Rojul Gayuh Leksono et al., Analisis dan Pengujian Batang Elemen Struktur Beton Bertulang Berlubang 1

dokumen-dokumen yang mirip
ANALISIS DAN PENGUJIAN BATANG ELEMEN STRUKTUR BETON BERTULANG BERLUBANG PENAMPANG LINGKARAN TERHADAP BEBAN LENTUR SKRIPSI

ANALISIS DAN PENGUJIAN PERILAKU DARI VARIASI LUBANG PADA BATANG ELEMEN STRUKTUR BETON BERTULANG PENAMPANG PERSEGI TERHADAP BEBAN LENTUR

Resty Rekmala., Pengujian Serta Analisis Perilaku Elemen Tekan Persegi Berkubang (Hollow) Terhadap 1

PENGARUH JARAK SENGKANG TERHADAP KAPASITAS BEBAN AKSIAL MAKSIMUM KOLOM BETON BERPENAMPANG LINGKARAN DAN SEGI EMPAT

Naskah Publikasi. untuk memenuhi sebagian persyaratan mencapai derajat Sarjana-1 Teknik Sipil. diajukan oleh : BAMBANG SUTRISNO NIM : D

BAB I PENDAHULUAN Latar Belakang. Dalam bidang konstruksi, beton dan baja saling bekerja sama dan saling

METODE PENGUJIAN KUAT LENTUR NORMAL DENGAN DUA TITIK PEMBEBANAN BAB I DESKRIPSI

BAB I PENDAHULUAN A. Latar Belakang

STUDI EKSPERIMEN KAPASITAS TARIK DAN LENTUR PENJEPIT CONFINEMENT KOLOM BETON

INFRASTRUKTUR PENGARUH LUBANG DAN EKSENTRISITAS TERHADAP KUAT TEKAN BETON. Influence of Hole and Eccentricity on Concrete Compressive Strength

KUAT LENTUR BALOK BETON TULANGAN BAMBU PETUNG VERTIKAL

BAB I PENDAHULUAN. 1.1 Latar Belakang. Perkembangan pada setiap bidang kehidupan pada era globalisasi saat ini

ANALISIS DAN PENGUJIAN BATANG ELEMEN STRUKTUR BETON BERTULANG BERLUBANG PENAMPANG PERSEGI TERHADAP BEBAN LENTUR SKRIPSI

BAB I PENDAHULUAN. meningkat dibandingkan beberapa tahun sebelumnya. Perkembangan yang. perkuatan untuk elemen struktur beton bertulang bangunan.

ANALISIS KUAT GESER STRUKTUR BALOK BETON BERTULANG DENGAN LUBANG HOLLOW CORE PADA TENGAH PENAMPANG BALOK NASKAH PUBLIKASI TEKNIK SIPIL

PENGARUH VARIASI LUAS PIPA PADA ELEMEN KOLOM BETON BERTULANG TERHADAP KUAT TEKAN

PENGARUH VARIASI LUAS PIPA PADA ELEMEN BALOK BETON BERTULANG TERHADAP KUAT LENTUR

TINJAUAN KUAT LENTUR BALOK BETON BERTULANG DENGAN PENAMBAHAN KAWAT YANG DIPASANG LONGITUDINAL DI BAGIAN TULANGAN TARIK.

INFRASTRUKTUR KAPASITAS LENTUR BALOK BETON BERTULANG DENGAN MENGGUNAKAN AGREGAT KASAR TEMPURUNG KELAPA

BAB I PENDAHULUAN A. Latar Belakang

BAB I PENDAHULUAN A. Latar Belakang

BAB IV HASIL EKSPERIMEN DAN ANALISIS

PERBANDINGAN KUAT TARIK LENTUR BETON BERTULANG BALOK UTUH DENGAN BALOK YANG DIPERKUAT MENGGUNAKAN CHEMICAL ANCHOR

PENGARUH JARAK SENGKANG PADA PEMASANGAN KAWAT GALVANIS MENYILANG TERHADAP KUAT LENTU BALOK BETON BERTULANG

Kata Kunci : beton, baja tulangan, panjang lewatan, Sikadur -31 CF Normal

PENGUJIAN GESER BALOK BETON BERTULANG DENGAN MENGGUNAKAN SENGKANG KONVENSIONAL

PERBANDINGAN KUAT TEKAN BETON MENGGUNAKAN AGREGAT JENUH KERING MUKA DENGAN AGREGAT KERING UDARA

BAB III LANDASAN TEORI

PENGUJIAN DAN ANALISIS PERILAKU ELEMEN TEKAN SILINDER BERLUBANG (HOLLOW) TERHADAP KAPASITAS MENAHAN BEBAN AKSIAL SKRIPSI

BAB I PENDAHULUAN. Ada tiga jenis bahan bangunan yang sering digunakan dalam dunia

Kajian Perilaku Lentur Perbaikan Balok Beton Bertulang dengan Metode External Prestressing

BAB I PENDAHULUAN A. Latar Belakang

STUDI EKSPERIMENTAL PENGARUH PENGGUNAAN PS BALL SEBAGAI PENGGANTI PASIR TERHADAP KUAT LENTUR BETON

BAB I PENDAHULUAN 1.1. Latar Belakang

BAB I PENDAHULUAN. 1.1 Latar Belakang. Pada masa sekarang, dapat dikatakan penggunaan beton dapat kita jumpai

MATERI/MODUL MATA PRAKTIKUM

BAB I PENDAHULUAN Latar Belakang. Di zaman sekarang, perkembangan ilmu dan teknologi pada setiap bidang

TINJAUAN REKAYASA PENULANGAN GESER BALOK BETON BERTULANG DENGAN SENGKANG VERTIKAL MODEL U

BAB III LANDASAN TEORI

PENELITIAN BALOK BETON BERTULANG DENGAN DAN TANPA PEMAKAIAN SIKAFIBRE

REKAYASA PENULANGAN GESER BALOK BETON BERTULANG DENGAN MENGGUNAKAN SENGKANG VERTIKAL MODEL U

BAB I PENDAHULUAN. dengan banyaknya dilakukan penelitian untuk menemukan bahan-bahan baru atau

BAB 3 METODOLOGI. Penelitian ini dimulai dengan mengidentifikasi masalah apa saja yang terdapat

BAB IV ANALISIS DATA DAN HASIL PENELITIAN

BAB I PENDAHULUAN. pozolanik) sebetulnya telah dimulai sejak zaman Yunani, Romawi dan mungkin juga

BAB I PENDAHULUAN. banyak diterapkan pada bangunan, seperti: gedung, jembatan, perkerasan jalan, balok, plat lantai, ring balok, ataupun plat atap.

BAB I PENDAHULUAN Latar Belakang. Dunia konstruksi bangunan di Indonesia saat ini mengalami perkembangan

TINJAUAN KUAT LENTUR BALOK BETON DENGAN TULANGAN MODEL RANGKA DARI KAYU MERANTI DENGAN VARIASI JARAK ANTAR BEGEL

Pengaruh Luas Lubang Pipa Pada Kolom Pendek Dengan Variasi Diameter Lubang Pipa 1½, 2, 2½ Dan 3.

BAB I PENDAHULUAN 1.1 LATAR BELAKANG

Jhohan Ardiyansyah, et al.penentuan Lendutan Pelat Beton Bertulang Bambu dan Baja...

KUAT LENTUR PROFIL LIPPED CHANNEL BERPENGAKU DENGAN PENGISI BETON RINGAN BERAGREGAT KASAR AUTOCLAVED AERATED CONCRETE HEBEL

BAB I PENDAHULUAN. ekonomis, lebih tahan akan cuaca, lebih tahan korosi dan lebih murah. karena gaya inersia yang terjadi menjadi lebih kecil.

PENGUJIAN LENTUR BALOK BETON BERTULANG DENGAN MENGGUNAKAN MODIFIKASI ALAT UJI TEKAN

Desain Penampang Struktur Beton dengan SAPCON. Contoh Aplikasi SAPCON untuk Struktrur Frame 2D.

BAB 1 PENDAHULUAN A. Latar Belakang

PERBANDINGAN KUAT TEKAN DAN KUAT LENTUR BAHAN TAMBAH PLASTIK DAN ABU SEKAM PADI DALAM PEMBUATAN BETON RINGAN

METODE PENGAMBILAN DAN PENGUJIAN BETON INTI

I. PENDAHULUAN. Pekerjaan struktur seringkali ditekankan pada aspek estetika dan kenyamanan

Gambar 1 PENGARUH KONFIGURASI BAJA DAN FAKTOR KELANGSINGAN TERHADAP KAPASITAS TEKAN KOLOM

BAB I PENDAHULUAN A. Latar Belakang Masalah

PERILAKU LENTUR KOLOM BETON PIPIH DENGAN TULANGAN BAMBU

PERBANDINGAN UJI TARIK LANGSUNG DAN UJI TARIK BELAH BETON

BAB I PENDAHULUAN. digunakan di Indonesia dalam pembangunan fisik. Karena sifat nya yang unik. pembuatan, cara evaluasi dan variasi penambahan bahan.

BAB I PENDAHULUAN. 1.1 Latar Belakang

PENGUJIAN KUAT LENTUR PANEL PELAT BETON RINGAN PRACETAK BERONGGA DENGAN PENAMBAHAN SILICA FUME

TINJAUAN KUAT GESER KOMBINASI SENGKANG ALTERNATIF DAN SENGKANG U ATAU n DENGAN PEMASANGAN SECARA VERTIKAL PADA BALOK BETON SEDERHANA

Kajian Eksperimental Perilaku Lentur dan Geser Balok Sandwich Beton

PENGARUH PENGGUNAAN SERBUK KACA SEBAGAI BAHAN SUBSTITUSI AGREGAT HALUS TERHADAP SIFAT MEKANIK BETON

JURNAL REKAYASA SIPIL DAN LINGKUNGAN Jurnal Teoritis dan Terapan Bidang Rekayasa Ketekniksipilan dan Lingkungan

TINJAUAN KUAT GESER DAN KUAT LENTUR BALOK BETON ABU KETEL MUTU TINGGI DENGAN TAMBAHAN ACCELERATOR

TINJAUAN KUAT LENTUR BALOK BETON BERTULANG BAJA DENGAN PENAMBAHAN KAWAT YANG DIPASANG DIAGONAL DI TENGAH TULANGAN SENGKANG.

TINJAUAN KUAT TEKAN DAN KERUNTUHAN BALOK BETON BERTULANG MENGGUNAKAN TRAS JATIYOSO SEBAGAI PENGGANTI PASIR. Naskah Publikasi

KERUNTUHAN LENTUR BALOK PADA STRUKTUR JOINT BALOK-KOLOM BETON BERTULANG EKSTERIOR AKIBAT BEBAN SIKLIK

PERBANDINGAN KUAT LENTUR DUA ARAH PLAT BETON BERTULANGAN BAMBU RANGKAP LAPIS STYROFOAM

TINJAUAN KUAT LENTUR PLAT LANTAI MENGGUNAKAN TULANGAN WIRE MESH DENGAN PENAMBAHAN POLYVINYL ACETAT

STUDI EKSPERIMENTAL DAN ANALITIS KAPASITAS SAMBUNGAN BAJA BATANG TARIK DENGAN TIPE KEGAGALAN GESER BAUT

STUDI EKSPERIMENTAL KUAT LENTUR PADA BALOK BETON BERTULANG DENGAN PERKUATAN BAJA RINGAN PROFIL U

Campuran Beton terhadap Kuat Tekan

PENGUJIAN KUAT LENTUR BALOK BETON BERTULANG DENGAN VARIASI RATIO TULANGAN TARIK

KAJIAN PERILAKU LENTUR PELAT KERAMIK BETON (KERATON) (064M)

STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM PERSEGI BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP ABSTRAK

BAB 1. PENGENALAN BETON BERTULANG

BAB IV ANALISA STRUKTUR

BAB 4 HASIL DAN ANALISA

Pengajar Fakultas Teknik, Program Studi Teknik Sipil Universitas Sebelas Maret 3)

EVALUASI KAPASITAS KOLOM BETON BERTULANG YANG DIPERKUAT DENGAN METODE CONCRETE JACKETING

MODIFIKASI PERENCANAAN GEDUNG RUMAH SAKIT ROYAL SURABAYA MENGGUNAKAN STRUKTUR KOMPOSIT BAJA-BETON

PERKUATAN KOLOM BETON BERTULANG DENGAN GLASS FIBER JACKET UNTUK MENINGKATKAN KAPASITAS BEBAN AKSIAL (034S)

Pengaruh Penggunaan Bambu Sebagai Pengganti Agregat Split terhadap Kuat Tekan Beton Ringan

Spesifikasi Pipa Beton untuk Air Buangan, Saluran Peluapan dari Gorong-Gorong

Pengaruh Variasi Tebal Terhadap Kekuatan Lentur Pada Balok Komposit Menggunakan Response 2000

KAPASITAS LENTUR BALOK BETON TULANGAN BAMBU PETUNG DENGAN TAKIKAN TIDAK SEJAJAR TIPE U LEBAR 1 CM DAN 2 CM PADA TIAP JARAK 5 CM

PERILAKU BALOK BERTULANG YANG DIBERI PERKUATAN GESER MENGGUNAKAN LEMBARAN WOVEN CARBON FIBER

STUDI EKSPERIMENTAL PENGARUH PENGGUNAAN STELL FIBER TERHADAP UJI KUAT TEKAN, TARIK BELAH DAN KUAT LENTUR PADA CAMPURAN BETON MUTU f c 25 MPa

KUAT LENTUR BALOK BETON TULANGAN BAMBU PETUNG VERTIKAL TAKIKAN TIPE U LEBAR 3 CM TIAP JARAK 10 CM

Kajian Pengaruh Panjang Back Span pada Jembatan Busur Tiga Bentang

STUDI EKSPERIMENTAL PERBAIKAN KOLOM LINGKARAN BETON BERTULANG ABSTRAK

III. METODE PENELITIAN

BAB 3 METODE PENELITIAN

Transkripsi:

Rojul Gayuh Leksono et al., Analisis dan Batang Elemen Struktur Beton Bertulang Berlubang 1 PENGUJIAN KAPASITAS LENTUR BATANG ELEMEN STRUKTUR BETON BERTULANG BERLUBANG PENAMPANG LINGKARAN (Testing of Bending Capacity of Beam Element of Hollow Reinforced Concrete Structure with Circular Section ) Rojul Gayuh Leksono, Ketut Aswatama, ErnoWidayanto, Teknik Sipil, Fakultas Teknik, Universitas Jember (UNEJ) Jln. Kalimantan 37, Jember 68121 E-mail: gayuhrojul@gmail.com Abstrak Dalam SNI 03-2847-2002 tercantum peraturan bahwa luas lubang pada batang elemen struktur beton tidak boleh melebihi 4% dari luas total penampang beton, hal ini untuk menjamin dan mempertahankan kekuatan batang elemen struktur beton. Jika lubang tersebut melebihi dari 4%, maka besarnya lubang terhadap kekuatan batang elemen struktur beton harus diperhitungkan. Dengan adanya lubang pada batang elemen struktur beton dapat dipastikan bahwa kekuatan batang elemen struktur beton dalam menerima beban aksial. Penelitian ini akan menganalisa dan menguji kekuatan batang elemen beton berlubang terhadap beban lentur. Terdapat 10 beton penampang lingkaran yang akan dibuat dalam pengujian. Beton ini memiliki diameter 16 cm dan tinggi 70cm. Empat di antara 10 beton ini akan dilubangi dengan pipa berukuran ¾, 1, 1 ¼, dan 1 ½. Mutu beton yang digunakan adalah 29,28 Mpa, selain itu diameter tulangan utama adalah 8 mm sebanyak 8 buah dan diameter tulangan sengkang adalah 6 mm sebanyak 8 buah. Data lain yang digunakan pada penelitian ini adalah kuat tarik baja. Kuat tarik baja 8 mm sebesar 314,549 Mpa dan kuat tarik baja 6 mm sebesar 230,029 Mpa. Hasil pengujian dan analisis menunjukkan bahwa semakin besar lubang yang dimiliki oleh beton maka reduksi kuat lentur pada beton akan semakin besar pula. Dari hasil analitis, reduksi terbesar adalah sebanyak 25% dari kuat beton tanpa lubang dan reduksi terkecil adalah 15%. Sementara itu, dari hasil pengujian,, reduksi terbesar adalah 18% dan reduksi yang terkecil adalah 7 %. Kata Kunci: Beton, Lubang, Kapasitas Lentur. Abstract In SNI 03-2847-2002, there is regulation stated that the area of the hole on rod element concrete structure may never be exceeded 4% of the total area of the concrete, this is to ensure and maintain the strength of the rod element concrete structure. If the hole exceeds 4%, the size of the hole to the strength of the rod element concrete structure must be taken into account. With the hole in the rod element concrete structure can be ensured that the strength of this element in accepting the axial loads. This study will analyze and test the strength of the rod element concrete hollow to bending loads. There are 10 concretes with circular cross section that will be made on the testing. These concretes have a diameter of 16 cm and a height of 70 cm. 4 among these 10 concretes will be perforated with pipe size ¾, 1, 1 ¼, dan 1 ½. The concrete strength used in the test is 29,28 MPa. In addition, there are 8 units of main reinforcements with a diameter of 8 mm and 8 units of stirrups with a diameter of 6 mm. Another data used in this study is the tensile strength of the steel. The tensile strength of the 8 mm st eel is 314,549 MPa and tensile strength of the 6 mm steel is 230,029 MPa. The test results and the analysis indicate that the larger hole owned by concrete, the reduction in flexural strength of concrete will be greater too. From the analytical results, the largest reduction is 25% of the concrete strength without holes and the smallest reduction is 15%. Meanwhile, from the test results, the largest reduction is 18% and the smallest reduction is 7%. Keywords:Concrete, Hollow, Bending Capacity

2 Rojul Gayuh Leksono et al., Analisis dan Batang Elemen Struktur beton Beton dilakukan Bertulang di Laboratorium Berlubang Fakultas Teknik Universitas Jember. Beton dilakukan dengan menggnakan alat uji beton dengan kapasitas tekan PENDAHULUAN sebesar 150 ton. Menurut SK.SNI T-15-1990-03: 1 beton adalah campuran antara semen portland atau semen hidrolik yang lainnya, agregat kasar, agregat halus, dan air, dengan atau tanpa bahan tambahan membentuk massa padat. Dalam peraturan SNI 03-2847-2002 tercantum peraturan bahwa luasan lubang pada batang elemen struktur beton tidak boleh melibihi 4% dari luas total penampang beton, hal ini dimaksudkan untuk menjamin dan mempertahankan kekuatan batang elemen struktur beton. Jika lubang pada batang elemen struktur beton melebihi dari 4%, maka besarnya lubang harus diperhitungkan terhadap kekuatan batang elemen struktur beton. Dengan adanya lubang pada batang elemen struktur beton dapat dipastikan bahwa kekuatan pada batang elemen struktur beton, baik kekuatan batang elemen struktur beton dalam menerima beban aksial, beban lentur, dan beban geser akan berkurang. Penelitian ini akan melakukan pengujian kapasitas lentur batang elemen struktur beton bertulang penampang lingkaran. Di mana dalam penelitian ini menggunakan sepuluh jenis benda uji untuk membandingkan sifat dan kinerjanya antara lain sebuah batang elemen struktur beton bulat tak berlubang dengan sengkang (Benda uji I), dua buah batang elemen struktur beton bulat dengan ukuran lubang 2,48% dari luas penampangnya (Benda uji II dan III) dengan sengkang, dua buah batang elemen struktur beton bulat dengan ukuran lubang lebih 3,76% dari luas penampang dengan sengkang (Benda uji IV dan V), dua buah batang elemen struktur beton bulat dengan ukuran lubang kurang dari 6,48% dari luas penampang dengan sengkang (Benda Uji VI dan VII), dan dua buah batang elemen struktur beton bulat dengan ukuran lubang 8,46% dari luas penampang dengan sengkang (Benda Uji VIII dan IX). METODOLOGI PENELITIAN Umum Untuk menguji beban lentur pada benda uji, dalam penelitian ini digunakan sebuah alat penekan beton yang dimiliki oleh jurusan teknik sipil. Alat ini dapat menguji kekuatan lentur dan geser pada suatu, beban yang mampu diberikan alat ini untuk benda uji adalah sebesar seratus lima puluh kilo newton (150 kn) Benda uji yang akan diuji dengan alat ini berupa beton bertulang penampang bulat dengan ukuran diameter penampang lingkaran 16 cm dan panjang beton bertulang penampang bulat tujuh puluh centimeter (70 cm). Penentuan Benda Uji Benda uji yang digunakan adalah beton dengan dimensi diameter 16 cm dan tinggi 70 cm. Benda uji yang disiapkan adalah 10 buah yang dibedakan menjadi 2 macam yaitu beton berlubang dan beton massive. Penggunaan tulangan pada beton adalah tulangan diameter 8 mm untuk tulangan utama dan 6 mm untuk tulangan sengkang. Beton yang digunakan adalah beton mutu normal. Beton Pengambilan Data Data yang diambil dalam penelitian ini adalah besarnya beban maksimum yang diterima beton hingga beton mengalami retak. Setting Beton Pada pengujian ini beton akan diletakkan tertidur atau diletakkan arah horizontal dari tumpuan dan beban. Gambar 1. Setting Benda uji Variabel Penelitian Dalam penelitian ini terdapat dua macam variabel yang diharakan didapatkan yakni : a. Variabel independen (variabel yang mempengaruhi) yaitu meliputi variasi ukuran pada lubang pada benda uji. b. Variasi dependent yang meliputi besarnya gaya lentur maksimum yang dapat diterima beton bertulang penampang bulat. Flow Chart Metode Penelitian Gambar 2. Flow Chart Penelitian

Rojul Gayuh Leksono et al., Analisis dan Batang Elemen Struktur Beton Bertulang Berlubang HASIL DAN PEMBAHASAN Kuat Tarik Baja kuat tarik baja tulangan dimaksudkan untuk mengetahui mutu atau spesifikasi dari baja tulangan dan baja sengkang yang digunakan dan terpasang pada benda uji berupa batang elemen strktur beton. Pada pengujian tarik baja ini, baja yang diigunankan adalah baja polos dengan diameter 8 mm dan diameter 6mm. Diameter Luas Penampang (mm2) Upper Lower Strenght Rata- Rata 1 6 28,26 229,272 227,214 228,494 2 6 28,26 233,965 229,161 231,563 Rata -tata 230,03 Tabel 1. Kuat Tarik Baja Diameter 6 mm Diameter 1 8 2 8 Luas Penampang (mm2) Upper Lower Strenght Rata- Rata Rata -tata 314,54 Hasil Kuat Tekan Rencana Beton kuat tekan beton dimaksudkan untuk mengetahui mutu dari beton yang akan digunakan sebagai benda uji. Pada pengujian kuat beton ini digunakan 5 buah beton lingkaran (silinder) dengan diameter 15 cm dan tinggi 30 cm yang telah mendapatkan pelakuan yang sama dengan cara direndam dalam bak perendam beton selama 28 hari. Benda Uji Tgl Pembuatan Tgl Uji Umur (hari) Berat (kg) Kuat Tekan (kn) 3 fc (MPa) 1 20/05/14 17/06/14 28 11,72 41935,8 24 2 21/05/14 18/06/14 28 13,2 51125 28,9 3 23/05/14 20/06/14 28 13 52415 29,7 4 26/05/14 22/06/14 28 13 52625 29,8 5 27/05/14 23/06/14 28 13 60118 34,02 Rata-rata 29,28 Tabel 4. Hasil Uji kuat tekan rencana beton Dari hasil pengujian kuat rencana beton, didapat rata-rata kuat rencana beton adalah sebesar 29,28 Mpa, sehingga dalam perhitungan secara analitis akan digunakan mutu beton (fc ) sebesar 29,28 Mpa. Hasil Analitis Kapasitas Momen Beton secara analitis pada penelitian ini dimaksudkan 50,24 314,243 310,905 312,574 untuk mengetahui kapasitas lentur pada beton. Dengan mengetahui kapasitas lentur beton makadapat dikondisikan 50,24 318,754 314,294 316,524 terjadinya gagal lentur pada beton. Benda Uji Mn ( kg.cm ) 1 Masif 64674,2 Tabel 2. Hasil uji tarik baja diameter 8 mm Dari pengujian kuat tarik baja didapatkan kuat tarik baja 6 mm adalah 230,029 Mpa dan baja diameter 8 mm adalah 314,549 Mpa. Hasil Uji Kuat Tarik Pipa PVC Pengujuan kuat tarik pipa dimaksudkan untuk mengetahui mutu dari pipa yang akan digunakan. Pada pengujian ini digunakan 2 potong pipa dengan diameter yang sama serta menggunakan pipa yang sama merk dan pabrikasinya. Pada pengujian ini pipa berukuran tinggi 50 cm. Tebal Luas Penampang (mm²) Upper (MPa) 1 2 7,138 8,079 2 2 7,138 5,456 Rata-rata 6,767 Tabel 3. Hasil uji kuat tarik pipa PVC Dari hasil pengujian kuat tarik pipa, didapatkan kuat tarik pipa PVC adalah 6,767 MPa. 2 Masif 64674,2 3 berlubang 2,36% ( pipa 3/4" ) 55947,42 4 berlubang 2,36% diisi cor 64674,2 5 berlubang 3,57% ( pipa 1" ) 53933,54 6 berlubang 3,57% diisi cor 64674,2 7 berlubang 6,15% ( pipa 1 1/4" ) 50577,08 8 berlubang 6,15% diisi cor 64674,2 9 berlubang 8,04% ( pipa 3/4" ) 48563,21 10 berlubang 8,04% diisi cor 64674,2 Tabel 4.6 Hasil Analitis Kapasitas Momen Beton Hasil Kuat Lentur Beton

4 Rojul Gayuh kuat Leksono lentur beton et al., Analisis dilakukan dan guna untuk Batang Dari Elemen hasil Struktur pengujian Beton kuat Bertulang beton dalam Berlubang menerima beban mengethaui kapasitas dan kuat tekan beton terhadap beban lentur, maka didapatkan beberapa pola retakan yang terjadi lentur. Berdasarkan hasil pengujian lab yang dilakuakan telah pada beton. Pola retakan yang terjadi merupakan pola retak didapatkan beberapa data untuk kapasitas dan kuat lentur gagal lentur yang terjadi pada beton. Pola retak gagal beton. lentur pada beton memiliki ciri yaitu retakan yang terjadi adalah retakan yang arah retaknya tegak lurus. Benda Uji Mn ( kg.cm ) 1 Masif 2 Masif 3 berlubang 2,36% ( pipa 3/4" ) 4 berlubang 2,36% diisi cor 5 berlubang 3,57% ( pipa 1" ) 6 berlubang 3,57% diisi cor 7 berlubang 6,15% ( pipa 1 1/4" ) 8 berlubang 6,15% diisi cor 9 berlubang 8,04% ( pipa 3/4" ) 10 berlubang 8,04% diisi cor Tabel 4.7 Hasil uji kuat lentur beton 57750 66000 56375 71500 53625 63250 50875 Dari hasil diatas dapat dilihat bahwa kekuatan lentur pada beton akan menurun seiring bertambah besarnya lubang yang ada pada beton, namun kekuatan beton relative sama pada beton deng pipa yang dicor, hal ini mungkin disebabkan karena pengaruh kekuatan pipa yang terlalu kecil. Perbandingan Momen Benton Massive dan Berlubang Data ini dugunakan untuk mengetahui pengaruh besarnya lubang pada beton. Pengaruh yang dimaksud adalah apakah besarnya reduksi kapasitas momen yang terjadi pada pipa berlubang. Tabel 4.7 Pengaruh diameter lubang pada beton Dari tabel diatas dapat dilihat bahwa reduksi kekuatan yang terjadi pada beton bertulang cukup siknifikan. Pada data analitis momen yang paling besar persentasenya adalah 100% dan yang terkecil adalah 75%, sedangkan pada hasil pengujian persentase persentase terbesar adalah 100% dan yang terkecil adalah 82%.. Pola Retak Pada Beton KESIMPULAN Berdasarkan hasil di atas yang diperoleh dari pengujian laboratorium, maka dapat diambil kesimpulan :

Rojul Gayuh Leksono et al., Analisis dan Batang Elemen Struktur Beton Bertulang Berlubang 1. Dari hasil pengujian diatas, beton 1 sampai 10 mengalami kegagalan lentur. 2. Adanya lubang pada beton mempengaruhi kuat lentur pada beton. Dapat dilihat dari tabel pada pembahasan di mana penurunan kekuatan lentur beton paling besar adalah 18% dan reduksi terkecil adalah 7% dari kapasitas beton tanpa lubang. 3. Dari hasil pengujian pola retakan yang terjadi pada semua benda uji adalah pola retak lentur. Hal ini sesuai dengan sesuai dengan perencanaan gagal lentur dan retak yang terjadi arah rambatnya hampir tegak lurus sumbu memanjang penampang. 5 Ucapan Terima Kasih Penulis mengucapkan terima kasih kepada semua pihak yang telah membantu dalam penyelesaian penelitian ini. DAFTAR PUSTAKA [1]. SNI 03 2847 2002. 2002. Tata Cara Perhitungan Struktur Beton Untuk Bangunan Gedung. Bandung.