PEREKAYASAAN SISTEM DETEKSI PERANGKAT SCINTIGRAPHY MENGGUNAKAN PSPMT

dokumen-dokumen yang mirip
PEREKAYASAAN SISTEM DETEKSI PERANGKAT SCINTIGRAPHY MENGGUNAKAN PSPMT

FABRIKASI BAGIAN-BAGIAN PERANGKAT SCINTIGRAPHY UNTUK TIROID

DESAIN DASAR PERANGKAT SCINTIGRAPHY

PENGEMBANGAN MODUL CATU DAYA TEGANGAN TINGGI PERANGKAT SCINTIGRAFI UNTUK TIROID SC-12

FABRIKASI BAG IAN-BAG IAN PERANGKAT SCINTIGRAPHY

Jurnal Fisika Unand Vol. 3, No. 2, April 2014 ISSN

PERANGKAT LUNAK PELATIHAN PENCITRAAN PADA PERALATAN KAMERA GAMMA

PENGATUR CATU DAYA TEGANGAN TINGGI PERANGKAT MAMMOGRAFI MX-13 BERBASIS PULSE WIDTH MODULATION

ANALISIS STATIK RANGKA PEMEGANG PERISAI RADIASI PADA ALAT SCINTIGRAPHY MENGGUNAKAN SOFTWARE ANSYS

Jurnal Fisika Unand Vol. 3, No. 3, Juli 2014 ISSN

KOMPARASI UNJUK KERJA SPEKTROMETRI GAMMA DETEKTOR BICRON 2M2 DENGAN LUDLUM 44-62

STUDI AWAL UJI PERANGKAT KAMERA GAMMA DUAL HEAD MODEL PENCITRAAN PLANAR STATIK MENGGUNAKAN SUMBER RADIASI HIGH ENERGY IODIUM-131 (I 131 )

STUDI AWAL UJI PERANGKAT KAMERA GAMMA DUAL HEAD MODEL PENCITRAAN PLANAR (STATIK) MENGGUNAKAN SUMBER RADIASI MEDIUM ENERGY RADIUM-226 (Ra 226 )

ALAT UKUR RADIASI. Badan Pengawas Tenaga Nuklir. Jl. MH Thamrin, No. 55, Jakarta Telepon : (021)

Perbandingan Kinerja Detektor NaI(Tl) Dengan Detektor CsI(Tl) Pada Spektroskopi Radiasi Gamma

PRIMA Volume 3, Nomor 6, November 2006 ISSN

KOMPARASI UNJUK KERJA SPEKTROMETRI GAMMA MENGGUNAKAN DETEKTOR BICRON 2M2 DENGAN SPEKTROMETRI GAMMA MENGGUNAKAN DETEKTOR LUDLUM 44-62

SPEKTROSKOPI-γ (GAMMA)

KAJIAN KINERJA SISTEM DETEKSI ANTARA DETEKTOR NaI(Tl) DAN CsI(Tl) UNTUK PERANGKAT RENOGRAF PORTABEL JINJING

ANALISIS DOSIS YANG DITERIMA PASIEN PADA PEMERIKSAAN RENOGRAF

DETEKTOR RADIASI. NANIK DWI NURHAYATI, S.Si, M.Si nanikdn.staff.uns.ac.id

ANALISIS EFISIENSI PENDETEKSIAN RADIASI GAMMA OLEH SCINTILLATION COUNTER NaI(Tl) DITINJAU DARI ASPEK DIMENSI COUNTER

SPEKTROSKOPI-γ (GAMMA)

PENENTUAN TEBAL PERISAI RADIASI PERANGKAT RADIOTERAPI EKSTERNAL Co-60 UNTUK POSISI PENYINARAN

Prinsip Dasar Pengukuran Radiasi

SISTEM PENCACAH RADIASI DENGAN DETEKTOR SINTILASI BERBASIS MIKROKOMPUTER

Pengaruh Perubahan Tegangan Tinggi Tabung Photomultiplayer (PMT) Terhadap Amplitudo Keluaran Detektor NaI(Tl)

UJI LINE SCAN CAMERA PADA RANCANG BANGUN SISTEM PENCITRAAN PETI KEMAS DENGAN TEKNIK SERAPAN SINAR GAMMA

SISTEM PENCACAHAN RADIASI DENGAN DETEKTOR SINTILASI

PEREKAYASAAN SISTEM PENCITRAAN MATERIAL DI DALAM REAKTOR PETROKIMIA DENGAN TEKNIK SERAPAN SINAR GAMMA

Penentuan Efisiensi Beta Terhadap Gamma Pada Detektor Geiger Muller

PEMBUATAN LINEAR AMPLIFIER MENGGUNAKAN LM318 UNTUK SPEKTROMETRI GAMMA

PENINGKATAN KEMAMPUAN KAMERA GAMMA ANALOG MENGGUNAKAN SISTEM BERBASIS KOMPUTER PC DAN PENGEMBANGAN PERANGKAT LUNAK PENGOLAHAN CITRA

PENGARUH DIAMETER PHANTOM DAN TEBAL SLICE TERHADAP NILAI CTDI PADA PEMERIKSAAN MENGGUNAKAN CT-SCAN

PENGUKURAN DOSIS RADIASI RUANGAN RADIOLOGI II RUMAH SAKIT GIGI DAN MULUT (RSGM) BAITURRAHMAH PADANG MENGGUNAKAN SURVEYMETER UNFORS-XI

INOVASI ALAT PENGATUR CATU DAYA TEGANGAN TINGGI PADA PESAWAT SINAR-X DIAGNOSTIK

PEREKAYASAAN PENCACAH RIA IP10.1 UNTUK DIAGNOSIS KELENJAR GONDOK

ANALISIS PERHITUNGAN KETEBALAN PERISAI RADIASI PERANGKAT RIA IP10.

RANCANG BANGUN TEGANGAN TINGGI DC DAN PEMBALIK PULSA PADA SISTEM PENCACAH NUKLIR DELAPAN DETEKTOR

MAKALAH LENGKAP INSTRUMENTASI UNTUK PENCITRAAN KEDOKTERAN NUKLIR

UJI FUNGSI SISTEM SPEKTROMETER GAMMA MODEL : BEM - IN1001

INSTRUMEN UJI PENYAKIT GONDOK BERBASIS ISOTOP I 131

PERANCANGAN PERISAI RADIASI PADA KEPALA SUMBER UNTUK PESAWAT RADIOTERAPI EKSTERNAL MENGGUNAKAN CO-60 PADA POSISI BEAM OFF

Rancang Bangun Alat Gamma Scan Aktuator Ganda Berbasis Mikrokontroler. Design of Microcontroller Based Double Actuator Gamma Scanner

RANCANG BANGUN SISTEM KENDALI CONVEYOR PADA PROTOYPE MONITOR PETI KEMAS DENGAN TEKNIK SERAPAN SINAR GAMA

Youngster Physics Journal ISSN : Vol. 4, No. 1, Januari 2015, Hal 23-30

Sistem Pencacah dan Spektroskopi

UJI LAPANGAN PERANGKAT DETEKSI GAMMA DENSITY HASIL REKAYASA BATAN PADA INDUSTRI & PERTAMBANGAN

BAB I PENDAHULUAN. Radiasi seringkali dianggap sebagai sesuatu yang berbahaya dan tidak

ANALISIS WAKTU PELURUHAN TERHADAP PERSYARATAN DOSIS RADIOISOTOP UNTUK PEMERIKSAAN GONDOK

HUBUNGAN TEGANGAN DAN CITRA RADIOGRAFI REAL TIME PADA PESAWAT SINAR-X RIGAKU RADIOFLEX-250EGS3

PERANCANGAN PERANGKAT SINAR-X DIGITAL UNTUK DIAGNOSIS MEDIS

Penentuan Spektrum Energi dan Energi Resolusi β dan γ Menggunakan MCA (Multi Channel Analizer)

INOVASI ALAT PENGATUR CATU DAYA TEGANGAN TINGGI PADA PESAWAT SINAR-X DIAGNOSTIK

PERANCANGAN RUANGAN RADIOTERAPI EKSTERNAL MENGGUNAKAN SUMBER Co-60

SIMULASI KERJA PENGUAT AWAL SISTEM SPEKTROSKOPI NUKLIR DENGAN ISIS PROTEUS

STANDAR NASIONAL INDONESIA (SNI) BIDANG NUKLIR

PEREKAYASAAN SISTEM PENCITRAAN MATERIAL DIDALAM REAKTOR PETROKIMIA DENGAN TEKNIK SERAPAN SINAR GAMMA

TINJAUAN KEAMANAN DAN KESELAMATAN DALAM PEMANFAATAN PERALATAN RENOGRAF TERPADU

SISTEM DETEKSI MONITOR LINGKUNGAN

PERBANDINGAN DOSIS RADIASI DI UDARA TERHADAP DOSIS RADIASI DI PERMUKAAN PHANTOM PADA PESAWAT CT-SCAN

PERKEMBANGAN KEDOKTERAN NUKLIR DAN RADIOFARMAKA DI INDONESIA

BAB I PENDAHULUAN. 1.1 Latar Belakang

PENGARUH TANGGAPAN DETEKTOR KAMERA GAMMA SPECT PADA PEMERIKSAAN GINJAL

RANCANGAN PERANGKAT PEMANTAU RADIOAKTIVITAS LINGKUNGAN JARAK JAUH

III. METODE PENELITIAN. Penelitian ini akan dilaksanakan pada Juni 2014 sampai dengan Desember 2014.

PENGEMBANGAN SPEKTROMETER GAMMA PORTABEL BERBIAYA MURAH MENGGUNAKAN SOUND CARD USB

PEREKAYASAAN PERANGKAT PEMANTAU RADIASI LINGKUNGAN INSTALASI NUKLIR

PEMBUATAN COUNTER/TIMER UNTUK SISTEM SPEKTROMETER GAMMA MENGGUNAKAN MIKROKONTROLER AT89C52

DESKRIPSI FUNGSI DAN FITUR MEDICVIEW GAMMA PF USB 2 UNTUK PENCITRAAN KAMERA GAMMA. Sigit Bachtiar, Istofa, Lcli Yuniarsari, PRPN - BATAN

UNIVERSITAS INDONESIA UJI QUALITY CONTROL DETEKTOR PESAWAT SPECT DENGAN PROTOKOL IAEA DAN AAPM. Naskah Ringkas Skripsi

PENGEMBANGAN DETEKTOR GEIGER MULLER DENGAN ISIAN GAS ALKOHOL, METANA DAN ARGON

PENENTUAN KONSENTRASI AKTIVITAS URANIUM DARI INDUSTRI FOSFAT MENGGUNAKAN DETEKTOR ZnS(Ag)

INSTRUMENTASI NUKLIR KAMERA GAMMA

X-Ray Fluorescence Spectrometer (XRF)

PERANGKAT PENANGKAP CITRA SINAR-X BERBASIS LAYAR PENDAR

PERANCANGAN PERISAI RADIASI PADA KEPALA SUMBER UNTUK PESAWAT RADIOTERAPI EKSTERNAL MENGGUNAKAN CO-60 PADA POSISI BEAM OFF

PERANCANGAN RUANGAN RADIOTERAPI EKSTERNAL MENGGUNAKAN SUMBER Co-60

PENENTUAN CALIBRATION SETTING DOSE CALIBRATOR CAPINTEC CRC-7BT UNTUK Ce-139

DESAIN DAN PEMBUATAN PENDUKUNG MEKANIK PADA PROTOTIPE PERANGKAT SISTEM PENCITRAAN PETI KEMAS DENGAN TEKNIK SINAR GAMMA

BAB I PENDAHULUAN 1.1 Latar Belakang

PERANCANGAN DAN REALISASI WITNESS CAMERA DENGAN MEDIA PENYIMPANAN SDCARD ABSTRAK

Aplikasi Kamera Web Untuk Mengukur Luas Permukaan Sebuah Obyek 3D

ABSTRAK. Universitas Kristen Maranatha

PEMBUATAN TABUNG DETEKTOR GEIGER MULLER TIPE JENDELA SAMPING

LAPORAN PRAKTIKUM SPEKTROSKOPI XRF DENGAN DETEKTOR SEMIKODUKTOR Cd Te

FABRIKASI DETEKTOR PARTIKEL ALPHA MENGGUNAKAN SEMIKONDUKTOR SILIKON TIPE P

PENGARUH TEGANGAN TABUNG (KV) TERHADAP KUALITAS CITRA RADIOGRAFI PESAWAT SINAR-X DIGITAL RADIOGRAPHY (DR) PADA PHANTOM ABDOMEN

UNTUK MENGURANGI RESIKO RADIASI P ADA OPERATOR. Ferry Suyatno PRPN -BAT AN PEREKA YASAAN SISTEM PESA W AT SINAR-X FLUOROSCOPY

ANALISIS DIMENSI LENGAN PADA MODEL RANCANGAN RENOGRAF THYROID UPTAKE TERPADU

Berkala Fisika ISSN : Vol. 7, No. 3, Juli 2004, hal

SISTEM MONITORING MATERIAL CLOGGING PADA REAKTOR LOW LINIER DENSITY POLYETHYLENE DENGAN RADIASI GAMMA

DETEKTOR RADIASI INTI. Sulistyani, M.Si.

SIMULASI KURVA EFISIENSI DETEKTOR GERMANIUM UNTUK SINAR GAMMA ENERGI RENDAH DENGAN METODE MONTE CARLO MCNP5

SIMULASI PENGUKURAN EFFISIENSI DETEKTOR HPGe DAN NaI (Tl) MENGGUNAKAN METODE MONTE CARLO MCNP5

ANALISIS KENAIKAN HARGA AKTIVITAS KPK 01 CR001

Pusat Pendidikan dan Pelatihan Badan Tenaga Nuklir Nasional

RANCANG BANGUN PENGATUR CATU DAYA TEGANGAN TINGGI DC BERBASIS MIKROKONTROLER AT89C52

RANCANGAN KONTROL GERAKAN SAMPLE CHANGER BERBASIS USB PADA PERANGKAT RADIOIMMUNOASSAY-RIA IP8.

PEREKAYASAAN PERANGKAT PENANGKAP CITRA SINAR-X BERBASIS LAYAR PENDAR

Transkripsi:

PEREKAYASAAN SISTEM DETEKSI PERANGKAT SCINTIGRAPHY MENGGUNAKAN PSPMT Wiranto Budi Santoso 1 dan Leli Yuniarsari 1 1 Pusat Rekayasa Perangkat Nuklir - Badan Tenaga Nuklir Nasional ABSTRAK PEREKAYASAAN SISTEM DETEKSI PERANGKAT SCINTIGRAPHY MENGGUNAKAN PSPMT. Telah dilakukan perekayasaan sistem deteksi perangkat scintigraphy menggunakan PSPMT. Perangkat scintigraphy merupakan perangkat untuk pencitraan organ tubuh berukuran kecil. Perangkat ini merupakan kamera gamma dalam bentuk mini. Perangkat ini berfungsi untuk menghasilkan citra proses metabolisme suatu organ tubuh. Keluaran dari perangkat ini digunakan untuk diagnosis suatu penyakit. Sistem deteksi perangkat scintigraphy berfungsi untuk mendeteksi radiasi dari organ tubuh. Radiasi yang datang akan diubah menjadi foton oleh kristal sintilasi yang terdapat pada sistem deteksi perangkat scintigraphy. Kemudian foton tesebut akan digandakan oleh tabung pengganda foton (Photo Multiplier Tube PMT) dan diubah menjadi sinyal listrik. Diperlukan banyak PMT untuk mendeteksi lokasi datangnya radiasi dari organ tubuh. Dengan menggunakan PSPMT (Position Sensitive PMT) yang sensitif terhadap posisi datangnya radiasi, hanya diperlukan satu PSPMT. Dari kegiatan yang dilakukan dapat disimpulkan bahwa sistem deteksi perangkat scintigraphy dapat menggunakan PSPMT. Dengan menggunakan PSPMT, dimensi sistem deteksi perangkat scintigraphy dapat diperkecil. Namun sistem deteksi hanya cocok digunakan untuk mencitrakan organ yang kecil. Kata Kunci : scintigraphy, kamera gamma, PSPMT ABSTRACT THE ENGINEERING OF A SCINTIGRAPHY EQUIPMENT DETECTION SYSTEM USING PSPMT. The engineering of scintigraphy equipment detection system using PSPMT has been conducted. A scintigraphy equipment is used for imaging small organs. The equipment is a mini gamma camera. The function of the equipment to provide images of metbolism process in a body organ. The result of the equipment can be used to diagnose an illness. The function of scintigraphy equipment detection system is detecting incoming radiation from body organs. The incoming radiations are converted to photons by a scintillation crystal in the scintigraphy equipment detection system. Then, photons are multiplied by Photo Multiplier Tube (PMT) and are converted to be electrical signals. It needs a lot of PMT to detect a location of incoming radiation from a body organ. Using PSPMT (Position Sensitive PMT) which sensitive to position of incoming radiation, it needs only one PSPMT. From this activity, it can be concluded that PSPMT can be used for scintigraphy equipment detection system. Using PSPMT, the dimension of scintigraphy equipment detection system can be reduced. Although the scintigraphy equipment detection system is only suitable for imaging small organs. Keywords: scintigraphy, gamma camera, PSPMT 1. PENDAHULUAN Diagnosis penyakit dengan memanfaatkan teknologi nuklir telah banyak dilakukan. Salah satunya adalah dengan menggunakan perangkat scintigraphy. Perangkat scintigraphy atau lebih dikenal dengan kamera gamma merupakan perangkat diagnosis metabolisme dalam suatu organ tubuh. Permasalahan yang dihadapi oleh rumah sakit di Indonesia dalam penggunaan perangkat scintigraphy ini adalah kebanyakan perangkat tersebut telah berumur tua, berdimensi besar, dan memerlukan daya listrik yang besar [1]. Besarnya dimensi perangkat scintigraphy ini disebabkan perangkat ini menggunakan banyak tabung pengganda foton (Photo Multiplir Tube - PMT) pada sistem deteksi. Dimensi dari 57

sistem deteksi perangkat scintigraphy dapat diperkecil dengan mengurangi jumlah PMT yang digunakan pada sistem deteksi. Pengurangan ini dapat dilakukan dengan penggunaan tabung pengganda foton yang sensitif terhadap posisi datangnya foton (Position Sensitive Photo Multiplir Tube - PSPMT). Dengan pengurangan jumlah PMT yang digunakan, berarti jumlah komponen listrik pendukung PMT tersebut juga berkurang. Dengan demikian selain dimensi dari sistem deteksi tersebut dapat diperkecil, konsumsi daya listrik dari perangkat scintigraphy secara keseluruhan dapat dihemat. PSPMT yang digunakan pada perekayasaan perangkat scintigraphy ini berdiameter 3 inchi. Dengan ukuran diameter tersebut, sistem deteksi perangkat scintigraphy ini hanya dapat digunakan untuk mendiagnosis organ tubuh berukuran kecil seperti: paru-paru, ginjal, hati, dan jantung. 2. TEORI 2.1. Perangkat Scintigraphy Perangkat scintigraphy berfungsi untuk mendeteksi sinar gamma yang dipancarkan oleh radionuklida dalam organ tubuh sesuai dengan proses metabolisme yang terjadi pada organ tersebut [2]. Proses pencitraan menggunakan perangkat scintigraphy dilakukan dengan menyuntikkan radionuklida ke dalam tubuh pasien. Setelah itu sistem deteksi perangkat scintigraphy diposisikan di atas organ yang akan diamati proses metabolismenya. Proses pencitraan menggunakan perangkat scintigraphy dapat dilihat pada gambar 1. Gambar 1. Proses pencitraan menggunakan perangkat scintigraphy [3]. Perangkat scintigraphy terdiri dari kolimator, kristal scintilasi, tabung pengganda foton (Photomultiplier Tubes PMT), rangkaian logika posisi, dan komputer penganalisis data [2]. Bagian kolimator, kristal scintilasi, tabung pengganda foton, dan rangkaian logika posisi dikelompokkan ke dalam sistem deteksi perangkat scintigraphy. Sistem deteksi perangkat scintigraphy berfungsi untuk mendeteksi posisi radiasi yang datang datang dari organ tubuh. Kolimator akan membatasi radiasi yang datang hanya dari organ tubuh yang akan diobservasi. Setelah mengenai kristal scintilasi, radiasi akan diubah menjadi foton. Foton yang dihasilkan akan sebanding dengan intensitas radiasi yang datang. Selanjutnya foton tersebut akan diperbanyak oleh tabung pengganda foton (PMT). Kemudian PMT akan mengubah foton menjadi sinyal listrik. Sinyal listrik ini diteruskan ke rangkaian logika posisi untuk ditentukan koordinat posisi datangnya radiasi. 2.2. PSPMT PSPMT terdiri dari fotokatoda, dinoda (dynodes), dan anoda yang tersusun secara ortogonal X dan Y. Keluaran anoda dihubungkan ke untai resistor pembagi tegangan. Untai resistor pembagi tegangan menghasilkan keluaran XA, XB, YC, dan YD. Elektron yang dipancarkan dari fotokatoda akan menumbuk dinoda 58

sehingga menghasilkan elektron sekunder. Awan elektron yang dihasilkan oleh dinoda terakhir akan dikumpulkan oleh anoda dan didistribusikan pada ke empat ujung untai pembagi tegangan (QXA, QXB, QYC, dan QYD). Hubungan antara posisi datangnya cahaya dengan distribusi muatan yang dihasilkan dapat dilihat pada gambar 2. Gambar 2. Distribusi muatan PSPMT [3]. 3. METODE Pembuatan sistem deteksi perangkat scintigraphy dilakukan dengan tahapan-tahapan sebagai berikut: - Penetapan persyaratan desain dan teknis dari perangkat scintigrapy. Pada tahap ini ditetapkan persyaratan desain yang harus dipenuhi oleh perangkat scintigraphy yang akan dibuat. Dari persyaratan desain ini ditetapkan persyaratan teknis yang harus dipenuhi oleh perangkat scintigraphy. - Pembuatan desain sistem deteksi perangkat scintigraphy scintigraphy yang akan dibuat dirancang dengan memperhatikan persyaratan desain dan teknis dari perangkat scintigrapy. - Pembuatan sistem deteksi perangkat scintigraphy scintigraphy yang akan dibuat terdiri dari kristal scintilasi NaI(Tl), PSPMT, kolimator dan shielding, dan rangkaian untai resistor. - Pengujian sistem deteksi perangkat scintigraphy Pengujian sistem deteksi perangkat scintigraphy yang dibuat dilakukan untuk memastikan bahwa sistem deteksi dapat berfungsi sesuai dengan yang diinginkan. 4. HASIL DAN PEMBAHASAN Hasil perekayasaan sistem deteksi perangkat scintigraphy diuraikan berikut ini. Perekayasaan sistem deteksi perangkat scintigraphy mengacu pada persyaratan desain dan persyaratan teknis dari desain dasar perangkat scintigraphy [1]. scintigraphy Desain dasar perangkat scintigraphy juga menjadi acuan pada desain sistem deteksi perangkat scintigraphy. Perangkat scintigraphy yang akan direkayasa didesain terdiri dari: modul sistem deteksi, sistem elektronik, dan sistem pengolah data. Blok diagram dari Perangkat scintigraphy yang akan direkayasa diperlihatkan pada gambar 3. Gambar 3. Blok diagram perangkat scintigraphy [4]. scintigraphy terdiri dari: kristal scintilasi, tabung pengganda foton sensitif terhadap posisi (Position Sensitive Photomultiplier Tube PSPMT), dan untai resistor (resistor chain). Blok diagram sistem deteksi perangkat scintigraphy dapat dilhat pada gambar 4. 59

Gambar 4. Blok diagram sistem deteksi perangkat scintigraphy. Gambar 6. Untai resistor Kristal scintilasi Kristal scintilasi berfungsi untuk mengubah radiasi yang datang menjadi foton. Kristal scintilasi yang akan digunakan adalah NaI(Tl). PSPMT PSPMT merupakan tabung pengganda foton yang sensitif terhadap posisi. PSPMT berfungsi untuk menggandakan foton. Selain itu, PSPMT bersama-sama dengan untai resistor pembagi tegangan menghasilkan koordinat X dan Y dari radiasi yang datang. PSPMT yang digunakan adalah PSPMT tipe R2486 dari Hamamatsu. Gambar 7. Blok diagram penentuan koordinat posisi pada PSPMT Berdasarkan desain yang telah dibuat, dilakukan pembuatan sistem deteksi perangkat scintigraphy. Sistem deteksi perangkat scintigraphy yang dihasilkan dapat dilihat pada gambar 8. Gambar 5. PSPMT Hamamatsu R2486 Untai resistor (Resistor chain) Untai resistor berfungsi untuk memberikan bobot terhadap posisi datangnya radiasi pada detektor. Keluaran dari untai resistor ini dapat digunakan untuk menentukan koordinat posisi dari radiasi yang datang. Gambar 8. scintigraphy yang dihasilkan Pengujian Pengujian sistem deteksi perangkat scintigraphy dilakukan untuk mengetahui respon sistem deteksi terhadap radiasi. Radiasi yang digunakan berasal dari sumber standar. 60

Blok diagram pengujian sistem deteksi perangkat scintigraphy dapat dilihat pada gambar 9. Tabel 2. Amplitudo sinyal sistem deteksi terhadap posisi sumber. Gambar 9. Blok diagram pengujian sistem deteksi perangkat scintigraphy Hasil pengujian sistem deteksi dapat dilihat pada tabel-tabel berikut ini. Gambar 10. Sinyal keluaran dari sistem deteksi perangkat scintigraphy Tabel 1. Pengujian bentuk dan tegangan pulsa keluaran sistem deteksi terhadap catudaya tegangan tinggi. 5. KESIMPULAN. Telah dihasilkan sistem deteksi perangkat scintigraphy dengan mengunakan PSPMT. Dari kegiatan ini dapat disimpulkan bahwa: 1. Sistem deteksi menggunakan PSPMT dapat mendeteksi posisi sumber radiasi. 2. Dengan menggunakan PSPMT, dimensi sistem deteksi perangkat scintgraphy dapat diperkecil. 3. Sistem deteksi menggunakan PSPMT hanya cocok digunakan untuk mencitrakan organ tubuh yang kecil. 6. UCAPAN TERIMA KASIH Penulis mengucapkan terima kasih kepada Kepala PRPN yang telah memberikan izin untuk menggunakan fasilitas serta peralatan untuk melakukan kegiatan ini. Tak lupa penulis juga mengucapkan terima kasih kepada pihak-pihak yang telah membantu pelaksanaan kegiatan ini, terutama rekan-rekan di Bidang Instrumentasi Kesehatan dan Keselamatan, PRPN BATAN. 61

7. DAFTAR PUSTAKA [1]. Wiranto Budi Santoso, Desain Dasar Perangkat Scintigraphy, Jurnal Perangkat Nuklir Volume 05 Nomor 01, pp 42-50 (2011) [2]. IAEA, Quality Control of Nuclear Medicine Instruments 1991 (IAEA-TECDOC-317), IAEA, Vienna (1991) [3]. IAEA, Quality Control of Nuclear Medicine Instruments (IAEA-TECDOC-317), IAEA, Vienna (1984) [4]. Hamamatsu, Position Sensitive Photomultiplier Tube with Crossed Wire Anodes R2486 Series, December 2001 62