ANALISIS PUSHOVER TERHADAP RESPON STRUKTUR DENGAN MENGGUNAKAN BASE ISOLATOR

Ukuran: px
Mulai penontonan dengan halaman:

Download "ANALISIS PUSHOVER TERHADAP RESPON STRUKTUR DENGAN MENGGUNAKAN BASE ISOLATOR"

Transkripsi

1 Jurnal Arsip Rekayasa Sipil dan Perencanaan (JARSP) Journal of Archive in Civil Engineering and Planning E-ISSN: Journal homepage: ANALISIS PUSHOVER TERHADAP RESPON STRUKTUR DENGAN MENGGUNAKAN BASE ISOLATOR Fitry Hasdanita a,*, Mochammad Afifuddin b, Muttaqin Muttaqin c a Magister Teknik Sipil, Fakultas Teknik, Universitas Syiah kuala, Banda Aceh b,c Jurusan Teknik Sipil, Fakultas Teknik, Universitas Syiah Kuala, Banda Aceh *Corresponding author, address: fitryhasdanita@gmail.com A R T I C L E I N F O A B S T R A C T Article History: Recieved 7 December 017 Recieved in revised from 01 March 018 Accepted 07 March 018 Keywords: Pushover Analysis, Base Isolator, Lead Rubber Bearing, Fixed Base, Base Isolated, Performance point The earthquake-resistant building is a concept in construction technology that is in line with technology evolution. The idea of this earthquake-resistant concept is to reduce the seismic force that might work to the building structure instead of strengthening the structure itself. The structural component for reducing the earthquake force is called as a base isolator or seismic isolation. During seismic loading, this component is expected to accept and minimize the earthquake forces at a certain level without any significant damage to structure. This research is conducted to evaluate the response of the structure with base isolator. Then, the influence of base isolator on building structure is justified. Two () different types of structures, fixed base and baseisolated structure with a variety of post-yield stiffness (K ), were developed. The used type of base isolator is Lead Rubber Bearing (LRB). The analysis is conducted in accordance with pushover analysis method using SAP000 v.19 program. The result suggested that the building structure with base isolator extends the natural period of the structure up to 1,380 times. The interstory drift of the base-isolated structure is smaller than the fixed base structure. The use of base isolator reduces the top displacement to an average of 1.93% for x- and % for y-direction. The overall structure performance evaluation of fixed base and base-isolated structures is at Damage Control level. 018 Magister Teknik Sipil Unsyiah.All rights reserved 1. PENDAHULUAN Seiring dengan perkembangan teknologi khususnya teknologi konstruksi, muncul konsep baru mengenai bangunan tahan gempa. Gagasan dari konsep ini ialah bangunan tahan gempa tidak didesain dengan memperkuat tahanan strukturnya terhadap gaya gempa, melainkan bagaimana cara mereduksi gaya gempa yang bekerja pada bangunan tersebut atau menambah suatu sistem struktur yang dikhususkan untuk menyerap sebagian energi gempa yang masuk kebangunan dan hanya sebagian kecil (sisanya) dipikul oleh komponen struktur bangunan tersebut. Sistem struktur yang mampu mereduksi gaya gempa ini dikenal dengan nama base isolator atau isolasi seismic (Erista D, 011). Tujuan dari penelitian ini mengevaluasi respon struktur akibat pengaruh penggunaan base isolator pada struktur gedung sebagai alternatif pereduksi beban gempa. Hasil penelitian ini dibandingkan dengan respon struktur fixed base. 169

2 . KAJIAN PUSTAKA.1 Perencanaan Berbasis Kenerja (Performance Based Design) Menurut dewobroto (005), bangunan pada daerah rawan gempa harus direncanakan mampu bertahan terhadap gempa. Trend perencanaan yang terkini adalah performance based seismic design, yang memanfaatkan teknik analisis nonlinear berbasis komputer untuk menganalisis perilaku inelastis struktur dari berbagai macam intensitas gerakan tanah (gempa). Sehingga dapat diketahui kinerja pada kondisi kritis. Selanjutnya dapat dilakukan tindakan bilamana tidak memenuhi persyaratan yang diperlukan. Mengacu pada FEMA (Federal Emergency Management Agency) 73 (1997) yang menjadi acuan klasik bagi perencanaan berbasis kinerja maka kategori level kinerja struktur, adalah IO (Immediate Occupancy), LS (Life-Safety), CP (Collapse Prevention). Tingkat kinerja struktur yang diatur dalam ATC 40 (Aplplied Technology Council-40) adalah seperti pada Tabel 1. Tabel 1 Tingkat Kinerja Struktur Menurut ATC 40 Immediate Interstory drift limit Occupancy Damage Control Life safety Structural Stability Maximum Total Drift V i /P i Maximum Inelastis Drift No Limit No Limit Sumber : ATC 40 Menurut Wisnumurti et al (008), analisis statik nonlinear pushover merupakan komponen performance based design yang menjadi sarana dalam mencari kapasitas dari suatu struktur. Dasar analisis dilakukan dengan peningkatan beban statik tertentu dalam arah lateral yang nilainya ditingkatkan berangsur-angsur (incremental) secara proporsional pada struktur hingga mencapai target displacement atau mencapai mekanisme diambang keruntuhan. Prosedur analisisnya akan menjelaskan bagaimana mengidentifikasikan bagian-bagian dari bangunan yang akan mengalami kegagalan terlebih dahulu. Performance point adalah titik dimana capacity sama dengan demand. Hasil dari analisis pushover adalah kurva kapsitas (capacity curve). Agar kurva kapasitas dan kurva kebutuhan ini dapat dibandingkan secara langsung, maka kurva kapasitas struktur harus digambarkan menjadi satu dengan kurva kebutuhan dengan format Acceleration (Sa) dan Displacement (Sd), dan Response Spectrum (ADRS). Setelah performance point diperoleh, dapat diketahui nilai simpangan antar tingkat dan sendi plastis untuk berbagai periode ulang gempa. Selain itu, dapat ditentukan tingkat kinerja struktur dari simpangan antar tingkat untuk berbagai periode ulang gempa. Proses pembentukan performance point dapat dilihat pada Gambar 1.. Base Isolation System Menurut Samsuryana (011), base isolation sistem adalah desain alternatif untuk mengurangi resiko kerusakan bangunan akibat gempa dengan cara mereduksi beban gempa yang bekerja pada bangunan. Base isolator mempunyai kekakuan geser yang relatif kecil akan meningkatkan daya tahan bangunan terhadap gempa. Bangunan memiliki waktu getar alami yang lebih panjang, sehingga percepatan gempa yang bekerja pada bangunan tersebut menjadi lebih kecil. Dengan demikian gaya gempa yang bekerja pada struktur atau bangunan tersebut menjadi berkurang atau tereduksi (Marsico, M.R, 008). Disamping itu, base isolator juga mempunyai kemampuan untuk kembali ke posisi semula saat terjadi gerakan seismik. Contoh struktur bangunan base isolator seperti pada Gambar

3 Gambar 1. Struktur dengan Base Isolator (Sumber: Akhare dan Wankhade, 014) Menurut Naeim, F dan Kelly, J.M (1999), LRB adalah salah satu jenis base isolator yang telah dikembangkan untuk memproteksi struktur dari bahaya gempa. LRB merupakan base isolator jenis elastomeris rubber bearing yang terdiri dari beberapa lapisan karet alam atau sintetik yang mempunyai nisbah redaman kritikal antara % 5%. Dalam analisis struktur, LRB dapat dimodelkan sebagai model bilinier dengan tiga (3) parameter yang menentukan karakteristik mekanisme dari LRB, yaitu: kekakuan awal (K 1 ), kekakuan pasca leleh (K ), dan kekakuan leleh dari inti timah (Q) seperti pada Gambar. K 1 memiliki nilai kekakuan yang cukup besar dan direncanakan untuk beban angin dan gempa kecil. Nilai K 1 sulit diukur dan biasanya diambil secara empiris dari kelipatan K. Pada umumnya nilai K 1 mencapai 6 s/d 10 kali kekakuan K. Nilai K dapat diperkirakan secara akurat dari modulus geser karet dan desain bearing. Gambar. Kurva bilinier hysteresis loop, parameter dasar yang menentukan mekanisme LBR (Sumber: Naeim, F dan Kelly, J.M, 1999) Rasio antara K dengan K 1 disebut post yield stiffness ratio ( ) ditulis dengan Persamaan berikut: α = K K 1 (1) Dimana: : K : K 1 : post yield stiffness ratio kekakuan pasca leleh kekakuan awal base isolator Variasi nilai post yield stiffness rasio mempengaruhi K 1, K, dan kekauan efektif (K eff ), sehingga respon struktur yang dihasilkan akan bervarisi tergantung dari nilai post yield stiffness ratio yang digunakan. 171

4 K eff dihitung dengan Persamaan: K eff = K + Q D () Dimana: K eff : kekakuan efektif Q : kekuatan karakteristik D : perpindahan maksimum yang terjadi pada slider isolator.3 Waktu Getar Alami Struktur Menurut Budiono (011), semakin besar periode struktur maka nilai kekakuan struktur semakin kecil, begitu juga sebaliknya. Berdasarkan SNI ,terdapat dua nilai batas untuk periode bangunan, yaitu nilai minimum periode bangunan (T a minumum ) dan nilai maksimum periode bangunan (T a maksimum). Menurut Anonim (01), penentuan simpangan antar lantai tingkat desain ( ) harus dihitung sebagai perbedaan defleksi pada pusat massa tingkat teratas dan terbawah yang ditinjau seperti pada Gambar 3. Apabila tidak terletak segaris dalam arah vertikal, diizinkan untuk menghitung defleksi di tingkat dasar berdasarkan proyeksi vertikal dari pusat massa tingkat diatasnya. Gambar 3. Penentuan Simpangan Antar Lantai Berdasarkan SNI (Sumber: SNI , 01) 3. METODE PENELITIAN 3.1 Geometri Model Gedung yang dianalisis merupakan bangunan gedung beton bertulang SRPMK 10 lantai dengan tinggi setiap lantai 4 m. Pemodelan struktur dilakukan terhadap kondisi yaitu, struktur gedung fixed base dan base isolated. Fungsi gedung adalah untuk perkantoran dengan berjarak 5 km dari pantai, diasumsikan terletak di Kota Banda Aceh dan bangunan terletak di kelas situs SD (tanah sedang). Gambar geometri denah gedung ditunjukkan pada Gambar 4. Pemodelan struktur bangunan gedung dilakukan dengan program SAP000 v.19. Pada struktur base isolated terdiri dari 4 model dengan variasi nilai kekakuan pasca leleh (K ) seperti diuraikan pada Tabel. 17

5 Tabel Simulasi Pemodelan Struktur Gambar 4. Denah Pemodelan Struktur No. Model Struktur K 1 Fixed base GTB GBI GBI Base Isolated 4 GBI GBI Keterangan: GTB : Struktur fixed base GBI 1 : Struktur dengan base isolator tipe 1 GBI : Struktur dengan base isolator tipe GBI 3 : Struktur dengan base isolator tipe 3 GBI 4 : Strukturdengan base isolator tipe 4 3. Pemodelan Base isolator langkah-langkah yang dijadikan dasar dalam memilih jenis LRB yang digunakan yaitu: a. Menentukan gaya aksial maksimum bangunan dari struktur dari masing-masing kolom berdasarkan beban-beban yang telah direncanakan sebelumnya; b. Menentukan dimensi LRB yang digunakan berdasarkan gaya aksial maksimum kolom; c. Menghitung redaman, tekuk dan stabilitas LRB Penambahan parameter pada LRB dilakukan dengan kekakuan pasca leleh (K ) berdasarkan data LRB yang digunakan. variasi nilai K yang digunakan adalah 0,7; 1,00; 1,0; dan 1,0 denagan adalah 0,. Simulasi pemodelan parameter LRB adalah seperti pada Tabel. 3.3 Analisis Pushover Tahapan analisis pushover pada struktur fixed base dan base isolated adalah sebagai berikut: a. Setelah struktur aman maka dilanjutkan dengan define properties sendi plastis pada elemen balok dan kolom. b. Menjalankan analisis pushover dangan SAP000 v.19 secara otomatis; c. Melakukan plot kurva pushover, performance point, d. Mengevaluasi level kinerja struktur ketika titik kontrol tepat berada pada target perpindahan merupakan hal utama dari perencanaan berbasis kinerja. 173

6 Lantai Lantai Perioda (s) Jurnal Arsip Rekayasa Sipil dan Perencanaan 1(1): (018) 4. HASIL DAN PEMBAHASAN 4.1 Hasil Hasil analisis menunjukkan waktu getar alami struktur base isolated lebih besar dibandingkan dengan struktur fixed based. Waktu getar alami struktur terjadi penurunan seiring dengan pertambahan kekakuan awal pada base isolator. Grafik perbandingan waktu getar alami struktur fixed base dan base isolated dapat lihat pada Gambar 5 berikut: 3,000,500,000 1,500 1,000 0,500 0,000 GBI 1 GBI GBI 3 GBI 4 GTB,63,533,490,41 1,798-0,500 1,000 1,500 Kekakuan Pasca Leleh, K (kn/mm) Fixed base Base isolator Gambar 5. Grafik periode struktur fixed base dan base isolated dengan variasi nilai k Gambar 6 dan 7 menampilkan grafik perbandingan displacement struktur fixed base dan base isolated. Displacement pada lantai dasar sruktur base isolated memiliki nilai yang lebih besar dibandingkan srtuktur bangunan fixed base. Pada struktur fixed base dasar bangunan tidak terjadi perpindahan karena ditahan oleh pondasi. Displacement terbesar pada GTB yaitu sebesar m dalam arah y, sedangkan pada struktur base isolated pada GB I yaitu m dalam arah x ,0000 0,1000 0,000 0,3000 0,4000 Displacement (m) Gambar 6. Displacement Arah x ' = 0.0 GTB GBI 1 (K = 0.70) GBI (K = 0.10) GBI 3 (K = 1.0) GBI 4 (K = 1.40) ,000 0,100 0,00 0,300 0,400 0,500 Displacement (m) Gambar 7. Displacement Arah y ' = 0.0 GTB GBI 1 (K = 0.70) GBI (K = 0.10) GBI 3 (K = 1.0) GBI 4 (K = 1.40) 174

7 Lantai Lantai Jurnal Arsip Rekayasa Sipil dan Perencanaan 1(1): (018) Interstory drift dianalisis berdasarkan nilai target perpindahan yang telah diperoleh kemudian dievaluasi berdasarkan persyaratan SNI Perbandingan interstory drift arah x dan y struktur fixed base dan base isolated dapat dilihat pada Gambar 8 dan 9. Interstory drift lantai 1 dan struktur base isolated variasi nilai K lebih besar dari struktur fixed base. Pada lantai 3 sampai 10 interstory drift struktur base isolated lebih kecil daripada struktur fixed base. Hal ini dipengaruhi oleh adanya perpindahan dasar pada struktur akibat penggunaan base isolator. Bangunan yang menggunakan base isolator memiliki nilai interstory drift lebih mendekati nol dari pada struktur fixed based. Interstory drift maksimum struktur fixed base terjadi pada lantai 4 dan struktur base isolated terjadi pada lantai 1. Dari hasil perhitungan interstory drift untuk struktur fixed base dan base isalated untuk masing-masing model memenuhi persyaratan yang diizinkan SNI ' = GTB 5 GBI 1 (K = 0.70) 4 GBI (K = 1.00) 3 GBI 3 (K3 = 1.0) GBI 4 (K = 1.40) 1 SNI ,0000 0,000 0,0400 0,0600 0,0800 0,1000 Interstory Drift (m) Gambar 8. Interstory Drift Arah x ' = GTB 4 GBI 1 (K = 0.70) 3 GBI (K = 1.00) GBI 3 (K = 1.0) 1 GBI 4 (K = 1.40) 0 SNI ,0000 0,000 0,0400 0,0600 0,0800 0,1000 Interstory Drift (m) Gambar 9. Interstory Drift Arah y Eveluasi kinerja menurut ATC 40 berdasarkan nilai maksimum interstory drift seperti pada Tabel 1. Interstory drift masksimum arah x dan y pada struktur fixed base dan base isolated dapat dilihat pada Tabel 3. Mengacu pada ATC 40 nilai interstory drift maksimum pada struktur fixed base dan base isolated untuk arah x da y berada pada nilai 0.01 m 0.0 sehingga kinerja struktur berada pada level Damage Control. 175

8 Tabel 3 Tingkat Kinerja Struktur Fixed Base dan Base Isolator Berdasarkan ATC 40 ATC 40 Model Struktur K Maksimum interstory Drift (m) Arah x Arah y Fixed base GTB GBI Base isolated GBI GBI GBI Kriteria Kinerja Struktur Damage Control 4. Pembahasan Berdasarkan hasil penelitian yang diperoleh seperti pada Gambar 7 menunjukkan penggunaan base isolator dapat memperpanjang periode struktur bangunan. Peride struktur fixed base adalah s sedangkan pada strukur gedung base isolated (GBI 1; GBI ; GBI 3; GBI 4) mengalami penurunan seiring dengan peningkatan nilai K. Penurunan nilai periode seiring dengan meningkatnya K menunjukkan semakin kaku suatu struktur maka periode semakin kecil. Peningkatan periode struktur menyebabkan interstory drift dan gaya gempa yang bekerja pada bangunan menjadi lebih kecil. Tabel 4 Peningkatan Periode Struktur Bangunan No. Model Struktur K Perioda Peningkatan perioda kn/mm (s) kali 1 Fixed base GTB GBI GBI Base isolated 4 GBI GBI Pada lantai dasar bangunan base isolated memiliki displacement yang lebih besar daripada bangunan fixed base. Pada bangunan fixed base tidak terjadi perpindahan karena dasar bangunan ditahan oleh pondasi. Perpindahan dasar pada bangunan dengan base isolator terjadi karena LRB yang terletak didasar bangunan base isolator memiliki kekakuan yang lebih kecil dan sangat fleksibel dalam arah horizontal. Displacement yang terjadi dalam arah x dan y ditinjau pada lantai 3 dan 6. Pada lantai 3 displacement bangunan masih besar akibat perpindahan dasar bangunan oleh base isolator dibandingkan dengan bangunan fixed base. Pada ke-6 nilai perpindahan pada tiap lantai bangunan base isolator tidak besar, menandakan bentuk displacement tidak lagi mengikuti efek gempa. Pemakaian base isolator pada bangunan akan memperbesar deformasi pada lantai dasar namun memperkecil perbedaan simpangan tiap lantai, sehingga membuat bangunan bergerak sebagai satu kesatuan struktur yang kaku ketika terjadi gempa. Hasil analisis top displacement diperoleh bahwa bangunan base isolator dibandingkan dengan bangunan fixed base maka nilai displacement dapat direduksi rata-rata mencapai 1.93% untuk arah x dan % pada arah y, Berdasarkan Gambar Gambar 8 dan 9 interstory drift terbesar terjadi pada bangunan fixed base kemudian diikuti bangunan dengan base isolator Interstory drift bangunan yang menggunakan base isolator lebih kecil daripada bangunan fixed base untuk arah x dan y. Bangunan dengan base isolator memiliki nilai simpangan antar lantai mendekati nol. Kerusakan bangunan dapat direduksi serta 176

9 membutuhkan waktu yang lebih singkat untuk mencapai partisipadi modal yang diinginkan. Bangunan dengan sistem base isolator lebih baik digunakan daripada bangunan fixed base, terlebih pada daerah rawan gempa yang memiliki skala besar. Kinerja struktur dievaluasi berdasarkan nilai maksimum drift struktur ketika mencapai performance point. Perbanding performance point untuk masing-masing model struktur dapat dilihat pada Tabel 5. Tabel 5 Perbandingan Performance Point Model Struktur Pecepatan Spektra, g Performance Point Perpindahan Spektra, m Sumbu x Sumbu y Sumbu x Sumbu y GTB GBI GBI GBI GBI Mengacu pada ATC 40 nilai interstory drift maksimum pada struktur fixed base dan base isolated untuk arah x da y berada pada nilai 0,01 0,0 m sehingga kinerja struktur pada GTB; GBI ; GBI 3; dan GBI 4 berada pada level Damage Control. 5 KESIMPULAN DAN SARAN 5.1 Kesimpulan Berdasarkan hasil penelitian yang telah dilakukan maka dapat diambil beberapa kesimpulan sebagai berikut: 1. Penggunaan base isolator dengan pada struktur gedung dapat memperbesar periode alami struktur. Peningkatan periode alami struktur dengan base isolator dibandingkan dengan struktur fixed base ratarata mencapai dan kali;. Simpangan antar lantai (interstory drift) pada struktur dengan base isolator lebih kecil dibandingkan dengan struktur fixed base baik dalam arah x maupun y. Hal ini menyebabkan gaya gempa yang bekerja pada struktur menjadi lebih kecil. 3. Pemakaian isolator pada bangunan memperbesar perpindahan lateral (displacement) pada lantai dasar namun memperkecil interstory drift, sehingga membuat bangunan bergerak sebagai satu kesatuan struktur yang kaku ketika terjadi gempa. 4. Pemakaian isolator dapat mereduksi top displament rata-rata mencapai 1.93% untuk arah x dan % pada arah y, 5. Hasil eveluasi berdasarkan interstory drift maksimum. Interstory drift maksimum pada struktur fixed base dan base isolated untuk arah x da y berada pada nilai 0.01 m 0.0 sehingga kinerja struktur berada pada level Damage Control. 5. Saran Berdasarkan hasil penelitian diberikan beberapa saran berikut: 1. Melakukan analisis pada struktur gedung tidak beraturan dengan menggunakan base isolator tipe lain seperti Elactomeric Rubber Bearing (ERB), Friction Pendulum System (FPS), High Dumping Rubber Bearing (HDRB); 177

10 . Penggunaan base isolator pada struktur dengan sistem penahan gaya seismik lainnya, seperti Rangka Baja Pemikul Momen Khusus DAFTAR PUSTAKA Anonim, 01, Tata Cara Perencanaan Ketahanan gempa untuk Struktur Banguna gedung dan Non Gedung, SNI , Bandung. Anonim, 000, Prestandart and Commentary for The Seismic Rehabilitation of Building, FEMA-356, Washington, D.C. Anonim,1996, Seismic Evaliation and Retrofit of Concrete, Vol. 1, ACT-40, California. Bisch, P., Carvalho, E., dan Degee, H., 011, Seismic Design of Building Worked Examples, (EC 8), Luxembourg, European Union. Budiono, B dan Lucky.S, 011, Studi Komparasi Desain Bangunan Tahan Gempa Dengan Menggunakan SNI dan RSNI x, Penerbit ITB, Bandung. Dewobroto, W., 005, Evaluasi Kinerja Portal Baja Tahan Gempa Dengan SAP000, http: wira@uph.edu. Erista, D., 011, Kajian Parameter Base Isolator Terhadap Respon Bangunan Akibat Gaya Gempa dengan Menggunakan Analisis Riwayat Waktu, Tugas Akhir, Universitas Sumatera Utara, Medan. Marsico, M.R., Seismic Isolation and Energy Dissipation: Theorical Basis and Applications, Thesis, Universitas Degli Studi di Napoli Federico II. Naeim, F., and Kelly, J.M., 1999,Design of Seismic Isolated Structures: From Theory to Practice., Jhon Wiley & Sons, Inc, New York. Teruna, D.R, 005, Analisis Respon Bangunan dengan Base Isolator Akibat Gaya Gempa, Jurnal Sistem Teknik Industri Volume 6, No. 4 Oktober 005 Hal. 58 s/d 63, Oktober 005. Yang, B.Y., Chang, C.K., dan Yau, D.J. (003), Earthquake Engineering Handbook Chapter 17 Base Isolation, National Taiwan University, Taipe. 178

BAB I PENDAHULUAN. Dalam perencanaan suatu bangunan tahan gempa, filosofi yang banyak. digunakan hampir di seluruh negara di dunia yaitu:

BAB I PENDAHULUAN. Dalam perencanaan suatu bangunan tahan gempa, filosofi yang banyak. digunakan hampir di seluruh negara di dunia yaitu: BAB I PENDAHULUAN 1.1 LATAR BELAKANG Indonesia adalah salah satu negara di dunia yang rawan akan gempa bumi. Hal ini disebabkan Indonesia dilalui dua jalur gempa dunia, yaitu jalur gempa asia dan jalur

Lebih terperinci

EVALUASI KEMAMPUAN STRUKTUR RUMAH TINGGAL SEDERHANA AKIBAT GEMPA

EVALUASI KEMAMPUAN STRUKTUR RUMAH TINGGAL SEDERHANA AKIBAT GEMPA EVALUASI KEMAMPUAN STRUKTUR RUMAH TINGGAL SEDERHANA AKIBAT GEMPA Gerry F. Waworuntu M. D. J. Sumajouw, R. S. Windah Fakultas Teknik, Jurusan Teknik Sipil, Universitas Sam Ratulangi email: gerrywaw@gmail.com

Lebih terperinci

Pengaruh Core terhadap Kinerja Seismik Gedung Bertingkat

Pengaruh Core terhadap Kinerja Seismik Gedung Bertingkat Reka Racana Teknik Sipil Itenas Vol. 2 No. 1 Jurnal Online Institut Teknologi Nasional Maret 2016 Pengaruh Core terhadap Kinerja Seismik Gedung Bertingkat MEKY SARYUDI 1, BERNARDINUS HERBUDIMAN 2, 1 Mahasiswa,

Lebih terperinci

BAB II TINJAUAN PUSTAKA

BAB II TINJAUAN PUSTAKA BAB II TINJAUAN PUSTAKA 2.1 Perancanaan Tahan Gempa Berbasis Kinerja Menurut Muntafi (2012) perancangan bangunan tahan gempa selama ini analisis terhadap gempa menggunakan metode Force Based Design, dan

Lebih terperinci

KAJIAN EFEK PARAMETER BASE ISOLATOR TERHADAP RESPON BANGUNAN AKIBAT GAYA GEMPA DENGAN METODE ANALISIS RIWAYAT WAKTU DICKY ERISTA

KAJIAN EFEK PARAMETER BASE ISOLATOR TERHADAP RESPON BANGUNAN AKIBAT GAYA GEMPA DENGAN METODE ANALISIS RIWAYAT WAKTU DICKY ERISTA KAJIAN EFEK PARAMETER BASE ISOLATOR TERHADAP RESPON BANGUNAN AKIBAT GAYA GEMPA DENGAN METODE ANALISIS RIWAYAT WAKTU TUGAS AKHIR DICKY ERISTA 06 0404 106 BIDANG STUDI STRUKTUR DEPARTEMEN TEKNIK SIPIL FAKULTAS

Lebih terperinci

II. KAJIAN LITERATUR. tahan gempa apabila memenuhi kriteria berikut: tanpa terjadinya kerusakan pada elemen struktural.

II. KAJIAN LITERATUR. tahan gempa apabila memenuhi kriteria berikut: tanpa terjadinya kerusakan pada elemen struktural. 5 II. KAJIAN LITERATUR A. Konsep Bangunan Tahan Gempa Secara umum, menurut UBC 1997 bangunan dikatakan sebagai bangunan tahan gempa apabila memenuhi kriteria berikut: 1. Struktur yang direncanakan harus

Lebih terperinci

PENGARUH SENSITIFITAS DIMENSI DAN PENULANGAN KOLOM PADA KURVA KAPASITAS GEDUNG 7 LANTAI TIDAK BERATURAN

PENGARUH SENSITIFITAS DIMENSI DAN PENULANGAN KOLOM PADA KURVA KAPASITAS GEDUNG 7 LANTAI TIDAK BERATURAN Konferensi Nasional Teknik Sipil 3 (KoNTekS 3) Jakarta, 6 7 Mei 2009 PENGARUH SENSITIFITAS DIMENSI DAN PENULANGAN KOLOM PADA KURVA KAPASITAS GEDUNG 7 LANTAI TIDAK BERATURAN Nurlena Lathifah 1 dan Bernardinus

Lebih terperinci

BAB 1 PENDAHULUAN. yaitu di kepulauan Alor (11 Nov, skala 7.5), gempa Papua (26 Nov, skala 7.1),

BAB 1 PENDAHULUAN. yaitu di kepulauan Alor (11 Nov, skala 7.5), gempa Papua (26 Nov, skala 7.1), BAB 1 PENDAHULUAN 1.1 Latar Belakang Masalah Indonesia terletak dalam wilayah rawan gempa dengan intensitas moderat hingga tinggi. Terbukti pada tahun 2004, tercatat tiga gempa besar di Indonesia, yaitu

Lebih terperinci

ANALISIS KINERJA STRUKTUR BETON BERTULANG DI WILAYAH GEMPA INDONESIA INTENSITAS TINGGI DENGAN KONDISI TANAH LUNAK

ANALISIS KINERJA STRUKTUR BETON BERTULANG DI WILAYAH GEMPA INDONESIA INTENSITAS TINGGI DENGAN KONDISI TANAH LUNAK ANALISIS KINERJA STRUKTUR BETON BERTULANG DI WILAYAH GEMPA INDONESIA INTENSITAS TINGGI DENGAN KONDISI TANAH LUNAK Sri Fatma Reza 1, Reni Suryanita 2 dan Ismeddiyanto 3 1,2,3 Jurusan Teknik Sipil/Universitas

Lebih terperinci

JURNAL TEKNIK ITS Vol. 6, No. 2 (2017), ( X Print)

JURNAL TEKNIK ITS Vol. 6, No. 2 (2017), ( X Print) JURNAL TEKNIK ITS Vol. 6, No. 2 (2017), 2337-3520 (2301-928X Print) C624 Evaluasi Kinerja Gedung Menggunakan Base Isolation Tipe High Damping Rubber Bearing (HDRB) Pada Modifikasi Gedung J-Tos Jogjakarta

Lebih terperinci

BAB V ANALISIS DAN PEMBAHASAN

BAB V ANALISIS DAN PEMBAHASAN BAB V ANALISIS DAN PEMBAHASAN Pada bagian ini akan dianalisis periode struktur, displacement, interstory drift, momen kurvatur, parameter aktual non linear, gaya geser lantai, dan distribusi sendi plastis

Lebih terperinci

EVALUASI KINERJA GEDUNG BETON BERTULANG SISTEM GANDA DENGAN VARIASI GEOMETRI DINDING GESER PADA WILAYAH GEMPA KUAT

EVALUASI KINERJA GEDUNG BETON BERTULANG SISTEM GANDA DENGAN VARIASI GEOMETRI DINDING GESER PADA WILAYAH GEMPA KUAT ISSN 2302-0253 13 Pages pp. 70-82 EVALUASI KINERJA GEDUNG BETON BERTULANG SISTEM GANDA DENGAN VARIASI GEOMETRI DINDING GESER PADA WILAYAH GEMPA KUAT Suhaimi 1, T. Budi Aulia 2, Mochammad Afifuddin 2 1)

Lebih terperinci

BAB II TINJAUAN PUSTAKA

BAB II TINJAUAN PUSTAKA BAB II TINJAUAN PUSTAKA 2.1 Analisis Statik Beban Dorong (Static Pushover Analysis) Menurut SNI Gempa 03-1726-2002, analisis statik beban dorong (pushover) adalah suatu analisis nonlinier statik, yang

Lebih terperinci

BAB III METODE ANALISA STATIK NON LINIER

BAB III METODE ANALISA STATIK NON LINIER BAB III METODE ANALISA STATIK NON LINIER Metode analisa riwayat waktu atau Time History analysis merupakan metode analisa yang paling lengkap dan representatif, akan tetapi metode tersebut terlalu rumit

Lebih terperinci

BAB III METODE ANALISIS

BAB III METODE ANALISIS BAB III METODE ANALISIS Pada tugas akhir ini, model struktur yang telah dibuat dengan bantuan software ETABS versi 9.0.0 kemudian dianalisis dengan metode yang dijelaskan pada ATC-40 yaitu dengan analisis

Lebih terperinci

PENDAHULUAN Perencanaan gedung tahan gempa telah menjadi perhatian khusus mengingat telah banyak terjadi gempa cukup besar akhir-akhir ini. Perencanaa

PENDAHULUAN Perencanaan gedung tahan gempa telah menjadi perhatian khusus mengingat telah banyak terjadi gempa cukup besar akhir-akhir ini. Perencanaa EVALUASI KINERJA STRUKTUR BAJA TAHAN GEMPA DENGAN PUSHOVER ANALYSIS 1 Agung Sugiyatno 2 Sulardi, ST., MT 1 ancient_agoenk@yahoo.com 2 lardiardi@yahoo.com Jurusan Teknik Sipil, Fakultas Teknik Sipil dan

Lebih terperinci

BAB I PENDAHULUAN. Perencanaan Tahan Gempa Indonesia Untuk Gedung (PPTGIUG, 1981) maupun di

BAB I PENDAHULUAN. Perencanaan Tahan Gempa Indonesia Untuk Gedung (PPTGIUG, 1981) maupun di BAB I PENDAHULUAN 1.1 LATAR BELAKANG Wilayah-wilayah gempa yang ada di Indonesia sudah disajikan baik di Peraturan Perencanaan Tahan Gempa Indonesia Untuk Gedung (PPTGIUG, 1981) maupun di Tata Cara Perencanaan

Lebih terperinci

Pengaruh Bentuk Bracing terhadap Kinerja Seismik Struktur Beton Bertulang

Pengaruh Bentuk Bracing terhadap Kinerja Seismik Struktur Beton Bertulang Reka Racana Jurusan Teknik Sipil Itenas Vol.3 No. 1 Jurnal Online Institut Teknologi Nasional Maret 2017 Pengaruh Bentuk Bracing terhadap Kinerja Seismik Struktur Beton Bertulang DARIN ARYANDI, BERNARDINUS

Lebih terperinci

PENELITIAN MENGENAI SNI 1726:2012 PASAL TENTANG DISTRIBUSI GAYA LATERAL TERHADAP KEKAKUAN, KEKUATAN, DAN PENGECEKAN TERHADAP SISTEM TUNGGAL

PENELITIAN MENGENAI SNI 1726:2012 PASAL TENTANG DISTRIBUSI GAYA LATERAL TERHADAP KEKAKUAN, KEKUATAN, DAN PENGECEKAN TERHADAP SISTEM TUNGGAL PENELITIAN MENGENAI SNI 172:2012 PASAL 7.2.5.1 TENTANG DISTRIBUSI GAYA LATERAL TERHADAP KEKAKUAN, KEKUATAN, DAN PENGECEKAN TERHADAP SISTEM TUNGGAL Bernard Thredy William Wijaya 1, Nico 2, Hasan Santoso

Lebih terperinci

EVALUASI KINERJA STRUKTUR BETON BERTULANG DENGAN PUSHOVER ANALYSIS

EVALUASI KINERJA STRUKTUR BETON BERTULANG DENGAN PUSHOVER ANALYSIS EVALUASI KINERJA STRUKTUR BETON BERTULANG DENGAN PUSHOVER ANALYSIS Yogi Oktopianto 1 Relly Andayani 2 1,2 Jurusan Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan Universitas Gunadarma Jalan Margonda

Lebih terperinci

EVALUASI BALOK DAN KOLOM PADA RUMAH SEDERHANA

EVALUASI BALOK DAN KOLOM PADA RUMAH SEDERHANA EVALUASI BALOK DAN KOLOM PADA RUMAH SEDERHANA Christy Merril Rantung Marthin D. J. Sumajouw, Reky S. Windah Fakultas Teknik, Jurusan Teknik Sipil, Universitas Sam Ratulangi Manado email: christyrantung@ymail.com

Lebih terperinci

BAB II DASAR TEORI. Pada bab ini akan dibahas sekilas tentang konsep Strength Based Design dan

BAB II DASAR TEORI. Pada bab ini akan dibahas sekilas tentang konsep Strength Based Design dan BAB II DASAR TEORI II.1 Umum Pada bab ini akan dibahas sekilas tentang konsep Strength Based Design dan uraian konsep Performance Based Design, yang selanjutnya akan lebih terfokus pada perencanaan struktur

Lebih terperinci

ANALISIS STRUKTUR RANGKA BAJA MENGGUNAKAN BASE ISOLATION DENGAN TIME HISTORY ANALYSIS

ANALISIS STRUKTUR RANGKA BAJA MENGGUNAKAN BASE ISOLATION DENGAN TIME HISTORY ANALYSIS Vol. 4, No., Oktober 5, Halaman: - 6, ISSN: 97-447 (Print), ISSN: 477-4863 (Online) Alamat Website: http://cantilever.unsri.ac.id ANALISIS STRUKTUR RANGKA BAJA MENGGUNAKAN BASE ISOLATION DENGAN TIME HISTORY

Lebih terperinci

STUDI KINERJA SENDI PLASTIS PADA GEDUNG DAKTAIL PARSIAL DENGAN ANALISIS BEBAN DORONG

STUDI KINERJA SENDI PLASTIS PADA GEDUNG DAKTAIL PARSIAL DENGAN ANALISIS BEBAN DORONG STUDI KINERJA SENDI PLASTIS PADA GEDUNG DAKTAIL PARSIAL DENGAN ANALISIS BEBAN DORONG Muhammad Ujianto 1, Wahyu Ahmat Hasan Jaenuri 2, Yenny Nurchasanah 3 1,2,3 Prodi Teknik Sipil, Fakultas Teknik, Universitas

Lebih terperinci

PEMODELAN STRUKTUR BANGUNAN GEDUNG BERTINGKAT BETON BERTULANG RANGKA TERBUKA SIMETRIS DI DAERAH RAWAN GEMPA DENGAN METODA ANALISIS PUSHOVER

PEMODELAN STRUKTUR BANGUNAN GEDUNG BERTINGKAT BETON BERTULANG RANGKA TERBUKA SIMETRIS DI DAERAH RAWAN GEMPA DENGAN METODA ANALISIS PUSHOVER PEMODELAN STRUKTUR BANGUNAN GEDUNG BERTINGKAT BETON BERTULANG RANGKA TERBUKA SIMETRIS DI DAERAH RAWAN GEMPA DENGAN METODA ANALISIS PUSHOVER S-2 Siti Aisyah N. 1* dan Yoga Megantara 2 1 Balai Diklat Wilayah

Lebih terperinci

PERENCANAAN STRUKTUR BAJA BERDASARKAN KEKAKUAN DAN KEKUATAN SISTEM GANDA SRPMK DAN SRBE BENTUK DIAGONAL MENURUT SNI 1726:2012 PASAL

PERENCANAAN STRUKTUR BAJA BERDASARKAN KEKAKUAN DAN KEKUATAN SISTEM GANDA SRPMK DAN SRBE BENTUK DIAGONAL MENURUT SNI 1726:2012 PASAL PERENCANAAN STRUKTUR BAJA BERDASARKAN KEKAKUAN DAN KEKUATAN SISTEM GANDA SRPMK DAN SRBE BENTUK DIAGONAL MENURUT SNI 1726:2012 PASAL 7.2.5.1 Hendri Sugiarto Mulia 1, Stefanus Edwin 2, Hasan Santoso 3, dan

Lebih terperinci

Evaluasi Kinerja Gedung Beton Bertulang Dengan Pushover Analysis Akibat Beban Gempa Padang

Evaluasi Kinerja Gedung Beton Bertulang Dengan Pushover Analysis Akibat Beban Gempa Padang Evaluasi Kinerja Gedung Beton Bertulang Dengan Pushover Analysis Akibat Beban Gempa Padang Vicky Rizcky, Endah Wahyuni ST., MSc., PhD dan Data Iranata ST., MT., PhD Jurusan Teknik Sipil, Fakultas Teknik

Lebih terperinci

ANALISIS KINERJA STRUKTUR BETON BERTULANG DENGAN VARIASI PENEMPATAN BRACING INVERTED V ABSTRAK

ANALISIS KINERJA STRUKTUR BETON BERTULANG DENGAN VARIASI PENEMPATAN BRACING INVERTED V ABSTRAK VOLUME 12 NO. 2, OKTOBER 2016 ANALISIS KINERJA STRUKTUR BETON BERTULANG DENGAN VARIASI PENEMPATAN BRACING INVERTED V Julita Andrini Repadi 1, Jati Sunaryati 2, dan Rendy Thamrin 3 ABSTRAK Pada studi ini

Lebih terperinci

BAB I PENDAHULUAN. adalah kolom. Kolom termasuk struktur utama yang bertujuan menyalurkan beban tekan

BAB I PENDAHULUAN. adalah kolom. Kolom termasuk struktur utama yang bertujuan menyalurkan beban tekan BAB I PENDAHULUAN 1.1 Latar Belakang Masalah Di Indonesia sering terjadinya gempa bumi dan hampir selalu menelan korban jiwa. Namun dapat dipastikan bahwa korban jiwa tersebut bukan diakibatkan oleh gempa

Lebih terperinci

JURNAL TUGAS AKHIR STUDI KEANDALAN STRUKTUR GEDUNG TINGGI TIDAK BERATURAN MENGGUNAKAN PUSHOVER ANALYSIS PADA TANAH MEDIUM

JURNAL TUGAS AKHIR STUDI KEANDALAN STRUKTUR GEDUNG TINGGI TIDAK BERATURAN MENGGUNAKAN PUSHOVER ANALYSIS PADA TANAH MEDIUM JURNAL TUGAS AKHIR STUDI KEANDALAN STRUKTUR GEDUNG TINGGI TIDAK BERATURAN MENGGUNAKAN PUSHOVER ANALYSIS PADA TANAH MEDIUM OLEH : ULFA NURDIANTI D111 08 304 JURUSAN SIPIL FAKULTAS TEKNIK UNIVERSITAS HASANUDDIN

Lebih terperinci

BAB I PENDAHULUAN. 1.1 Latar Belakang

BAB I PENDAHULUAN. 1.1 Latar Belakang BAB I PENDAHULUAN 1.1 Latar Belakang Desain bangunan tahan gempa sangat penting untuk dilakukan pada bangunan yang berada dalam zona gempa tertentu, khususnya di Indonesia mengingat kondisinya yang berada

Lebih terperinci

Studi Assessment Kerentanan Gedung Beton Bertulang Terhadap Beban Gempa Dengan Menggunakan Metode Pushover Analysis

Studi Assessment Kerentanan Gedung Beton Bertulang Terhadap Beban Gempa Dengan Menggunakan Metode Pushover Analysis Studi Assessment Kerentanan Gedung Beton Bertulang Terhadap Beban Gempa Dengan Menggunakan Metode Pushover Analysis Windya Dirgantari, Endah Wahyuni dan Data Iranata Jurusan Teknik Sipil, Fakultas Teknik

Lebih terperinci

KATA KUNCI : direct displacement based design, time history analysis, kinerja struktur.

KATA KUNCI : direct displacement based design, time history analysis, kinerja struktur. PEMILIHAN LEVEL KINERJA STRUKTUR PADA BANGUNAN SISTEM RANGKA BETON BERTULANG PEMIKUL MOMEN YANG DIRENCANAKAN SECARA DIRECT DISPLACEMENT BASED DESIGN STUDI KASUS : BANGUNAN BERATURAN DENGAN BENTANG SERAGAM

Lebih terperinci

EVALUASI SNI 1726:2012 PASAL MENGENAI DISTRIBUSI GAYA LATERAL TERHADAP KEKAKUAN DAN KEKUATAN PADA SISTEM GANDA SRPMK DAN SRBKK

EVALUASI SNI 1726:2012 PASAL MENGENAI DISTRIBUSI GAYA LATERAL TERHADAP KEKAKUAN DAN KEKUATAN PADA SISTEM GANDA SRPMK DAN SRBKK EVALUASI SNI 1726:2012 PASAL 7.2.5.1 MENGENAI DISTRIBUSI GAYA LATERAL TERHADAP KEKAKUAN DAN KEKUATAN PADA SISTEM GANDA SRPMK DAN SRBKK Andreas Jaya 1, Hary Winar 2, Hasan Santoso 3 dan Pamuda Pudjisuryadi

Lebih terperinci

Kajian Perilaku Struktur Portal Beton Bertulang Tipe SRPMK dan Tipe SRPMM

Kajian Perilaku Struktur Portal Beton Bertulang Tipe SRPMK dan Tipe SRPMM Jurnal Rekayasa Hijau No.3 Vol. I ISSN: 2550-1070 November 2017 Kajian Perilaku Struktur Portal Beton Bertulang Tipe SRPMK dan Tipe SRPMM Nur Laeli Hajati dan Rizki Noviansyah Jurusan Teknik Sipil, Institut

Lebih terperinci

Prosiding Seminar Nasional Teknik Sipil 1 (SeNaTS 1) Tahun 2015 Sanur - Bali, 25 April 2015

Prosiding Seminar Nasional Teknik Sipil 1 (SeNaTS 1) Tahun 2015 Sanur - Bali, 25 April 2015 Prosiding Seminar Nasional Teknik Sipil 1 (SeNaTS 1) Tahun 2015 Sanur - Bali, 25 April 2015 ANALISIS PERBANDINGAN EFISIENSI STRUKTUR BAJA DENGAN SISTEM RANGKA PEMIKUL MOMEN KHUSUS DAN SISTEM RANGKA BRESING

Lebih terperinci

ANALISIS KINERJA BANGUNAN BETON BERTULANG DENGAN LAYOUT BERBENTUK YANG MENGALAMI BEBAN GEMPA TERHADAP EFEK SOFT-STOREY SKRIPSI

ANALISIS KINERJA BANGUNAN BETON BERTULANG DENGAN LAYOUT BERBENTUK YANG MENGALAMI BEBAN GEMPA TERHADAP EFEK SOFT-STOREY SKRIPSI ANALISIS KINERJA BANGUNAN BETON BERTULANG DENGAN LAYOUT BERBENTUK YANG MENGALAMI BEBAN GEMPA TERHADAP EFEK SOFT-STOREY SKRIPSI Oleh : RONI SYALIM 07 172 043 JURUSAN TEKNIK SIPIL - FAKULTAS TEKNIK UNIVERSITAS

Lebih terperinci

DAFTAR ISI Annisa Candra Wulan, 2016 Studi Kinerja Struktur Beton Bertulang dengan Analisis Pushover

DAFTAR ISI Annisa Candra Wulan, 2016 Studi Kinerja Struktur Beton Bertulang dengan Analisis Pushover DAFTAR ISI HALAMAN JUDUL... i HALAMAN PENGESAHAN... ii HALAMAN PERNYATAAN... iii KATA PENGANTAR... iv UCAPAN TERIMAKASIH... v ABSTRAK... vii ABSTRACT... viii DAFTAR ISI... ix DAFTAR TABEL... xi DAFTAR

Lebih terperinci

EVALUASI KINERJA SEISMIK GEDUNG TERHADAP ANALISIS BEBAN DORONG

EVALUASI KINERJA SEISMIK GEDUNG TERHADAP ANALISIS BEBAN DORONG EVALUASI KINERJA SEISMIK GEDUNG TERHADAP ANALISIS BEBAN DORONG Yenny Nurchasanah 1, Wahyu Ahmat Hasan Jaenuri 2, Muhammad Ujianto 3 1,2,3 Prodi Teknik Sipil, Fakultas Teknik, Universitas Muhammadiyah Surakarta

Lebih terperinci

KATA KUNCI: sistem rangka baja dan beton komposit, struktur komposit.

KATA KUNCI: sistem rangka baja dan beton komposit, struktur komposit. EVALUASI KINERJA SISTEM RANGKA BAJA DAN BETON KOMPOSIT PEMIKUL MOMEN KHUSUS YANG DIDESAIN BERDASARKAN SNI 1729:2015 Anthony 1, Tri Fena Yunita Savitri 2, Hasan Santoso 3 ABSTRAK : Dalam perencanaannya

Lebih terperinci

JURNAL TEKNIK POMITS Vol. 1, No. 1, (2013) 1-6 1

JURNAL TEKNIK POMITS Vol. 1, No. 1, (2013) 1-6 1 JURNAL TEKNIK POMITS Vol. 1, No. 1, (2013) 1-6 1 STUDI PERILAKU BANGUNAN MULTI TOWER 15 LANTAI MENGGUNAKAN METODE NONLINEAR TIME HISTORY ANALYSIS DENGAN MEMBANDINGKAN DUA POSISI SHEAR WALL (STUDI KASUS

Lebih terperinci

BAB 1 PENDAHULUAN. Indo-Australia bertabrakan dengan lempeng Eurasia di lepas pantai Sumatra, Jawa

BAB 1 PENDAHULUAN. Indo-Australia bertabrakan dengan lempeng Eurasia di lepas pantai Sumatra, Jawa BAB 1 PENDAHULUAN 1.1 Latar Belakang Masalah [4, 5, 6] Indonesia merupakan daerah pertemuan tiga lempeng tektonik besar, yaitu lempeng Indo-Australia, Eurasia dan lempeng Pasifik (Gambar 1.1). Lempeng

Lebih terperinci

adalah momen pada muka joint, yang berhubungan dengan kuat lentur nominal balok pada hubungan balok. Kolom tersebut.

adalah momen pada muka joint, yang berhubungan dengan kuat lentur nominal balok pada hubungan balok. Kolom tersebut. BAB I PENDAHULUAN 1.1 Latar belakang Indonesia pada tahun 2009 ini mengalami gempa besar di daerah Padang dengan gempa tercatat 7.6 skala richter, banyak bangunan runtuh pada gempa ini dan ini menyadarkan

Lebih terperinci

ANALISA KINERJA STRUKTUR BETON BERTULANG DENGAN KOLOM YANG DIPERKUAT DENGAN LAPIS CARBON FIBER REINFORCED POLYMER (CFRP)

ANALISA KINERJA STRUKTUR BETON BERTULANG DENGAN KOLOM YANG DIPERKUAT DENGAN LAPIS CARBON FIBER REINFORCED POLYMER (CFRP) ANALISA KINERJA STRUKTUR BETON BERTULANG DENGAN KOLOM YANG DIPERKUAT DENGAN LAPIS CARBON FIBER REINFORCED POLYMER (CFRP) TUGAS AKHIR Oleh : I Putu Edi Wiriyawan NIM: 1004105101 JURUSAN TEKNIK SIPIL FAKULTAS

Lebih terperinci

BAB VI KESIMPULAN DAN SARAN. Perencanaan letak sendi plastis dengan menggunakan reduced beam

BAB VI KESIMPULAN DAN SARAN. Perencanaan letak sendi plastis dengan menggunakan reduced beam 77 BAB VI KESIMPULAN DAN SARAN 6.1 Kesimpulan Akibat reduced beam section (perencanaan letak sendi plastis) deformasi struktur menjadi lebih besar 35% daripada deformasi struktur yang tidak diberi perencanaan

Lebih terperinci

ANALISA PORTAL DENGAN DINDING TEMBOK PADA RUMAH TINGGAL SEDERHANA AKIBAT GEMPA

ANALISA PORTAL DENGAN DINDING TEMBOK PADA RUMAH TINGGAL SEDERHANA AKIBAT GEMPA ANALISA PORTAL DENGAN DINDING TEMBOK PADA RUMAH TINGGAL SEDERHANA AKIBAT GEMPA Rowland Badenpowell Edny Turang Marthin D. J. Sumajouw, Reky S. Windah Fakultas Teknik, Jurusan Teknik Sipil, Universitas

Lebih terperinci

ANALISIS PUSHOVER STRUKTUR BAJA PADA WILAYAH GEMPA KUAT (6) DENGAN STUDI KASUS STRUKTUR BANGUNAN BAJA BERATURAN

ANALISIS PUSHOVER STRUKTUR BAJA PADA WILAYAH GEMPA KUAT (6) DENGAN STUDI KASUS STRUKTUR BANGUNAN BAJA BERATURAN ABSTRACT ANALISIS PUSHOVER STRUKTUR BAJA PADA WILAYAH GEMPA KUAT (6) DENGAN STUDI KASUS STRUKTUR BANGUNAN BAJA BERATURAN Iskandar Jurusan Teknik Sipil Politeknik Negeri Lhokseumawe E-mail : isk_ab@yahoo.com

Lebih terperinci

Evaluasi Kinerja Struktur Jembatan akibat Beban Gempa dengan Analisis Riwayat Waktu

Evaluasi Kinerja Struktur Jembatan akibat Beban Gempa dengan Analisis Riwayat Waktu Evaluasi Kinerja Struktur Jembatan akibat Beban Gempa dengan Analisis Riwayat Waktu R. SURYANITA 1,* 1 Jurusan Teknik Sipil Fakultas Teknik Universitas Riau Jl. HR Soebrantas KM.12.5 Pekanbaru, Indonesia

Lebih terperinci

EVALUASI METODE FBD DAN DDBD PADA SRPM DI WILAYAH 2 DAN 6 PETA GEMPA INDONESIA

EVALUASI METODE FBD DAN DDBD PADA SRPM DI WILAYAH 2 DAN 6 PETA GEMPA INDONESIA EVALUASI METODE FBD DAN DDBD PADA SRPM DI WILAYAH DAN PETA GEMPA INDONESIA Ivan William Susanto, Patrik Rantetana, Ima Muljati ABSTRAK : Direct Displacement Based Design (DDBD) merupakan sebuah metode

Lebih terperinci

KINERJA STRUKTUR AKIBAT BEBAN GEMPA DENGAN METODE RESPON SPEKTRUM DAN TIME HISTORY

KINERJA STRUKTUR AKIBAT BEBAN GEMPA DENGAN METODE RESPON SPEKTRUM DAN TIME HISTORY KINERJA STRUKTUR AKIBAT BEBAN GEMPA DENGAN METODE RESPON SPEKTRUM DAN TIME HISTORY Rezky Rendra 1, Alex Kurniawandy 2, dan Zulfikar Djauhari 3 1,2, dan 3 Jurusan Teknik Sipil, Fakultas Teknik, Universitas

Lebih terperinci

BAB I PENDAHULUAN 1.1 LATAR BELAKANG

BAB I PENDAHULUAN 1.1 LATAR BELAKANG BAB I PENDAHULUAN 1.1 LATAR BELAKANG Negara Indonesia adalah salah satu negara yang dilintasi jalur cincin api dunia. Terdapat empat lempeng tektonik dunia yang ada di Indonesia, yaitu lempeng Pasific,

Lebih terperinci

DAFTAR ISI JUDUL LEMBAR PENGESAHAN PERNYATAAN BEBAS PLAGIAT PERSEMBAHAN KATA PENGANTAR DAFTAR GAMBAR DAFTAR TABEL DAFTAR NOTASI

DAFTAR ISI JUDUL LEMBAR PENGESAHAN PERNYATAAN BEBAS PLAGIAT PERSEMBAHAN KATA PENGANTAR DAFTAR GAMBAR DAFTAR TABEL DAFTAR NOTASI DAFTAR ISI JUDUL i LEMBAR PENGESAHAN ii LEMBAR PENGESAHAN iii PERNYATAAN BEBAS PLAGIAT iv PERSEMBAHAN v KATA PENGANTAR vi DAFTAR ISI viii DAFTAR GAMBAR xi DAFTAR TABEL xiv DAFTAR NOTASI xvi ABSTRAK xix

Lebih terperinci

BAB I PENDAHULUAN 1.1 Latar Belakang

BAB I PENDAHULUAN 1.1 Latar Belakang BAB I PENDAHULUAN 1.1 Latar Belakang Indonesia berada pada jalur gempa pasifik ( Circum Pacific Earthquake Belt) dan jalur gempa Asia (Trans Asiatic Earthquake Belt) sehingga mengakibatkan tingkat resiko

Lebih terperinci

DAFTAR ISI. BAB II TINJAUAN PUSTAKA Umum Beban Gempa Menurut SNI 1726: Perkuatan Struktur Bresing...

DAFTAR ISI. BAB II TINJAUAN PUSTAKA Umum Beban Gempa Menurut SNI 1726: Perkuatan Struktur Bresing... DAFTAR ISI PERNYATAAN... i ABSTRAK... ii UCAPAN TERIMA KASIH... iii DAFTAR ISI... v DAFTAR GAMBAR... vii DAFTAR TABEL... ix BAB I PENDAHULUAN... 1 1.1 Latar Belakang... 1 1.2 Rumusan Masalah... 2 1.3 Tujuan...

Lebih terperinci

) DAN ANALISIS PERKUATAN KAYU GLULAM BANGKIRAI DENGAN PELAT BAJA

) DAN ANALISIS PERKUATAN KAYU GLULAM BANGKIRAI DENGAN PELAT BAJA ABSTRAK STUDI ANALISIS KINERJA BANGUNAN 2 LANTAI DAN 4 LANTAI DARI KAYU GLULAM BANGKIRAI TERHADAP BEBAN SEISMIC DENGAN ANALISIS STATIC NON LINEAR (STATIC PUSHOVER ANALYSIS) DAN ANALISIS PERKUATAN KAYU

Lebih terperinci

ANALISIS KINERJA STRUKTUR PADA GEDUNG BERTINGKAT DENGAN ANALISIS PUSHOVER MENGGUNAKAN SOFTWARE ETABS (STUDI KASUS : BANGUNAN HOTEL DI SEMARANG)

ANALISIS KINERJA STRUKTUR PADA GEDUNG BERTINGKAT DENGAN ANALISIS PUSHOVER MENGGUNAKAN SOFTWARE ETABS (STUDI KASUS : BANGUNAN HOTEL DI SEMARANG) ANALISIS KINERJA STRUKTUR PADA GEDUNG BERTINGKAT DENGAN ANALISIS PUSHOVER MENGGUNAKAN SOFTWARE ETABS (STUDI KASUS : BANGUNAN HOTEL DI SEMARANG) Nissa Zahra Rachman 1), Edy Purwanto 2), Agus Suptiyadi,

Lebih terperinci

BAB I PENDAHULUAN. Keandalan Struktur Gedung Tinggi Tidak Beraturan Menggunakan Pushover Analysis

BAB I PENDAHULUAN. Keandalan Struktur Gedung Tinggi Tidak Beraturan Menggunakan Pushover Analysis BAB I PENDAHULUAN 1.1 Latar Belakang Dewasa ini struktur gedung tidak beraturan menempati jumlah yang besar dalam ruang lingkup infrastruktur perkotaan modern. Beberapa penelitianpun telah dilakukan untuk

Lebih terperinci

KAJIAN KINERJA STRUKTUR RANGKA BRESING V-TERBALIK EKSENTRIK DAN KONSENTRIK (215S)

KAJIAN KINERJA STRUKTUR RANGKA BRESING V-TERBALIK EKSENTRIK DAN KONSENTRIK (215S) KAJIAN KINERJA STRUKTUR RANGKA BRESING V-TERBALIK EKSENTRIK DAN KONSENTRIK (215S) Made Sukrawa, Ida Bagus Dharma Giri, I Made Astarika Dwi Tama Jurusan Teknik Sipil Fakultas Teknik Universitas Udayana

Lebih terperinci

EVALUASI KINERJA BANGUNAN GEDUNG DPU WILAYAH KABUPATEN WONOGIRI DENGAN ANALISIS PUSHOVER

EVALUASI KINERJA BANGUNAN GEDUNG DPU WILAYAH KABUPATEN WONOGIRI DENGAN ANALISIS PUSHOVER EVALUASI KINERJA BANGUNAN GEDUNG DPU WILAYAH KABUPATEN WONOGIRI DENGAN ANALISIS PUSHOVER Yunalia Muntafi 1 1 Prodi Teknik Sipil, Fakultas Teknik Sipil dan Perencanaan, Universitas Islam Indonesia Jl. Kaliurang

Lebih terperinci

Konferensi Nasional Teknik Sipil 4 (KoNTekS 4) Sanur-Bali, 2-3 Juni 2010

Konferensi Nasional Teknik Sipil 4 (KoNTekS 4) Sanur-Bali, 2-3 Juni 2010 Konferensi Nasional Teknik Sipil (KoNTekS ) Sanur-Bali, - Juni 00 EVALUASI KINERJA SISTEM RANGKA PEMIKUL MOMEN BIASA (SRPMB) BAJA YANG DIDESAIN BERDASARKAN SNI 0-79-00 UNTUK DAERAH BERESIKO GEMPA TINGGI

Lebih terperinci

BAB 1 PENDAHULUAN. gempa di kepulauan Alor (11 November, skala 7,5), gempa Aceh (26 Desember, skala

BAB 1 PENDAHULUAN. gempa di kepulauan Alor (11 November, skala 7,5), gempa Aceh (26 Desember, skala BAB 1 PENDAHULUAN 1.1. Latar Belakang Pada tahun 2004, tercatat beberapa gempa besar yang terjadi di Indonesia, seperti gempa di kepulauan Alor (11 November, skala 7,5), gempa Aceh (26 Desember, skala

Lebih terperinci

EVALUASI KINERJA STRUKTUR BANGUNAN BAJA DENGAN MENGGUNAKAN PENGAKU EKSENTRIS (EBF) Ir. Torang Sitorus, MT.

EVALUASI KINERJA STRUKTUR BANGUNAN BAJA DENGAN MENGGUNAKAN PENGAKU EKSENTRIS (EBF) Ir. Torang Sitorus, MT. EVALUASI KINERJA STRUKTUR BANGUNAN BAJA DENGAN MENGGUNAKAN PENGAKU EKSENTRIS (EBF) TUGAS AKHIR Oleh : Cowens 100404171 Disetujui : Pembimbing Ir. Torang Sitorus, MT. BIDANG STUDI STRUKTUR DEPARTEMEN TEKNIK

Lebih terperinci

BAB V ANALISIS DAN PEMBAHASAN

BAB V ANALISIS DAN PEMBAHASAN BAB V ANALISIS DAN PEMBAHASAN 5.1 Periode Alami dan Modal Mass Participation Mass Ratio Periode alami struktur mencerminkan tingkat kefleksibelan sruktur tersebut. Untuk mencegah penggunaan struktur gedung

Lebih terperinci

ANALISIS PUSHOVER PADA BANGUNAN DENGAN SOFT FIRST STORY

ANALISIS PUSHOVER PADA BANGUNAN DENGAN SOFT FIRST STORY ANALISIS PUSHOVER PADA BANGUNAN DENGAN SOFT FIRST STORY Hizkia Yehezkiel Mamesah Steenie E. Wallah, Reky Stenly Windah Fakultas Teknik, Jurusan Teknik Sipil, Universitas Sam Ratulangi email: hizkiayehezkiel@gmail.com

Lebih terperinci

ANALISIS PERIODA BANGUNAN DINDING GESER DENGAN BASE ISOLATOR AKIBAT GAYA GEMPA

ANALISIS PERIODA BANGUNAN DINDING GESER DENGAN BASE ISOLATOR AKIBAT GAYA GEMPA ANALISIS PERIODA BANGUNAN DINDING GESER DENGAN BASE ISOLATOR AKIBAT GAYA GEMPA Muliadi 1, M. Kabir Ihsan 2 Jurusan Teknik Sipil, Universitas Malikussaleh email: muliadi.eng@gmail.com 1), ihsankb@gmail.com

Lebih terperinci

ANALISIS PERILAKU DAN KINERJA RANGKA BETON BERTULANG DENGAN DAN TANPA BREISING KABEL CFC

ANALISIS PERILAKU DAN KINERJA RANGKA BETON BERTULANG DENGAN DAN TANPA BREISING KABEL CFC ANALISIS PERILAKU DAN KINERJA RANGKA BETON BERTULANG DENGAN DAN TANPA BREISING KABEL CFC TUGAS AKHIR Oleh : P. Adi Yasa NIM: 1204105008 JURUSAN TEKNIK SIPIL FAKULTAS TEKNIK UNIVERSITAS UDAYANA 2016 LEMBAR

Lebih terperinci

EVALUASI KINERJA STRUKTUR BANGUNAN YANG MENGGUNAKAN SAMBUNGAN LEWATAN (LAP SPLICES) PADA UJUNG KOLOM

EVALUASI KINERJA STRUKTUR BANGUNAN YANG MENGGUNAKAN SAMBUNGAN LEWATAN (LAP SPLICES) PADA UJUNG KOLOM EVALUASI KINERJA STRUKTUR BANGUNAN YANG MENGGUNAKAN SAMBUNGAN LEWATAN (LAP SPLICES) PADA UJUNG KOLOM TUGAS AKHIR Oleh : Desindo Wijaya 100404163 Disetujui : Pembimbing Ir. Besman Surbakti, MT. BIDANG STUDI

Lebih terperinci

ANALISIS KINERJA GEDUNG BERTINGKAT BERDASARKAN EKSENTRISITAS LAY OUT DINDING GESER TERHADAP PUSAT MASSA DENGAN METODE PUSHOVER

ANALISIS KINERJA GEDUNG BERTINGKAT BERDASARKAN EKSENTRISITAS LAY OUT DINDING GESER TERHADAP PUSAT MASSA DENGAN METODE PUSHOVER ANALISIS KINERJA GEDUNG BERTINGKAT BERDASARKAN EKSENTRISITAS LAY OUT DINDING GESER TERHADAP PUSAT MASSA DENGAN METODE PUSHOVER Yuliar Azmi Adhitama 1), Edy Purwanto 2), Agus Supriyadi 3) 1) Mahasiswa Program

Lebih terperinci

PENGARUH RASIO KEKAKUAN LATERAL STRUKTUR TERHADAP PERILAKU DINAMIS STRUKTUR RANGKA BETON BERTULANG BERTINGKAT RENDAH

PENGARUH RASIO KEKAKUAN LATERAL STRUKTUR TERHADAP PERILAKU DINAMIS STRUKTUR RANGKA BETON BERTULANG BERTINGKAT RENDAH PENGARUH RASIO KEKAKUAN LATERAL STRUKTUR TERHADAP PERILAKU DINAMIS STRUKTUR RANGKA BETON BERTULANG BERTINGKAT RENDAH Ketut Sudarsana 1, Made Ery Artha Yudha 2 1 Jurusan Teknik Sipil, Fakultas Teknik, Universitas

Lebih terperinci

BAB II TINJAUAN PUSTAKA

BAB II TINJAUAN PUSTAKA 6 BAB II TINJAUAN PUSTAKA 2.1 Sistem Rangka Pemikul Momen Khusus (SRPMK) Sistem rangka pemikul momen khusus didesain untuk memiliki daktilitas yang tinggi pada saat gempa terjadi karena sistem rangka pemikul

Lebih terperinci

ANALISIS DAN PEMBAHASAN

ANALISIS DAN PEMBAHASAN BAB IV ANALISIS DAN PEMBAHASAN 4.1 Umum Pada bab ini akan dilakukan analisis terhadap model yang telah dibuat pada bab sebelumnya. Ada beberapa hal yang akan dianalisis dan dibahas kali ini. Secara umum

Lebih terperinci

KATA KUNCI: gempa, sistem ganda, SRPMK, SRBKK, 25%, gaya lateral, kekakuan

KATA KUNCI: gempa, sistem ganda, SRPMK, SRBKK, 25%, gaya lateral, kekakuan PENINJAUAN SNI 1726:2012 PASAL 7.2.5.1 MENGENAI DISTRIBUSI GAYA LATERAL PADA PENGGUNAAN SISTEM GANDA DENGAN RANGKA PEMIKUL MOMEN KHUSUS DAN RANGKA BAJA DENGAN BRESING KONSENTRIS KHUSUS Abijoga Pangestu

Lebih terperinci

ANALISIS STATIK NON-LINER PUSHOVER PADA OPTIMALISASI DESAIN GEDUNG PENDIDIKAN BERSAMA FKUB DENGAN VARIASI KONFIGURASI BRESING BAJA

ANALISIS STATIK NON-LINER PUSHOVER PADA OPTIMALISASI DESAIN GEDUNG PENDIDIKAN BERSAMA FKUB DENGAN VARIASI KONFIGURASI BRESING BAJA ANALISIS STATIK NON-LINER PUSHOVER PADA OPTIMALISASI DESAIN GEDUNG PENDIDIKAN BERSAMA FKUB DENGAN VARIASI KONFIGURASI BRESING BAJA NASKAH TERPUBLIKASI TEKNIK SIPIL Ditujukan untuk memenuhi persyaratan

Lebih terperinci

STUDI MENENTUKAN PARAMETER DAKTILITAS STRUKTUR GEDUNG TIDAK BERATURAN DENGAN ANALISIS PUSHOVER

STUDI MENENTUKAN PARAMETER DAKTILITAS STRUKTUR GEDUNG TIDAK BERATURAN DENGAN ANALISIS PUSHOVER STUDI MENENTUKAN PARAMETER DAKTILITAS STRUKTUR GEDUNG TIDAK BERATURAN DENGAN ANALISIS PUSHOVER Diva Gracia Caroline NRP : 0521041 Pembimbing : Olga Pattipawaej, Ph.D Pembimbing Pendamping : Yosafat Aji

Lebih terperinci

PRESENTASI TUGAS AKHIR

PRESENTASI TUGAS AKHIR PRESENTASI TUGAS AKHIR STUDI PERILAKU STRUKTUR BAJA MENGGUNAKAN SISTEM SELF CENTERING DENGAN SISTEM PRATEKAN PADA BALOK DAN KOLOM AKIBAT BEBAN GEMPA Oleh Syaiful Rachman 3105 100 093 Dosen Pembimbing:

Lebih terperinci

BAB III METODE ANALISIS

BAB III METODE ANALISIS BAB III METODE ANALISIS Pada tugas akhir ini, model struktur ang telah dibuat dengan bantuan software ETABS versi 9.0.0 kemudian dianalisis dengan prosedur ang dijelaskan pada ATC- 40 aitu dengan analisis

Lebih terperinci

ANALISIS GAYA GESER PADA BANGUNAN MENGGUNAKAN BASE ISOLATOR SEBAGAI PEREDUKSI BEBAN GEMPA

ANALISIS GAYA GESER PADA BANGUNAN MENGGUNAKAN BASE ISOLATOR SEBAGAI PEREDUKSI BEBAN GEMPA ANALISIS GAYA GESER PADA BANGUNAN MENGGUNAKAN BASE ISOLATOR SEBAGAI PEREDUKSI BEBAN GEMPA Muliadi 1, Mochammad Afifuddin 2, T. Budi Aulia 3 1) Jurusan Teknik Sipil Universitas Malikussaleh 2,3) Jurusan

Lebih terperinci

PENGARUH PENGGUNAAN SEISMIC BASE ISOLATION SYSTEM TERHADAP RESPONS STRUKTUR GEDUNG HOTEL IBIS PADANG ABSTRAK

PENGARUH PENGGUNAAN SEISMIC BASE ISOLATION SYSTEM TERHADAP RESPONS STRUKTUR GEDUNG HOTEL IBIS PADANG ABSTRAK VOLUME 8 NO. 1, FEBRUARI 2012 PENGARUH PENGGUNAAN SEISMIC BASE ISOLATION SYSTEM TERHADAP RESPONS STRUKTUR GEDUNG HOTEL IBIS PADANG Febrin Anas Ismail 1 ABSTRAK Sumatera Barat merupakan daerah rawan gempa.

Lebih terperinci

BAB V ANALISA DAN PEMBAHASAN

BAB V ANALISA DAN PEMBAHASAN BAB V ANALISA DAN PEMBAHASAN 5.1 Kurva Kapasitas Kurva kapasitas menunjukkan hubungan antara gaya gempa dan perpindahan yang terjadi hingga struktur runtuh. Berikut ini adalah kurva kapasitas dari model-model

Lebih terperinci

EVALUASI SNI 1726:2012 PASAL MENGENAI DISTRIBUSI GAYA LATERAL PADA PENGGUNAAN SISTEM GANDA

EVALUASI SNI 1726:2012 PASAL MENGENAI DISTRIBUSI GAYA LATERAL PADA PENGGUNAAN SISTEM GANDA EVALUASI SNI 1726:2012 PASAL 7.2.5.1 MENGENAI DISTRIBUSI GAYA LATERAL PADA PENGGUNAAN SISTEM GANDA Christianto Tirta Kusuma 1, Tiffany Putri Tjipto 2, Hasan Santoso 3 dan Ima Muljati 4 ABSTRAK : Gempa

Lebih terperinci

D3 TEKNIK SIPIL POLITEKNIK NEGERI BANDUNG BAB I PENDAHULUAN

D3 TEKNIK SIPIL POLITEKNIK NEGERI BANDUNG BAB I PENDAHULUAN BAB I PENDAHULUAN 1.1 Latar Belakang Indonesia merupakan negara yang berada di daerah rawan gempa karena tereletak pada 3 lempeng besar yaitu lempeng Australia-Hindia yang bergerak ke utara, lempeng Asia

Lebih terperinci

STUDI PERILAKU STRUKTUR BETON BERTULANG TERHADAP KINERJA BATAS AKIBAT PENGARUH TINGGI BANGUNAN DAN DIMENSI KOLOM BERDASARKAN SNI

STUDI PERILAKU STRUKTUR BETON BERTULANG TERHADAP KINERJA BATAS AKIBAT PENGARUH TINGGI BANGUNAN DAN DIMENSI KOLOM BERDASARKAN SNI STUDI PERILAKU STRUKTUR BETON BERTULANG TERHADAP KINERJA BATAS AKIBAT PENGARUH TINGGI BANGUNAN DAN DIMENSI KOLOM BERDASARKAN SNI -76- Oleh : Arie Wardhono *) Abstrak Kontrol terhadap perilaku bangunan

Lebih terperinci

EVALUASI PERBANDINGAN KINERJA DENGAN ANALISIS PUSHOVER PADA STRUKTUR BAJA TAHAN GEMPA

EVALUASI PERBANDINGAN KINERJA DENGAN ANALISIS PUSHOVER PADA STRUKTUR BAJA TAHAN GEMPA EVALUASI PERBANDINGAN KINERJA DENGAN ANALISIS PUSHOVER PADA STRUKTUR BAJA TAHAN GEMPA Laporan Tugas Akhir sebagai salah satu syarat untuk memperoleh gelar Sarjana dari Universitas Atma Jaya Yogyakarta

Lebih terperinci

BAB 1 PENDAHULUAN Umum

BAB 1 PENDAHULUAN Umum 1.1. Umum BAB 1 PENDAHULUAN Dewasa ini, Indonesia merupakan salah satu Negara yang memiliki perkembangan yang pesat. Hal ini ditandai dengan peningkatan ekonomi Indonesia yang cukup stabil setiap tahunnya,

Lebih terperinci

ANALISIS KINERJA STRUKTUR GEDUNG DENGAN COREWALL TUGAS AKHIR

ANALISIS KINERJA STRUKTUR GEDUNG DENGAN COREWALL TUGAS AKHIR ANALISIS KINERJA STRUKTUR GEDUNG DENGAN COREWALL TUGAS AKHIR Oleh : Fajar Pebriadi Kusumah NIM. 1004105008 JURUSAN TEKNIK SIPIL FAKULTAS TEKNIK UNIVERSITAS UDAYANA 2015 i ii iii UCAPAN TERIMA KASIH Puji

Lebih terperinci

ANALISIS RESPON BANGUNAN MENGGUNAKAN BASE ISOLATOR SEBAGAI PEREDUKSI BEBAN GEMPA DI WILAYAH GEMPA KUAT

ANALISIS RESPON BANGUNAN MENGGUNAKAN BASE ISOLATOR SEBAGAI PEREDUKSI BEBAN GEMPA DI WILAYAH GEMPA KUAT ISSN 2302-0253 10 Pages pp. 109-118 ANALISIS RESPON BANGUNAN MENGGUNAKAN BASE ISOLATOR SEBAGAI PEREDUKSI BEBAN GEMPA DI WILAYAH GEMPA KUAT Muliadi 1, Mochammad Afifuddin 2, T. Budi Aulia 3 1) Magister

Lebih terperinci

BAB 1 PENDAHULUAN. metoda desain elastis. Perencana menghitung beban kerja atau beban yang akan

BAB 1 PENDAHULUAN. metoda desain elastis. Perencana menghitung beban kerja atau beban yang akan BAB 1 PENDAHULUAN 1.1 LATAR BELAKANG PENULISAN Umumnya, pada masa lalu semua perencanaan struktur direncanakan dengan metoda desain elastis. Perencana menghitung beban kerja atau beban yang akan dipikul

Lebih terperinci

EVALUASI SENDI PLASTIS DENGAN ANALISIS PUSHOVER PADA GEDUNG TIDAK BERATURAN

EVALUASI SENDI PLASTIS DENGAN ANALISIS PUSHOVER PADA GEDUNG TIDAK BERATURAN EVALUASI SENDI PLASTIS DENGAN ANALISIS PUSHOVER PADA GEDUNG TIDAK BERATURAN DAVID VITORIO LESMANA 0521012 Pembimbing: Olga C. Pattipawaej, Ph.D. FAKULTAS TEKNIK JURUSAN TEKNIK SIPIL UNIVERSITAS KRISTEN

Lebih terperinci

EVALUASI STRUKTUR DENGAN PUSHOVER ANALYSIS

EVALUASI STRUKTUR DENGAN PUSHOVER ANALYSIS EVALUASI STRUKTUR DENGAN PUSHOVER ANALYSIS PADA GEDUNG KALIBATA RESIDENCES JAKARTA (The Evaluation Of The Structure by Using Pushover Analysis of Kalibata Residences Building Jakarta) Cipto Utomo, Rokhmad

Lebih terperinci

KINERJA STRUKTUR RANGKA BETON BERTULANG DENGAN PERKUATAN BREISING BAJA TIPE X

KINERJA STRUKTUR RANGKA BETON BERTULANG DENGAN PERKUATAN BREISING BAJA TIPE X HALAMAN JUDUL KINERJA STRUKTUR RANGKA BETON BERTULANG DENGAN PERKUATAN BREISING BAJA TIPE X TUGAS AKHIR Oleh: I Gede Agus Hendrawan NIM: 1204105095 JURUSAN TEKNIK SIPIL FAKULTAS TEKNIK UNIVERSITAS UDAYANA

Lebih terperinci

JURNAL TEKNIK ITS Vol. 5, No. 2, (2016) ISSN: ( Print)

JURNAL TEKNIK ITS Vol. 5, No. 2, (2016) ISSN: ( Print) A464 Analisis Perbandingan Biaya Perencanaan Gedung Menggunakan Metode Strength Based Design dengan Performance Based Design pada Berbagai Variasi Ketinggian Maheswari Dinda Radito, Shelvy Surya, Data

Lebih terperinci

BAB V ANALISIS KINERJA STRUKTUR

BAB V ANALISIS KINERJA STRUKTUR . BAB V ANALISIS KINERJA STRUKTUR 5.1 Pendahuluan Pada bab ini, kinerja struktur bangunan akan dianalisis dengan metode Non-Linear Static Pushover dengan menggunakan program ETABS v9.6.0. Perencanaan ini

Lebih terperinci

PERILAKU STRUKTUR BAJA TIPE MRF DENGAN BEBAN LATERAL BERDASARKAN SNI DAN METODE PERFORMANCE BASED PLASTIC DESIGN (PBPD)

PERILAKU STRUKTUR BAJA TIPE MRF DENGAN BEBAN LATERAL BERDASARKAN SNI DAN METODE PERFORMANCE BASED PLASTIC DESIGN (PBPD) Volume 13, No 1, Oktober 2014, 18 24 PERILAKU STRUKTUR BAJA TIPE MR DENGAN BEBAN LATERAL BERDASARKAN SNI 1726-2012 DAN METODE PERORMANCE BASED PLASTIC DESIGN (PBPD) Nidiasari, Jati Sunaryati, Eem Ikhsan

Lebih terperinci

Kajian Pemakaian Shear Wall dan Bracing pada Gedung Bertingkat

Kajian Pemakaian Shear Wall dan Bracing pada Gedung Bertingkat Reka Racana Jurusan Teknik Sipil Itenas Vol. 2 No. 4 Jurnal Online Institut Teknologi Nasional Desember 2016 Kajian Pemakaian Shear Wall dan Bracing pada Gedung Bertingkat SANTI GLORIA HUTAHAEAN, ASWANDY

Lebih terperinci

PERBANDINGAN PERUBAHAN KINERJA STRUKTUR RANGKA STRUKTUR BETON BERTULANG DAN BAJA DENGAN DINDING PENGISI

PERBANDINGAN PERUBAHAN KINERJA STRUKTUR RANGKA STRUKTUR BETON BERTULANG DAN BAJA DENGAN DINDING PENGISI PERBANDINGAN PERUBAHAN KINERJA STRUKTUR RANGKA STRUKTUR BETON BERTULANG DAN BAJA DENGAN DINDING PENGISI I Ketut Sudarsana 1*, Putu Deskarta 1, dan I Made Santika Putra 2 1 Dosen Teknik Sipil, Universitas

Lebih terperinci

BAB 1 PENDAHULUAN. hingga tinggi, sehingga perencanaan struktur bangunan gedung tahan gempa

BAB 1 PENDAHULUAN. hingga tinggi, sehingga perencanaan struktur bangunan gedung tahan gempa BAB 1 PENDAHULUAN 1.1 Latar Belakang Indonesia terletak dalam wilayah gempa dengan intensitas gempa moderat hingga tinggi, sehingga perencanaan struktur bangunan gedung tahan gempa menjadi sangat penting

Lebih terperinci

ANALISIS KINERJA STRUKTUR PADA BANGUNAN BERTINGKAT BERATURAN DAN KETIDAK BERATURAN HORIZONTAL SESUAI SNI

ANALISIS KINERJA STRUKTUR PADA BANGUNAN BERTINGKAT BERATURAN DAN KETIDAK BERATURAN HORIZONTAL SESUAI SNI ANALSS KNERJA STRUKTUR PADA BANGUNAN BERTNGKAT BERATURAN DAN KETDAK BERATURAN HORZONTAL SESUA SN ANALSS KNERJA STRUKTUR PADA BANGUNAN BERTNGKAT BERATURAN DAN KETDAK BERATURAN HORZONTAL SESUA SN 03-1726-2012

Lebih terperinci

Analisis Layout Shearwall Terhadap Perilaku Struktur Gedung. George Andalas 1) Suyadi 2) Hasti Riakara Husni 3)

Analisis Layout Shearwall Terhadap Perilaku Struktur Gedung. George Andalas 1) Suyadi 2) Hasti Riakara Husni 3) JRSDD, Edisi September 2016, Vol. 1, No. 1, Hal:491 502 (ISSN : 2303-0011) Analisis Layout Shearwall Terhadap Perilaku Struktur Gedung George Andalas 1) Suyadi 2) Hasti Riakara Husni 3) Abstract Shearwall

Lebih terperinci

DIRECT DISPLACEMENT BASED DESIGN PADA SISTEM RANGKA DENGAN KETIDAKBERATURAN PERGESERAN MELINTANG TERHADAP BIDANG

DIRECT DISPLACEMENT BASED DESIGN PADA SISTEM RANGKA DENGAN KETIDAKBERATURAN PERGESERAN MELINTANG TERHADAP BIDANG DIRECT DISPLACEMENT BASED DESIGN PADA SISTEM RANGKA DENGAN KETIDAKBERATURAN PERGESERAN MELINTANG TERHADAP BIDANG Amelinda Kusuma 1, Fonny Hindarto 2, Ima Muljati 3 ABSTRAK : Metode yang sering digunakan

Lebih terperinci

Cipta Adhi Prakasa dan Sjahril A. Rahim. ABSTRAK

Cipta Adhi Prakasa dan Sjahril A. Rahim.   ABSTRAK STUDI PERILAKU RANGKA BAJA SISTEM GANDA ANTARA SISTEM RANGKA PEMIKUL MOMEN DENGAN SISTEM RANGKA BRESING KONSENTRIS TERHADAP BEBAN GEMPA DENGAN ANALISIS PUSHOVER Cipta Adhi Prakasa dan Sjahril A. Rahim

Lebih terperinci