STUDI EKSPERIMENTAL SAMBUNGAN LENTUR PADA BALOK RUMAH MODULAR ABSTRAK

dokumen-dokumen yang mirip
STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM PERSEGI BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP ABSTRAK

PERENCANAAN STRUKTUR RANGKA BAJA BRESING TAHAN GEMPA

ANALISIS LENTUR DAN GESER BALOK PRACETAK DENGAN TULANGAN SENGKANG KHUSUS ABSTRAK

PERENCANAAN GEDUNG BETON BERTULANG BERATURAN BERDASARKAN SNI DAN FEMA 450

STUDI EKSPERIMENTAL PERBAIKAN KOLOM LINGKARAN BETON BERTULANG ABSTRAK

PERENCANAAN STRUKTUR RANGKA BAJA BERATURAN TAHAN GEMPA BERDASARKAN SNI DAN FEMA 450

PERANCANGAN STRUKTUR ATAS GEDUNG CONDOTEL MATARAM CITY YOGYAKARTA. Oleh : KEVIN IMMANUEL KUSUMA NPM. :

PERILAKU KERUNTUHAN BALOK BETON BERTULANG TULANGAN GANDA ABSTRAK

PEMODELAN NUMERIK METODE ELEMEN HINGGA NONLINIER STRUKTUR BALOK TINGGI BETON BERTULANG ABSTRAK

BAB 4 PENGOLAHAN DATA DAN ANALISA

TINJAUAN KEKUATAN DAN ANALISIS TEORITIS MODEL SAMBUNGAN UNTUK MOMEN DAN GESER PADA BALOK BETON BERTULANG TESIS

PERANCANGAN STRUKTUR ATAS GEDUNG TRANS NATIONAL CRIME CENTER MABES POLRI JAKARTA. Oleh : LEONARDO TRI PUTRA SIRAIT NPM.

STUDI EKSPERIMENTAL PENGGUNAAN FRP (FIBER REINFORCED POLYMER)TERHADAP PERKUATAN KOLOM BETON BERTULANG ABSTRAK

STUDI EKSPERIMENTAL VARIASI TULANGAN SENGKANG PADA KOLOM PERSEGI ABSTRAK

ANALISIS METODE ELEMEN HINGGA DAN EKSPERIMENTAL PERHITUNGAN KURVA BEBAN-LENDUTAN BALOK BAJA ABSTRAK

STUDI DESAIN STRUKTUR BETON BERTULANG TAHAN GEMPA UNTUK BENTANG PANJANG DENGAN PROGRAM KOMPUTER

DAFTAR ISI JUDUL PENGESAHAN PERNYATAAN BEBAS PLAGIASI ABSTRAK ABSTRACT KATA PENGANTAR

PERENCANAAN STRUKTUR GEDUNG RUSUNAWA UNIMUS

d b = Diameter nominal batang tulangan, kawat atau strand prategang D = Beban mati atau momen dan gaya dalam yang berhubungan dengan beban mati e = Ek

ANALISIS DAN DESAIN STRUKTUR TAHAN GEMPA DENGAN SISTEM BALOK ANAK DAN BALOK INDUK MENGGUNAKAN PELAT SEARAH

Henny Uliani NRP : Pembimbing Utama : Daud R. Wiyono, Ir., M.Sc Pembimbing Pendamping : Noek Sulandari, Ir., M.Sc

UJI EKSPERIMENTAL KEKUATAN DRAINASE TIPE U-DITCH PRACETAK

DESAIN TAHAN GEMPA BETON BERTULANG PENAHAN MOMEN MENENGAH BERDASARKAN SNI BETON DAN SNI GEMPA

STUDI EKSPERIMENTAL PENGARUH PENGGUNAAN PS BALL SEBAGAI PENGGANTI PASIR TERHADAP KUAT LENTUR BETON

ANALISIS LENDUTAN SEKETIKA DAN JANGKA PANJANG PADA STRUKTUR PELAT DUA ARAH. Trinov Aryanto NRP : Pembimbing : Daud Rahmat Wiyono, Ir., M.Sc.

BAB III LANDASAN TEORI

Kata Kunci : beton, baja tulangan, panjang lewatan, Sikadur -31 CF Normal

2.5.3 Dasar Teori Perhitungan Tulangan Torsi Balok... II Perhitungan Panjang Penyaluran... II Analisis dan Desain Kolom...

PERHITUNGAN DAN PENGGAMBARAN DIAGRAM INTERAKSI KOLOM BETON BERTULANG DENGAN PENAMPANG PERSEGI. Oleh : Ratna Eviantika. : Winarni Hadipratomo, Ir.

BAB I PENDAHULUAN. Universitas Kristen Maranatha 1

BAB III LANDASAN TEORI

STUDI ANALISIS PERTEMUAN BALOK KOLOM BERBENTUK T STRUKTUR RANGKA BETON BERTULANG DENGAN PEMODELAN STRUT-AND- TIE ABSTRAK

ANALISIS DAKTILITAS BALOK BETON BERTULANG

STUDI KUAT LENTUR BALOK DENGAN PENAMBAHAN GLENIUM ACE 8590

BAB III LANDASAN TEORI

PENGUJIAN LENTUR BALOK BETON BERTULANG DENGAN MENGGUNAKAN MODIFIKASI ALAT UJI TEKAN

PENGUJIAN KUAT LENTUR PANEL PELAT BETON RINGAN PRACETAK BERONGGA DENGAN PENAMBAHAN SILICA FUME

STUDI EKSPERIMENTAL PENGUJIAN BEBAN SIKLIK KOLOM LINGKARAN BETON BERTULANG DENGAN PERKUATAN PEN-BINDER DAN FRP ABSTRAK

EVALUASI SENDI PLASTIS DENGAN ANALISIS PUSHOVER PADA GEDUNG TIDAK BERATURAN

STUDI PERILAKU MEKANIK KEKUATAN BETON RINGAN TERHADAP KUAT LENTUR BALOK

DAFTAR ISI KATA PENGANTAR DAFTAR TABEL DAFTAR GAMBAR DAFTAR LAMPIRAN DAFTAR NOTASI DAN SIMBOL

3.4.5 Beban Geser Dasar Nominal Statik Ekuivalen (V) Beban Geser Dasar Akibat Gempa Sepanjang Tinggi Gedung (F i )

BAB II TINJAUAN PUSTAKA

PERENCANAAN JEMBATAN KALI TUNTANG DESA PILANGWETAN KABUPATEN GROBOGAN

STUDI EKSPERIMENTAL PERBAIKAN KOLOM PERSEGI BETON BERTULANG ABSTRAK

1.6 Tujuan Penulisan Tugas Akhir 4

PERANCANGAN ULANG STRUKTUR GEDUNG BANK MODERN SOLO

DAFTAR NOTASI BAB I β adalah faktor yang didefinisikan dalam SNI ps f c adalah kuat tekan beton yang diisyaratkan f y

IV. HASIL DAN PEMBAHASAN. Pembahasan hasil penelitian ini secara umum dibagi menjadi lima bagian yaitu

ANALISIS KOLOM BAJA WF MENURUT TATA CARA PERENCANAAN STRUKTUR BAJA UNTUK BANGUNAN GEDUNG ( SNI ) MENGGUNAKAN MICROSOFT EXCEL 2002

PERANCANGAN STRUKTUR HOTEL DI JALAN LINGKAR UTARA YOGYAKARTA

BAB II TINJAUAN PUSTAKA. gedung dalam menahan beban-beban yang bekerja pada struktur tersebut. Dalam. harus diperhitungkan adalah sebagai berikut :

Analisis Pertemuan Balok-Kolom Struktur Rangka Beton Bertulang Menggunakan Metode Strut And Tie. Nama: Budi Piyung Riyadi NRP :

KAJIAN PERILAKU LENTUR PELAT KERAMIK BETON (KERATON) (064M)

Kinerja Hubungan Pelat-Kolom Struktur Flat Plate Bertulangan Geser Stud Rail dan Sengkang Dalam Menahan Beban Lateral Siklis

TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG PERPUSTAKAAN PUSAT YSKI SEMARANG

PERANCANGAN STRUKTUR ATAS STUDENT PARK APARTMENT SETURAN YOGYAKARTA

Seminar Nasional VII 2011 Teknik Sipil ITS Surabaya Penanganan Kegagalan Pembangunan dan Pemeliharaan Infrastruktur

STUDI PERBANDINGAN ANALISIS PELAT KONVENSIONAL DAN PELAT PRACETAK ABSTRAK

PENGARUH PENEMPATAN PENYAMBUNGAN PADA PERILAKU RANGKAIAN BALOK-KOLOM BETON PRACETAK BAGIAN SISI LUAR

Pengujian Tahan Gempa Sistem Struktur Beton Pracetak

DAFTAR ISI. Halaman Judul Pengesahan Persetujuan Surat Pernyataan Kata Pengantar DAFTAR TABEL DAFTAR GAMBAR DAFTAR NOTASI DAFTAR LAMPIRAN

PERANCANGAN STRUKTUR BANGUNAN RUMAH SUSUN DI SURAKARTA

DESAIN BALOK SILANG STRUKTUR GEDUNG BAJA BERTINGKAT ENAM

DAFTAR ISI HALAMANJUDUL HALAMAN PENGESAHAN KATAPENGANTAR DAFTAR TABEL DAFTAR GAMBAR DAFTAR LAMPIRAN DAFTAR NOTASI FAKTOR KONVERSI

BAB III LANDASAN TEORI

ANALISIS LENDUTAN SEKETIKA dan LENDUTAN JANGKA PANJANG PADA STRUKTUR BALOK. William Trisina NRP : Pembimbing : Daud Rahmat Wiyono, Ir.,M.Sc.

PERILAKU BALOK BERTULANG YANG DIBERI PERKUATAN GESER MENGGUNAKAN LEMBARAN WOVEN CARBON FIBER

ANALISIS DINAMIK RAGAM SPEKTRUM RESPONS GEDUNG TIDAK BERATURAN DENGAN MENGGUNAKAN SNI DAN ASCE 7-05

STUDI PERILAKU SAMBUNGAN BALOK PRACETAK UNTUK RUMAH SEDERHANA TAHAN GEMPA AKIBAT BEBAN STATIK

PENGARUH PENINGKATAN KAPASITAS AIR TERHADAP KEKUATAN STRUKTUR BAK SEDIMENTASI PADA INSTALASI PENGOLAHAN AIR

STUDI EKSPERIMENTAL PENGGUNAAN PORTLAND COMPOSITE CEMENT TERHADAP KUAT LENTUR BETON DENGAN f c = 40 MPa PADA BENDA UJI BALOK 600 X 150 X 150 mm 3

STUDI EKSPERIMENTAL KUAT LENTUR PADA BALOK BETON BERTULANG DENGAN PERKUATAN BAJA RINGAN PROFIL U

1.2 Tujuan Penelitian 2

DAFTAR ISI. HALAMAN JUDUL... i. HALAMAN PENGESAHAN...ii. HALAMAN PERNYATAAN... iii. KATA PENGANTAR... iv. HALAMAN PERSEMBAHAN... vi. DAFTAR ISI...

BAB III LANDASAN TEORI. A. Pembebanan Pada Pelat Lantai

Kata kunci: Balok, bentang panjang, beton bertulang, baja berlubang, komposit, kombinasi, alternatif, efektif

STUDI KAPASITAS PENAMPANG EKIVALEN KOLOM PERSEGI TERHADAP PENAMPANG KOLOM L, T DAN + PADA BANGUNAN RUMAH TINGGAL DENGAN BEBAN GEMPA

STUDI PERBANDINGAN STRUKTUR RANGKA ATAP BAJA UNTK BERBAGAI TYPE TUGAS AKHIR M. FAUZAN AZIMA LUBIS

Latar Belakang : Banyak bencana alam yang terjadi,menyebabkan banyak rumah penduduk rusak

TUGAS AKHIR PERENCANAAN STRUKTUR GEDUNG KANTOR PERPAJAKAN PUSAT KOTA SEMARANG

Oleh : MUHAMMAD AMITABH PATTISIA ( )

KERUNTUHAN LENTUR BALOK PADA STRUKTUR JOINT BALOK-KOLOM BETON BERTULANG EKSTERIOR AKIBAT BEBAN SIKLIK

8. Sahabat-sahabat saya dan semua pihak yang tidak dapat disebutkan satupersatu yang telah membantu dalam menyelesaikan dan menyusun Tugas Akhir ini.

PERENCANAAN STRUKTUR GEDUNG BANK MANDIRI JL. NGESREP TIMUR V / 98 SEMARANG

PERANCANGAN ULANG STRUKTUR ATAS GEDUNG PERKULIAHAN FMIPA UNIVERSITAS GADJAH MADA

ANALISIS KOLOM BETON BERTULANG DENGAN CORBEL TUNGGAL MENGGUNAKAN PEMODELAN PENUNJANG DAN PENGIKAT. Nama : Jefry Christian Assikin NRP :

PERANCANGAN STRUKTUR ATAS GEDUNG APARTEMEN SEMBILAN LANTAI DI YOGYAKARTA. Oleh : PRISKA HITA ERTIANA NPM. :

STUDI EKSPERIMENTAL KUAT LENTUR PADA BALOK BETON BERTULANG DENGAN PERKUATAN BAJA RINGAN PROFIL U TUGAS AKHIR. Disusun oleh : LOLIANDY

PERBANDINGAN STRUKTUR BETON BERTULANG DENGAN STRUKTUR BAJA DARI ELEMEN BALOK KOLOM DITINJAU DARI SEGI BIAYA PADA BANGUNAN RUMAH TOKO 3 LANTAI

KINERJA STRUKTUR RANGKA BETON BERTULANG DENGAN PERKUATAN BREISING BAJA TIPE X

KEKUATAN SAMBUNGAN BALOK BETON BERTULANG DENGAN SIKADUR -31 CF NORMAL

BAB III LANDASAN TEORI. dibebani gaya tekan tertentu oleh mesin tekan.

BAB II TINJAUAN PUSTAKA

ANALISIS PERILAKU STRUKTUR RANGKA BAJA DENGAN DAN TANPA BRESING V-TERBALIK EKSENTRIK

BAB II TINJAUAN PUSTAKA. pembebanan yang berlaku untuk mendapatkan suatu struktur bangunan

TUGAS AKHIR PERENCANAAN STRUKTUR KONSTRUKSI BAJA GEDUNG DENGAN PERBESARAN KOLOM

PERANCANGAN STRUKTUR BANGUNAN RUMAH SUSUN DI YOGYAKARTA

BAB II TINJAUAN PUSTAKA

DAFTAR ISI. 1.1 Latar Belakang Perumusan Masalah Tujuan Batasan Masalah Manfaat... 4 BAB II TINJAUAN PUSTAKA...

Transkripsi:

STUDI EKSPERIMENTAL SAMBUNGAN LENTUR PADA BALOK RUMAH MODULAR Alexander Revaldy 1421022 Pembimbing: Dr. Anang Kristianto, S.T., M.T. ABSTRAK Indonesia sebagai negara berkembang terus membangun dalam berbagai infrastruktur. Salah satu infrastruktur penting tersebut yaitu perumahan, mengingat Indonesia memiliki jumlah penduduk yang sangat besar dan masih memerlukan perumahan sebagai kebutuhan dasar masyarakatnya. Berdasarkan fakta ini maka diperlukan pengembangan ilmu Teknik Sipil yang terkait dengan bagaimana menerapkan rumah yang layak untuk dihuni namun cukup ekonomis dalam pembuatannya. Oleh karena itu Kementerian Pekerjaan Umum dan Perumahan Rakyat secara khusus melalui Badan Penelitian dan Pengembangan Pekerjaan Umum dan Perumahan Rakyat telah mengembangkan dan menerapkan Rumah Instan Sederhana (RISHA). RISHA dibuat dengan menggunakan sistem frame yang terdiri atas balok dan kolom dengan dilengkapi boks dan pelat penyambung khusus. Penelitian ini bertujuan untuk menganalisis kapasitas kuat lentur dan deformasi pada sambungan balok. Benda uji terdiri atas 2 buah elemen balok yang berdimensi 120mmx120mm dengan panjang masing-masing 1m dan mutu betonnya f'c = 15MPa dan disambung dengan 3 jenis sambungan, yaitu: sambungan tipe A dengan penampang persegi, sambungan tipe B dengan penampang berbentuk huruf I, dan sambungan tipe C dengan penampang berbentuk plus. Setiap jenis balok dibuat 2 buah benda uji yang sama untuk dilakukan 2 macam sambungan, yaitu: sambungan kering (dry connection) dan sambungan basah (wet connection) untuk masingmasing tipe sambungan. Pengujian dilakukan dengan uji lentur third point loading hingga balok mengalami kegagalan. Hasil dari penelitian ini menunjukkan bahwa kapasitas kuat lentur terbesar untuk sambungan dry connection yaitu sambungan tipe A sebesar 17,24kN sedangkan untuk sambungan wet connection yaitu sambungan tipe B sebesar 19,93kN. Untuk hasil deformasi menunjukan bahwa deformasi terkecil untuk dry connection dan wet connection yaitu sambungan tipe B sebesar 36mm dan 17 mm sedangkan sambungan tipe B memiliki daktilitas terbesar untuk dry connection sebesar 5,23 dan sambungan tipe C memiliki daktilitas terbesar untuk wet connection sebesar 4,71. Perbandingan hasil perubahan dari dry connection ke wet connection untuk kapasitas kuat lentur terbesar yaitu sambungan tipe B sebesar 4,03kN dan deformasi terbesar yaitu sambungan tipe A sebesar 25mm. Kata kunci: rumah modular, modular balok, perkuatan, daktilitas ix

STUDY EXPERIMENTAL BENDING CONNECTION ON BEAM FARBRICATED HOUSE Alexander Revaldy 1421022 Supervisor: Dr. Anang Kristianto, S.T., M.T. ABSTRACT Indonesia as a developing country constantly build a variety of infrastructure. One of the important infrastructure is residential, considering Indonesia have large population and still need residential as basic needs community. Based on this fact requires development of relevant civil engineering science with how to apply a decent house to be inhabited but still quite economical for manufacture. Therefore Ministry of Public Works and Housing specifically through Public Works and Housing Research and Development Agency has developed and implemented Rumah Instan Sederhana (RISHA). RISHA made with frame structure system consist of beam and column with boxes and specific plate connector. This study aims to analyze the capacity of strong bending and deformation at beam joints. The test object contain 2 pieces of beam elements with dimension 120mmx120mm, length 1m and quality of concrete is f'c = 15MPa which is connected form 3 types connection types that is connection type A with square sectional, connection type B with sectional I shaped, and connection type C with sectional cross section. Every type of a beam made 2 pieces test of object to be done 2 kinds of connection that is dry connection and wet connection for each type of connections. Testing is done by using third point loading until beam failure. The result of this study indicate the largest bending capacity for dry connection is connection type A with 17,24kN while for wet connection is connection type B with 19,93kN. For the result of deformation indicate that low deformation for dry connection and wet connection is connection type B with 36mm and 17mm while connection type B have highest ductility for dry connection with 5,23 and connection type C have highest ductility for wet connection with 4,71. The comparison of the result of change form dry connection to wet connection for the largest bending is connection type B with 4,03kN and the largest deformation is connection type A with 25mm Keywords: fabricated house, modular beam, ductility x

DAFTAR ISI HALAMAN JUDUL... i LEMBAR PENGESAHAN... ii PERNYATAAN ORISINALITAS LAPORAN PENELITIAN... iii PERNYATAAN PUBLIKASI LAPORAN PENELITIAN... iv SURAT KETERANGAN TUGAS AKHIR... v SURAT KETERANGAN SELESAI TUGAS AKHIR... vi KATA PENGANTAR... vii ABSTRAK... ix ABSTRACT... x DAFTAR ISI... xi DAFTAR GAMBAR... xiii DAFTAR TABEL... xv DAFTAR NOTASI... xvi DAFTAR LAMPIRAN... xvii BAB I PENDAHULUAN... 1 1.1 Latar Belakang... 1 1.2 Tujuan Penelitian... 2 1.3 Ruang Lingkup Penelitian... 2 1.4 Sistematika Penulisan... 2 BAB II STUDI LITERATUR... 4 2.1 Rumah... 4 2.1.1 Rumah Tinggal... 4 2.1.2 Rumah Modular... 4 2.2 Beton Bertulang... 5 2.3 Material Pembentuk Beton... 6 2.3.1 Semen Portland... 6 2.3.2 Air... 6 2.3.3 Agregat... 7 2.4 Balok Lentur... 9 2.5 Sambungan Beton Bertulang... 12 2.5.1 Dry Connection dan Wet Connection... 12 2.5.2 Sambungan Las dan Baut... 14 2.5.3 Kuat Geser Baut, Kuat Tumpu, dan Cek Geser Blok... 16 2.5.4 Kuat Leleh Baja Pada Sambungan... 17 2.5.5 Pengaruh Lendutan pada Sambungan... 17 2.6 Nilai Daktilitas... 19 2.6.1 Nilai Daktilitas untuk Offset pada Jarak 0... 20 2.6.2 Nilai Daktilitas untuk Offset pada Jarak 0,2%... 20 2.7 Konsep Perancangan... 21 2.8 Pengujian Laboratorium... 22 BAB III METODE PENELITIAN... 24 3.1 Diagram Alir Penelitian... 24 3.2 Preliminary Design Sambungan Balok... 26 3.3 Preliminary Design Bangunan Rumah Modular... 27 xi

3.4 Analisis Balok Beton Bertulang... 29 3.5 Pengecekan Kapasitas Sambungan Balok... 31 3.6 Preliminary Lendutan pada Balok... 38 3.7 Pelaksanaan Pembuatan Benda Uji... 39 3.7.1 Perencanaan Campuran Beton... 39 3.7.2 Pembuatan Benda Uji... 41 3.7.3 Perawatan Benda Uji... 43 3.8 Pengujian Kuat Tekan Silinder Beton... 44 3.9 Perencanaan Campuran Grouting untuk Wet Connection... 45 3.10 Persiapan Pengujian... 47 3.11 Proses Pengujian Benda Uji... 49 BAB IV ANALISIS DATA... 50 4.1 Hasil Analisis... 50 4.2 Pola Retak Sambungan Balok dengan Dry Connection... 50 4.2.1 Pola Retak Sambungan Balok Tipe A... 50 4.2.2 Pola Retak Sambungan Balok Tipe B... 51 4.2.3 Pola Retak Sambungan Balok Tipe C... 53 4.3 Pola Retak Sambungan Balok dengan Wet Connection... 54 4.3.1 Pola Retak Sambungan Balok Tipe A... 54 4.3.2 Pola Retak Sambungan Balok Tipe B... 56 4.3.3 Pola Retak Sambungan Balok Tipe C... 57 4.4 Kapasitas Beban dan Deformasi Balok dengan Dry Connection dan Wet Connection... 58 4.4.1 Sambungan Balok Tipe A... 58 4.4.2 Sambungan Balok Tipe B... 61 4.4.3 Sambungan Balok Tipe C... 64 4.5 Perbandingan Hasil Kapasitas, Deformasi, dan Daktilitas Sambungan Balok Lentur... 66 BAB V KESIMPULAN DAN SARAN... 70 5.1 Kesimpulan... 70 5.2 Saran... 71 DAFTAR PUSTAKA... 72 LAMPIRAN... 73 xii

DAFTAR GAMBAR Gambar 1.1 Rumah Modular RISHA dari Kementrian PUPR... 1 Gambar 2.1 Tipikal Sambungan Pracetak... 13 Gambar 2.2 Tipikal Sambungan pada Modul dengan Menggunakan Baut dan Las... 14 Gambar 2.3 Model Sambungan Kolom pada Struktur Design for Disassembly (DfD)... 15 Gambar 2.4 Model Sambungan Kering pada Balok dengan Menggunakan Baut... 15 Gambar 2.5 Defleksi Balok dengan Beban Merata Sepanjang Bentang... 17 Gambar 2.6 Balok dengan 2 Beban Terpusat... 18 Gambar 2.7 Perilaku Beban-Lendutan pada Elemen Lentur... 19 Gambar 2.8 Batas Leleh dan Batas Putus pada Elemen Lentur... 20 Gambar 2.9 Batas 0 dan 0,2% Offset Yield Stress pada Elemen Lentur... 20 Gambar 2.10 Variasi ϕ dengan Regangan Tarik Netto Dalam Baja Tarik Terluar, εt, dan c/dt untuk Tulangan mutu 420 dan untuk Baja Prategang... 22 Gambar 2.9 Skema Pembebanan Menggunakan Third Point Loading... 23 Gambar 3.1 Diagram Alir Penelitian... 25 Gambar 3.2 Sambungan Balok Tipe A... 26 Gambar 3.3 Sambungan Balok Tipe B... 26 Gambar 3.4 Sambungan Balok Tipe C... 27 Gambar 3.5 Pemodelan Boks... 227 Gambar 3.6 Detail Komponen Balok... 28 Gambar 3.7 Pemyambungan Balok dan Boks Joint... 29 Gambar 3.8 Gaya-gaya pada Benda Uji... 29 Gambar 3.9 Potongan diagram momen untuk sumbu x=500mm... 2230 Gambar 3.10 Sambungan Boks dengan Balok Menggunakan Baut... 32 Gambar 3.11 Evaluasi Kuat Tumpu... 33 Gambar 3.12 Evaluasi Kuat Blok Geser... 35 Gambar 3.13 Diagram Momen dan Gaya Geser... 36 Gambar 3.14 (a) Semen Portland (b) Pasir Beton (c) Kerikil... 40 Gambar 3.15 Pengujian Slump... 40 Gambar 3.16 Hasil Pembuatan Boks... 41 Gambar 3.17 Besi Tulangan dan Strain Gauge yang Sudah Terpasang... 42 Gambar 3.18 Besi Tulangan Dimasukkan ke Dalam Bekisting... 2242 Gambar 3.19 Campuran Beton Dimasukkan ke Dalam Bekisting... 43 Gambar 3.20 Hasil Benda Uji Setelah 28 Hari... 43 Gambar 3.21 Pengujian Kuat Tekan Silinder Beton... 44 Gambar 3.22 Kuat Tekan Silinder Beton yang Sudah Diuji... 44 Gambar 3.23 Proses Pemasangan Bekisting pada Wet Connection... 45 Gambar 3.24 (a) Sika Grout Sebelum Diberi Air (b) Sika Grout yang Sudah Menjadi Pasta... 45 Gambar 3.25 Proses Pemasukan Campuran Grouting pada Bekisting... 46 Gambar 3.26 Campuran Grouting yang Sudah Dilepas dari Bekisting... 46 Gambar 3.27 Benda Uji Setelah 28 Hari dan Siap Diuji... 2247 xiii

Gambar 3.28 LVDT yang Digunakan... 47 Gambar 3.29 UTM dan Tumpuan yang Digunakan... 48 Gambar 3.30 Set-Up Alat Pengujian... 48 Gambar 3.31 Set-Up Alat Pengujian di Laboratorium... 49 Gambar 4.1 (a) Pola Retak Balok Tipe A (b) Kondisi Boks Tipe A... 50 Gambar 4.2 Pemodelan Balok Tipe A Dry Connection... 51 Gambar 4.3 (a) Pola Retak Balok Tipe B (b) Pola Retak Maksimum Balok Tipe B... 52 Gambar 4.4 Pemodelan Balok Tipe B Dry Connection... 53 Gambar 4.5 (a) Pola Retak Balok Tipe C (b) Lendutan yang Terjadi Pada Boks... 53 Gambar 4.6 Pemodelan Balok Tipe C Dry Connection... 54 Gambar 4.7 (a) Pola Retak Balok Tipe A (b) Kondisi Boks Tipe A... 2255 Gambar 4.8 Pemodelan Balok Tipe A Wet Connection... 55 Gambar 4.9 (a) Pola Retak Balok Tipe B (b) Kondisi Boks Tipe B... 56 Gambar 4.10 Pemodelan Balok Tipe B Wet Connection... 57 Gambar 4.11 (a) Pola Retak Balok Tipe C (b) Kondisi Boks Tipe C... 57 Gambar 4.12 Pemodelan Balok Tipe C Wet Connection... 58 Gambar 4.13 Kurva Beban dengan Deformasi Sambungan Balok Tipe A Dry Connection... 60 Gambar 4.14 Kurva Beban dengan Deformasi Sambungan Balok Tipe A Wet Connection... 61 Gambar 4.15 Kurva Sambungan Balok Tipe A... 61 Gambar 4.16 Kurva Beban dengan Deformasi Sambungan Balok Tipe B Dry Connection... 63 Gambar 4.17 Kurva Beban dengan Deformasi Sambungan Balok Tipe B Wet Connection... 64 Gambar 4.18 Kurva Sambungan Balok Tipe B... 64 Gambar 4.19 Kurva Beban dengan Deformasi Sambungan Balok Tipe C Wet Connection... 66 Gambar 4.20 Kurva Hasil Sambungan Balok Dry Connection... 68 Gambar 4.21 Kurva Hasil Sambungan Balok Wet Connection... 68 xiv

DAFTAR TABEL Tabel 3.1 Nilai Slump Berdasarkan ACI-211.1... 43 Tabel 3.2 Hasil Uji Kuat Silinder... 47 Tabel 4.1 Hasil Pengujian Sambungan Balok Tipe A pada Offset 0... 60 Tabel 4.2 Hasil Pengujian Sambungan Balok Tipe A pada Offset 0,2%... 60 Tabel 4.3 Hasil Pengujian Sambungan Balok Tipe B Offset 0... 63 Tabel 4.4 Hasil Pengujian Sambungan Balok Tipe B Offset 0,2%... 63 Tabel 4.5 Hasil Pengujian Sambungan Balok Tipe C Offset 0... 65 Tabel 4.6 Hasil Pengujian Sambungan Balok Tipe C Offset 0,2%... 65 Tabel 4.7 Hasil Pengujian Sambungan Sambungan Balok... 66 Tabel 4.8 Hasil Pengujian Beban Sambungan Balok... 67 Tabel 4.9 Hasil Pengujian Deformation Sambungan Balok... 67 Tabel 4.10 Hasil Pengujian Nilai Daktilitas Sambungan Balok... 69 xv

DAFTAR NOTASI a Ab Agv Ant Anv bp Cd Cs Cvx d di d 1 f'c Fi Fnt Fnv Fpy Fu Fy l c g hi dan hx hsx h1 Mp Mu Px R Rn s t tp Ubs V Zx δ δxe σ σijin γ r Jarak tumpuan ke beban terpusat Luas baut Luas bruto penahan geser Luas netto penahan tarik Luas netto penahan geser Lebar pelat Faktor amplifikasi defleksi Koefisien respon seismik Faktor distribusi vertikal Diameter baut Jarak baris ke-i dari baut tarik terhadap titik berat Jarak titik pusat antar baut Mutu beton Gaya gempa lateral statik Tegangan tarik nominal Tegangan geser nominal Tegangan leleh dari material pelat ujung Kekuatan tarik minimum Tegangan leleh minimum Jarak bersih antara tepi lubang dan tepi lubang yang berdekatan Percepatan gravitasi Tinggi dari dasar sampai tingkat i atau x Tinggi tingkat di bawah tingkat x Jarak tinggi baut serat bawah sampai serat atas Momen lentur plastis Momen ultimit Beban desain vertikal pada dan di atas tingkat x Koefisien modifikasi respons Kekuatan nominal Spasi pusat-ke pusat longitudinal setiap dua lubang Tebal pelat Tebal pelat ujung Koefisien reduksi Gaya lateral desain total atau geser di dasar struktur Modulus penampang plastis Defleksi Defleksi pada lokasi yang disyaratkan Tegangan Tegangan izin Faktor peningkatan kapasitas sambungan untuk memenuhi syarat sebagai sambungan rigid Faktor ketahanan 1 Nilai daktilitas pada offset 0 2 Nilai daktilitas pada offset 0,2% xvi

DAFTAR LAMPIRAN Lampiran L.1 Detail Komponen 73 Lampiran L.2 Detail Pola Retak 76 xvii