikan suatu kebutuhan
Lebih terperinciAnalisis Aliran Daya Pada Sistem Distribusi Radial 20KV PT. PLN (Persero) Ranting Rasau Jaya
5 Analisis Aliran Daya Pada Sistem Distribusi Radial 0KV PT. PLN (Persero) Ranting Rasau Jaya Dedy Noverdy. R Program Studi Teknik Elektro Jurusan Teknik Elektro Fakultas Teknik Universitas Tanjungpura
Lebih terperinciANALISIS OPTIMUM DISTRIBUTED GENERATION PADA KELUARAN TRANSFORMATOR UNIT I KAPASITAS 30 MVA DI GI MRICA KABUPATEN BANJARNEGARA DENGAN SOFTWARE ETAP 7.0.0 Melfa Silitonga 1, Karnoto, ST, MT, 2 Susatyo Handoko,ST,
Lebih terperinciPerhitungan Susut Daya Pada Jaringan Tegangan Menengah 20KV Pada Penyulang Meranti di PT. PLN (PERSERO) Rayon Ampera Palembang
Perhitungan Susut Daya Pada Jaringan Tegangan Menengah 20KV Pada Penyulang Meranti di PT. PLN (PERSERO) Rayon Ampera Palembang Laporan Akhir ini disusun sebagai salah satu syarat Menyelesaikan pendidikan
Lebih terperinciANALISIS JATUH TEGANGAN DAN ARUS HUBUNG SINGKAT PADA JARINGAN TEGANGAN MENENGAH PT RUM
ANALISIS JATUH TEGANGAN DAN ARUS HUBUNG SINGKAT PADA JARINGAN TEGANGAN MENENGAH PT RUM Farid Hermanto *), Karnoto, and Tejo Sukmadi Jurusan Teknik Elektro, Universitas Diponegoro Semarang Jln. Prof. Sudharto,
Lebih terperinciSTUDI KEAMANAN SUPLAI ENERGI LISTRIK BALI SAMPAI DENGAN TAHUN 2025
STUDI KEAMANAN SUPLAI ENERGI LISTRIK BALI SAMPAI DENGAN TAHUN 2025 TUGAS AKHIR Diajukan untuk memenuhi sebagian persyaratan menyelesaikan studi Program Sarjana Strata Satu (S1) Jurusan Teknik Elektro IGUSTI
Lebih terperinciPENEMPATAN KAPASITOR DAN OPTIMASI KAPASITASNYA MENGGUNAKAN ARTIFICIAL BEE COLONY (ABC) PADA SALURAN DISTRIBUSI PRIMER
146 Dielektrika ISSN 2086-9487 Vol. 1, No. 2 : 146 153 Agustus 2014 PENEMPATAN KAPASITOR DAN OPTIMASI KAPASITASNYA MENGGUNAKAN ARTIFICIAL BEE COLONY (ABC) PADA SALURAN DISTRIBUSI PRIMER Wildan Faisal Harharah1
Lebih terperinciEVALUASI RUGI-RUGI JARINGAN YANG DILAYANI OLEH JARINGAN PLTS TERPUSAT SIDING
EVALUASI RUGI-RUGI JARINGAN YANG DILAYANI OLEH JARINGAN PLTS TERPUSAT SIDING Didik Martono Program Studi Teknik Elektro Jurusan Teknik Elektro Fakultas Teknik Universitas Tanjungpura aadjanu@gmail.com
Lebih terperinciBAB III METODE PENELITIAN. keras dan perangkat lunak, adapun perangkat tersebut yaitu: laptop yang dilengkapi dengan peralatan printer.
BAB III METODE PENELITIAN 3.1 Alat dan Bahan Penelitian Alat dan bahan yang digunakan dalam penelitian ini terdiri dari perangkat keras dan perangkat lunak, adapun perangkat tersebut yaitu: 1. Perangkat
Lebih terperinciPENGARUH PENAMBAHAN JARINGAN TERHADAP DROP TEGANGAN PADA SUTM 20 KV FEEDER KERSIK TUO RAYON KERSIK TUO KABUPATEN KERINCI
PENGARUH PENAMBAHAN JARINGAN TERHADAP DROP TEGANGAN PADA SUTM 0 KV FEEDER KERSIK TUO RAYON KERSIK TUO KABUPATEN KERINCI Erhaneli (1), Aldi Riski () (1) Dosen Jurusan Teknik Elektro () Mahasiswa Jurusan
Lebih terperinciANALISA PERHITUNGAN DROP TEGANGAN MENGGUNAKAN RUMUS DAN MENGGUNAKAN APLIKASI ETAP 7.5 PADA PENYULANG SEMERU DI GARDU INDUK SIMPANG TIGA INDRALAYA
ANALISA PERHITUNGAN DROP TEGANGAN MENGGUNAKAN RUMUS DAN MENGGUNAKAN APLIKASI ETAP 7.5 PADA PENYULANG SEMERU DI GARDU INDUK SIMPANG TIGA INDRALAYA LAPORAN AKHIR Laporan akhir ini disusun sebagai salah satu
Lebih terperinciKajian Tentang Efektivitas Penggunaan Alat Penghemat Listrik
Kajian Tentang Efektivitas Penggunaan Alat Penghemat Listrik Rita Prasetyowati Jurusan Pendidikan Fisika-FMIPA UNY ABSTRAK Masyarakat luas mengenal alat penghemat listrik sebagai alat yang dapat menghemat
Lebih terperinciPERHITUNGAN ARUS GANGGUAN HUBUNG SINGKAT PADA JARINGAN DISTRIBUSI DI KOTA PONTIANAK
PERHTUNGAN ARUS GANGGUAN HUBUNG SNGKAT PADA JARNGAN DSTRBUS D KOTA PONTANAK Hendriyadi Program Studi Teknik Elektro Jurusan Teknik Elektro Fakultas Teknik Universitas Tanjungra adekhendri77@gmail.com Abstrak
Lebih terperinciANALISIS TEGANGAN JATUH SISTEM DISTRIBUSI LISTRIK KABUPATEN PELALAWAN DENGAN MENGGUNAKAN ETAP 7.5.0
ANALISIS TEGANGAN JATUH SISTEM DISTRIBUSI LISTRIK KABUPATEN PELALAWAN DENGAN MENGGUNAKAN ETAP 7.5.0 Andang Purnomo Putro *), Karnoto, and Bambang Winardi Jurusan Teknik Elektro, Universitas Diponegoro
Lebih terperinciEVALUASI LOSSES DAYA PADA SISTEM TRANSMISI 150 KV SUMATERA BARAT
EVALUASI LOSSES DAYA PADA SISTEM TRANSMISI 150 KV SUMATERA BARAT Rahmadhian (1), Ir. Cahayahati, MT (2), Ir. Ija Darmana, MT (2) (1) Mahasiswa dan (2) Dosen Jurusan Teknik Elektro, Fakultas Teknologi Industri,
Lebih terperinciPROYEKSI KEBUTUHAN ENERGI LISTRIK APJ PEKALONGAN TAHUN DENGAN MENGGUNAKAN SOFTWARE LEAP
PROYEKSI KEBUTUHAN ENERGI LISTRIK APJ PEKALONGAN TAHUN 2014-2018 DENGAN MENGGUNAKAN SOFTWARE LEAP Meigy Restanaswari Kartika *), Karnoto, and Bambang Winardi Jurusan Teknik Elektro Fakultas Teknik Universitas
Lebih terperinciBAB II TINJAUAN PUSTAKA
BAB II TINJAUAN PUSTAKA 2.1.Tinjauan Pustaka Semakin pesatnya pertumbuhan suatu wilayah menuntut adanya jaminan ketersediaannya energi listrik serta perbaikan kualitas dari energi listrik, menuntut para
Lebih terperinciAnalisa Sistem Distribusi 20 kv Untuk Memperbaiki Kinerja Sistem Distribusi Menggunakan Electrical Transient Analysis Program
Analisa Sistem Distribusi 20 kv Untuk Memperbaiki Kinerja Sistem Distribusi Menggunakan Electrical Transient Analysis Program Abrar Tanjung Jurusan Teknik Elektro Fakultas Teknik Universitas Lancang Kuning
Lebih terperinci